990 resultados para pressure pain thresholds


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Patient blood pressure is an important vital signal to the physicians take a decision and to better understand the patient condition. In Intensive Care Units is possible monitoring the blood pressure due the fact of the patient being in continuous monitoring through bedside monitors and the use of sensors. The intensivist only have access to vital signs values when they look to the monitor or consult the values hourly collected. Most important is the sequence of the values collected, i.e., a set of highest or lowest values can signify a critical event and bring future complications to a patient as is Hypotension or Hypertension. This complications can leverage a set of dangerous diseases and side-effects. The main goal of this work is to predict the probability of a patient has a blood pressure critical event in the next hours by combining a set of patient data collected in real-time and using Data Mining classification techniques. As output the models indicate the probability (%) of a patient has a Blood Pressure Critical Event in the next hour. The achieved results showed to be very promising, presenting sensitivity around of 95%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report the case of a 57-year-old male patient with severe low back pain during streptokinase infusion administered to treat typical chest pain and elevation of the ST segment in the inferior wall. We reviewed the literature, emphasizing the differential diagnosis, the pathophysiology, and management of the event.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A 59-year-old female patient with mitral valve prolapse and a previous history of lumbosacral spondyloarthrosis and lumbar disk hernia had an episode of infective endocarditis due to Streptococcus viridans, which evolved with peripheral embolism to the left kidney, spleen, and left iliac artery, and intraventricular cerebral hemorrhage. Her clinical manifestations were low back pain and hematuria, which were initially attributed to an osteoarticular condition. Infective endocarditis is a severe polymorphic disease with multiple clinical manifestations and it should always be included in the differential diagnosis by clinicians.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE - To assess hypertension control rates in a specialized university-affiliated medical department, the influence of sex, diabetes, and obesity on that control, and the strategies for the treatment of hypertension. METHODS - We carried out a cross-sectional study with 1,210 patients followed up for at least 6 months. Information was gathered from medical and nursing records and comprised the following data: sex, age, weight, height, abdominal and hip circumferences, blood pressure, and class and number of the antihypertensive drugs prescribed. To assess obesity, we used body mass index and waist/hip ratio. Blood pressure was considered under control when its levels were below 140/90 mmHg. RESULTS - The study consisted of 73% females and 27% males. Most females (31.7%) were 50 to 59 years of age, and most males (28.3%) were 60 to 69 years. The blood pressure control rate found was 20.9% for the 1,210 patients and 23.4% for the hypertensive diabetic patients (n=290). Despite the low control rates found, 70% of the patients used 1 or 2 antihypertensive medications. A high prevalence of obesity (38%) was observed, and females had a greater abdominal obesity index than males did (90% vs 82%, p<0.05). Patients with a greater body mass index had less control of blood pressure. CONCLUSION - The percentage of hypertensive patients with controlled blood pressure levels was low and was associated with a high prevalence of obesity. These data indicate the need for reviewing the strategies of global treatment for hypertension.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE - To study cardiovascular alterations in young patients with no apparent organic disease who underwent electroconvulsive therapy. METHODS - The study comprised 47 healthy patients (22 males and 25 females) with a mean age of 30.3 years, who underwent electroconvulsive therapy. Ambulatory blood pressure monitoring and continuous electrocardiographic monitoring (Holter monitor) were performed during 24 hours. Blood pressure and heart rate were assessed 4 hours prior to electric shock administration, during electric shock administration, and 3 hours after electric shock administration. Arrhythmias and alterations in the ST segment in 24 hours were recorded. RESULTS - On electroconvulsive therapy, a significant increase in blood pressure and heart rate was observed and the measurements returned to basal values after 25 minutes. Three females had tracings with depression of the ST segment suggesting myocardial ischemia prior to and after electroconvulsive therapy. Coronary angiography was normal. No severe cardiac arrhythmias were diagnosed. CONCLUSION - 1) Electroconvulsive therapy is a safe therapeutic modality in psychiatry; 2) it causes a significant increase in blood pressure and heart rate; 3) it may be associated with myocardial ischemia in the absence of coronary obstructive disease; 4) electroconvulsive therapy was not associated with the occurrence of severe cardiac arrhythmias.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

