980 resultados para sequential reduction processes
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Copyright © 2014 The Authors. Oikos © 2014 Nordic Society Oikos.
Resumo:
Tese de Doutoramento, Física, 17 de Dezembro de 2013, Universidade dos Açores.
Resumo:
The replacement of conventional synthetic films and coatings by biodegradable alternatives reduces the use of non-renewable resources and waste disposal problems. Considering that Portugal is a major producer of leather, and consequently a large producer of related wastes, in this research, bovine hair was tested for the production of biodegradable films directly by thermo-compression, allowing waste valorisation and reduction of environmental pollution. The aim of this study was to determine the influence of the different pre-treatments performed by two processes (removal by mechanical action and removal by chemical process), applied to bovine hair, in order to obtain a biodegradable film with appropriate properties. Mechanical properties for these films were evaluated, namely strain at break, stress at break and Young modulus. Additionally colour, solubility and swelling in water were also studied. The mechanical removal hair only produced films with Na2S treatment. Chemical removed hair (immunization) depends of the pre-treatment and the degreasing with petroleum ether or sodium sulphide pre-treatment leads better mechanical properties. The results obtained indicated that the pre-treatments have an important role in the final properties of biodegradable films.
Resumo:
Mestrado em Engenharia Mecânica. Gestão de Processos e Operações.
Resumo:
Mestrado em Engenharia Química. Ramo Tecnologias de Protecção Ambiental.
Resumo:
Os objectivos principais deste estudo são a caracterização de uma das linhas de extrusão existentes na Cabelte, nomeadamente a linha de extrusão de referência EP5, composta por duas extrusoras. Pretende-se fazer a determinação de indicadores energéticos e de processo e a optimização do consumo energético, no que diz respeito à energia consumida e às perdas térmicas relativas a esta linha. Para fazer a monitorização da linha de extrusão EP5 foi colocado no quadro geral dessa linha um equipamento central de medida de forma a ser possível a sua monitorização. No entanto, para a extrusora auxiliar as medições foram efectuadas com uma pinça amperimétrica e um fasímetro. Foram também efectuados ensaios onde foi avaliada a quantidade de material transformada, para isso foi utilizado um equipamento de pesagem, doseador gravimétrico aplicado nas extrusoras. As medições de temperatura para os cálculos das perdas térmicas da extrusora principal e para a caracterização dos materiais plásticos, foram efectuadas utilizando um termómetro digital. Foram efectuados ensaios de débito às extrusoras auxiliar e principal e foi estudada a variação do factor de potência em função da rotação do fuso. Na perspectiva do utilizador final a optimização para a utilização racional de energia está na redução de encargos da factura de energia eléctrica. Essa factura não depende só da quantidade mas também do modo temporal como se utiliza essa energia, principalmente a energia eléctrica, bastante dependente do período em que é consumida. Uma metodologia diferente no planeamento da produção, contemplando o fabrico dos cabos com maior custo específico nas horas de menor custo energético, implicaria uma redução dos custos específicos de 18,7% para o horário de verão e de 20,4% para o horário de inverno. Os materiais de revestimento utilizados (PE e PVC), influenciam directamente os custos energéticos, uma vez que o polietileno (PE) apresenta sempre valores de entalpia superiores (0,317 kWh/kg e 0,281 kWh/kg)) e necessita de temperaturas de trabalho mais elevadas do que o policloreto de vinilo (PVC) (0,141 kWh/kg e 0,124 kWh/kg). O consumo específico tendencialmente diminui à medida que aumenta a rotação do fuso, até se atingir o valor de rotação óptimo, a partir do qual esta tendência se inverte. O cosφ para as duas extrusoras em estudo, aumenta sempre com o aumento de rotação do fuso. Este estudo permitiu avaliar as condições óptimas no processo de revestimento dos cabos, de forma a minimizarmos os consumos energéticos. A redução de toda a espécie de desperdícios (sobre consumos, desperdício em purgas) é uma prioridade de gestão que alia também a eficácia à eficiência, e constitui uma ferramenta fundamental para assegurar o futuro da empresa. O valor médio lido para o factor de potência (0,38) da linha EP5, valor extremamente baixo e que vem associado à energia reactiva, além do factor económico que lhe está inerente, condiciona futuras ampliações. A forma de se corrigir o factor de potência é instalando uma bateria de condensadores de 500 kVAr. Considerando o novo sistema tarifário aplicado à energia reactiva, vamos ter um ganho de 36167,4 Euro/ano e o período de retorno de investimento é de 0,37 ano (4,5 meses). Esta medida implica também uma redução anual na quantidade de CO2 emitida de 6,5%. A quantificação das perdas térmicas é importante, pois só desta forma se podem definir modos de actuação de forma a aumentar a eficiência energética. Se não existir conhecimento profundo dos processos e metodologias correctas, não podem existir soluções eficientes, logo é importante medir antes de avançar com qualquer medida de gestão.
Resumo:
O meio ambiente é uma grande preocupação mundial existindo cada vez mais imposições legais no sentido de o proteger. Torna-se assim necessário que as indústrias adoptem e desenvolvam processos alternativos mais limpos. A indústria de curtumes transforma a pele animal em couro, material resistente à putrefacção e com estabilidade térmica suficiente para ser manufacturado nas indústrias do calçado, estofos, vestuário e marroquinaria. A transformação referida é efectuada através duma série de processos entre os quais o caleiro, processo que visa depilar a pele e promover o relaxamento da estrutura fibrilar, tem um papel importante. O processo de caleiro produz um efluente bastante poluente. Tendo em conta esse facto, este trabalho teve como objectivo desenvolver processos de depilação de pele caprina sem destruição do pêlo, com vista à redução da quantidade de sulfureto e sulfidrato de sódio utilizada e da carga poluente do efluente. Além disso, o processo permite a recuperação do pêlo e este pode ser reaproveitado como fertilizante orgânico, hidrolisado de queratina, compostagem, etc. Todo o trabalho foi realizado tomando por base um processo de caleiro padrão utilizado industrialmente, alterando-o de forma a obter um processo de caleiro óptimo de depilação sem destruição do pêlo com e sem utilização de enzimas. Numa primeira fase, desenvolveu-se um processo de depilação sem destruição do pêlo normalmente utilizado para a pele de bovino que foi adaptado com resultados positivos, designado de processo sem enzimas. Numa segunda fase, desenvolveu-se um processo enzimático em que se utilizou uma protease (Erhavit DMC), uma lipase (Defat 50) e uma amilase (Mayzme SD-L); este processo deu bons resultados tal como o anterior. A redução da quantidade de sulfureto de sódio foi de 33% e 53% para o processo sem enzimas e processo com enzimas, respectivamente, em relação ao processo padrão. O efeito dos processos na carga poluente, à escala piloto, comprova uma redução de 37% nos SST, 37% nos SDT, 60% na CQO, 9% no S2- e 73% no Azoto para o processo sem enzimas e uma redução de 93% nos SST, 63% nos SDT, 69% na CQO, 69% no S2- e 83% no Azoto para o processo com enzimas, quando comparados com o processo padrão. . Uma análise de custos, com incidência apenas nos agentes químicos utilizados, permitiu concluir a existência de uma redução de custos anuais de 30% para o processo com enzimas e de 13% para o processo sem enzimas, quando comparados com o processo padrão. Como conclusão, os processos desenvolvidos apresentam um grande potencial para serem explorados industrialmente.
Resumo:
Este trabalho na área dos processos físicos de separação por membranas, nomeadamente, a nanofiltração (NF), tem como objectivo principal a recuperação dos efluentes resultantes das águas da 3ª lavagem utilizadas na operação de tingimento de fibras de algodão, com corantes reactivos. Estão inerentes as problemáticas: da escassez da água como matéria-prima na vertente de água potável; da diminuição de efluentes que necessitam de tratamentos devido à sua carga poluente; da recuperação sempre que seja viável dos produtos químicos adicionados nesta fase de tratamento das fibras de algodão e por último e não menos importante, da energia contida nestes efluentes que vão para o esgoto a temperaturas na ordem dos 50 ºC. A metodologia adoptada na realização deste trabalho consistiu, inicialmente num estudo sobre os trabalhos realizados até hoje nesta área, seguindo-se a recolha dos efluentes na empresa ―Estamparia Têxtil Adalberto Pinto da Silva, S.A.‖ (ETAPS) e posterior estudo da recuperação dos efluentes em causa pelo processo de NF utilizando a membrana NF270-2540 da empresa FILMTEC. Os efluentes estudados no presente trabalho continham corantes reactivos sendo um corante azul-claro (CAC) de composição (Amarelo Bril Remazol GL 150% + Azul Brilhante Remazol BB 133% + Azul Turqueza Remazol G) e o outro corante azul-marinho (CAM) de composição (Preto Remazol B 133% + Vermelho Remazol RGB + Amarelo Ouro Remazol RGB). Estes estudos de recuperação compreenderam basicamente 3 fases: caracterização do efluente recolhido na empresa; tratamento desse efluente utilizando uma instalação piloto de NF de fluxo cruzado ou também conhecido por membrana de fluxo tangencial instalado no Laboratório de Tecnologia (LT) do Instituto Superior de Engenharia do Porto (ISEP), e caracterização dos permeados e dos rejeitados obtidos. A análise de resultados do presente trabalho permitiu concluir ser possível a recuperação e reutilização das 3ª águas de lavagem do processo de tingimento quando tratadas pelo processo de NF a pressões de operação de 6 bar. Nestas circunstâncias os permeados obtidos (tanto no efluente com corante azul-claro como no efluente com corante azul-marinho) apresentam valores, em todos os parâmetros estudados, significativamente abaixo dos valores limites recomendáveis para uma água de abastecimento na Industria Têxtil (IT). Salienta-se reduções mais expressivas nos permeados do corante CAM, com vários parâmetros a sofrerem reduções no intervalo de 98 a 100%, nomeadamente, na cor, turvação, CQO, dureza total, alumínio e manganês. Os resultados obtidos para as pressões de operação de 4 e 8 bar mostram alguns parâmetros com valores acima dos recomendados para uma água de abastecimento na Indústria Têxtil, nomeadamente a cor no corante CAC quando se opera a 4 bar e no corante CAM quando se opera a 8 bar e os sulfatos e ferro no CAM à pressão de 4 bar. Estes resultados mostram ser possível a reutilização da água na própria instalação industrial, trazendo um benefício económico e ambiental, pela redução no consumo de água fresca e energia, além da redução do volume de efluentes que necessitam ser tratados, estando na mesma linha de pensamento de Gross et al (1999), que refere que o uso de membranas para o tratamento de efluentes do processo de tingimento tem como principal objectivo a viabilidade económica, a redução no consumo de água, de sais, de corantes e energia, bem como, a redução do volume de efluentes a ser tratado.
Resumo:
The presented work was conducted within the Dissertation / Internship, branch of Environmental Protection Technology, associated to the Master thesis in Chemical Engineering by the Instituto Superior de Engenharia do Porto and it was developed in the Aquatest a.s, headquartered in Prague, in Czech Republic. The ore mining exploitation in the Czech Republic began in the thirteenth century, and has been extended until the twentieth century, being now evident the consequences of the intensive extraction which includes contamination of soil and sub-soil by high concentrations of heavy metals. The mountain region of Zlaté Hory was chosen for the implementation of the remediation project, which consisted in the construction of three cells (tanks), the first to raise the pH, the second for the sedimentation of the formed precipitates and a third to increase the process efficiency in order to reduce high concentrations of metals, with special emphasis on iron, manganese and sulfates. This project was initiated in 2005, being pioneer in this country and is still ongoing due to the complex chemical and biological phenomenon’s inherent to the system. At the site where the project was implemented, there is a natural lagoon, thereby enabling a comparative study of the two systems (natural and artificial) regarding the efficiency of both in the reduction/ removal of the referred pollutants. The study aimed to assist and cooperate in the ongoing investigation at the company Aquatest, in terms of field work conducted in Zlaté Hory and in terms of research methodologies used in it. Thereby, it was carried out a survey and analysis of available data from 2005 to 2008, being complemented by the treatment of new data from 2009 to 2010. Moreover, a theoretical study of the chemical and biological processes that occurs in both systems was performed. Regarding the field work, an active participation in the collection and in situ sample analyzing of water and soil from the natural pond has been attained, with the supervision of Engineer, Irena Šupiková. Laboratory analysis of water and soil were carried out by laboratory technicians. It was found that the natural lagoon is more efficient in reducing iron and manganese, being obtained removal percentages of 100%. The artificial lagoon had a removal percentage of 90% and 33% for iron and manganese respectively. Despite the minor efficiency of the constructed wetland, it must be pointed out that this system was designed for the treatment and consequent reduction of iron. In this context, it can conclude that the main goal has been achieved. In the case of sulphates, the removal optimization is yet a goal to be achieved not only in the Czech Republic but also in other places where this type of contamination persists. In fact, in the natural lagoon and in the constructed wetland, removal efficiencies of 45% and 7% were obtained respectively. It has been speculated that the water at the entrance of both systems has different sources. The analysis of the collected data shows at the entrance of the natural pond, a concentration of 4.6 mg/L of total iron, 14.6 mg/L of manganese and 951 mg/L of sulphates. In the artificial pond, the concentrations are 27.7 mg/L, 8.1 mg/L and 382 mg/L respectively for iron, manganese and sulphates. During 2010 the investigation has been expanded. The study of soil samples has started in order to observe and evaluate the contribution of bacteria in the removal of heavy metals being in its early phase. Summarizing, this technology has revealed to be an interesting solution, since in addition to substantially reduce the mentioned contaminants, mostly iron, it combines the low cost of implementation with an reduced maintenance, and it can also be installed in recreation parks, providing habitats for plants and birds.
Resumo:
Trabalho de Projecto de natureza científica para obtenção do grau de Mestre em Engenharia Civil
Resumo:
O Electronic Data Interchange (EDI) oferece um vasto leque de oportunidades para as empresas se tornarem mais competitivas. Não só na ótica dos processos de negócio de bens e serviços, como nas práticas organizacionais e de gestão. A adoção de tecnologias de informação e comunicação do comércio eletrónico B2B, visando o aumento da eficácia e eficiência na troca de documentos de negócio, possibilita a melhoria da colaboração entre agentes económicos de uma cadeia produtiva de bens ou serviços. O comércio eletrónico permitiu uma profunda transformação das práticas comerciais tradicionais, onde o EDI influenciou positivamente na forma de conduzir o negócio. Um conceito atualmente emergente é o de fatura eletrónica, essencial para o desenvolvimento da relação entre entidades (B2B). A desmaterialização da fatura acarreta inúmeros benefícios para as entidades envolvidas, tais como: a redução de custos, a redução do impacto ambiental e o aumento da produtividade e da transparência nos processos de negócio. Esta dissertação pretende abordar em detalhe as temáticas referentes ao EDI e à fatura eletrónica, no que concerne ao conceito, às mensagens, aos standards utilizados, aos benefícios e custos envolvidos, e a toda a sua envolvência ao longo de uma cadeia de abastecimento. Com base nestes conceitos, é apresentado um caso de estudo de sucesso na empresa nacional Sonae®, que pretende abordar todo o programa EDI da empresa. O esforço despendido na implementação do programa e na adoção da fatura eletrónica legal na Sonae® supera em larga escala os objetivos pretendidos, devido aos benefícios inerentes à utilização do EDI. A fatura eletrónica representa não só o conceito de troca de documentos via eletrónica, como também uma nova forma de conduzir os negócios.
