923 resultados para Aortic Input Impedance


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background and Purpose - the purpose of this research was to evaluate whether an association exists between the presence of atherosclerotic plaque in the thoracic aorta and left ventricular hypertrophy (LVH) in patients with a cerebrovascular event.Methods - We included 116 consecutive patients ( 79 men; mean age, 62 +/- 12.4 years) with previous history of stroke or transient ischemic attack in a cross-sectional study. Transthoracic echocardiogram was performed to diagnose LVH and transesophageal echocardiogram for the detection of atheromas of the thoracic aorta. Continuous variables were analyzed by Student t or Mann-Whitney tests and categorized variables by Goodman test. From the significant association of LVH and age with atheromatous disease of the aorta, an adjustment to the multivariate logistic model was made using high blood pressure history or age as covariates. All of the statistical tests were carried out at a level of 5% significance.Results - Almost half of the patients (43.1%) presented atherosclerotic lesions in the aorta. LVH was present in 90.0% of patients with plaque and in only 30.3% of patients without plaque. Using high blood pressure as a covariate, the risk of patients with LVH presenting atherosclerotic plaque in the aorta was 18.23-fold greater than the risk for patients without LVH (95% CI, 5.68 to 58.54; P < 0.0001). Adding age into the model, the risk increased to 26.36 ( 95% CI, 7.14 to 97.30; P < 0.0001).Conclusions - LVH detected by conventional echocardiogram is associated with high risk of atherosclerotic plaque in the aorta and would be used as a criterion for indication of transesophageal echocardiography in patients with previous stroke or transient ischemic attack LVH.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Structural features of segmental parts of the aorta of the dog were studied by light microscopy (LM) and scanning electron microscopy (SEM). The variability in the wall architecture composition and vascular thickness of the ascending (T2-3 level), thoracic (T7-8 level) and abdominal (L6-7 infrarenal level) segments of the aorta was analysed. Morphological features such as presence of intimal folds, pattern of the medial myoconnective components with segmental variations in the number of elastic lamellae, whose relative number was higher in the thoracic aorta (ascending and descending parts), compared with the abdominal aorta, and a network of connective (stromal) elements formed by elastic and collagen lamellae and fibres in the adventitia were observed. The results were discussed on a histophysiological basis, because small but significant segmental differences had been characterized in the aortic wall structure of the dog.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Opossum is considered one of the most primitive mammals, with transition evolutive characteristics. In mammals, the aorta artery is referred as the main body blood vessel. The arteries wall structural organization follows a basic pattern, being contituted of three tunics: Intima, Median and Adventicial. After euthanasia, three samples of opossum had segments from the aorta artery ascendent, thoracic descending and abdominal descending portions removed, fixed in phormalin at 10% for 48 hours. Then, the material was washed in alcohol 70% several times, dehydrated in alcohois of growing concentrations, diafanized in xylol and included in "paraplast". Cuts with 5 to 7 mu m of thickness were placed in histological laminae and submitted to color methods of Hematoxilin-Eosin, Masson, Mallory and Calleja Tricromics. It was observed that in the different portions ascendent, thoracic and abdominal descending of aorta, the intima tunic presents much thick, made up of a layer of smooth muscular cells and elastic fibers, forming a limiting internal elastic membrane. In the three portions studied, the median tunic was the most evident layer, constituted of colagen fibers, smooth muscular cells arranged in a circular manner and elastic fibers, showing a variation in the mural elements proportion. It was evidenced the presence of a external elastic lamina, marking the transition between the median and adventicial tunic, formed by elastic fibers condensation. The aortic adventicial tunic showed to be little organized, having in its structure predominantely colagen fibers beans with some isolated smooth muscular fibers or in small fascicules among a few elastic fibers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Several runs of the BEAM4 model were carried out, combining several sets of input parameters from von Bertalanffy's growth curve (Lt = L-x[1 - e(-k(-to))]) and the natural mortality (M), with sets or parameters from the length-weight relationship (W=aL(b)). Further simulations were made with variations of +/- 20%, in the input parameters: recruitment (R), catchability coefficient (q), and the lengths at which 50 and 75% of the fishes are retained by the net (L-50%, and L-75%). The data used were those of the pair trawl fisheries for corvina Micropogonias furnieri, off southeastern Brazil. Results showed variations in the output (landed weight) ranging from - 62 to 147% associated with the diverse sets of VBGF and LWR parameters, and lower variations associated with the other input parameters tested. (C) 2001 Elsevier B.V. B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A strong association between the benefits