872 resultados para mechanical device


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Over the past decade, various implantable devices have been developed to treat diseases that were previously difficult to manage such diabetes, chronic pain, and neurodegenerative disorders. However, translation of these novel technologies into clinical practice is often difficult because fibrotic encapsulation and/or rejection impairs device function after body implantation. Ideally, cells of the host tissue should perceive the surface of the implant being similar to the normal extracellular matrix. Here, we developed an innovative approach to provide implant surfaces with adhesive protein micropatterns. The patterns were designed to promote adhesion of fibroblasts and macrophages by simultaneously suppressing fibrogenic activation of both cell types. In a rat model, subcutaneously implanted silicone pads provided with the novel micropatterns caused 6-fold lower formation of inflammatory giant cells compared with clinical grade, uncoated, or collagen-coated silicone implants. We further show that micropatterning of implants resulted in 2-3-fold reduced numbers of pro-fibrotic myofibroblast by inhibiting their mechanical activation. Our novel approach allows controlled cell attachment to implant surfaces, representing a critical advance for enhanced biointegration of implantable medical devices.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Parastomal hernia (PSH) is the most frequent long-term stoma complication with serious negative effects on quality of life. Surgical revision is often required and has a substantial morbidity and recurrence rate. The development of PSH requires revisional surgery with a substantial perioperative morbidity and high failure rate in the long-term follow-up. Prophylactic parastomal mesh insertion during stoma creation has the potential to reduce the rate of PSH, but carries the risk of early and late mesh-related complications such as infection, fibrosis, mesh shrinkage, and/or bowel erosion. We developed a new stomaplasty ring (KORING), which is easy to implant, avoids potential mesh-related complications, and has a high potential of long-term prevention of PSH. Here we describe the technique and the first use.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

CORBA (Common Object Request Broker Architecture) on laajalle levinnyt ja teollisuudessa yleisesti käytetty hajautetun tietojenkäsittelyn arkkitehtuuri. CORBA skaalautuu eri kokoisiin tarpeisiin ja sitä voidaan hyödynntää myös sulautetuissa langattomissa laitteissa. Oleellista sulautetussa ympäristössä on rakentaa rajapinnat kevytrakenteisiksi, pysyviksi ja helposti laajennettaviksi ilman että yhteensopivuus aikaisempiin rajapintoihin olisi vaarassa. Langattomissa laitteissa resurssit, kuten muistin määrä ja prosessointiteho, ovat hyvin rajalliset, joten rajapinta tulee suunnitella ja toteuttaa optimaalisesti. Palveluiden tulee ottaa huomioon myös langattomuuden rajoitukset, kuten hitaat tiedonsiirtonopeudet ja tiedonsiirron yhteydettömän luonteen. Työssä suunniteltiin ja toteutettiin CORBA-rajapinta GSM-päätelaitteeseen, jonka on todettu täyttävän sille asetetut tavoitteet. Rajapinta tarjoaa kaikki yleisimmät GSM-terminaalin ominaisuudet ja on laajennettavissa tulevia tuotteita ja verkkotekniikoita varten. Laajennettavuutta saavutetaan esimerkiksi kuvaamalla terminaalin ominaisuudet yleisellä kuvauskielellä, kuten XML:lla (Extensible Markup Language).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The University of Barcelona is developing a pilot-scale hot wire chemical vapor deposition (HW-CVD) set up for the deposition of nano-crystalline silicon (nc-Si:H) on 10 cm × 10 cm glass substrate at high deposition rate. The system manages 12 thin wires of 0.15-0.2 mm diameter in a very dense configuration. This permits depositing very uniform films, with inhomogeneities lower than 2.5%, at high deposition rate (1.5-3 nm/s), and maintaining the substrate temperature relatively low (250 °C). The wire configuration design, based on radicals' diffusion simulation, is exposed and the predicted homogeneity is validated with optical transmission scanning measurements of the deposited samples. Different deposition series were carried out by varying the substrate temperature, the silane to hydrogen dilution and the deposition pressure. By means of Fourier transform infrared spectroscopy (FTIR), the evolution in time of the nc-Si:H vibrational modes was monitored. Particular importance has been given to the study of the material stability against post-deposition oxidation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tämän tutkimuksen ensisijaisena tavoitteena oli määrittää Schauman Wood Oy:n ostoprosessin suorituskyvyn nykytila yrityksen Suomen yksiköissä. Nykytila-arviointi suoritettiin uusien ja käytössä olevien mittaustulosten avulla. Tutkimuksessa verrattiin kymmenen tuotantolaitoksen ostoprosesseja keskenään. Keskeinen tutkimusongelma oli ostoprosessin