975 resultados para work zone safety


Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This is the first complete textbook designed for physiotherapists and occupational therapists on the topic of pain. It was developed for use in conjunction with the International Association for the Study of Pain's pain curriculum for OTs and PTs. The book addresses the nature of pain, the neuroanatomical and neurophysiological substrates of pain, the psychological... More aspects of pain, the lifespan approach to pain, pain measurement, pain and placebo, modalities for treating pain, and special topics in pain. It provides an overview of the physiological, psychosocial, and environmental aspects of pain experience across the lifespan. Aimed primarily at OTs and PTs the assessment and interventions issues pertaining to the perspectives of each profession are discussed in detail. The book is also relevant to the other health professions involved in pain management or intending to work in this area.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The authors present the first clinical implementation of an endoscopic-assisted percutaneous anterolateral radiofrequency cordotomy. The aim of this article is to demonstrate the intradural endoscopic visualization of the cervical spinal cord via a percutaneous approach to refine the spinal target for anterolateral cordotomy, avoiding undesired trauma to the spinal tissue or injury to blood vessels. Initially, a lateral puncture of the spinal canal in the C1-2 interspace is performed, guided by fluoroscopy. As soon as CSF is reached by the guide cannula (17-gauge needle), the endoscope can be inserted for visualization of the spinal cord and its surrounding structures. The endoscopic visualization provided clear identification of the pial surface of the spinal cord, arachnoid membrane, dentate ligament, dorsal and ventral root entry zone, and blood vessels. The target for electrode insertion into the spinal cord was determined to be the midpoint from the dentate ligament and the ventral root entry zone. The endoscopic guidance shortened the fluoroscopy usage time and no intrathecal contrast administration was needed. Cordotomy was performed by a standard radiofrequency method after refining of the neurophysiological target. Satisfactory analgesia was provided by the procedure with no additional complications or CSF leak. The initial use of this technique suggests that a percutaneous endoscopic procedure may be useful for particular manipulation of the spinal cord, possibly adding a degree of safety to the procedure and improving its effectiveness. (DOI: 10.3171/2010.4.JNS091779)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: The most common laparoscopic complications are associated with trocar insertion. The purpose of this study was to develop an objective method of evaluating the safety profile of various access devices used in laparoscopic surgery. STUDY DESIGN: In 20 swine, 6 bladed and 2 needle access devices were evaluated. A force profile was determined by measuring the force required to drive the trocar or needle through the fascia and into the peritoneum, at 0 and 10 mmHg. The amount Of tissue deformation, the length of blade exposed, and the duration of exposure were measured using a high-speed digital imaging system. RESULTS: The needle system without the sheath required the least driving force and had the most favorable force profile. In contrast, the bladed, nonretractable trocar system required a higher driving force and a rapid loss of resistance. Insertion under a pneumoperitoneum did not significantly alter the force profile of the various access devices except for the amount of tissue deformation. With the bladed system, the blade itself was exposed for an average of 0.5 to 1.0 seconds for a distance of 4.5 to 5.0 cm. In comparison, the needle system was exposed for 0.2 seconds for a distance of 1.8 cm. CONCLUSIONS: We developed a reproducible method of measuring the forces required to place the access systems, their pattern of resistance loss, and the characteristics of the blade exposure. These parameters may provide an adjunctive and objective measurement of safety, allowing for more direct comparison between various trocar designs. (J Am Coll Surg 2009;209:222-232. (C) 2009 by the American College of Surgeons)

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: Pediatric percutaneous renal biopsy (Bx) is a routine procedure in pediatric nephrology to obtain renal tissues for histological study. We evaluated the safety, efficacy, indications and renal findings of this procedure at a tertiary care pediatric university hospital and compared our findings with the literature. Methods: Retrospective study based on medical records from January 1993 to June 2006. Results: In the study period, 305 Bx were performed in 262 patients, 127 (48.5%) male, aged 9.8 +/- 4.2 years. A 16-gauge needle was utilized in 56/305 Bx, an 18-gauge needle in 252/305 Bx (82.6%). 56.1% Bx were performed under sedation plus local anesthesia, 43.9% under general anesthesia. The number of punctures per Bx was 3.1 +/- 1.3. Minor complications occurred in 8.6% procedures. The 16-gauge needle caused a higher frequency of renal hematomas (p = 0.05). The number of glomeruli per puncture was >= 5 in 96.7% and >= 7 in 92%. Glomeruli number per puncture and frequency of complications were not different according to the type of anesthesia used. A renal pathology diagnosis was achieved in 93.1% Bx. The main indications of Bx were nephrotic syndrome (NS), lupus nephritis (LN) and hematuria (HE). The diagnosis of minimal change disease (MCD) (61.3%), class V (35.6%) and IgA nephropathy (26.3%) predominated in NS, LN and HE patients, respectively. Conclusion: Pediatric real-time ultrasound-guided percutaneous renal biopsy was safe and effective. The main clinical indications for Bx were NS and LN, the predominant renal pathology diagnoses were MCD and class V LN.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador: