Resumo:
A 4-year-old, female, Border Collie was presented to the University of Bern Veterinary Teaching Hospital, because of a corneal lesion of 10 days duration. The axial cornea presented a whitish fluorescein-positive plaque with irregular margins. A diagnosis of keratomycosis was made based on cytology. Medical therapy with local broad-spectrum antibiotic and fluconazole was instituted. After 1 week of treatment, the improvement was deemed unsatisfactory. Therefore, a lamellar keratectomy and conjunctival pedicle flap were performed. After surgery, the cornea healed uneventfully. Histology confirmed the diagnosis of keratomycosis. The fungus could not be grown in culture and a precise etiological diagnosis could only be obtained with genetic identification of the fungus. A PCR technique was used to amplify the fungal genome from the cornea. Hormographiella aspergillata, the asexual reproductive form of the basidiomycete Coprinopsis cinerea, was identified. As advised in human medicine, we encourage the use of this molecular technique to obtain an early species diagnosis, allowing targeted medical therapy.
Resumo:
BACKGROUND The Fractional Flow Reserve Versus Angiography for Multivessel Evaluation (FAME) 2 trial demonstrated a significant reduction in subsequent coronary revascularization among patients with stable angina and at least 1 coronary lesion with a fractional flow reserve ≤0.80 who were randomized to percutaneous coronary intervention (PCI) compared with best medical therapy. The economic and quality-of-life implications of PCI in the setting of an abnormal fractional flow reserve are unknown. METHODS AND RESULTS We calculated the cost of the index hospitalization based on initial resource use and follow-up costs based on Medicare reimbursements. We assessed patient utility using the EQ-5D health survey with US weights at baseline and 1 month and projected quality-adjusted life-years assuming a linear decline over 3 years in the 1-month utility improvements. We calculated the incremental cost-effectiveness ratio based on cumulative costs over 12 months. Initial costs were significantly higher for PCI in the setting of an abnormal fractional flow reserve than with medical therapy ($9927 versus $3900, P<0.001), but the $6027 difference narrowed over 1-year follow-up to $2883 (P<0.001), mostly because of the cost of subsequent revascularization procedures. Patient utility was improved more at 1 month with PCI than with medical therapy (0.054 versus 0.001 units, P<0.001). The incremental cost-effectiveness ratio of PCI was $36 000 per quality-adjusted life-year, which was robust in bootstrap replications and in sensitivity analyses. CONCLUSIONS PCI of coronary lesions with reduced fractional flow reserve improves outcomes and appears economically attractive compared with best medical therapy among patients with stable angina.
Resumo:
BACKGROUND Cardiac surgery with cardiopulmonary bypass is associated with mechanical manipulation of the ascending aorta that occasionally leads to type A aortic dissection (AAD). METHODS AND RESULTS One hundred three patients with surgical repair for AAD following nonaortic cardiac surgery were identified. With the use of logistic regression modeling, coronary artery bypass surgery (CABG), either isolated or combined with another procedure in the initial operation, was associated with significantly higher operative mortality in comparison with patients with non-CABG procedures at the time of AAD repair both for all patients (odds ratio, 2.90; 95% confidence interval, 1.09-7.72; P=0.033) and for patients with acute and chronic AAD≥30 days after the initial operation (odds ratio, 3.62; 95% confidence interval, 1.13-11.54; P=0.03). In patients who developed AAD late after the initial operation, operative mortality was highest in patients without preoperative coronary angiography and appropriate management of their native coronary artery disease and graft disease (odds ratio, 5.36; 95% confidence interval, 1.68-17.0; P=0.002). Nearly all the intimal dissection tears were located at sites of previous surgical trauma. Most of the ascending aortas that had dissected initially had a diameter≥40 mm with histological evidence of medial degeneration in resected tissue samples. CONCLUSIONS In patients who have undergone previous cardiac surgery, preexisting aortic wall pathology contributes to AAD with typical intimal damage at sites of mechanical trauma. The operative mortality was the highest in patients with previous CABG in comparison with patients with non-CABG procedures. Preoperative coronary angiography and operative management of native coronary and graft disease were significantly associated with outcome in patients with previous CABG.