of physical exercise on the cardiovascular disease with an improvement of the endothelium-derived relaxing factor production has been consistently shown. The purpose of this study was to evaluate the effect of exercise training associated with high caloric diet in the reactivity of rat mesenteric and aortic rings. Experimental protocol consisted of 4 weeks of high caloric diet consumption previous to 4 weeks of run training (1.2 km/h, 0% grade, in sessions of 60 min, 5 days/week). Concentrations of triglycerides, glucose, insulin and nitrite/nitrate levels were measured and atherogenic index was calculated. Concentration-response curves to acetylcholine (10 nM-100 mu M), sodium nitroprusside (100 pM-100 nM) and phenylephrine (1 nM-3 mu M) were obtained. Exercise training reduced body mass (6%) and triglyceride levels (about 54%), without changes in glucose and insulin concentrations. An improvement of endothelium-dependent relaxation responses to acetylcholine in mesenteric and aortic rings was observed in trained group. No changes were seen for sodium nitroprusside and phenylephrine. In conclusion, our study is the first to show clearly that run training promotes an improvement of the endothelium-dependent relaxing response in aorta and mesenteric rings from rats fed with high caloric diet and that is associated with increase of NO production. (c) 2006 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The analysis of the faradaic impedance of electroactive films provides a characteristic point from which it is possible to estimate the thickness of thin films. Thus, electrochemical impedance spectroscopy was used in this paper as a fast and easy technique to estimate this thickness. The proposed method was checked on PB films. (c) 2006 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The corrosion resistance of three of the constituent phases in high copper dental amalgams has been investigated by electrochemical methods in 0.9% NaCl solution. Polarization curves show corrosion potentials most positive for gamma(1)-Ag2Hg3, followed by Ag-Cu, and gamma-Ag3Sn in agreement with the order of corrosion resistance deduced from the corrosion currents. Complex plane impedance plots at the open circuit potential showed distorted semicircles with diffusional components at low frequency for Ag-Hg and Ag-Cu, while for gamma-Ag3Sn a layer of corrosion products is formed, partially or completely covering the surface of the electrode. Impedance and noise spectra have been compared in the frequency domain, and show good agreement. (C) 2004 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A careful analysis of the impedance response of SnO2 thick films under vacuum and air atmosphere is reported in the present work. The AC electrical resistance was analyzed and it was shown that it is highly frequency dependent. Different models and its equivalent circuit representation were proposed and carefully analyzed based on the microstructure features of the device. Basically, an interpretation of the frequency dependent resistance was proposed based on the fact that different grains characteristics and junctions exist. These different grains and junctions are the main source of resistance dependent feature. An equivalent circuit model, considering different grain sizes associated with different grain boundary junctions characteristics, was introduced so that a consistent interpretation of the results was possible.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Glassy carbon electrodes (GCE) were modified with poly(glutamic acid) acid films prepared using three different procedures: glutamic acid monomer electropolymerization (MONO), evaporation of poly(glutamic acid) (PAG) and evaporation of a mixture of poly(glutamic acid)/glutaraldehyde (PAG/GLU). All three films showed good adherence to the electrode surface. The performance of the modified GCE was investigated by cyclic voltammetry and differential pulse voltammetry, and the films were characterized by atomic force microscopy (AFM) and electrochemical impedance spectroscopy (EIS). The three poly(glutamic acid) modified GCEs were tested using the electrochemical oxidation of ascorbic acid and a decrease of the overpotential and the improvement of the oxidation peak current was observed. The PAG modified electrode surfaces gave the best results. AFM morphological images showed a polymeric network film formed by well-defined nanofibres that may undergo extensive swelling in solution, allowing an easier electron transfer and higher oxidation peaks. (C) 2007 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Um longo caminho foi percorrido desde as primeiras intervenções cirúrgicas feitas para o tratamento do aneurisma de aorta abdominal. Ao longo deste tempo, várias inovações foram criadas, no sentido de reduzir a invasividade dos procedimentos e melhorar sua segurança e durabilidade. Nesta revisão, são discutidos os principais e recentes avanços em intervenções sobre aneurismas aórticos, incluindo a restauração aórtica endovascular, a cirurgia aórtica videolaparoscópica, as técnicas híbridas convencionais e endovasculares, as técnicas combinadas videolaparoscópicas e endovasculares, bem como as perspectivas futuras, tanto para aorta torácica como abdominal. Diante de tantas transformações e evolução, o cirurgião vascular moderno terá que ter sua mente aberta para as novidades e desenvolver capacitação ampla com diferentes técnicas para proporcionar a melhor opção terapêutica para seus pacientes.