986 resultados para dose escalation


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pós-graduação em Agronomia (Produção Vegetal) - FCAV

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pós-graduação em Pesquisa e Desenvolvimento (Biotecnologia Médica) - FMB

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pós-graduação em Zootecnia - FCAV

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The goal of this project is the reproduction, through the simulation code based on the MCNPX (Monte Carlo N-Particle eXtended) v2.50 method, of the proton beam interaction with the material, since, in proton therapy, only the particle ionization and excitation are analyzed and the occurence of nuclear interactive inelastic process are not considered. This work will help the development of studies concerning the contribution to the total dosis of secondary particles generated by nuclear interaction in proton therapy. They are: alpha particles ( ), deuterium(2H), tritium (3H), neutron (n) and helium (3He). A MS20 tissue substitute phantom was used as the target and the energy of the proton beams was within an interest range of 100 to 200MeV. With the results obtained, it was possible to generate graphics which allows the analysis of the dosis deposition relation with and without nuclear interaction, the percentage of secondary particles deposited dosis, the radial dispersion of neutrons in the material, the secondary particles multiplicity, as well as the relation between the secondary particles spectrum with the próton generated spectrum

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Since discovery, computed tomography is a widely used diagnostic modality. However, this modality imparts relatively high doses to the patients and with fast technological advancement, it is necessary optimize the doses used and ensure the quality of the images through a quality assurance program. This work intended to compare Computed Tomography Dose Index (CTDIW) and effective dose with components of image quality: the Contrast-to-Noise Ratio (CNR) and Signal-to-Noise Ratio (SNR), and a quality factor (Q) deduced by the Rose model for two groups of computed tomography units. The first group was composed by equipments with 10 up to 16 slices and the second one presented 40 up to 320 slices detectors, for the protocols of head and abdomen. It was realized a comparison between different selectable parameters in the protocol of a Philips Brilliance 16, too. The results of the first group to CTDIW, effective dose, SNR and CNR showed variations of 28%, 33%, 37% and 32% respectively for head protocol, and 21%, 27%, 43% and 37% respectively for abdomen protocol. The results of the group 2 to CTDIW, effective dose, SNR and CNR showed variations of 15%, 26%, 36% and 34% respectively for the head protocol, and 8%, 13%, 50% and 60% respectively for abdomen protocol. The comparison between both groups demonstrated similar levels of doses impartation to patients though having so many different configurations, if the uncertainties associated with this measurement were considered. The results of the comparison between different parameters in the Philips Brilliance 16 scanner were in agreement with expected

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The brachytherapy braquiterapia is an x-ray modality radiotherapy in which stamped or halfstamped radioactive sources in format of seeds are used, wires or to one short distance, in contact or implanted to the fabric to be treated. All the treatment modalities require a previous planning. The formalism recommended for calculation of dose was considered by the AAPM for the first TG-43 Report. In it distributions of dose of isolated seeds measured and calculated by Monte Carlo method in water instead of with models half-empiricists. In this work we in accordance with present some preliminary results of the calculation of functions of radial anisotropy and of dose in the distance for seed of 192Ir, wide used in brachytherapy treatments of high tax of dose (HDR), with the aid of the program based on the Monte Carlo method MCNPX v2.50 (Mount Carlo N ParticleeXtended). The materials chosen in the simulation beyond water, had been MS20 and estriado muscle

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The brachytherapy braquiterapia is an x-ray modality radiotherapy in which stamped or halfstamped radioactive sources in format of seeds are used, wires or to one short distance, in contact or implanted to the fabric to be treated. All the treatment modalities require a previous planning.The formalism recommended for calculation of dose was considered by the AAPM for the first TG-43 Report. In it distributions of dose of isolated seeds measured and calculated by Monte Carlo method in water instead of with models half-empiricists.In this work we in accordance with present some preliminary results of the calculation of functions of radial anisotropy and of dose in the distance for seed of 192Ir, wide used in brachytherapy treatments of high tax of dose (HDR), with the aid of the program based on the Monte Carlo method MCNPX v2.50 (Mount Carlo N ParticleeXtended).The materials chosen in the simulation beyond water, had been MS20 and estriado muscle