It is estimated that 5 to 8 million individuals with chest pain or other symptoms suggestive of myocardial ischemia are seen each year in emergency departments (ED) in the United States 1,2, which corresponds to 5 to 10% of all visits 3,4. Most of these patients are hospitalized for evaluation of possible acute coronary syndrome (ACS). This generates an estimated cost of 3 - 6 thousand dollars per patient 5,6. From this evaluation process, about 1.2 million patients receive the diagnosis of acute myocardial infarction (AMI), and just about the same number have unstable angina. Therefore, about one half to two thirds of these patients with chest pain do not have a cardiac cause for their symptoms 2,3. Thus, the emergency physician is faced with the difficult challenge of identifying those with ACS - a life-threatening disease - to treat them properly, and to discharge the others to suitable outpatient investigation and management.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To determine technical procedures and criteria used by Brazilian physicians for measuring blood pressure and diagnosing hypertension. METHODS: A questionnaire with 5 questions about practices and behaviors regarding blood pressure measurement and the diagnosis of hypertension was sent to 25,606 physicians in all Brazilian regions through a mailing list. The responses were compared with the recommendations of a specific consensus and descriptive analysis. RESULTS: Of the 3,621 (14.1%) responses obtained, 57% were from the southeastern region of Brazil. The following items were reported: use of an aneroid device by 67.8%; use of a mercury column device by 14.6%; 11.9% of the participants never calibrated the devices; 35.7% calibrated the devices at intervals < 1 year; 85.8% measured blood pressure in 100% of the medical visits; 86.9% measured blood pressure more than once and on more than one occasion. For hypertension diagnosis, 55.7% considered the patient's age, and only 1/3 relied on consensus statements. CONCLUSION: Despite the adequate frequency of both practices, it was far from that expected, and some contradictions between the diagnostic criterion for hypertension and the number of blood pressure measurements were found. The results suggest that, to include the great majority of the medical professionals, disclosure of consensus statements and techniques for blood pressure measurement should go beyond the boundaries of medical events and specialized journals.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To assess the Dixtal DX2710 automated oscillometric device used for blood pressure measurement according to the protocols of the BHS and the AAMI. METHODS: Three blood pressure measurements were taken in 94 patients (53 females 15 to 80 years). The measurements were taken randomly by 2 observers trained to measure blood pressure with a mercury column device connected with an automated device. The device was classified according to the protocols of the BHS and AAMI. RESULT: The mean of blood pressure levels obtained by the observers was 148±38/93±25 mmHg and that obtained with the device was 148±37/89±26 mmHg. Considering the differences between the measurements obtained by the observer and those obtained with the automated device according to the criteria of the BHS, the following classification was adopted: "A" for systolic pressure (69% of the differences < 5; 90% < 10; and 97% < 15 mmHg); and "B" for diastolic pressure (63% of the differences < 5; 83% < 10; and 93% < 15 mmHg). The mean and standard deviation of the differences were 0±6.27 mmHg for systolic pressure and 3.82±6.21 mmHg for diastolic pressure. CONCLUSION: The Dixtal DX2710 device was approved according to the international recommendations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To assess blood pressure measurement by health professionals of a public hospital in São Paulo State. METHODS: Semi-structured interviews and direct observation were performed with a verification list according to the criteria reported by Perloff et al. One hundred and five health professionals took part in the study. After measuring blood pressure, the level of concordance between the way the procedure was performed and the recommended one was assessed. RESULTS: Nurses and nurse's aides abided by 40% of the recommended procedures for adequate blood pressure measurement. The other categories of health professionals (nursing and medicine teachers, physicians, residents, and nursing students) abided by approximately 70%. CONCLUSION: Permanent educational activities aiming at standardizing blood pressure measurement should be implemented among the different categories of health professionals.