948 resultados para trans-femoral amputees
Resumo:
BACKGROUND It is unclear whether radial compared with femoral access improves outcomes in unselected patients with acute coronary syndromes undergoing invasive management. METHODS We did a randomised, multicentre, superiority trial comparing transradial against transfemoral access in patients with acute coronary syndrome with or without ST-segment elevation myocardial infarction who were about to undergo coronary angiography and percutaneous coronary intervention. Patients were randomly allocated (1:1) to radial or femoral access with a web-based system. The randomisation sequence was computer generated, blocked, and stratified by use of ticagrelor or prasugrel, type of acute coronary syndrome (ST-segment elevation myocardial infarction, troponin positive or negative, non-ST-segment elevation acute coronary syndrome), and anticipated use of immediate percutaneous coronary intervention. Outcome assessors were masked to treatment allocation. The 30-day coprimary outcomes were major adverse cardiovascular events, defined as death, myocardial infarction, or stroke, and net adverse clinical events, defined as major adverse cardiovascular events or Bleeding Academic Research Consortium (BARC) major bleeding unrelated to coronary artery bypass graft surgery. The analysis was by intention to treat. The two-sided α was prespecified at 0·025. The trial is registered at ClinicalTrials.gov, number NCT01433627. FINDINGS We randomly assigned 8404 patients with acute coronary syndrome, with or without ST-segment elevation, to radial (4197) or femoral (4207) access for coronary angiography and percutaneous coronary intervention. 369 (8·8%) patients with radial access had major adverse cardiovascular events, compared with 429 (10·3%) patients with femoral access (rate ratio [RR] 0·85, 95% CI 0·74-0·99; p=0·0307), non-significant at α of 0·025. 410 (9·8%) patients with radial access had net adverse clinical events compared with 486 (11·7%) patients with femoral access (0·83, 95% CI 0·73-0·96; p=0·0092). The difference was driven by BARC major bleeding unrelated to coronary artery bypass graft surgery (1·6% vs 2·3%, RR 0·67, 95% CI 0·49-0·92; p=0·013) and all-cause mortality (1·6% vs 2·2%, RR 0·72, 95% CI 0·53-0·99; p=0·045). INTERPRETATION In patients with acute coronary syndrome undergoing invasive management, radial as compared with femoral access reduces net adverse clinical events, through a reduction in major bleeding and all-cause mortality. FUNDING The Medicines Company and Terumo.
Resumo:
End caps are intended to prevent nail migration (push-out) in elastic stable intramedullary nailing. The aim of this study was to investigate the force at failure with and without end caps, and whether different insertion angles of nails and end caps would alter that force at failure. Simulated oblique fractures of the diaphysis were created in 15 artificial paediatric femurs. Titanium Elastic Nails with end caps were inserted at angles of 45°, 55° and 65° in five specimens for each angle to create three study groups. Biomechanical testing was performed with axial compression until failure. An identical fracture was created in four small adult cadaveric femurs harvested from two donors (both female, aged 81 and 85 years, height 149 cm and 156 cm, respectively). All femurs were tested without and subsequently with end caps inserted at 45°. In the artificial femurs, maximum force was not significantly different between the three groups (p = 0.613). Push-out force was significantly higher in the cadaveric specimens with the use of end caps by an up to sixfold load increase (830 N, standard deviation (SD) 280 vs 150 N, SD 120, respectively; p = 0.007). These results indicate that the nail and end cap insertion angle can be varied within 20° without altering construct stability and that the risk of elastic stable intramedullary nailing push-out can be effectively reduced by the use of end caps.
Resumo:
Acute myeloid leukemia (AML) is characterized by the accumulation of immature blood cell precursors in the bone marrow. Pharmacologically overcoming the differentiation block in this condition is an attractive therapeutic avenue, which has achieved success only in a subtype of AML, acute promyelocytic leukemia (APL). Attempts to emulate this success in other AML subtypes have thus far been unsuccessful. Autophagy is a conserved protein degradation pathway with important roles in mammalian cell differentiation, particularly within the hematopoietic system. In the study described here, we investigated the functional importance of autophagy in APL cell differentiation. We found that autophagy is increased during all-trans-retinoic acid (ATRA)-induced granulocytic differentiation of the APL cell line NB4 and that this is associated with increased expression of LC3II and GATE-16 proteins involved in autophagosome formation. Autophagy inhibition, using either drugs (chloroquine/3-methyladenine) or short-hairpin RNA targeting the essential autophagy gene ATG7, attenuates myeloid differentiation. Importantly, we found that enhancing autophagy promotes ATRA-induced granulocytic differentiation of an ATRA-resistant derivative of the non-APL AML HL60 cell line (HL60-Diff-R). These data support the development of strategies to stimulate autophagy as a novel approach to promote differentiation in AML.
