916 resultados para sequential injection
Resumo:
Superoxide radical (O2-) is a free radical that may be involved in various toxic processes. Cu-Zn superoxide dismutase catalyses the dismutation of the superoxide free radical and protects cells from oxidative damage, and it has been used clinically. The concentration of Ni2+ and Cu-Zn superoxide dismutase activity were measured in lungs of rats at time intervals of 5, 12, 19, 26, 33, and 40 days following an intratracheal injection of 127 nmol of NiCl2. Nickel chloride increased nickel content and resulted in a significant increase of Cu-Zn superoxide dismutase activity in lungs. This elevation of Cu-Zn superoxide dismutase activity was highest on the 12th day (approximately threefold) and is at levels comparable to controls rats on day 40 onwards. Since Cu-Zn superoxide dismutase activity was increased in lung throughout our experimental period without corresponding increases of Cu2+ and Zn2+, we speculate that the elevation of Cu-Zn superoxide dismutase activity might be due to an increased half-life of the enzyme, induced by nickel.
Resumo:
A comparative study is reported between C-18 bonded silica gel and powdered polyethylene (PE) as sorbent for Cd, Cu, and Pb determination using ammonium diethyldithiophosphate (ADTP) as the complexing agent in a flow injection system. The complexes were formed in 0.14 mol L-1 HNO3 and processed in a simple flow system comprising a peristaltic pump, a manual injector-commutator, and a sorbent-packed minicolumn. Ethanol was selected as the eluent and analytes in the eluate were determined by flame atomic absorption spectrometry. The optimum concentration of the complexing agent was 0.1% (m/v) ADTP for Cu and Pb determination using either C-18 or PE, and 0.25% (m/v) ADTP for Cd determination using PE. The sample loading flow rates were 5.0, 3.6, and 3.0 mL min(-1) for Cu, Pb, and Cd, respectively. The best elution flow rate was 6.5 mL min(-1). For a 60-sec preconcentration time, the sampling rate was 40 h(-1) and the enrichment factors of 33, 36, and 11 times (C-18) or 18, 22, and 23 times (PE) were obtained for Cu, Pb, and Cd, respectively. The limits of detection (LOD) were 1.6 mug L-1 Cu, 11 mug L-1 Pb, and 2.0 mug L-1 Cd using C-18 or 2.9 mug L-1 Cu, 19 mug L-1 Pb, and 1.0 mug L-1 Cd using PE, respectively. The relative standard deviations (n = 12) were typically <2%, <2%, and <6% for Cd, Cu, and Pb, respectively. The recoveries of Cd, Cu, and Pb added to wine samples varied from 96-99%, 97-102%, and 90-99%, respectively, using C-18 or PE. Accuracy was checked for Cd, Cu, and Pb determination in six wine samples digested by block digestor and open-vessel microwave-assisted digestion systems. The results revealed that C-18 was more efficient for Cu and Pb determination, while PE was the best sorbent for Cd.
Resumo:
A new method was developed for the simultaneous determination of As, Bi, Sb, and Se by flow injection hydride generation graphite furnace atomic absorption spectrometry. An alternative two-step sample treatment procedure was used. The sample was heated (80degreesC) for 10 min in 6 M HCl to reduce Se(VI) to Se(IV), followed by the addition of 1% (m/v) thiourea solution to reduce arsenic and antimony from the pentavalent to the trivalent states.With this procedure, all analytes were converted to their most favorable and sensitive oxidation states to generate the corresponding hydrides. The pre-treated sample solution was then processed in the flow system for in situ trapping and atomization in a graphite tube coated with iridium. The impermanent modifier remained stable up to 300 firings and new coating out significant were possible wit changes in the analytical performance.The accuracy was checked for As, Bi, Sb, and Se determination in water standard reference materials NIST 1640 and 1643d and the results were in agreement with the certified values at a 95% confidence level. Good recoveries (94-104%.) of spiked mineral waters and synthetic As(V), Sb(Ill), mixtures of As(Ill), Sb(V), Se(VI), and Se(IV) were also found. Calculated characteristic masses were 32 mug As, 79 mug Bi, 35 mug Sb, and 130 pg Se, and the corresponding limits of detection were 0.06, 0.16, 0.19, and 0.59 mug L-1, respectively. The repeatability for a typical solution containing 5 mug L-1 As, Bi, Sb, and Se was in the 1-3% range.
