764 resultados para implante coclear
Resumo:
The purpose of this study was to evaluate the macroscopy and microstructure of a double setting alpha-tricalcium phosphate bone cement sphere provided with interconnection channels (alpha-TCP-i), as well as the integration of the implant with the rabbits' orbital tissue, through macroscopic analysis and histopathology. The external and internal surfaces of the alpha-TCP-i were evaluated macroscopically and by electron microscopy. Twelve New Zealand rabbits received 12mm implants of alpha-TCP-i following enucleation of the left eye. The clinical assessment was undertaken daily during the first 15 days, followed by fortnightly assessment until the end of the study period. For the morphological analysis, exenteration was performed in 3 animals per experimental period (15, 45, 90 and 180 days). The external and internal surfaces of the implant appeared solid, smooth and compact, with six channels which interconnected centrally. The micro-architecture was characterized by the formation of columns of hexagonal crystals. No signs of infection, exposure, dehiscence of sutures or extrusion of the implant were noted in any of the animals during the entire period of the study. The morphological evaluation demonstrated the presence of a thin capsule around the implant, from whence appeared fibro-vascular projections, which penetrated it through the interconnecting channels. In the first days after the insertion of the implant, an intense inflammatory reaction was noted. At 180 days, however, there were no signs of inflammation. The alpha-tricalcium phosphate cement implant was well tolerated in this rabbit model and appeared to be relatively inert with some fibrovascular ingrowth through the large channels.
Resumo:
In view of the low loading values commonly employed in dentistry, a load-application device (LAD) was developed as option to the universal testing machine (UTM), using strain gauge analysis. The aim of this study was to develop a load-application device (LAD) and compare the LAD with the UTM apparatus under axial and non-axial loads. An external hexagonal implant was inserted into a polyurethane block and one EsthetiCone abutment was connected to the implant. A plastic prosthetic cylinder was screwed onto the abutment and a conical pattern crown was fabricated using acrylic resin. An impression was made and ten identical standard acrylic resin patterns were obtained from the crown impression, which were cast in nickel-chromium alloy (n=10). Four strain gauges were bonded diametrically around the implant. The specimens were subjected to central (C) and lateral (L) axial loads of 30 kgf, on both devices: G1: LAD/C; G2: LAD/L; G3: UTM/C; G4: UTM/L. The data (με) were statistically analyzed by repeated measures ANOVA and Tukey's test (p<0.05). No statistically significant difference was found between the UTM and LAD devices, regardless of the type of load. It was concluded that the LAD is a reliable alternative, which induces microstrains to implants similar to those obtained with the UTM.
Resumo:
Pós-graduação em Ciência Odontólogica - FOA
Resumo:
Neste trabalho investigou-se a modificação de superfície do titânio pela irradiação com feixe de Laser Nd:YAG. Os parâmetros do laser como a potência, o comprimento de onda, a frequência, a velocidade de varredura e a área de exposição foram mantidos constantes, exceto o espaçamento da matriz, o qual foi de 0,01 e 0,02 mm. A caracterização da superfície foi realizada por Microscopia Eletrônica de Varredura (MEV) e Difração de Raios X (DRX), sendo que os espectros foram refinados pelo método Rietveld. Pela análise de MEV, observou-se uma mudança na topografia, obtendo uma superfície rugosa produzida pelo fenômeno de ablação. As análises por Rietveld dos espectros de difração de raios X detectaram TiN, Ti2N, TiO2 (anatásio e rutilo), sendo que a amostra com espaçamento 0,01 mm apresentou uma maior quantidade de óxidos e nitretos. Isso pode ser devido à sobreposição do feixe, induzindo à formação de uma superfície com maior estabilidade termodinâmica. Os óxidos e nitretos obtidos são de grande importância, pois são responsáveis por produzir uma maior interação entre o osso-implante.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The purpose of this study was to analyze the bone repair around commercially pure titanium implants with rough and porous surface, fabricated using powder metallurgy technique, after their insertion in tibiae of rabbits. Seven male rabbits were used. Each animal received 3 porous-surface implants in the left tibia and 3 rough-surface implants in the right tibia. The rabbits were sacrificed 4 weeks after surgery and fragments of the tibiae containing the implants were submitted to histological and histomorphometric analyses to evaluate new bone formation at the implant-bone interface. Means (%) of bone neoformation obtained in the histomorphometric analysis were compared by Student's t-test for paired samples at 5% significance level.. The results of the histological analysis showed that osseointegration occurred for both types of implants with similar quality of bone tissue. The histomorphometric analysis revealed means of new bone formation at implant-bone interface of 79.69 ± 1.00% and 65.05 ± 1.23% for the porous- and rough-surface implants, respectively. Statistically significant difference was observed between the two types of implants with respect to the amount new bone formation (p<0.05). In conclusion, the porous-surface implants contributed to the osseointegration because they provide a larger contact area at implant-bone interface.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Pós-graduação em Engenharia Mecânica - FEG