Resumo:
Aims: To assess observations with multimodality imaging of the Absorb bioresorbable everolimus-eluting vascular scaffold performed in two consecutive cohorts of patients who were serially investigated either at 6 and 24 months or at 12 and 36 months. Methods and results: In the ABSORB multicentre single-arm trial, 45 patients (cohort B1) and 56 patients (cohort B2) underwent serial invasive imaging, specifically quantitative coronary angiography (QCA), intravascular ultrasound (IVUS), radiofrequency backscattering (IVUS-VH) and optical coherence tomography (OCT). Between one and three years, late luminal loss remained unchanged (6 months: 0.19 mm, 1 year: 0.27 mm, 2 years: 0.27 mm, 3 years: 0.29 mm) and the in-segment angiographic restenosis rate for the entire cohort B (n=101) at three years was 6%. On IVUS, mean lumen, scaffold, plaque and vessel area showed enlargement up to two years. Mean lumen and scaffold area remained stable between two and three years whereas significant reduction in plaque behind the struts occurred with a trend toward adaptive restrictive remodelling of EEM. Hyperechogenicity of the vessel wall, a surrogate of the bioresorption process, decreased from 23.1% to 10.4% with a reduction of radiofrequency backscattering for dense calcium and necrotic core. At three years, the count of strut cores detected on OCT increased significantly, probably reflecting the dismantling of the scaffold; 98% of struts were covered. In the entire cohort B (n=101), the three-year major adverse cardiac event rate was 10.0% without any scaffold thrombosis. Conclusions: The current investigation demonstrated the dynamics of vessel wall changes after implantation of a bioresorbable scaffold, resulting at three years in stable luminal dimensions, a low restenosis rate and a low clinical major adverse cardiac events rate.
Resumo:
BACKGROUND The safety and efficacy of drug-eluting stents (DES) in the treatment of coronary artery disease have been assessed in several randomised trials. However, none of these trials were powered to assess the safety and efficacy of DES in women because only a small proportion of recruited participants were women. We therefore investigated the safety and efficacy of DES in female patients during long-term follow-up. METHODS We pooled patient-level data for female participants from 26 randomised trials of DES and analysed outcomes according to stent type (bare-metal stents, early-generation DES, and newer-generation DES). The primary safety endpoint was a composite of death or myocardial infarction. The secondary safety endpoint was definite or probable stent thrombosis. The primary efficacy endpoint was target-lesion revascularisation. Analysis was by intention to treat. FINDINGS Of 43,904 patients recruited in 26 trials of DES, 11,557 (26·3%) were women (mean age 67·1 years [SD 10·6]). 1108 (9·6%) women received bare-metal stents, 4171 (36·1%) early-generation DES, and 6278 (54·3%) newer-generation DES. At 3 years, estimated cumulative incidence of the composite of death or myocardial infarction occurred in 132 (12·8%) women in the bare-metal stent group, 421 (10·9%) in the early-generation DES group, and 496 (9·2%) in the newer-generation DES group (p=0·001). Definite or probable stent thrombosis occurred in 13 (1·3%), 79 (2·1%), and 66 (1·1%) women in the bare-metal stent, early-generation DES, and newer-generation DES groups, respectively (p=0·01). The use of DES was associated with a significant reduction in the 3 year rates of target-lesion revascularisation (197 [18·6%] women in the bare-metal stent group, 294 [7·8%] in the early-generation DES group, and 330 [6·3%] in the newer-generation DES group, p<0·0001). Results did not change after adjustment for baseline characteristics in the multivariable analysis. INTERPRETATION The use of DES in women is more effective and safe than is use of bare-metal stents during long-term follow-up. Newer-generation DES are associated with an improved safety profile compared with early-generation DES, and should therefore be thought of as the standard of care for percutaneous coronary revascularisation in women. FUNDING Women in Innovation Initiative of the Society of Cardiovascular Angiography and Interventions.