Resumo:
An automated system with a C-18 bonded silica gel packed minicolumn is proposed for spectrophotometric detection of arsenic using flow-injection hydride generation following sorbent extraction preconcentration. Complexes formed between arsenic(III) and ammonium diethyl dithiophosphate (ADDP) are retained on a C-18 sorbent. The eluted As-DDP complexes are merged with a 1.5% (w/v) NaBH4 and the resulting solution is thereafter injected into the hydride generator/gas-liquid separator. The arsine generated is carried out by a stream of N-2 and trapped in an alkaline iodine solution in which the analyte is determined by the arsenomolybdenum blue method. With preconcentration time of 120 s, calibration in the 5.00-50.0 mu g As l(-1) range and sampling rate of about 20 samples h(-1) are achieved, corresponding to 36 mg ADDP plus 36 mg ammonium heptamolybdate plus 7 mg hydrazine sulfate plus 0.7 mg stannous chloride and about 7 mi sample consumed per determination. The detection limit is 0.06 mu g l(-1) and the relative standard deviation (n = 12) for a typical 17.0 mu g As l(-1) sample is ca. 6%. The accuracy was checked for arsenic determination in plant materials from the NIST (1572 citrus leaves; 1573 tomato leaves) and the results were in agreement with the certified values at 95% confidence level. Good recoveries (94-104%) of spiked tap waters, sugars and synthetic mixtures of trivalent and pentavalent arsenic were also found. (C) 1999 Elsevier B.V. B.V. All rights reserved.
Resumo:
The aim of this work is to propose a simple and efficient mechanism to deal with the problem of executing sequential code in a pure dataflow machine. Our results is obtained with a simulator of Wolf [4] architecture. The implemented mechanism improved the architecture performance when executing sequential code and we expect that this improvement could be better if we use some heuristics to deal with some special groups of instructions such as branch operations. Further research will show us if this is true.
Resumo:
A study was undertaken to evaluate Saccharonzyces cerevisiae as a substrate for the biosorption of Cr(III) and Cr(VI) aiming to the selective determination of these species in aqueous solutions. The yeast cells were covalently immobilised on controlled pore glass (CPG), packed in a minicolumn and incorporated in an on-line flow injection system. The effect of chemical and physical variables affecting the biosorption process was tested in order to select the optimal analytical conditions for the Cr retention by S. cerevisiae. Cr(III) was retained by the immobilised cells and Cr(VI) were retained by CPG. The speciation was possible by selective and sequential elution of Cr(III) with 0.05 mol L-1 HCl and 2.0 mol L-1 HNO3 for Cr(VI). The influence of some concomitant ions up to 20 mg L-1 was also tested. Quantitative determinations of Cr were carried out by means of inductively coupled plasma optical emission spectrometry (ICP OES). Preconcentration factors of 12 were achieved for Cr(III) and 5 for Cr(VI) when 1.7 mL of sample were processed reaching detection limits of 0.45 for Cr(III) and 1.5 mu g L-1 for Cr(VI). The speciation of inorganic Cr in different kinds of natural waters was performed following the proposed method. Spiked water samples were also analysed and the recoveries were in all cases between 81 and 103%. (c) 2005 Elsevier B.V. All rights reserved.
