967 resultados para bimodal size distribution
Resumo:
The unique properties of ceramic foams enable their use in a variety of applications. This work investigated the effects of different parameters on the production of zirconia ceramic foam using the sol-gel process associated with liquid foam templates. Evaluation was made of the influence of the thermal treatment temperature on the porous and crystalline characteristics of foams manufactured using different amounts of sodium dodecylsulfate (SDS) surfactant. A maximum pore volume, with high porosity (94%) and a bimodal pore size distribution, was observed for the ceramic foam produced with 10% SDS. Macropores, with an average size of around 30 μm, were obtained irrespective of the SDS amount, while the average size of the supermesopores increased systematically as the SDS amount was increased up to 10%, after which it decreased. X-ray diffraction analyses showed that the sample treated at 500 °C was amorphous, while crystallization into a tetragonal metastable phase occurred at 600 °C due to the presence of sulfate groups in the zirconia structure. At 800 and 1000 °C the monoclinic phase was observed, which is thermodynamically stable at these temperatures. © 2013 by the authors; licensee MDPI, Basel, Switzerland.
Resumo:
Pós-graduação em Química - IQ
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
In situ megascale hydraulic diffusivities (D) of a confined loess aquifer were estimated at various scales (10 <= L <= 1500 m) by a finite difference model, and laboratory microscale diffusivities of a loess sample by empirical formulas. A scatter plot reveals that D fits to a single power function of L, providing that microscale diffusivities are assigned to L = 1 m and that differences in diffusivity observed between micro- and megascales are assigned to medium heterogeneity appraised by variations in the curvature and slope of natural hydraulic head waves propagating through the aquifer. Subsequently, a general power relationship between D and L is defined where the base and exponent terms stand for the aquifer storage capability under a confined regime of flow, for the microscale hydraulic conductivity and specific yield of loess, and for the changes in curvature and slope of hydraulic head waves relative to values defined at unit scale.[GRAPHICS]Editor Z.W. Kundzewicz
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
The relative growth and population structure of the terebellid Nicolea uspiana were investigated in the intertidal zone of a rocky shore on the south-east coast of Brazil, from May 2006 to May 2007. Eight hundred and forty-seven individuals of N. uspiana were analysed: 391 males, 163 females, and 293 immatures. Although significant differences in some morphometric parameters were found, there was no sexual dimorphism between males and females. There were differences in total length, width of segments, and length of the notopodial region between matures and immatures. The negative allometry of the total length in relation to five other parameters showed that this feature is a good measure for estimating the individual size, which was then used in the analysis of population structure. This population of N. uspiana showed a bimodal size frequency distribution, with immature and mature individuals found during the entire year. This pattern indicates continuous reproduction, with each cohort growing for at least three to four months and being responsible for two consecutive settlement peaks.
Resumo:
As a part of the AMAZE-08 campaign during the wet season in the rainforest of central Amazonia, an ultraviolet aerodynamic particle sizer (UV-APS) was operated for continuous measurements of fluorescent biological aerosol particles (FBAP). In the coarse particle size range (> 1 mu m) the campaign median and quartiles of FBAP number and mass concentration were 7.3x10(4) m(-3) (4.0-13.2x10(4) m(-3)) and 0.72 mu g m(-3) (0.42-1.19 mu g m(-3)), respectively, accounting for 24% (11-41%) of total particle number and 47% (25-65%) of total particle mass. During the five-week campaign in February-March 2008 the concentration of coarse-mode Saharan dust particles was highly variable. In contrast, FBAP concentrations remained fairly constant over the course of weeks and had a consistent daily pattern, peaking several hours before sunrise, suggesting observed FBAP was dominated by nocturnal spore emission. This conclusion was supported by the consistent FBAP number size distribution peaking at 2.3 mu m, also attributed to fungal spores and mixed biological particles by scanning electron microscopy (SEM), light microscopy and biochemical staining. A second primary biological aerosol particle (PBAP) mode between 0.5 and 1.0 mu m was also observed by SEM, but exhibited little fluorescence and no true fungal staining. This mode may have consisted of single bacterial cells, brochosomes, various fragments of biological material, and small Chromalveolata (Chromista) spores. Particles liquid-coated with mixed organic-inorganic material constituted a large fraction of observations, and these coatings contained salts likely from primary biological origin. We provide key support for the suggestion that real-time laser-induce fluorescence (LIF) techniques using 355 nm excitation provide size-resolved concentrations of FBAP as a lower limit for the atmospheric abundance of biological particles in a pristine environment. We also show some limitations of using the instrument for ambient monitoring of weakly fluorescent particles < 2 mu m. Our measurements confirm that primary biological particles, fungal spores in particular, are an important fraction of supermicron aerosol in the Amazon and that may contribute significantly to hydrological cycling, especially when coated by mixed inorganic material.
Resumo:
This study deals with the seasonal distribution of Al, Ca, Cu, Fe, K, Mg, Na, Pb and Zn and water soluble ions (Cl-, PO43-, NO3-, SO42-, HCOO-, CH3COO-, oxalate, succinate, Na+, NH4+, K+, Mg2+ and Ca2+) found in PM10 samples (particulate matter less than 10 mu m in diameter) Sao Paulo City, Brazil, (April 2003-May 2004). Higher atmospheric levels were found for SO42-, NO3-, Cl- and PO43- while the main organic anions were oxalate and formate. Atmospheric levels for elements were: Fe > Al > Ca > K > Na > Mg > Zn > Cu > Pb. Some sources were predominant for some species: (i) fuel burning and/or biomass burning (NO3-, HCOO-, C2O42-, K+, Mg2+, Ca2+, Fe, Pb, Zn, Al, Ca, K and Mg), (ii) gas-to-particle conversion (SO42- and NH4+) and (iii) sea salt spray (Cl-, Na+ and Na).
Resumo:
In this study, the measurement of the concentration and size of particles and the identification of their sources were carried out at five orthopedic surgeries. The aerosol concentration and particle size distribution, ranging from 0.3 mu m 10 mu m, were measured and related to the type of indoor activity. The handling of surgical linen and gowns, handling of the patient, use of electrosurgical apparatus, use of a bone saw, handling of equipment, and cleaning of the room were identified as the most important sources of particles, with each of these activities posing different risks to the health of the patients and workers. The results showed that most of the particles were above 0.5 mu m and that there was a strong correlation among all particles of sizes above 1 mu m. Particles with diameters in the range of 0.3 mu m-0.5 mu m had a good correlation only with particles in the ranges of 0.5 mu m-1.0 mu m and 1.0 mu m-3.0 mu m in three of the surgeries analyzed. Findings led to the conclusion that most of the events responsible for generating aerosol particles in an orthopedic surgery room are brief, intermittent, and highly variable, thus requiring the use of specific instrumentation for their continuous identification and characterization.
Resumo:
Body size influences wing shape and associated muscles in flying animals which is a conspicuous phenomenon in insects, given their wide range in body size. Despite the significance of this, to date, no detailed study has been conducted across a group of species with similar biology allowing a look at specific relationship between body size and flying structures. Neotropical social vespids are a model group to study this problem as they are strong predators that rely heavily on flight while exhibiting a wide range in body size. In this paper we describe the variation in both wing shape, as wing planform, and mesosoma muscle size along the body size gradient of the Neotropical social wasps and discuss the potential factors affecting these changes. Analyses of 56 species were conducted using geometric morphometrics for the wings and lineal morphometrics for the body; independent contrast method regressions were used to correct for the phylogenetic effect. Smaller vespid species exhibit rounded wings, veins that are more concentrated in the proximal region, larger stigmata and the mesosoma is proportionally larger than in larger species. Meanwhile, larger species have more elongated wings, more distally extended venation, smaller stigmata and a proportionally smaller mesosoma. The differences in wing shape and other traits could be related to differences in flight demands caused by smaller and larger body sizes. Species around the extremes of body size distribution may invest more in flight muscle mass than species of intermediate sizes.