Resumo:
Aims: To evaluate the accuracy and reproducibility of aortic annulus sizing using a multislice computed tomography (MSCT) based aortic root reconstruction tool compared with conventional imaging among patients evaluated for transcatheter aortic valve replacement (TAVR). Methods and results: Patients referred for TAVR underwent standard preprocedural assessment of aortic annulus parameters using MSCT, angiography and transoesophageal echocardiography (TEE). Three-dimensional (3-D) reconstruction of MSCT images of the aortic root was performed using 3mensio (3mensio Medical Imaging BV, Bilthoven, The Netherlands), allowing for semi-automated delineation of the annular plane and assessment of annulus perimeter, area, maximum, minimum and virtual diameters derived from area and perimeter (aVD and pVD). A total of 177 patients were enrolled. We observed a good inter-observer variability of 3-D reconstruction assessments with concordance coefficients for agreement of 0.91 (95% CI: 0.87-0.93) and 0.91 (0.88-0.94) for annulus perimeter and area assessments, respectively. 3-D derived pVD and aVD correlated very closely with a concordance coefficient of 0.97 (0.96-0.98) with a mean difference of 0.5±0.3 mm (pVD-aVD). 3-D derived pVD showed the best, but moderate concordance with diameters obtained from coronal MSCT (0.67, 0.56-0.75; 0.3±1.8 mm), and the lowest concordance with diameters obtained from TEE (0.42, 0.31-0.52; 1.9±1.9 mm). Conclusions: MSCT-based 3-D reconstruction of the aortic annulus using the 3mensio software enables accurate and reproducible assessment of aortic annulus dimensions.
Resumo:
OBJECTIVES To assess prevalence of anemia and its correlation with NYHA-class in patients with congestive heart failure. BACKGROUND Recently, it was reported that anemia in congestive heart failure patients is common and correlated with the severity of disease. In these patients with anemia, treatment with erythropoietin and intravenous iron improved cardiac function significantly. METHODS 193 patients from a tertiary heart failure outpatient clinic (mean age 54 years) were included in a retrospective analysis. Fourteen patients were in NYHA-class I, 69 class II, 79 class III, and 31 class IV. All patients had clinical and laboratory evaluation, echocardiography and coronary angiography. Patients with secondary anemia or on hemodialysis were excluded. Etiology of heart failure was ischemic in 41%. RESULTS Anemia (hemoglobin<120 g/l) was present in 28 of 193 patients (15%). There was an inverse relationship between NYHA-class and left ventricular ejection fraction (NYHA-class I 45%, class II 32%, class III 25%, class IV 25%). Serum creatinine increased with NYHA-class. Hemoglobin levels were similar in all four NYHA-classes but there were significantly more patients with anemia in NYHA-class III and IV (19%) compared with class I and II (8%, P<0.05). Hemoglobin was similar in surviving patients (mean 140 g/l) and those who died or were transplanted (mean 136 g/l, ns). CONCLUSIONS The prevalence of anemia in our heart failure service is 15% (compared with 56% in the literature) and is correlated to NYHA-class.