Resumo:
Two Kalman-filter formulations are presented for the estimation of spacecraft sensor misalignments from inflight data. In the first the sensor misalignments are part of the filter state variable; in the second, which we call HYLIGN, the state vector contains only dynamical variables, but the sensitivities of the filter innovations to the misalignments are calculated within the Kalman filter. This procedure permits the misalignments to be estimated in batch mode as well as a much smaller dimension for the Kalman filter state vector. This results not only in a significantly smaller computational burden but also in a smaller sensitivity of the misalignment estimates to outliers in the data. Numerical simulations of the filter performance are presented.
Resumo:
Los efectos de la prostaglandina (PGF2α) vs CIDR y eCG (gonadotrofina coriónica equina) en la dinámica de la población folicular y su relación con las concentraciones plasmáticas de P4 fueron investigadas en ovejas cíclicas. Fueron utilizadas 14 hembras ovinas de la raza Bergamascia; el Grupo 1 (Gl) se sometió a dos aplicaciones de PGF2α, y, el Grupo 2 (G2) tratado con CIDR durante 14 días siendo que, en el momento de su retirada, se administraron 500 UI de eCG. La dinámica folicular ovárica fue monitoreada por medio de ecógrafo. Se monitorearon todos los folículos ≥ mm y se gráfico su posición diariamente, observándose el desarrollo individual folicular. Desde el día anterior a la aplicación de la segunda dosis de PGF2α, (Gl) y desde la administración de eCG (G2) hasta el décimo día del ciclo estral se colectaron muestras de sangre para el análisis de P4. Hubo diferencia significativa (P<0,001) en las concentraciones plasmáticas de P4 entre los tratamientos. La sincronización del estro y ovulación utilizando CIDR + 500 UI de eCG, incrementó la cantidad de folículos reclutados, además de aumentar el diámetro máximo y la tasa de crecimiento de los folículos grandes en la primera onda folicular. En consideración a los resultados se puede concluir que la sincronización del estro y de la ovulación en hembras ovinas, utilizando el CIDR y 500 UI de eCG, incrementa la cantidad de folículos reclutados, además de aumentar el diámetro máximo y la tasa de crecimiento de los folículos grandes. La asociación CIDR+500 UI de eCG provoca aumentos significativos en las concentraciones plasmáticas de progesterona (P4) al inicio de la fase luteal en hembras ovinas.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The microinjection of carbachol into the medial preoptic area (MPO) of the rat induced natriuresis, kaliuresis and anti-diuresis in a dose-related manner. Atropine blocked all responses to carbachol. Hexamethonium impaired the dose-response effect of carbachol on kaliuresis, but had no effect on natriuresis and enhanced the antidiuretic effect of carbachol. Nicotine alone had no effects, but pre-treatment with nicotine enhanced the responses to carbachol. These data show that activity of the muscarinic receptors of the MPO increases renal electrolyte and reduces water excretion. They also suggest that nicotinic receptors have an inhibitory effect on water excretion. Nicotine could act through mechanisms unrelated to nicotinic receptors to enhance the effect of the carbachol. © 1989.
Resumo:
The development of a fever in response to intravenous (IV, 1.5 μg/kg body mass) and intracerebroventricular (ICV, 1.5 μg/animal) injections of Escherichia coli lipopolysaccharide (LPS) was studied in control, thyroidectomised and protein-calorie malnourished rabbits (New Zealand Whites, n = 55). ICV injection of LPS is control rabbits produced a fever response, the characteristics of which differed from those obtained after IV pyrogen injection. Thyroid deficiency caused an attenuated fever response, irrespective of whether LPS had been administered by IV or ICV injection. Protein-calorie malnourished rabbits showed a smaller fever response after IV or ICV pyrogen injections. Malnourished rabbits, refed over a period of 15 days, showed a typical biphasic fever response, but with lower magnitude than controls. The results of these experiments suggest that ICV injection of LPS is not an appropriate model for the study of fever mechanisms in disease states, and that the attenuated fever response observed in protein-calorie malnourished rabbits may be related, at least in part, to a decreased ability to produce the endogenous pyrogen interleukin-1.