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE:To verify the influence of moderate- or high-pressure balloon inflation during primary coronary stent implantation for acute myocardial infarction. METHODS: After successful coronary stent implantation, 82 patients were divided into 2 groups according to the last balloon inflation pressure: group 1 (³12 to <16 atm) and group 2 (³16 to 20 atm), each with 41 cases. All patients underwent late coronary angiography. RESULTS: In group 1, the mean stent deployment pressure was 13.58±0.92 atm, and in the group 2 it was 18.15±1.66 atm. Stents implanted with moderate pressures (³12 to <16 atm) had a significantly smaller postprocedural minimal lumen diameter, compared to with those with higher pressure, with lesser acute gain (2.7± 0.4 mm vs 2.9±04 mm; p=0.004), but the late lumen loss (0,9±0,8 mm vs 0,9±0,6 mm) and the restenosis (22% vs. 17.1%) and target-vessel revascularization rates (9.8% vs 7.3%) were similar between the groups. CONCLUSION: During AMI stenting, the use of high pressures (³16 atm) did not cause a measurable improvement in late outcome, either in the late loss, its index, and the net gain, or in clinical and angiographic restenosis rates.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To investigate the role of hemodynamic changes occurring during acute MI in subsequent fibrosis deposition within non-MI. METHODS: By using the rat model of MI, 3 groups of 7 rats each [sham, SMI (MI <30%), and LMI (MI >30%)] were compared. Systemic and left ventricular (LV) hemodynamics were recorded 10 minutes before and after coronary artery ligature. Collagen volume fraction (CVF) was calculated in picrosirius red-stained heart tissue sections 4 weeks later. RESULTS: Before surgery, all hemodynamic variables were comparable among groups. After surgery, LV end-diastolic pressure increased and coronary driving pressure decreased significantly in the LMI compared with the sham group. LV dP/dt max and dP/dt min of both the SMI and LMI groups were statistically different from those of the sham group. CVF within non-MI interventricular septum and right ventricle did not differ between each MI group and the sham group. Otherwise, subendocardial (SE) CVF was statistically greater in the LMI group. SE CVF correlated negatively with post-MI systemic blood pressure and coronary driving pressure, and positively with post-MI LV dP/dt min. Stepwise regression analysis identified post-MI coronary driving pressure as an independent predictor of SE CVF. CONCLUSION: LV remodeling in rats with MI is characterized by predominant SE collagen deposition in non-MI and results from a reduction in myocardial perfusion pressure occurring early on in the setting of MI.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To assess safety, feasibility, and the results of early exercise testing in patients with chest pain admitted to the emergency room of the chest pain unit, in whom acute myocardial infarction and high-risk unstable angina had been ruled out. METHODS: A study including 1060 consecutive patients with chest pain admitted to the emergency room of the chest pain unit was carried out. Of them, 677 (64%) patients were eligible for exercise testing, but only 268 (40%) underwent the test. RESULTS: The mean age of the patients studied was 51.7±12.1 years, and 188 (70%) were males. Twenty-eight (10%) patients had a previous history of coronary artery disease, 244 (91%) had a normal or unspecific electrocardiogram, and 150 (56%) underwent exercise testing within a 12-hour interval. The results of the exercise test in the latter group were as follows: 34 (13%) were positive, 191 (71%) were negative, and 43 (16%) were inconclusive. In the group of patients with a positive exercise test, 21 (62%) underwent coronary angiography, 11 underwent angioplasty, and 2 underwent myocardial revascularization. In a univariate analysis, type A/B chest pain (definitely/probably anginal) (p<0.0001), previous coronary artery disease (p<0.0001), and route 2 (patients at higher risk) correlated with a positive or inconclusive test (p<0.0001). CONCLUSION: In patients with chest pain and in whom acute myocardial infarction and high-risk unstable angina had been ruled out, the