Resumo:
Large fine mode-dominated aerosols (submicron radius) in size distributions retrieved from the Aerosol Robotic Network (AERONET) have been observed after fog or low-altitude cloud dissipation events. These column-integrated size distributions have been obtained at several sites in many regions of the world, typically after evaporation of low-altitude cloud such as stratocumulus or fog. Retrievals with cloud-processed aerosol are sometimes bimodal in the accumulation mode with the larger-size mode often similar to 0.4-0.5 mu m radius (volume distribution); the smaller mode, typically similar to 0.12 to similar to 0.20 mu m, may be interstitial aerosol that were not modified by incorporation in droplets and/or aerosol that are less hygroscopic in nature. Bimodal accumulation mode size distributions have often been observed from in situ measurements of aerosols that have interacted with clouds, and AERONET size distribution retrievals made after dissipation of cloud or fog are in good agreement with particle sizes measured by in situ techniques for cloud-processed aerosols. Aerosols of this type and large size range (in lower concentrations) may also be formed by cloud processing in partly cloudy conditions and may contribute to the "shoulder" of larger-size particles in the accumulation mode retrievals, especially in regions where sulfate and other soluble aerosol are a significant component of the total aerosol composition. Observed trends of increasing aerosol optical depth (AOD) as fine mode radius increased suggests higher AOD in the near-cloud environment and higher overall AOD than typically obtained from remote sensing owing to bias toward sampling at low cloud fraction.
Resumo:
In this thesis methods of EPR spectroscopy were used to investigate polyion-counterion interactions in polyelectrolyte solutions. The fact that EPR techniques are local methods is exploited and by employing spin-carrying (i.e., EPR-active) probe ions it is possible to examine polyelectrolytes from the counterions point of view. It was possible to gain insight into i) the dynamics and local geometry of counterion attachment, ii) conformations and dynamics of local segments of the polyion in an indirect manner, and iii) the spatial distribution of spin probe ions that surround polyions in solution. Analysis of CW EPR spectra of dianion nitroxide spin probe Fremys salt (FS, potassium nitrosodisulfonate) in solutions of cationic PDADMAC polyelectrolyte revealed that FS ions and PDADMAC form transient ion pairs with a lifetime of less than 1 ns. This effect was termed as dynamic electrostatic attachment (DEA). By spectral simulation taking into account the rotational dynamics as a uniaxial Brownian reorientation, also the geometry of the attached state could be characterized. By variation of solvent, the effect of solvent viscosity and permittivity were investigated and indirect information of the polyelectrolyte chain motion was obtained. Furthermore, analysis of CW EPR data also indicates that in mixtures of organic solvent/water PDADMAC chains are preferentially solvated by the organic solvent molecules, while in purely aqueous mixtures the PDADMAC chain segments were found in different conformations depending on the concentration ratio R of FS counterions to PDADMAC repeat units.Broadenings in CW EPR spectra of FS ions were assigned to spin-exchange interaction and hence contain information on the local concentrations and distributions of the counterions. From analysis of these broadenings in terms of a modified cylindrical cell approach of polyelectrolyte theory, radial distribution functions for the FS ions in the different solvents were obtained. This approach breaks down in water above a threshold value of R, which again indicates that PDADMAC chain conformations are altered as a function of R. Double electron-electron resonance (DEER) measurements of FS ions were carried out to probe the distribution of attached counterions along polyelectrolyte chains. For a significant fraction of FS spin probes in solution with a rigid-rod model polyelectrolyte containing charged Ru2+-centers, a bimodal distance distribution was found that nicely reproduced the spacings of direct and next-neighbor Ru2+-centers along the polyelectrolyte: 2.35 and 4.7 nm. For the system of FS/PDADMAC, DEER data could be simulated by assuming a two-state distribution of spin probes, one state corresponding to a homogeneous (3-dimensional) distribution of spin probes in the polyelectrolyte bulk and the other to a linear (1-dimensional) distribution of spin probes that are electrostatically condensed along locally extended PDADMAC chain segments. From this analysis it is suggested that the PDADMAC chains form locally elongated structures of a size of at least ~5 nm.
