991 resultados para Air power
Resumo:
Introduction Schistosomiasis is a parasitic disease of public health concern in Brazil, and the construction of hydroelectric dams, in addition to increasing permanent human settlement and tourism, has created conditions suitable for the establishment of mollusks that can transmit schistosomiasis. Such areas require a number of actions to prevent the establishment of schistosomiasis. This paper reports on a freshwater malacological survey carried out in the geographical area of the Manso Power Plant. Methods Mollusks were collected in 18 municipalities in the State of Mato Grosso between February 2002 and February 2004 (qualitative study) and from April 2009 to February 2011 (quantitative study). Results Thirty-one species of mollusks were collected, including newly recorded species (Antillorbis nordestensis and Burnupia ingae). In addition, the geographic distributions of known species, including Biomphalaria straminea, a snail vector of Schistosoma mansoni, were expanded. A total of 4,507 specimens were collected in the APM Manso reservoir (Usina Hidrelétrica de Aproveitamento Múltiplo de Manso) during the quantitative study, and Biomphalaria amazonica was found in six of the 10 localities analyzed. The Afroasiatic species Melanoides tuberculata, introduced after February 2009, was the dominant species (relative abundance 94.96%). Conclusions The study area is epidemiologically important due to the occurrence of B. straminea and B. amazonica, which are vectors of schistosomiasis, and M. tuberculata, a snail host of Centrocestus formosanus, which is responsible for centrocestiasis transmission. Observations of M. tuberculata and the exotic freshwater clams Corbicula fluminea and Corbicula largillierti raise concerns about biodiversity.
Resumo:
This thesis provides an alternative framework to analyze power and ethics practiced in everyday conversations, which constitute processes of organizing. Drawing upon narrative frameworks, the analyses of messages posted on an online message board demonstrate people’s imaginative capacity to create relevant stories, in respect of their precise grasp of factual understandings, contextual relevance and evaluative/moral appropriateness, by appropriating others’ words. Based on the empirical analyses, the thesis indicates that studies on power and ethics in organizations can be re-oriented towards appreciating irremediable power imbalances by offering alternative ways of member’s denoting experiences of power.
Resumo:
Cylindrical specimens of bone measuring 15 mm in diameter were obtained from the lateral cortical layer of 10 pairs of femurs and tibias. A central hole 3.2 mm in diameter was drilled in each specimen. The hole was tapped, and a 4.5 mm cortical bone screw was inserted from the outer surface. The montage was submitted to push-out testing up to a complete strip of the bone threads. The cortical thickness and rupture load were measured, and the shear stress was calculated. The results were grouped according to the bone segment from which the specimen was obtained. The results showed that bone cortex screw holding power is dependent on the bone site. Additionally, the diaphyseal cortical bone tissue is both quantitatively and qualitatively more resistant to screw extraction than the metaphyseal tissue.
Resumo:
Modern fully integrated transceivers architectures, require circuits with low area, low cost, low power, and high efficiency. A key block in modern transceivers is the power amplifier, which is deeply studied in this thesis. First, we study the implementation of a classical Class-A amplifier, describing the basic operation of an RF power amplifier, and analysing the influence of the real models of the reactive components in its operation. Secondly, the Class-E amplifier is deeply studied. The different types of implementations are reviewed and theoretical equations are derived and compared with simulations. There were selected four modes of operation for the Class-E amplifier, in order to perform the implementation of the output stage, and the subsequent comparison of results. This led to the selection of the mode with the best trade-off between efficiency and harmonics distortion, lower power consumption and higher output power. The optimal choice was a parallel circuit containing an inductor with a finite value. To complete the implementation of the PA in switching mode, a driver was implemented. The final block (output stage together with the driver) got 20 % total efficiency (PAE) transmitting 8 dBm output power to a 50 W load with a total harmonic distortion (THD) of 3 % and a total consumption of 28 mW. All implementations are designed using standard 130 nm CMOS technology. The operating frequency is 2.4 GHz and it was considered an 1.2 V DC power supply. The proposed circuit is intended to be used in a Bluetooth transmitter, however, it has a wider range of applications.
Resumo:
Based on the report for the unit “Métodos Interactivos de Participação e Decisão A” (Interactive methods of participation and decision A), coordinated by Prof. Lia Maldonado Teles de Vasconcelos and Prof. Nuno Miguel Ribeiro Videira Costa. This unit was provided for the PhD Program in Technology Assessment in 2015/2016.
