933 resultados para subcritical assemblies


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Thermal spray WC-based coatings are widely used in the aircraft industry mainly for their resistance to wear, reworking and rebuilding operations and repair of worn components on landing gear, hydraulic cylinders, actuators, propeller hub assemblies, gas turbine engines, and so on. The aircraft industry is also trying to use thermal spray technology to replace electroplating coatings such as hard chromium. In the present work, WC-Co coatings were built up on an AA 7050 aluminum alloy using high velocity oxygen fuel (HVOF) technology and a liquid nitrogen cooling prototype system. The influence of the spray parameters (standard conditions, W19S, increasing the oxygen flux, W19H, and also increasing the carrier gas flux, W19F) on corrosion, friction, and abrasive wear resistance were also studied. The coatings were characterized using optical (OM) and scanning electron (SEM) microscopy, and X-ray diffraction (XRD). The friction and abrasive wear resistance of the coatings were studied using Rubber Wheel and Ball on Disk tests. The electrochemical studies were conducted using open-circuit potential (E(oc)) measurements and electrochemical impedance spectroscopy (EIS). Differences among coated samples were mainly related to the variation of the thermal spray parameters used during the spray process. No significant differences were observed in the wear resistance for the coatings studied, and all of them showed a wear rate around 10 times lower than that of the aluminum alloy. The results of mass loss and wear rate were interpreted considering different mechanisms. Comparing the different spray parameters, the oxygen flux (higher flame temperature) produced the sample which showed the highest corrosion resistance in aerated and unstirred 3.5% NaCl solution. Aluminum ions were detected on the surface almost immediately after the immersion of samples W19S and W19F in chloride solution, showing that the electrolyte reached the substrate and galvanic corrosion probably occurred. For sample W19H, aluminum ions were not detected even after 120 min of immersion in NaCl solution. (C) 2008 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A series of alkyl sulfate detergents has been investigated in the presence of the cations Na +, methylviologen(2+) (MV 2+), 4-(cyanomethyl)pyridinium(1+) (CMP +), and tetramethylammonium (TMA +). The binding of these ions to the aqueous micellar assemblies has been measured through studies of luminescence quenching with the extramicellar probe, RuL 34-, where L = 4,4′-dicarboxy-2,2′-bipyridine. A general comparison of the alkyl sulfate aggregates with the nonquenching cations Na + and TMA + shows that the latter ion reduces the critical micelle concentration but at the same time depresses the ability of the detergent assemblies to bind or solubilize the hydrophobic quencher cations MV 2+ or CMP +. The reduced binding ability of the TMA + aggregates compared to that of the corresponding Na + soaps shows up largely in the form of a reduced favorable ΔS° for the solubilization in the case of the former. The results are in accord with a picture of the TMA + micelle as being more stable and more disordered than the corresponding assembly with Na + as the counterion. © 1989 American Chemical Society.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