Resumo:
Nanotechnologies are rapidly expanding because of the opportunities that the new materials offer in many areas such as the manufacturing industry, food production, processing and preservation, and in the pharmaceutical and cosmetic industry. Size distribution of the nanoparticles determines their properties and is a fundamental parameter that needs to be monitored from the small-scale synthesis up to the bulk production and quality control of nanotech products on the market. A consequence of the increasing number of applications of nanomaterial is that the EU regulatory authorities are introducing the obligation for companies that make use of nanomaterials to acquire analytical platforms for the assessment of the size parameters of the nanomaterials. In this work, Asymmetrical Flow Field-Flow Fractionation (AF4) and Hollow Fiber F4 (HF5), hyphenated with Multiangle Light Scattering (MALS) are presented as tools for a deep functional characterization of nanoparticles. In particular, it is demonstrated the applicability of AF4-MALS for the characterization of liposomes in a wide series of mediums. Afterwards the technique is used to explore the functional features of a liposomal drug vector in terms of its biological and physical interaction with blood serum components: a comprehensive approach to understand the behavior of lipid vesicles in terms of drug release and fusion/interaction with other biological species is described, together with weaknesses and strength of the method. Afterwards the size characterization, size stability, and conjugation of azidothymidine drug molecules with a new generation of metastable drug vectors, the Metal Organic Frameworks, is discussed. Lastly, it is shown the applicability of HF5-ICP-MS for the rapid screening of samples of relevant nanorisk: rather than a deep and comprehensive characterization it this time shown a quick and smart methodology that within few steps provides qualitative information on the content of metallic nanoparticles in tattoo ink samples.
Resumo:
Iron deficiency is the most common deficiency disease worldwide with many patients who require intravenous iron. Within the last years new kind of parenteral iron complexes as well as generic preparations entered the market. There is a high demand for methods clarifying benefit to risk profiles of old and new iron complexes. It is also necessary to disclose interchangeability between originator and intended copies to avoid severe anaphylactic and anaphylactoid side reaction and assure equivalence of therapeutic effect.rnrnThe investigations presented in this work include physicochemical characterization of nine different parenteral iron containing non-biological complex drugs. rnWe developed an in-vitro assay, which allows the quantification of labile iron in the different complexes and thus it is a useful tool to estimate the pharmaclogical safety regarding iron related adverse drug events. This assay additionally allowed the estimation of complex stability by evaluation of degradation kinetics at the applied conditions.rnrnAn in-ovo study was performed to additionally compare different complexes in respect to body distribution. This in combination with complex stability information allowed the risk estimation of potential local acute and chronic reactions to iron overload.rnrnInformation obtained by the combination of the methods within this work are helpful to estimate the safety and efficacy profile of different iron containing non-biological complex drugs. rnrnPhysicochemical differences between the complexes were demonstrated in respect to size of the inorganic fraction, size and size distribution of the complete particles, structure of the inorganic iron fraction, morphology of the complexes and charge of the complexes. And furthermore significant differences in the biological behavior of different complexes were demonstrated. rnrnThe combination of complex stability and biodistribution as well as the combination of structure, size and stability represent helpful tools for the physicochemical characterization of iron containing non-biological complex drugs and for the estimation of pharmacological safety. This work thus represents an up to date summary of some relevant methods for the characterization of intravenous iron complex drugs in respect to pharmaceutical quality, pharmacological safety and aspects of efficacy. rnrnProspectively, it is worthwhile that the methods within this work will contribute to the development and/or characterization of iron containing nanoparticular formulations with beneficial efficacy and safety profiles.rn