Resumo:
Os produtos farmacêuticos são substâncias químicas muito utilizados em medicina, veterinária e ainda na agricultura. Nos anos 90, foi descoberta a presença de fármacos em meio aquático, verificando-se que a sua remoção nas Estações de Tratamento de Águas Residuais (ETAR) não era completa. Durante as duas últimas décadas foi identificada a presença de mais de oitenta compostos no meio ambiente e actualmente são considerados poluentes emergentes. Podem contaminar solos e águas, depois de serem usados e excretados (inalterados ou metabolizados) por humanos e animais, ou quando são indevidamente lançados directamente no meio ambiente. Os estudos ecotoxicológicos efectuados com estes poluentes têm sido direccionados, sobretudo, para as águas, existindo uma ausência de trabalhos sobre solos. O Ibuprofeno (IB) é um anti-inflamatório não esteróide, utilizado também como analgésico e antipirético, sendo um dos produtos farmacêuticos mais vendidos em todo o mundo, o que justifica a sua forte presença no meio ambiente. Por isso, e dada a ausência de trabalhos ecotoxicológicos de solos contaminados por fármacos, o IB foi o produto farmacêutico selecionado para a realização deste trabalho. A ecotoxicidade pode ser avaliada através de bioensaios. Estes têm a capacidade de avaliar a toxicidade de uma determinada substância de forma global, usando organismos vivos que funcionam como bio-indicadores. O presente trabalho tem como objectivos avaliar o impacte causado nos solos pelo IB, testar a toxicidade de dois processos de descontaminação para remover o referido fármaco dos solos assim como avaliar a toxicidade provocada por águas residuais, de três unidades hospitalares e de uma indústria farmacêutica. Esta avaliação foi efectuada através de ensaios de toxicidade aguda de germinação e de alongamento de raiz de sementes de alface, variedade bola de manteiga (Lactuca sativa), em solo arenoso. Os ensaios de ecotoxicidade aguda em solos contaminados por IB foram realizados para uma gama de concentrações entre 0,1 e 1000 μg/L. Verificou-se uma redução do número de sementes germinadas e do comprimento médio da planta no solo contaminado com 0,5 e 20 μg/L de IB. No solo contaminado com 1000 μg/L de IB observou-se uma redução da germinação, acompanhada por uma indução de crescimento da raiz da espécie Lactuca sativa. Os dois tratamentos de descontaminação de solos, reagente de Fenton e Nanopartículas de ferro zero valente, revelaram toxicidade, tendo-se obtido uma percentagem de germinação entre 32,2 ± 3,5 e 48,5 ± 6,2 e inibição do crescimento da raiz do organismo teste em cerca de 85,0 %. Em relação às águas residuais hospitalares verificou-se uma redução da percentagem de germinação entre 31,1 ± 5,0 e 72,3 ± 12,4 e uma inibição do crescimento da raiz situada entre 13,0 ± 6,4 e 20,2 ± 10,0 %. Para a água residual industrial ocorreu uma inibição da percentagem de germinação de 60,5 ± 13,1, contudo nas plantas germinadas observou-se uma indução do crescimento da raiz de 14,9 ± 7,7 %.