suorituseroja aikaansaavien tekijöiden selvittäminen eri yksiköissä. Tutkimuksen tavoitteena oli saavuttaa yhtenäisemmät toimintatavat yrityksessä sekä laajentaa konsernin osto-organisaation hyödyntämistä hankintatoimessa. Tavoitteena oli ostoprosessin virtaviivaistaminen ja tehokkaamman seurantajärjestelmän kehittäminen. Ostotoimintojen suorituskyvyn jatkuva parantaminen perustuu osittain uusien mittareiden avulla saatavaan informaatioon ja täsmällisempään seurantaan. Sisäistä benchmarkingia käytettiin työkaluna suorituskyky-eroavaisuuksien määrittelyssä. Tietoa erilaisista toimintatavoista kerättiin haastattelemalla yrityksen ostajia ja tehdaspalvelupäälliköitä eri tehdaspaikkakunnilla. Sisäisen benchmarkingin avulla määriteltiin toimintatapa eroavaisuudet sekä kehitettiin seurantakortti, jossa jokaista yksikköä verrataan parhaaseen ja eniten kehittyneeseen yksikköön. Työn tuloksina muodostui ehdotuksia ostotoiminnon uusiksi mittareiksi. Uudet mittarit ovat tehokkuusmittareita, jotka kuvaavat resurssien käytön tehokkuutta sekä auttavat seuraamaan ostoprosessin tilaa entistä paremmin. Uusien mittareiden tavoitteena on myös vähentää mittareiden manipulaatiomahdollisuutta. Työn ulkopuolelle rajattiin informaatioteknologiajärjestelmien tietotekninen osuus. Eräs yrityksen tuotantolaitoksista rajattiin myös työn ulkopuolelle, koska sen ostoprosessit ovat huomattavasti kehittymättömämpiä kuin Schauman Woodin muiden tehtaiden ostoprosessit. Kyseisen yksikön kehittämisen tulee lähteä aivan ruohonjuuritasolta. Tutkimuksen teoriaosuus on kerätty alan ammattikirjallisuudesta ja tutkimuksen aihetta käsittelevistä uudehkoista tieteellisistä alan artikkeleista. Teorian tarkoituksena on tukea empiiristä osuutta sekä antaa lukijalle uusia näkemyksiä ostotoiminnan monista mahdollisuuksista. Tutkimuksen tuloksia ovat nykytila-analyysi, ehdotukset uusista ostotoiminnan mittareista sekä ehdotus MRO-tuotteiden ulkoistamiskokeilusta. Yrityksen ostotoiminnan tulisi kehittyä operatiivisesta tasosta kohti strategisempaa oston tasoa. Johdon sitoutuminen hankintatoimen kehityshankkeisiin on erityisen tärkeää, lisäksi hankintatoimi tulisi nähdä strategisempana osa-alueena yrityksessä. Hankintatoimen kehittämisen avulla yrityksen kustannustehokkuutta voidaan lisätä merkittävästi.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To improve our understanding of the limiting factors during repeated sprinting, we manipulated hypoxia severity during an initial set and examined the effects on performance and associated neuro-mechanical alterations during a subsequent set performed in normoxia. On separate days, 13 active males performed eight 5-s sprints (recovery = 25 s) on an instrumented treadmill in either normoxia near sea-level (SL; FiO2 = 20.9%), moderate (MH; FiO2 = 16.8%) or severe normobaric hypoxia (SH; FiO2 = 13.3%) followed, 6 min later, by four 5-s sprints (recovery = 25 s) in normoxia. Throughout the first set, along with distance covered [larger sprint decrement score in SH (-8.2%) compared to SL (-5.3%) and MH (-7.2%); P < 0.05], changes in contact time, step frequency and root mean square activity (surface electromyography) of the quadriceps (Rectus femoris muscle) in SH exceeded those in SL and MH (P < 0.05). During first sprint of the subsequent normoxic set, the distance covered (99.6, 96.4, and 98.3% of sprint 1 in SL, MH, and SH, respectively), the main kinetic (mean vertical, horizontal, and resultant forces) and kinematic (contact time and step frequency) variables as well as surface electromyogram of quadriceps and plantar flexor muscles were fully recovered, with no significant difference between conditions. Despite differing hypoxic severity levels during sprints 1-8, performance and neuro-mechanical patterns did not differ during the four sprints of the second set performed in normoxia. In summary, under the circumstances of this study (participant background, exercise-to-rest ratio, hypoxia exposure), sprint mechanical performance and neural alterations were largely influenced by the hypoxia severity in an initial set of repeated sprints. However, hypoxia had no residual effect during a subsequent set performed in normoxia. Hence, the recovery of performance and associated neuro-mechanical alterations was complete after resting for 6 min near sea level, with a similar fatigue pattern across conditions during subsequent repeated sprints in normoxia.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We described for the first time the amino acid substitutions conferring rifampicin resistance in eight Propionibacterium acnes strains isolated from patients with biofilm or device-related infections. We identified different mutations in cluster I and one mutation, never reported, in cluster II of the rpoB gene (I480V) associated with the most frequent one in cluster I (S442L). Half of the patients previously received treatment with rifampicin.