Resumo:
INTRODUCTION Catheter ablation for idiopathic ventricular arrhythmia is well established but epicardial origin, proximity to coronary arteries, and limited accessibility may complicate ablation from the venous system in particular from the great cardiac vein (GCV). METHODS Between April 2009 and October 2010 14 patients (56 ± 15 years; 9 male) out of a total group of 117 patients with idiopathic outflow tract tachycardias were included undergoing ablation for idiopathic VT or premature ventricular contractions (PVC) originating from GCV. All patients in whom the PVC arose from the GCV were subject to the study. In these patients angiography of the left coronary system was performed with the ablation catheter at the site of earliest activation. RESULTS Successful ablation was performed in 6/14 (43%) and long-term success was achieved in 5/14 (36%) patients. In 4/14 patients (28.6%) ablation was not performed. In another 4 patients (26.7%), ablation did not abolish the PVC/VT. In the majority, the anatomical proximity to the left coronary system prohibited effective RF application. In 3 patients RF application resulted in a coronary spasm with complete regression as revealed in repeat coronary angiography. CONCLUSION A relevant proportion idiopathic VT/PVC can safely be ablated from the GCV without significant permanent coronary artery stenosis after RF application. Our data furthermore demonstrate that damage to the coronary artery system is likely to be transient.
Resumo:
BACKGROUND To report on anti-CD20 antibody therapy in a patient with uveitis refractive to immunosuppression therapy. METHODS Case report with ophthalmoscopic, optical coherence tomography and fluorescein-angiographic findings. RESULTS A 49-year-old woman was suffering from bilateral, noninfectious chronic anterior uveitis refractive to corticosteroids and immunosuppressive drugs. Bilateral visual acuity was 20/100 due to cataract and cystoid macular edema (CME). After treatment with rituximab, vision and CME improved, and uveitis was stable until the final visit (follow-up at 12 months). CONCLUSION The case report suggests that rituximab may be helpful for selected patients with chronic anterior uveitis refractive to corticosteroids and immunosuppressive medication.
Resumo:
OBJECTIVES This study sought to determine the vascular anatomical eligibility for catheter-based renal artery denervation (RDN) in hypertensive patients. BACKGROUND Arterial hypertension is the leading cardiovascular risk factor for stroke and mortality globally. Despite substantial advances in drug-based treatment, many patients do not achieve target blood pressure levels. To improve the number of controlled patients, novel procedure- and device-based strategies have been developed. RDN is among the most promising novel techniques. However, there are few data on the vascular anatomical eligibility. METHODS We retrospectively analyzed 941 consecutive hypertensive patients undergoing coronary angiography and selective renal artery angiography between January 1, 2010, and May 31, 2012. Additional renal arteries were divided into 2 groups: hilar (accessory) and polar (aberrant) arteries. Anatomical eligibility for RDN was defined according to the current guidelines: absence of renal artery stenosis, renal artery diameter ≥4 mm, renal artery length ≥20 mm, and only 1 principal renal artery. RESULTS A total of 934 hypertensive patients were evaluable. The prevalence of renal artery stenosis was 10% (n = 90). Of the remaining 844 patients without renal artery stenosis, 727 (86%) had nonresistant hypertension and 117 (14%) had resistant hypertension; 62 (53%) of the resistant hypertensive and 381 (52%) of the nonresistant hypertensive patients were anatomically eligible for sympathetic RDN. CONCLUSIONS The vascular anatomical eligibility criteria of the current guidelines are a major limiting factor for the utilization of RDN as a therapeutic option. Development of new devices and/or techniques may significantly increase the number of candidates for these promising therapeutic options.
Resumo:
Purpose: To quantify the in vivo deformations of the popliteal artery during leg flexion in subjects with clinically relevant peripheral artery disease (PAD). Methods: Five patients (4 men; mean age 69 years, range 56–79) with varying calcification levels of the popliteal artery undergoing endovascular revascularization underwent 3-dimensional (3D) rotational angiography. Image acquisition was performed with the leg straight and with a flexion of 70°/20° in the knee/hip joints. The arterial centerline and the corresponding branches in both positions were segmented to create 3D reconstructions of the arterial trees. Axial deformation, twisting, and curvatures were quantified. Furthermore, the relationships between the calcification levels and the deformations were investigated. Results: An average shortening of 5.9%±2.5% and twist rate of 3.8±2.2°/cm in the popliteal artery were observed. Maximal curvatures in the straight and flexed positions were 0.12±0.04 cm−1 and 0.24±0.09 cm−1, respectively. As the severity of calcification increased, the maximal curvature in the straight position increased from 0.08 to 0.17 cm−1, while an increase from 0.17 to 0.39 cm−1 was observed for the flexed position. Axial elongations and arterial twisting were not affected by the calcification levels. Conclusion: The popliteal artery of patients with symptomatic PAD is exposed to significant deformations during flexion of the knee joint. The severity of calcification directly affects curvature, but not arterial length or twisting angles. This pilot study also showed the ability of rotational angiography to quantify the 3D deformations of the popliteal artery in patients with various levels of calcification.
Resumo:
OBJECTIVE Well-developed collaterals provide survival benefit in patients with obstructive coronary artery disease (CAD). Therefore, in this study we sought to determine which clinical variables are associated with arteriogenesis. DESIGN Clinical and laboratory variables were collected before percutaneous coronary intervention. Multivariate analysis was performed to determine which variables are associated with the collateral flow index (CFI). PATIENTS Data from 295 chronic total occlusion (CTO) patients (Bern, Switzerland, Amsterdam, the Netherlands and Jena, Germany) were pooled. In earlier studies, patients had varying degrees of stenosis. Therefore, different stages of development of the collaterals were used. In our study, a unique group of patients with CTO was analysed. INTERVENTIONS Instead of angiography used earlier, we used a more accurate method to determine CFI using intracoronary pressure measurements. CFI was calculated from the occlusive pressure distal of the coronary lesion, the aortic pressure and central venous pressure. RESULTS The mean CFI was 0.39 ± 0.14. After multivariate analysis, β blockers, hypertension and angina pectoris duration were positively associated with CFI (B: correlation coefficient β=0.07, SE=0.03, p=0.02, B=0.040, SE=0.02, p=0.042 and B=0.001, SE=0.000, p=0.02). Furthermore also after multivariate analysis, high serum leucocytes, prior myocardial infarction and high diastolic blood pressure were negatively associated with CFI (B=-0.01, SE=0.005, p=0.03, B=-0.04, SE=0.02, p=0.03 and B=-0.002, SE=0.001, p=0.011). CONCLUSIONS In this unique cohort, high serum leucocytes and high diastolic blood pressure are associated with poorly developed collaterals. Interestingly, the use of β blockers is associated with well-developed collaterals, shedding new light on the potential action mode of this drug in patients with CAD.
Resumo:
Aims: Angiographic evidence of edge dissections has been associated with a risk of early stent thrombosis. Optical coherence tomography (OCT) is a high-resolution technology detecting a greater number of edge dissections -particularly non-flow-limiting- compared to angiography. Their natural history and clinical implications remain unclear. The objectives of the present study were to assess the morphology, healing response, and clinical outcomes of OCT-detected edge dissections using serial OCT imaging at baseline and at one year following drug-eluting stent (DES) implantation. Methods and results: Edge dissections were defined as disruptions of the luminal surface in the 5 mm segments proximal and distal to the stent, and categorised as flaps, cavities, double-lumen dissections or fissures. Qualitative and quantitative OCT analyses were performed every 0.5 mm at baseline and one year, and clinical outcomes were assessed. Sixty-three lesions (57 patients) were studied with OCT at baseline and one-year follow-up. Twenty-two non-flow-limiting edge dissections in 21 lesions (20 patients) were identified by OCT; only two (9%) were angiographically visible. Flaps were found in 96% of cases. The median longitudinal dissection length was 2.9 mm (interquartile range [IQR] 1.6-4.2 mm), whereas the circumferential and axial extensions amounted to 1.2 mm (IQR: 0.9-1.7 mm) and 0.6 mm (IQR: 0.4-0.7 mm), respectively. Dissections extended into the media and adventitia in seven (33%) and four (20%) cases, respectively. Eighteen (82%) OCT-detected edge dissections were also evaluated with intravascular ultrasound which identified nine (50%) of these OCT-detected dissections. No stent thrombosis or target lesion revascularisation occurred up to one year. At follow-up, 20 (90%) edge dissections were completely healed on OCT. The two cases exhibiting persistent dissection had the longest flaps (2.81 mm and 2.42 mm) at baseline. Conclusions: OCT-detected edge dissections which are angiographically silent in the majority of cases are not associated with acute stent thrombosis or restenosis up to one-year follow-up.