Resumo:
Objective: Minimizing resection and preserving leaflet tissue has been previously shown to be beneficial for mitral valve function and leaflet kinematics after repair of acute posterior leaflet prolapse in porcine valves. We examined the effects of different additional methods of mitral valve repair (neochordoplasty, ring annuloplasty, edge-to-edge repair and triangular resection) on hemodynamics at different heart rates in an experimental model. Methods: Severe acute P2 prolapse was created in eight porcine mitral valves by resecting the posterior marginal chordae. Valve hemodynamics was quantified under pulsatile conditions in an in vitro heart simulator before and after surgical manipulation. Mitral regurgitation was corrected using four different methods of repair on the same valve: neochordoplasty with expanded polytetrafluoroethylene sutures alone and together with ring annuloplasty, edge-to-edge repair and triangular resection, both with non-restrictive annuloplasty. Residual mitral valve leak, trans-valvular pressure gradients, flow and cardiac output were measured at 60 and 80 beats/min. A validated statistical linear mixed model was used to analyze the effect of treatment. The p values were calculated using a two-sided Wald test. Results: Only neochordoplasty with expanded polytetrafluoroethylene sutures but without ring annuloplasty achieved similar hemodynamics compared to those of the native mitral valve (p range 0.071-0.901). Trans-valvular diastolic pressure gradients were within a physiologic range but significantly higher than those of the native valve following neochordoplasty with ring annuloplasty (p=0.000), triangular resection (p=0.000) and edge-to-edge repair (p=0.000). Neochordoplasty alone was significantly better in terms of hemodynamic than neochordoplasty with a ring annuloplasty (p=0.000). These values were stable regardless of heart rate or ring size. Conclusions: Neochordoplasty without ring annuloplasty is the only repair technique able to achieve almost native physiological hemodynamics after correction of leaflet prolapse in a porcine experimental model of acute chordal rupture.
Resumo:
OBJECTIVE Proximal femoral osteotomy with stable fixation and sufficient correction. Low complication rates due to exact preoperative planning. INDICATIONS Congenital or traumatic femoral neck pseudarthrosis. Coxa vara. CONTRAINDICATIONS None. In severe deformities, a single femoral osteotomy may not solve the problem; thus, additional correction, e.g., a pelvic osteotomy, is required. SURGICAL TECHNIQUE Correct planning of the correction angle. Lateral approach. Subperiosteal detachment of vastus lateralis muscle. Place guide wire on the femoral neck to judge anteversion. Insert positioning wire 5 mm distal to trochanteric physis. Insert 2.8 mm Kirschner wire in the femoral neck. Osteotomy of the femur after marking the rotation by Kirschner wires or oscillating saw. Slide LC plate over Kirschner wires. Replace Kirschner wires with screws. Reduction of the femoral shaft to the plate with bone forceps. Definitive fixation of the plate to the femoral shaft by cortex or locking screws. Readaptation of vastus lateralis muscle over the plate. POSTOPERATIVE MANAGEMENT Partial weightbearing for 4-6 weeks depending on the age of the patient without any external fixation (e. g. cast) is possible. RESULTS Recent studies support the authors' findings of sufficient correction and stable fixation after proximal femoral osteotomy with the LCP pediatric hip plate. Low complication rates and stable fixation.
Resumo:
Mechanical properties of human trabecular bone play an important role in age-related bone fragility and implant stability. Micro-finite element (microFE) analysis allows computing the apparent elastic properties of trabecular bone biopsies, but the results depend on the type of applied boundary conditions (BCs). In this study, 167 femoral trabecular cubic biopsies with a side length of 5.3 mm were analyzed using microFE analysis to compare their stiffness systematically with kinematic uniform boundary conditions (KUBCs) and periodicity-compatible mixed uniform boundary conditions (PMUBCs). The obtained elastic constants were then used in the volume fraction and fabric-based orthotropic Zysset-Curnier model to identify their respective model parameters. As expected, PMUBCs lead to more compliant apparent elastic properties than KUBCs, especially in shear. The differences in stiffness decreased with bone volume fraction and mean intercept length. Unlike KUBCs, PMUBCs were sensitive to heterogeneity of the biopsies. The Zysset-Curnier model predicted apparent elastic constants successfully in both cases with adjusted coefficients of determination of 0.986 for KUBCs and 0.975 for PMUBCs. The role of these boundary conditions in finite element analyses of whole bones and bone-implant systems will need to be investigated in future work.