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We address the challenges of treating polarization and covalent interactions in docking by developing a hybrid quantum mechanical/molecular mechanical (QM/MM) scoring function based on the semiempirical self-consistent charge density functional tight-binding (SCC-DFTB) method and the CHARMM force field. To benchmark this scoring function within the EADock DSS docking algorithm, we created a publicly available dataset of high-quality X-ray structures of zinc metalloproteins ( http://www.molecular-modelling.ch/resources.php ). For zinc-bound ligands (226 complexes), the QM/MM scoring yielded a substantially improved success rate compared to the classical scoring function (77.0% vs 61.5%), while, for allosteric ligands (55 complexes), the success rate remained constant (49.1%). The QM/MM scoring significantly improved the detection of correct zinc-binding geometries and improved the docking success rate by more than 20% for several important drug targets. The performance of both the classical and the QM/MM scoring functions compare favorably to the performance of AutoDock4, AutoDock4Zn, and AutoDock Vina.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: Transapical transcatheter valve procedures are performed through a left minithoracotomy and require apical sutures to seal the apical access site. The use of large-calibre devices compromises any attempt to fully perform the procedure with a thoracoscopic approach or percutaneously. We report our preliminary experience in animals with a new sutureless self-expandable apical occluder, engineered to perform transapical access site closure in a minimally invasive setting with large-size introducer sheaths. METHODS: The apical occluder with extendable waist was implanted in six young pigs during an acute animal study. Under general anaesthesia, animals (mean weight: 62 ± 8 kg) received full heparinization (heparin: 100 UI/kg; activated clotting time above 250 s). Through a median sternotomy, a 21-Fr Certitude? introducer sheath (outer diameter: 25 Fr) was placed over the wire into the cardiac apex. The delivery catheter carrying the constrained apical plug was inserted into the sheath and deployed under fluoroscopic control, whereas the Certitude? was retrieved. After protamine infusion, we observed and recorded the 1-h bleeding with standard haemodynamic parameters. Animals were sacrificed, and hearts analysed. RESULTS: Six apical closure devices were successfully introduced and deployed in six pig hearts through large-size apical sheaths at first attempt. In all animals, the plugs guaranteed immediate apical sealing and traces of blood were collected in the pericardium during the 1-h observational period (mean of 16 ± 3.4 ml of blood loss per animal). Haemodynamic parameters remained stable during the entire study period and no plug dislodgement was detected with normal systemic blood pressure (mean arterial mean blood pressure: 65 ± 7 mmHg). Post-mortem analysis confirmed the full deployment and good fixation of all plugs, without macroscopic damages to the surrounding myocardium. CONCLUSIONS: This sutureless self-expandable apical occluder is a simple device capable of sealing large-size apical access sites (20-35 Fr) in an acute animal study. This approach is a step further towards less invasive transapical valve procedures in the clinical setting, and further animal tests will be performed to confirm the long-term efficacy and safety of this device.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIM: According to the French GRECCAR III randomized trial, full mechanical bowel preparation (MBP) for rectal surgery decreases the rate of postoperative morbidity, in particular postoperative infectious complications, but MBP is not well tolerated by the patient. The aim of the present study was to determine whether a preoperative rectal enema (RE) might be an alternative to MBP. METHODS: An analysis was performed of 96 matched cohort patients undergoing rectal resection with primary anastomosis and protective ileostomy at two different university teaching hospitals, whose rectal cancer management was comparable except for the choice of preoperative bowel preparation (MBP or RE). Prospective databases were retrospectively analysed. RESULTS: Patients were well matched for age, gender, body mass index and Charlson index. The surgical approach and cancer characteristics (level above anal verge, stage and use of neoadjuvant therapy) were comparable between the two groups. Anastomotic leakage occurred in 10% of patients having MBP and in 8% having RE (P = 1.00). Pelvic abscess formation (6% vs 2%, P = 0.63) and wound infection (8% vs 15%, P = 0.55) were also comparable. Extra-abdominal infection (13% vs 13%, P = 1.00) and non-infectious abdominal complications such as ileus and bleeding (27% and 31%, P = 0.83) were not significantly different. Overall morbidity was comparable in the two groups (50% vs 54%, P = 0.83). CONCLUSION: A simple RE before rectal surgery seems not to be associated with more postoperative infectious complications nor a higher overall morbidity than MBP.