Resumo:
The recent proposals presented by EPA aimed to reduce the dependency of fossil fuels and to lower current emissions levels, hoping to gradually shift electric generation units to renewable energy sources. Actually, the Final Rule Proposal announcement day exhibited a negative Abnormal Return on Fossil Fuels but the following days had positive Abnormal Returns, mostly due to legislative change perceived by financial markets which eased up implementation periods of the proposed measures in the Final Rule when compared to the Draft Rule. Oppositely, Renewables and Solar Portfolios exhibited negative Cumulative Abnormal Returns over the period surrounding the Final Rule.
Resumo:
Field measurement programs in Brazil during the dry season months of August and September in 1979 and 1980 have demonstrated the great importance of the continental tropics in global air chemistry. Especially in the mixed layer, the air composition over land is much different from that over the ocean and the land areas are clearly longe scale sources of many inportant trace gases. During the dry season much biomass, burning takes place especially in the cerrado regions leading to substantial emission of air pollutants, such as CO, NOx, N2O, CH4 and other hydrocarbons. Ozone concentrations are alsoenhanced due to photochemical reactions. Biogenic organic emissions from tropical forests play likewise an important role in the photochemistry of the atmosphere. Carbon monoxide was found to be present in high concentrations in the boundary layer of the tropical forest, but ozone concentrations were much lower than in the cerrado.
Resumo:
This paper proposes a multifunctional converter to interface renewable energy sources (e.g., solar photovoltaic panels) and electric vehicles (EVs) with the power grid in smart grids context. This multifunctional converter allows deliver energy from the solar photovoltaic panels to an EV or to the power grid, and exchange energy in bidirectional mode between the EV and the power grid. Using this multifunctional converter are not required multiple conversion stages, as occurs with the traditional solutions, where are necessary two power converters to integrate the solar photovoltaic system in the power grid and also two power converters to integrate an off-board EV battery charger in the power grid (dc-dc and dc-ac power converters in both cases). Taking into account that the energy provided (or delivered) from the power grid in each moment is function of the EV operation mode and also of the energy produced from the solar photovoltaic system, it is possible to define operation strategies and control algorithms in order to increase the energy efficiency of the global system and to improve the power quality of the electrical system. The proposed multifunctional converter allows the operation in four distinct cases: (a) Transfer of energy from the solar photovoltaic system to the power grid; (b) Transfer of energy from the solar photovoltaic system and from the EV to the power grid; (c) Transfer of energy from the solar photovoltaic system to the EV or to the power grid; (d) Transfer of energy between the EV and the power grid. Along the paper are described the system architecture and the control algorithms, and are also presented some computational simulation results for the four aforementioned cases. It is also presented a comparative analysis between the traditional and the proposed solution in terms of operation efficiency and estimated cost of implementation.
Resumo:
This paper presents a critical and quantitative analysis of the influence of the Power Quality in grid connected solar photovoltaic microgeneration installations. First are introduced the main regulations and legislation related with the solar photovoltaic microgeneration, in Portugal and Europe. Next are presented Power Quality monitoring results obtained from two residential solar photovoltaic installations located in the north of Portugal, and is explained how the Power Quality events affect the operation of these installations. Afterwards, it is described a methodology to estimate the energy production losses and the impact in the revenue caused by the abnormal operation of the electrical installation. This is done by comparing the amount of energy that was injected into the power grid with the theoretical value of energy that could be injected in normal conditions. The performed analysis shows that Power Quality severally affects the solar photovoltaic installations operation. The losses of revenue in the two monitored installations M1 and M2 are estimated in about 27% and 22%, respectively.
Resumo:
This paper presents the proposal of a three phase current source shunt active power filter (CS-SAPF) with photovoltaic grid interface. The proposed system combines the compensation of reactive power and harmonics with the injection of energy from a solar photovoltaic array into the electrical power grid. The proposed equipment presents the advantage of giving good use to the current source inverter, even when the solar photovoltaic array is not producing energy. The paper describes the control system of the CS SAPF, the energy injection control strategy, and the current harmonics and power factor compensation strategy. Simulation results to assess the performance of the proposed system are also presented.
