970 resultados para tandem repeat


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The gender diagnosticity (GD) approach of Lippa (1995) was used to evaluate the relationship of within-sex differences in psychological masculinity-femininity to a genetic characteristic, the length of a repeated CAG sequence in the X-linked androgen receptor (AR) gene. Previously assessed adult samples in Australia and Sweden were used for this purpose. A weak relationship (correlations in the range .11 to .14) was obtained in both countries. Additional data from adolescent twins from Australia (12-, 14-, 16-year-olds) did not confirm such a relationship at those ages, especially for males. The fact that this sample consisted of twins permitted two kinds of within-pair comparisons: (1) Did the dizygotic twin who had the longer AR sequence have the higher GD score? (2) Was one twin's GD score more highly correlated with the other twin's AR score in MZ than in DZ pairs? The answer in both cases was negative. Clarification of these relationships will require large samples and measurements at additional ages.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The authors describe a reverse-phase high-performance liquid chromatography-electrospray-tandem mass spectrometry method for the measurement of nicotine in human plasma. Samples (500 muL) with added deuterium-labeled d(3)-nicotine as an internal standard (IS) were treated with a 2-step process of ether extraction (6 mL) followed by back-extraction into 0.1% formic acid (50 muL). Chromatography was performed on a phenyl Novapak column with a mobile phase consisting of 50% 10 mM ammonium fortriate (pH 3.3) and acetonitrile (50:50, vol/vol). A flow rate of 0.2 mL/min resulted in a total analysis time of 5 minutes per sample. Mass spectrometric detection was by selected reactant monitoring (nicotine m/z 163.2 --> 130.2; IS m/z 166.2 --> 87.2). The assay was linear from 0.5 to 100 mug/L (r > 0.993, n = 9). The accuracy and imprecision of the method for quality control sampleswere 87.5% to 113% and < 10.2%, respectively. Interday accuracy and imprecision at the limit of quantification (0.5 mug/L) was 113% and 7.2% (n = 4). The process efficiency for nicotine in plasma was > 75%. The method described has good process efficiency, stabilized nicotine, avoided concentration steps, and most importantly minimized potential contamination. Further, we have established that water-based standards and controls are interchangeable with plasma-based samples. This method was used successfully to measure the pharmacokinetic profiles of subjects involved in the development of an aerosol inhalation drug delivery system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An analysis of the historic H1 subtype, H1-1, in eight legumes belonging to four genera of the tribe Vicieae (Pisum, Lathyrus, Lens, and Vicia), revealed an extended region consisting of the tandemly repeated AKPAAK motifs. We named this region the Regular zone (RZ). The AKPAAK motifs are organized into two blocks separated by a short (two or six amino acids) intervening sequence (IS). The distal block contains six AKPAAK motifs, while the number of repeats in the proximal block varies from six in V. faba to seven in the other species. In V. hirsuta, the first two repeated units of the proximal block are octapeptides AKAKPAAK. The apparent rate of synonymous substitutions in the blocks of RZ is much higher than in the rest of the gene. This can be explained by repeat shuffling within each block. In the C-domain of the orthologous H1 subtype froth Medicago truncatula (tribe Trifolieae), a region corresponding to the RZ of Vicieae species was found. It also consists of two blocks of AKPAAK motifs (four and three repeats in the proximal and distal blocks, respectively). These blocks are separated by a 20-amino acid IS. The first 20 amino acids of the Medicago RZ are not part of AKPAAK repeats. We hypothesise that the RZ has most probably evolved as a result of an expansion of AKPAAK repeats from two separate sites in the C-domain. This process started tens of millions of years ago and was most likely directed by positive selection.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Kennedy's disease (spinobulbar muscular atrophy) is an X-linked form of motor neuron disease affecting adult males carrying a CAG trinucleotide repeat expansion within the androgen receptor gene. While expression of Kennedy's disease is thought to be confined to males carrying the causative mutation, subclinical manifestations have been reported in a few female carriers of the disease. The reasons that females are protected from the disease are not clear, especially given that all other diseases caused by CAG expansions display dominant expression. In the current study, we report the identification of a heterozygote female carrying the Kennedy's disease mutation who was clinically diagnosed with motor neuron disease. We describe analysis of CAG repeat number in this individual as well as 33 relatives within the pedigree, including two male carriers of the Kennedy's mutation. The female heterozygote carried one expanded allele of the androgen receptor gene with CAG repeats numbering in the Kennedy's disease range (44 CAGs), with the normal allele numbering in the upper-normal range (28 CAGs). The subject has two sons, one of whom carries the mutant allele of the gene and has been clinically diagnosed with Kennedy's disease, whilst the other son carries the second allele of the gene with CAGs numbering in the upper normal range and displays a normal phenotype. This coexistence of motor neuron disease and the presence of one expanded allele and one allele at the upper limit of the normal range may be a coincidence. However, we hypothesize that the expression of the Kennedy's disease mutation combined with a second allele with a large but normal CAG repeat sequence may have contributed to the motor neuron degeneration displayed in the heterozygote female and discuss the possible reasons for phenotypic expression in particular individuals.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To compare the effectiveness and safety of repeat treatment with hylan G-F 20 based on data from a randomized, controlled trial [Raynauld JP, Torrance GW, Band PA, Goldsmith CH, Tugwell P, Walker V, et al. A prospective, randomized, pragmatic, health outcomes trial evaluating the incorporation of hylan G-F 20 into the treatment paradigm for patients with knee osteoarthritis (Part 1 of 2): clinical results. Osteoarthritis Cartilage 2002;10:506-17]. The hypotheses tested were whether the single-course and repeat-course subgroups would be superior to appropriate care and not different from each other. Method: A total of 255 patients with knee osteoarthritis were randomized to appropriate care with hylan G-F 20 or appropriate care without hylan G-F 20. The hylan G-F 20 group was partitioned into two subgroups: (1) patients who received a single course of hylan G-F 20; and (2) patients who received two or more courses of hylan G-F 20. Results: For the primary effectiveness measure, change in Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) pain score as a percent of baseline, the single-course subgroup improved by 41%, the repeat-course subgroup by 35%, and the appropriate care group by 14%. Both subgroups improved significantly more than the appropriate care group (P < 0.05), and were not statistically significantly different from each other (70% power to detect a 20% difference). Secondary effectiveness measures showed similar results. In the repeat-course subgroup, no statistically significant differences were found in the number of local adverse events, the number of patients with local adverse events, or arthrocentesis rates between the first and repeat courses of treatment. Conclusions: Although the study was neither designed nor powered to examine repeat treatment, this a posteriori analysis provides support for a favorable effectiveness and safety profile of hylan G-F 20 in repeat course patients. (C) 2004 OsteoArthritis Research Society International. Published by Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An assay using high performance liquid chromatography (HPLC)-electrospray ionization-tandem mass spectrometry (ESI-MS-MS) was developed for simultaneously determining concentrations of morphine, oxycodone, morphine-3-glucuronide, and noroxycodone, in 50 mul samples of rat serum. Deuterated (d(3)) analogues of each compound were used as internal standards. Samples were treated with acetonitrile to precipitate plasma proteins: acetonitrile was removed from the supernatant by centrifugal evaporation before analysis. Limits of quantitation (ng/ml) and their between-day accuracy and precision (%deviation and %CV) were-morphine, 3.8 (4.3% and 7.6%); morphine-3-glucuronide, 5.0 (4.5% and 2.9%); oxycodone, 4.5 (0.4% and 9.3%); noroxycodone, 5.0 (8.5% and 4.6%). (C) 2004 Elsevier B.V. All rights reserved.