Neoatherosclerosis as reason for stent failures beyond 5 years after drug-eluting stent implantation
Resumo:
A 69-year-old male (case 1) was admitted due to acute non-ST-segment elevation myocardial infarction (NSTEMI). Eight years earlier, he had previously undergone treatment with a sirolimus-eluting stent (SES). Four years after stent implantation, a follow-up angiography was obtained showing a patent stent without obstructive in-stent restenosis (Panel A). Angiograms obtained at the time of NSTEMI (Panel B) disclosed subtotal occlusion in the middle of the SES (arrowheads). Optical coherence tomography revealed a signal intense luminal layer with an underlying, highly attenuating, diffusely demarcated area, suggestive for an instent fibroatheroma (Panel D) with a minimal cap thickness of 80 µm. Accordingly, ischaemia was caused by the high degree of stenosis (Panel E). Similarly, a 59-year-old male (case 2) was admitted due to STEMI. Nine years before, he had received a paclitaxel-eluting stent (PES). Five years after stent implantation, a follow-up angiography revealed a patent stent (Panel F). Angiograms obtained at the time of STEMI (Panel G) disclosed total occlusion in the proximal of PES (arrowheads). Optical coherence tomography showed a rupture of thin cap fibroatheroma within the stented segment (Panel I). The thin cap fibroatheroma caused a severe stenosis with superimposed thrombus (Panel J). Neoatherosclerosis has been recently described as particular disease entity being responsible for very late stent failures. These two cases illustrate that the presence of a favourable long-term angiographic result years after DES implantation does not exclude a future neoatherosclerosis-related event (restenosis or stent thrombosis). Large observational and long-term intracoronary imaging studies are required to fully elucidate the dynamics and clinical relevance of neoatherosclerosis.
Resumo:
Objective: Perimedullary arteriovenous fistulas (PMAVF) are exceptional spinal vascular malformations and their best therapeutic management remains controversial. Here the authors present their experience with PMAVF to characterize the clinical, neuroimaging and treatment data of patients operated on PMAVF and to analyse both incidence of complications and resurgery in the microsurgical therapy of PMAVF. Method: Fifteen patients (13 men, 2 women, mean age 51 years) with PMAVF identified by selective spinal angiography were microsurgically treated at our institution between 1992 and 2006. The presenting symptoms (duration 3 months to 5 years) were consistent with progressive myelopathy (13) or included isolated pain syndrome (2). Lumbar PMAVF location (6) was predominant followed by the sacral (5) and thoracic (4) site including 6 PMAVF of the filum terminale and 2 PMAVF associated with a glomerular AVM and dural arteriovenous fistula, respectively. Microsurgical PMAVF obliteration and postoperative angiography were routinely performed. All patients were available for follow-up evaluation within 6 months postoperatively. Results: Surgery with complete (12) or almost complete (3) PMAVF occlusion resulted in neurological improvement (10) or stabilization (1), 4 patients deteriorated postoperatively. Whereas no complications occured, a second operation because of residual or recanalized PMAVF was indicated in one case each. Two associated dual spinal vascular malformations could be observed and subsequently obliterated. Conclusions: Microsurgical occlusion of PMAVF appears to be a secure and adequate therapeutic option that prevents progressive neurological deterioration and results in good outcome in the majority of patients. Complications associated with surgery, recurrences and reoperations are infrequent. Therefore, in the authors experience microsurgery is the preferred therapy to treat PMAVF. Despite the rarity of PMAVF the possibility of the coincidence of associated second vascular malformations should be considered.