Resumo:
A Mundotêxtil foi fundada em 1975 tendo iniciado a sua actividade na área comercial de produtos têxteis. Actualmente é o maior produtor nacional de atoalhados de felpo e emprega 575 colaboradores. Como resultado do seu crescimento e sobretudo da actividade de tingimento de fio e felpo, as necessidades de água são consideráveis e o volume de efluentes gerados nos processos industriais é cada vez maior a empresa avançou com a construção de uma estação de tratamento por lamas activadas, colocando-a em funcionamento em Setembro de 2004. Inicialmente surgiram dificuldades para a remoção da cor e da concentração da Carência Química de Oxigénio (CQO) de modo a cumprir os limites máximos de emissão permitidos nas normas de descarga no rio Ave e no Decreto-Lei nº 236/98, de 1 de Agosto. Com a descarga de parte dos efluentes no SIDVA e a utilização de um coagulante adicionado ao reactor o tratamento passou a apresentar melhores resultados. O intuito deste trabalho é o de apresentar soluções de modo a optimizar o funcionamento do tratamento biológico da Mundotêxtil. A optimização pode começar na concepção dos produtos, pode incidir no processo de fabrico para além de poder ser efectuada no seio da estação de tratamento biológico. Foi efectuado um estudo do tratamento biológico por lamas activadas no Laboratório de Tecnologia Química Profª Doutora Lída de Vasconcelos, laboratório tecnológico do Instituto Superior de Engenharia do Porto (ISEP) que decorreu nos meses de Maio, Junho e Julho de 2010. O estudo laboratorial foi efectuado para três situações distintas: 1) tratamento do efluente bruto sem qualquer tipo de pré-tratamento (ensaios 1 a 3); 2) tratamento do efluente bruto submetido a pré-tratamento com coagulante Ambifloc BIO MD (ensaios 4 e 5) e 3) tratamento com adição de fungos ao tanque de arejamento (ensaio 6). Foram utilizadas duas instalações de tratamento alimentadas a partir do mesmo tanque de alimentação. Os dois sistemas eram idênticos, diferiram nos caudais de alimentação de efluente que foram alterados ao longo do estudo. O efluente a tratar foi fornecido pela empresa Mundotêxtil, sendo recolhido por diversas vezes ao longo dos ensaios. Este efluente foi retirado após o pré-tratamento da empresa, ou seja este efluente é o mesmo que alimenta o tratamento biológico da Mundotêxtil. Devido a este facto o efluente usado no estudo laboratorial teve uma variabilidade no período em que decorreu o estudo, nomeadamente em termos de concentração de CQO e cor. A relação entre a Carência Bioquímica (CBO5) e a CQO situouse entre 0,47 e 0,63 o que traduz que está dentro dos valores típicos para um efluente têxtil. Os melhores resultados globais de remoção de CQO foram obtidos no ensaio 5 e estiveram compreendidos entre 73,2% e 77,5% para o ensaio 5.1 e entre 62,9 e 73,2% para o ensaio 5.2. Neste ensaio foi utilizado o coagulante. Todos os valores de concentração de CQO obtidos nos efluentes dos decantadores para os ensaios 2, 5 e 6 são inferiores aos valores limite de descarga definidos nas normas de descarga no rio Ave e o Decreto-Lei 236/98. Os valores de concentração de Sólidos Suspensos Totais (SST), pH, fósforo, CBO5 e cor nos decantadores cumpriram os limites de descarga definidos nas normas de descarga no rio Ave e no Decreto-Lei nº 236/98 em todos os ensaios. Os parâmetros cinéticos obtidos para os ensaios com descorante são os que melhor se ajustam ao projecto de uma instalação de tratamento biológico por lamas activadas do efluente da Mundotêxtil. Os valores obtidos, após ajuste, são os seguintes: k=0,015 L/(mgSSV*d); Sn=12 mg/L; a=0,7982 kgO2/kgCBO5; b=0,0233 [kgO2/(kgSSV*d); y=0,2253 kgSSV/kgCBO5; kd=0,0036 kgSSV/(kgSSV*d. Com base nos parâmetros cinéticos obtiveram-se os seguintes resultados para o projecto de uma estação de tratamento biológico por lamas activadas: · Tempo de retenção hidráulica no reactor de 1,79 d, · Volume do reactor igual a 3643 m3 · Consumo de oxigénio no reactor de 604 kg/d · Razão