Resumo:
Die Mikrophysik in Wolken bestimmt deren Strahlungseigenschaften und beeinflusst somit auch den Strahlungshaushalt des Planeten Erde. Aus diesem Grund werden im Rahmen der vorliegenden Arbeit die mikrophysikalischen Charakteristika von Cirrus-Wolken sowie von arktischen Grenzschicht-Wolken behandelt. Die Untersuchung dieser Wolken wurde mithilfe verschiedener Instrumente verwirklicht, welche Partikel in einem Durchmesserbereich von 250nm bis zu 6.4mm vermessen und an Forschungsflugzeugen montiert werden. Ein Instrumentenvergleich bestätigt, dass innerhalb der Bereiche in denen sich die Messungen dieser Instrumente überlappen, die auftretenden Diskrepanzen als sehr gering einzustufen sind. Das vorrangig verwendete Instrument trägt die Bezeichnung CCP (Cloud Combination Probe) und ist eine Kombination aus einem Instrument, das Wolkenpartikel anhand von vorwärts-gerichtetem Streulicht detektiert und einem weiteren, das zweidimensionale Schattenbilder einzelner Wolkenpartikel aufzeichnet. Die Untersuchung von Cirrus-Wolken erfolgt mittels Daten der AIRTOSS-ICE (AIRcraft TOwed Sensor Shuttle - Inhomogeneous Cirrus Experiment) Kampagne, welche im Jahr 2013 über der deutschen Nord- und Ostsee stattfand. Parameter wie Partikeldurchmesser, Partikelanzahlkonzentration, Partikelform, Eiswassergehalt, Wolkenhöhe und Wolkendicke der detektierten Cirrus-Wolken werden bestimmt und im Kontext des aktuellen Wissenstandes diskutiert. Des Weiteren wird eine beprobte Cirrus-Wolke im Detail analysiert, welche den typischen Entwicklungsprozess und die vertikale Struktur dieser Wolkengattung widerspiegelt. Arktische Grenzschicht-Wolken werden anhand von Daten untersucht, die während der VERDI (VERtical Distribution of Ice in Arctic Clouds) Kampagne im Jahr 2012 über der kanadischen Beaufortsee aufgezeichnet wurden. Diese Messkampagne fand im Frühling statt, um die Entwicklung von Eis-Wolken über Mischphasen-Wolken bis hin zu Flüssigwasser-Wolken zu beobachten. Unter bestimmten atmosphärischen Bedingungen tritt innerhalb von Mischphasen-Wolken der sogenannte Wegener-Bergeron-Findeisen Prozess auf, bei dem Flüssigwassertropfen zugunsten von Eispartikeln verdampfen. Es wird bestätigt, dass dieser Prozess anhand von mikrophysikalischen Messungen, insbesondere den daraus resultierenden Größenverteilungen, nachweisbar ist. Darüber hinaus wird eine arktische Flüssigwasser-Wolke im Detail untersucht, welche im Inneren das Auftreten von monomodalen Tröpfchen-Größenverteilungen zeigt. Mit zunehmender Höhe wachsen die Tropfen an und die Maxima der Größenverteilungen verschieben sich hin zu größeren Durchmessern. Dahingegen findet im oberen Übergangsbereich dieser Flüssigwasser-Wolke, zwischen Wolke und freier Atmosphäre, ein Wechsel von monomodalen zu bimodalen Tröpfchen-Größenverteilungen statt. Diese weisen eine Mode 1 mit einem Tropfendurchmesser von 20μm und eine Mode 2 mit einem Tropfendurchmesser von 10μm auf. Das dieses Phänomen eventuell typisch für arktische Flüssigwasser-Wolken ist, zeigen an dem Datensatz durchgeführte Analysen. Mögliche Entstehungsprozesse der zweiten Mode können durch Kondensation von Wasserdampf auf eingetragenen Aerosolpartikeln, die aus einer Luftschicht oberhalb der Wolke stammen oder durch Wirbel, welche trockene Luftmassen in die Wolke induzieren und Verdampfungsprozesse von Wolkentröpfchen hervorrufen, erklärt werden. Unter Verwendung einer direkten numerischen Simulation wird gezeigt, dass die Einmischung von trockenen Luftmassen in den Übergangsbereich der Wolke am wahrscheinlichsten die Ausbildung von Mode 2 verursacht.