Resumo:
Trabecular bone plays an important mechanical role in bone fractures and implant stability. Homogenized nonlinear finite element (FE) analysis of whole bones can deliver improved fracture risk and implant loosening assessment. Such simulations require the knowledge of mechanical properties such as an appropriate yield behavior and criterion for trabecular bone. Identification of a complete yield surface is extremely difficult experimentally but can be achieved in silico by using micro-FE analysis on cubical trabecular volume elements. Nevertheless, the influence of the boundary conditions (BCs), which are applied to such volume elements, on the obtained yield properties remains unknown. Therefore, this study compared homogenized yield properties along 17 load cases of 126 human femoral trabecular cubic specimens computed with classical kinematic uniform BCs (KUBCs) and a new set of mixed uniform BCs, namely periodicity-compatible mixed uniform BCs (PMUBCs). In stress space, PMUBCs lead to 7–72 % lower yield stresses compared to KUBCs. The yield surfaces obtained with both KUBCs and PMUBCs demonstrate a pressure-sensitive ellipsoidal shape. A volume fraction and fabric-based quadric yield function successfully fitted the yield surfaces of both BCs with a correlation coefficient R2≥0.93. As expected, yield strains show only a weak dependency on bone volume fraction and fabric. The role of the two BCs in homogenized FE analysis of whole bones will need to be investigated and validated with experimental results at the whole bone level in future studies.
Resumo:
Finite element (FE) analysis is an important computational tool in biomechanics. However, its adoption into clinical practice has been hampered by its computational complexity and required high technical competences for clinicians. In this paper we propose a supervised learning approach to predict the outcome of the FE analysis. We demonstrate our approach on clinical CT and X-ray femur images for FE predictions ( FEP), with features extracted, respectively, from a statistical shape model and from 2D-based morphometric and density information. Using leave-one-out experiments and sensitivity analysis, comprising a database of 89 clinical cases, our method is capable of predicting the distribution of stress values for a walking loading condition with an average correlation coefficient of 0.984 and 0.976, for CT and X-ray images, respectively. These findings suggest that supervised learning approaches have the potential to leverage the clinical integration of mechanical simulations for the treatment of musculoskeletal conditions.
Resumo:
BACKGROUND Complex proximal femoral deformities, including an elevated greater trochanter, short femoral neck, and aspherical head-neck junction, often result in pain and impaired hip function resulting from intra-/extraarticular impingement. Relative femoral neck lengthening may address these deformities, but mid-term results of this approach have not been widely reported. QUESTIONS/PURPOSES Do patients who have undergone relative femoral neck lengthening show (1) less hip pain and greater function; (2) improved radiographic parameters; (3) significant complications requiring subsequent surgery; and (4) progression of osteoarthrosis (OA) or conversion to total hip arthroplasty (THA) at mid-term followup? METHODS We retrospectively reviewed 40 patients (41 hips) with isolated relative femoral neck lengthening between 1998 and 2006 with sequelae of Legg-Calvé-Perthes disease (38 hips [93%]), slipped capital femoral epiphysis (two hips [5%]), and postseptic arthritis (one hip [2%]). During this time, the general indications for this procedure included a high-riding greater trochanter with a short femoral neck with abductor weakness and symptomatic intra-/extraarticular impingement. Mean patient followup was 8 years (range, 5-13 years), and complete followup was available in 38 patients (39 hips [95%]). We evaluated pain and function with the impingement test, limp, abductor force, Merle d'Aubigné-Postel score, and range of motion. Radiographic parameters included trochanteric height, alpha angle, and progression of OA. Subsequent surgeries, complications, and conversion to THA were summarized. RESULTS The proportion of positive anterior impingement tests decreased from 93% (38 of 41 hips) preoperatively to 49% (17 of 35 hips) at latest followup (p = 0.002); the proportion of limp decreased from 76% (31 of 41 hips) to 9% (three of 35 hips; p < 0.001); the proportion of normal abductor strength increased from 17% (seven of 41 hips) to 91% (32 of 35 hips; p < 0.001); mean Merle d'Aubigné-Postel score increased from 14 ± 1.7 (range, 9-17) to 17 ± 1.5 (range, 13-18; p < 0.001); mean internal rotation increased to 25° ± 15° (range, 0°-60°; p = 0.045), external rotation to 32° ± 14° (range, 5°-70°; p = 0.013), and abduction to 37° ± 13° (range, 10°-50°; p = 0.004). Eighty percent of hips (33 of 41 hips) showed normal trochanteric height; alpha angle improved to 42° ± 10° (range, 27°-90°). Two hips (5%) had subsequent surgeries as a result of lack of containment; four of 41 hips (10%) had complications resulting in reoperation. Fourteen of 35 hips (40%) showed progression of OA; four of 40 hips (10%) converted to THA. CONCLUSIONS Relative femoral neck lengthening in hips with combined intra- and extraarticular impingement results in reduced pain, improved function, and improved radiographic parameters of the proximal femur. Although lack of long-term complications is gratifying, progression of OA was not prevented and remains an area for future research.