de recirculação igual a 0,8 · Volume total do decantador secundário igual a 540 m3 · Diâmetro do decantador secundário igual a 15 m A quantidade de oxigénio necessário é baixa e o valor mais adequado deverá ser da ordem de 1200 kg/d. Também foi efectuada uma análise aos produtos químicos consumidos pela empresa na área das tinturarias com a finalidade de identificar as substâncias com uma maior influência potencial no funcionamento da Estação de Tratamento Biológico. O encolante CB, Cera Têxtil P Líquida, Perfemina P-12, Meropan DPE-P, Meropan BRE-P, Indimina STS e Benzym TEC são os produtos químicos que têm uma influência potencial mais significativa na qualidade dos efluentes. Devido ao facto das temperaturas do efluente alimentado ao tratamento biológico da Mundotêxtil oscilarem entre 35 ºC e 43ºC efectuou-se um estudo às necessidades de água quente das tinturarias e por outro lado à capacidade de aquecimento dos efluentes disponíveis. Actualmente a racionalização dos consumos de água é cada vez mais premente, por isso também é apresentado neste trabalho um estudo para a substituição das máquinas convencionais das tinturarias com uma relação de banho 1:10 por máquinas de banho curto (1:6,5). Verifica-se a redução de consumos de 40% de água, 52% de energia eléctrica, 35% de produtos químicos, 51% das necessidades de vapor e por consequência um aumento da produtividade. A empresa pode reduzir os consumos de água em cerca de 280.000 m3/ano. A utilização do pré-tratamento com o coagulante permitirá baixar a concentração da CQO e reduzir a cor à entrada do reactor tratamento biológico. Deste modo é possível manter um tratamento eficiente à saída do tratamento biológico nas situações de descarga de cores carregadas e carga orgânica elevada. Com este conjunto de soluções, quer sejam aplicadas na totalidade ou não, a empresa Mundotêxtil pode enfrentar o futuro com mais confiança podendo estar preparada para fazer face à escassez de água e custos cada vez maiores da energia. Por outro lado pode tratar os seus efluentes a custos menores. A substituição das máquinas de tingimento por máquinas com relação de banho mais baixa (banho curto) implica investimentos elevados mas estes investimentos são necessários não só por motivos ambientais mas também devido à grande competitividade dos mercados.
Resumo:
O presente relatório descreve o trabalho de estágio efectuado na empresa Curtumes Aveneda, Lda com o objectivo de optimizar recursos como a água e energia. Foi realizado um diagnóstico energético que permitiu concluir que o consumo de energia na empresa é de 300 tep/ano, pelo que a empresa não é obrigada a adoptar as medidas de Regulamento de Gestão do Consumo de Energia (RGCE). O mesmo diagnóstico aponta para a existência de ineficiências, nomeadamente na tinturaria. Assim, foi projectado um sistema de controlo para adição de água na tinturaria com o intuito de reduzir o consumo de energia e água, e também melhorar a qualidade dos processos de tinturaria, dado que a adição de água é feita manualmente sem controlo de quantidade. Após consulta de fornecedor, o investimento em equipamento para tal sistema é de 10.012,00€ Foi desenvolvido um processo de recurtume compacto no sentido de promover a redução do consumo de água e de energia. Tal processo, quando comparado com um processo normal da empresa, gera uma redução de energia eléctrica no valor de 6.157,05 €/ano, uma redução no consumo de energia térmica da ordem de 904,00 €/ano, e ainda uma redução do consumo de água na ordem de 962 m3/ano correspondente a uma redução de 2.998,76 €/ano no tratamento de efluentes. Outras medidas foram sugeridas, mas sem uma fundamentação técnica e científica suficiente pelo que carecem de um estudo pormenorizado, como a instalação de arrancadores progressivos nos motores dos fulões, a optimização do aquecimento do ar de secagem na estufa com eventual recurso a painéis solares, e a optimização do funcionamento da caldeira dado o seu baixo rendimento.