Preconcentration and determination of mercury(II) at a chemically modified electrode containing 3-(2-thioimidazolyl)propyl silica gel
Contribuinte(s) |
Universidade Estadual Paulista (UNESP) |
---|---|
Data(s) |
27/05/2014
27/05/2014
01/11/2005
|
Resumo |
A mercury-sensitive chemically modified graphite paste electrode was constructed by incorporating modified silica gel into a conventional graphite paste electrode. The functional group attached to the (3-chloropropyl) silica gel surface was 2-mercaptoimidazole, giving a new product denoted by 3-(2-thioimidazolyl)propyl silica gel, which is able to complex mercury ions. Mercury was chemically adsorbed on the modified graphite paste electrode containing 3-(2-thioimidazolyl)propyl silica (TIPSG GPE) by immersion in a Hg(II) solution, and the resultant surface was characterized by cyclic and differential pulse anodic stripping voltammetry. One cathodic peak at 0.1 V and other anodic peak at 0.34 V were observed on scanning the potential from -0.1 to 0.8 V (0.01 M KNO3; ν = 2.0 mV s-1 νs. Ag/AgCl). The anodic peak at 0.34 V show an excellent sensitivity for Hg(II) ions in the presence of several foreign ions. A calibration graph covering the concentration range from 0.02 to 2 mg L-1 was obtained. The detection limit was estimated to be 5 μg L-1. The precision for six determinations of 0.05 and 0.26 mg L-1 Hg(II) was 3.0 and 2.5% (relative standard deviation), respectively. The method can be used to determine the concentration of mercury(II) in natural waters contaminated by this metal. 2005 © The Japan Society for Analytical Chemistry. |
Formato |
1359-1363 |
Identificador |
http://dx.doi.org/10.2116/analsci.21.1359 Analytical Sciences, v. 21, n. 11, p. 1359-1363, 2005. 0910-6340 1348-2246 http://hdl.handle.net/11449/68485 10.2116/analsci.21.1359 WOS:000234120400017 2-s2.0-28444472012 2-s2.0-28444472012.pdf |
Idioma(s) |
eng |
Relação |
Analytical Sciences |
Direitos |
openAccess |
Palavras-Chave | #2 imidazolidinethione #2-mercaptoimidazole #cation #drug derivative #fresh water #graphite #imidazole derivative #mercaptoimidazole #mercury #sea water #silica gel #silicon dioxide #calibration #chemistry #electrochemistry #instrumentation #ion selective electrode #methodology #oxidation reduction reaction #pH #reproducibility #Calibration #Cations #Electrochemistry #Ethylenethiourea #Fresh Water #Graphite #Hydrogen-Ion Concentration #Imidazoles #Ion-Selective Electrodes #Mercury #Oxidation-Reduction #Reproducibility of Results #Seawater #Silicon Dioxide |
Tipo |
info:eu-repo/semantics/article |