Resumo:
As a renewable energy source, the use of forest biomass for electricity generation is advantageous in comparison with fossil fuels, however the activity of forest biomass power plants causes adverse impacts, affecting particularly neighbouring communities. The main objective of this study is to estimate the effects of the activity of forest biomass power plants on the welfare of two groups of stakeholders, namely local residents and the general population and we apply two stated preference methods: contingent valuation and discrete choice experiments, respectively. The former method was applied to estimate the minimum compensation residents of neighbouring communities of two forest biomass power plants in Portugal would be willing to accept. The latter method was applied among the general population to estimate their willingness to pay to avoid specific environmental impacts. The results show that the presence of the selected facilities affects individuals’ well-being. On the other hand, in the discrete choice experiments conducted among the general population all impacts considered were significant determinants of respondents’ welfare levels. The results of this study stress the importance of performing an equity analysis of the welfare effects on different groups of stakeholders from the installation of forest biomass power plants, as their effects on welfare are location and impact specific. Policy makers should take into account the views of all stakeholders either directly or indirectly involved when deciding crucial issues regarding the sitting of new forest biomass power plants, in order to achieve an efficient and equitable outcome.
Resumo:
Sustainability is frequently defined by its three pillars: economically viable, socially equitable, and environmentally bearable. Consequently the evaluation of the sustainability of any decision, public or private, requires information on these three dimensions. This paper focuses on social sustainability. In the context of renewable energy sources, the examination of social sustainability requires the analysis of not only the efficiency but also the equity of its welfare impacts. The present paper proposes and applies a methodology to generate the information necessary to do a proper welfare analysis of the social sustainability of renewable energy production facilities. This information is key both for an equity and an efficiency analysis. The analysis focuses on the case of investments in renewable energy electricity production facilities, where the impacts on local residents’ welfare are often significantly different than the welfare effects on the general population. We apply the contingent valuation method to selected facilities across the different renewable energy power plants located in Portugal and conclude that local residents acknowledge differently the damage sustained by the type, location and operation of the plants. The results from these case studies attest to the need of acknowledging and quantifying the negative impacts on local communities when assessing the economic viability, social equity and environmental impact of renewable energy projects.
Resumo:
This paper presents a comparison between three switching techniques that can be used in three-phase four-wire Shunt Active Power Filters (SAPFs). The implemented switching techniques are: Periodic-Sampling (PS), Triangular Carrier Pulse-Width Modulation (TC-PWM) and Space Vector PWM (SVPWM). The comparison between them is made in terms of the compensated currents THD%, implementation complexity, necessary CPU time and SAPF efficiency. To perform this comparison are presented and analyzed several experimental results, obtained with a 20 kVA Shunt Active Power Filter prototype, specially developed for this purpose. The control system of the developed SAPF is based in the p-q Theory with a grid synchronization algorithm p-PLL.
Resumo:
The role of vitamin C on physiological responses of matrinxã (Brycon amazonicus) submitted to air exposure was analyzed. Nine hundred fish (70.15 g) were distributed in fifteen 500 l boxes (60 fish.box-1) and fed five rations (treatments): Control (no vitamin C); T100 (100 mg); T200 (200 mg); T400 (400 mg) and T800 (800 mg of vitamin C kg.ration-1). Each ration was offered to fish of three boxes during 60 days before the stress challenge that consisted of exposing fish to air for two minutes. Samplings were carried out for 5, 15, 30 and 60 minutes after the air exposure. Blood was collected for glucose, cortisol, total protein, sodium, chloride, hematocrit, hemoglobin determination, and white and red cell count. Liver was removed for hepatosomatic index (HSI) calculation and glycogen determination. Vitamin C did not affect the levels of cortisol, chloride, total protein, hemoglobin, leukocytes, hepatic glycogen or HSI in air exposed fish. Blood glucose levels elevation observed 60 minutes after the challenge did not depend on the levels of vitamin C, nor did the drop in serum sodium levels verified 60 minutes after stressor. In general, hematocrit did not change by effect of vitamin C but it was lower at 15 and 30 minutes after the challenge. The number of erythrocytes decreased in fish after 5 minute sampling in all treatments, especially at 30 and 60 minutes. The air exposure evoked alterations in stress indicators of matrinxã, and the vitamin C did not alter the responses.
Resumo:
This paper presents a single-phase Series Active Power Filter (Series APF) for mitigation of the load voltage harmonic content, while maintaining the voltage on the DC side regulated without the support of a voltage source. The proposed series active power filter control algorithm eliminates the additional voltage source to regulate the DC voltage, and with the adopted topology it is not used a coupling transformer to interface the series active power filter with the electrical power grid. The paper describes the control strategy which encapsulates the grid synchronization scheme, the compensation voltage calculation, the damping algorithm and the dead-time compensation. The topology and control strategy of the series active power filter have been evaluated in simulation software and simulations results are presented. Experimental results, obtained with a developed laboratorial prototype, validate the theoretical assumptions, and are within the harmonic spectrum limits imposed by the international recommendations of the IEEE-519 Standard.