As the adaptation of titanium crowns obtained by Rematitan Plus investment, specific for titanium, is not recognized to be suitable, this study evaluated the effect of the concentration of the specific liquid and the temperature of the mold of investments on the internal misfit of crowns cast on commercially pure titanium. Individual dies of epoxy resin were obtained, representing teeth prepared for full-crown restoration with a 6-degree axial surface convergence angle and shoulder (1.0 mm). For the waxing of each crown, a ring-shaped stainless steel matrix (8.0mm internal diameter; 7.5 mm height) was adapted above the individual dies of epoxy resin. The Rematian Plus investment was mixed according to the manufacturer's instructions using two different concentrations of the specific liquid: 100%, 75%. Casting was performed in a Discovery Plasma Ar-arc vacuum-pressure casting machine with molds at temperatures of 430°C, 515°C and 600°C. The crowns were cleaned individually in a solution (1% HF + 13% HNO3) for 10 min using a ultrasonic cleaner, with no internal adaptations, and luted with zinc phosphate cement under a 5 kg static load. The crown and die assemblies were embedded in resin and sectioned longitudinally. The area occupied by cement was observed using stereoscopic lens (10X) and measured by the Leica Qwin image analysis system (mm2). The data for each experimental condition (n=8) were analyzed by Kruskal-Wallis non-parametric test (á=0.05). The results showed that liquid dilution and the increase in mold temperature did not significantly influence the levels of internal fit of the cast titanium crowns. The lowest means (±SD) of internal misfit were obtained for the 430°C/100%: (7.25 mm2 ±1.59) and 600°C/100% (8.8 mm2 ±2.25) groups, which presented statistically similar levels of internal misfit.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study compared the bond strength durability of a feldspathic veneering ceramic to glass-infiltrated reinforced ceramics in dry and aged conditions. Disc shaped (thickness: 4 mm, diameter: 4 mm) of glass-infiltrated alumina (In-Ceram Alumina) and glass-infiltrated alumina reinforced by zirconia (In-Ceram Zirconia) core ceramic specimens (N=48, N=12 per groups) were constructed according to the manufacturers' recommendations. Veneering ceramic (VITA VM7) was fired onto the core ceramics using a mold. The core-veneering ceramic assemblies were randomly divided into two conditions and tested either immediately after specimen preparation (Dry) or following 30000 thermocycling (5-55 oC±1; dwell time: 30 seconds). Shear bond strength test was performed in a universal testing machine (cross-head speed: 1 mm/min). Failure modes were analyzed using optical microscope (x20). The bond strength data (MPa) were analyzed using ANOVA (α=0.05). Thermocycling did not decrease the bond strength results for both In-Ceram Alumina (30.6±8.2 MPa; P=0.2053) and In-Ceram zirconia (32.6±9 MPa; P=0.3987) core ceramic-feldspathic veneering ceramic combinations when compared to non-aged conditions (28.1±6.4 MPa, 29.7±7.3 MPa, respectively). There were also no significant differences between adhesion of the veneering ceramic to either In-Ceram Alumina or In-Ceram Zirconia ceramics (P=0.3289). Failure types were predominantly a mixture of adhesive failure between the veneering and the core ceramic together with cohesive fracture of the veneering ceramic. Long-term thermocycling aging conditions did not impair the adhesion of the veneering ceramic to the glass-infiltrated alumina core ceramics tested.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This classical way to manage product development processes for massive production seems to be changing: high pressure for cost reduction, higher quality standards, markets reaching for innovation lead to the necessity of new tools for development control. Into this, and learning from the automotive and aerospace industries factories from other segments are starting to understand and apply manufacturing and assembly oriented projects to ease the task of generate goods and from this obtain at least a part of the expected results. This paper is intended to demonstrate the applicability of the concepts of Concurrent Engineering and DFM/DFA (Design for Manufacturing and Assembly) in the development of products and parts for the White Goods industry in Brazil (major appliances as refrigerators, cookers and washing machines), showing one case concerning the development and releasing of a component. Finally is demonstrated in a short term how was reached a solution that could provide cost savings and reduction on the time to delivery using those techniques.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Ant assemblages are almost all related with the vegetation composition and so can provide us important information for conservation strategies, which are especially relevant to an environmentally protected area. We sampled the ant fauna in three different phytophysionomies in order to verify if the composition of ant species is different among the areas, especially because one of the areas is a Rocky Field and there is little information about the ant fauna in this habitat. A total of 8730 individuals were registered and an NMDS analysis showed that the ant assemblies are different at the three phytophysionomies (Rocky Field, Riparian Forest, and Secondary Forest). This study shows that the species that compose the ant assemblies in different phytophysionomies are a reflex of the environment, supporting the hypothesis that the vegetational composition results in different compositions in the ant assembly. Vegetal composition is determinant in the formation of the litter and consequently in the occurrence of ant species that depend on this layer of organic matter for nesting and foraging. © 2012 Juliane Floriano Santos Lopes et al.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives: The aim of this study was to evaluate the effect of different seating forces during cementation in cement-ceramic microtensile bond strength (μTBS). Materials and methods: Forty-five blocks (5 × 5 × 4 mm3) of a glass-infiltrated alumina-based ceramic (In-Ceram Alumina) were fabricated according to the manufacturer's instructions and duplicated in resin composite. Ceramic surfaces were polished, cleaned for 10 min in an ultrasonic bath, silica coated using a laboratory type of air abrasion device, and silanized. Each treated ceramic block was then randomly assigned to five groups (n = 9) and cemented to a composite block under five seating forces (10 g, 50 g, 100 g, 500 g, and 750 g) using a dual-cured resin cement (Panavia F). The ceramic-cement-composite assemblies were cut under coolant water to obtain bar specimens (1 mm × 0. 8 mm2). The μTBS tests were performed in a universal testing machine (1 mm/min). The mean bond strengths values were statistically analyzed using one-way ANOVA (α ≤ 0. 05). Results: Different seating forces resulted in no significant difference in the μTBS results ranging between 13. 1 ± 4. 7 and 18. 8 ± 2. 1 MPa (p = 0. 13) and no significant differences among cement thickness. Conclusions: Excessive seating forces during cementation seem not to affect the μTBS results. Clinical relevance: Excessive forces during the seating of single all-ceramic restorations cementation seem to display the same tensile bond strength to the resin cement. © 2012 Springer-Verlag.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The electrochemical behavior of polystyrene modified with gold nanoparticle (Au NPs) was investigated in terms of pH-responsive polymer brush. A pH-responsive of modified polymer brush from tethered polystyrene was prepared and used for selective gating transport of anions andcations across the thin-film. An ITO-coated glass electrode was used as substrate and applied to study the switchable permeability of the polymer brush triggered by changes in pH of the aqueous environment. The pH-sensitive behavior of the polymer brush interface has been demonstrated by means of cyclic voltammetry (CV) and Localized Surface Plasmon Resonance (LSPR). CV experiments showed at ph values of 4 and 8 induces swelling and shrinking of the grafted polymer brushes, respectively, and this behavior is fast and reversible. LSPR measurements showed a blue shift of 33 nm in the surface resonance band changes by local pH. The paper brings an easy methodology to fabrication a variety of nanosensors based on the polymer brushes-nanoparticle assemblies. © 2013 by ESG.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

After 20 years of reestablished democracy in Brazil, what do the state legislators think about the regime? The goal of the article is to show the views of state legislators of the Legislative Assemblies of the States of São Paulo and Paraná on democracy. For the views we use a structured and self-administered questionnaire. The results show that for the state legislators: i) democracy is stable, ii) it is superior to any other kind of regime, iii) it's support comes from some public policy and the use of voting and iv) parties and elections are important for democracy.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Estudos Linguísticos - IBILCE

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Ciência da Computação - IBILCE

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Educação - IBRC