exercise test proved to be feasible, safe, and well tolerated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To assess the relation between blood pressure control and the following: the Morisky-Green test, the patient's consciousness regarding high blood pressure, the patient's attitude in face of medicine intake, the patient's attendance at medical consultations, and the subjective physician's judgment. METHODS: We studied 130 hypertensive patients with the following characteristics: 73% females, 60±11 years, 58% married, 70% white, 45% retired, 45% with incomplete elementary schooling, 64% had a familial income of 1 to 3 minimum wages, body mass index of 30±7 kg/m², consciousness regarding the disease for a mean period of 11±9.5 years, and mean treatment duration of 8 ±7 years. RESULTS: Only 35% of the hypertensive individuals had blood pressure under control and a longer duration of treatment (10±7 vs 7±6.5 years; P<0.05). The retiree predominated. The result of the Morisky-Green test did not relate to blood pressure control. In evaluating the attitude in face of medicine intake, the controlled patients achieved significantly higher scores than did the noncontrolled patients (8±1.9 vs 7 ±2, P<0.05). The hypertensive patients had higher levels of consciousness regarding their disease and its treatment, and most (70%) patients attended 3 or 4 medical consultations, which did not influence blood pressure control. The physicians attributed significantly higher scores regarding adherence to treatment to controlled patients (6±0.8 vs 5±1.2; P<0.05). CONCLUSION: Consciousness regarding the disease, the Morisky-Green test, and attendance to medical consultations did not influence blood pressure control.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abdominal Aortic Aneurysms (AAA) haemorhaging is a life-threatening disease. An aneurysm is a permanent swelling of an artery due to a weakness in its wall. Current surgical repair involves opening the chest or abdomen, gaining temporary vascular control of the aorta and suturing a prosthetic graft to the healthy aorta within the aneurysm itself The outcome of this surgical approach is not perfect, and the quality of life after this repair is impaired by postoperative pain, sexual dysfunction, and a lengthy hospital stay resulting in high health costs. All these negative effects are related to the large incision and extensive tissue dissection. Endovascular grafting is an alternative to the standard surgical method. This treatment is a less invasive method of treating aortic aneurysms. It involves a surgical exposure of the common femoral arteries where the stent graft can be inserted through by an over-the-wire technique. All manipulations are controlled from a remote place by the use of a catheter and this technique avoids the need to directly expose the diseased artery through a large incision or an extensive dissection. The proposed design method outlined in this project is to develop the endovascular approach. The main aim is to design an unitary bifurcated stent graft (1 e- bifurcated graft as a single component) to treat these Abdominal Aortic Aneurysms. This includes the delivery system and deployment mechanism necessary to first accurately position the stent graft across the aneurysm sac and also across the iliac bifurcation, and secondly fix the stent graft in position by using expandable metal stents. Thus, excluding the aneurysm from the circulation and therefore preventing rupture. Miniaturisation is a critical aspect of this design, as the smaller the crimped stent graft the easier to guide through the vascular system to the desired location. Biocompatibility is an important aspect. The preferred materials for this prosthesis are to use Shape Memory Alloys for the stent and a multifilament fabric for the graft. A taper design is applied for the geometry as this gives a favourable flow characteristic and reduced wave reflections. Adequate testing of the stent graft to prove its durability and the ease of the method of deployment is a prerequisite. A bench test facility has being designed and build to replicate the cardiovascular system and the disease in question aortic aneurysms at the iliac bifurcation. The testing here shows the feasibility of the proposed delivery system and the durability of the stent graft across the aneurysm sac. Finally, these endovascular treatments offer the economic advantage of short hospital stays or even treatment as an outpatient, as well as elimination of the need for postoperative intensive care The risk of developing an aneurysm increases with age, that is one of the mam reasons to look for less invasive ways of treating aneurysms. Consequently, there is enormous pressure to develop and use these devices rapidly.