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Due the differences between interaction physics process with matter for protons and photons, the proton beam tomography (pCT) has some vantages to comparison with conventional tomography. Also it is confirmed that usually pCT has better dose distribution and highest contrast resolution. The pCT allow not only view the internal structure of an object without destroying it, but also directly measure of volume density of electrons. Also it is confirmed that usually pCT has better dose distribution and highest contrast resolution. At the same time, there are many scientific and technical aspects to a detailed study: the capacity and limitations of the pCT methods are not well clarified. Through computations, based on Monte Carlo Method was carried out a detailed study of the contribution of non-elastic nuclear spreading, and together was compared with an analytical model for the deflection angle and the lateral deflection of protons in the target volume. The programs used were SRIM 2006 code and MCNPX v.2.50 code

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the treatment plans in conventional Proton therapy are considered only the elastic interactions of protons with electrons and/or nuclei, it means, mainly ionization and coulomb excitation processes. As the energy needed to reach the deep tumors should be of several hundred of MeVs, certainly the nuclear inelastic channels are open. Only some previous studies of the contribution of these processes in the full dose have been made towards targets composed of water. In this study will be presented the results of the simulation of the processes of interaction of beams of protons in the range of 100-200 MeV of energy with a cylindrical phantom composed by striated muscle (ICRU), emphasizing in the contribution to total dose due to the deposition of energy by secondary particles alpha (α), deuterium (2H), tritium (3H), neutron (n) and hélio3 (3He), originated by nuclear inelastic processes. The simulations were performed by using the method of Monte Carlo, via the computer code MCNPX v2.50 (Monte Carlo N-Particle eXtended). The results will be shown demonstrated through the graphics of the deposited dose with or without nuclear interaction, the percentual of dose deposited by secondary particles, the radial dispersion of neutrons, as well as the multiplicity of secondary particles

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Nowadays cancer is one of the main causes of death and many efforts worldwide have been driven to find out new treatments and approaches in order to extinguish or reduce this group of disorder. Chemotherapy is the main treatment for cancer, however, conventional schedule based on maximum tolerated dose (MTD) show several side effects and frequently allow the development of drug resistance. In this review we present the evidence that metronomic chemotherapy, based on the frequent administration of low or intermediate doses of chemotherapeutics is as efficient as MTD and works better in some situations. Finally, we present some data indicating that noncytotoxic concentrations of antineoplastic agents are able to both up-regulate the immune system and increase the susceptibility of tumor cells to cytotoxic T lymphocytes. Taken together, data from the literature provide us the evidence that low concentrations of selected chemotherapeutics agents, rather than conventional high doses, should be chosen for combination with immunotherapy

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In proton therapy, the deposition of secondary particles energy originated by nuclear inelastic process (n, 2H, 3H, 3He and α) has a contribution in the total dose that deserves to be discussed. In calculations of plans implemented for routine treatment, the paid dose is calculated whereas the proton loses energy by ionization and or coulomb excitement. The contribution of inelastic processes associated with nuclear reactions is not considered. There are only estimates for pure materials or simple composition (water, for example), because of the difficulty of processing targets consisting of different materials. For this project, we use the Monte Carlo method employing the code MCNPX v2.50 (Monte Carlo N-Particle eXtended) to present results of the contribution to the total dose of secondary particles. In this work, it was implemented a cylindrical phantom composed by cortical bone, for proton beams between 100 and 200 MeV. With the results obtained, it was possible to generate graphics to analyze: the dose deposition relation with and without nuclear interaction, the multiplicity and percentage of deposited dose for each secondary particle and a radial dispersion of neutrons in the material