Resumo:
The purpose of this study was to evaluate the possibility to obtaining guided bone regeneration utilizing a nonporous PTFE barrier in the osseointegrated implants, protruding from the bone level of the rabbit tíbia. The histologic characteristics of the interface between titanium implants, one group titanium-plasma coated, another group with acid-treated surfaces and the regenerated bone were also studied Twenty Screw-Vent implants were placed in tibias of five rabbits, two at the right side and two at the left side, protruding 3 mm from the bone level, to create a horizontal bone defect. ln the experimental side, the implants and adjacent bone were protected with a nonporous PTFE barrier. Histologic analysis after three months showed that all implants were in direct contact with the bane. Histologic measurements showed an average gain in bone height of the 2.15 and 2.42 mm for the barrier group and 1.95 and 0.43 mm for the control defects, in the titanium plasma-spray and acid-treated implant surfaces, respectively. The results suggest that the placement of implants protruding 3 mm from crestal bone defects may result in vertical bone augmentation and the regenerated bone is able to osseointegrate implants. lt seems to be critical the use of the PTFE barrier when acid-treated surface implants are inserted
Resumo:
OBJETIVO: Avaliar experimentalmente a biocompatibilidade de cones de biovidro e biovitrocerâmico em cavidades evisceradas de coelhos. MÉTODOS: Foram utilizados 45 coelhos albinos submetidos à cirurgia de evisceração do olho direito, seguida da inclusão de cones de biovidro e dois tipos de biovitrocerâmicos (chamados de FI e FII) na cavidade escleral. Os animais foram sacrificados em três momentos (7, 90 e 180 dias). Os parâmetros avaliados foram: peso, exame clínico diário, exames bioquímicos, avaliação histológica, exame morfométrico. RESULTADOS: Os animais mantiveram-se saudáveis durante o experimento, não tendo ocorrido extrusão do implante em nenhum animal. O exame morfológico mostrou que houve a formação de pseudocápsula ao redor dos cones, com superioridade dos cones de biovidro e biovitrocerâmico FI, os quais apresentaram menor reação inflamatória e menor formação da pseudocápsula ao redor dos cones que os demais. A reação inflamatória foi mais intensa após 7 dias da colocação dos cones, diminuindo em direção aos 180 dias, sendo menos intensa nos coelhos que receberam cones de biovidro. CONCLUSÃO: Os cones de biovidro e biovitrocerâmico FI e FII podem ser úteis para a reparação da cavidade anoftálmica, com melhor resposta quando se usa cones de biovidro e de biovitrocerâmico FI.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Engenharia Mecânica - FEB
Resumo:
Pós-graduação em Odontologia - FOA
Resumo:
O tratamento de escolha para a avulsão dentária é o reimplante dentário, no entanto diversos fatores interferem no prognóstico e a reabsorção radicular é a principal seqüela podendo levar a perda dentária. O objetivo do trabalho foi relatar um caso clínico de reimplante dentário com perda dentária por extensa reabsorção radicular e os planos de tratamento instituídos para reposição do dente perdido. Paciente após acidente motociclístico apresentou avulsão dentária e fratura coronária do elemento 21 e subluxação e fratura coronária do 11. Após quatro anos do reimplante o dente foi perdido por reabsorção radicular externa. Um novo plano de tratamento foi instituído e como a paciente apresentava uma maloclusão foi realizado um tratamento ortodôntico e uma cirurgia ortognática seguido da colocação de um implante para reposição do 21. Como não ocorreu a osseointegração do implante após três tentativas foi realizada uma prótese fixa adesiva associada à laminado de porcelana para o restabelecimento da função e a estética. Desta forma a interdisciplinaridade permitiu a elaboração de planos de tratamento, capaz de eliminar os imprevistos e conduzir o caso a um sucesso.
Resumo:
This work aimed to analyze clinically and histologically the allogen bone graft behavior at 6 and 9 months. A leukoderm, female, 55 years old patient sought dental care for oral rehabilitation with dental implants and implant supported fixed prosthesis in the maxilla. Bilateral sinus lifting procedure were performed in a same patient, the analysis were made after 6 and 9 months, respectively. At 6 months, there was lack of a better bone remodeling in the region, associated to the presence of fibrous connective tissue within the collected tissue, showing us that this is not the best stage of tissue maturation to place dental implants. The 9 months period showed an improvement, with a more organized bone tissue surrounding particles of homogenous bone, what possibly had increased implant stability at the time of surgery. There is no doubt about the increase of clinical applications of FFBA, but there are no studies available regarding the standardization of time to load implants inserted in allografts. So papers with long-term monitoring are necessary to eliminate questions that still remain to be answered.