951 resultados para Water Quality Guidelines
Resumo:
In some regions of Brazil, especially where the water is scarce, drinking water is stored in water storage tanks. This practice gives the consumer the guarantee of available water. The water storage conditions such as the exposure to hot weather when the tanks are on rooftops allow the development of microorganisms and microbial biofilms which can deteriorate the water quality and increase the risk to human health [1,2]. This study describes the filamentous fungi (FF) detected in free water and biofilms in drinking water storage tanks in Recife - Pernambuco, Brazil. Five sampling times in triplicate were performed at two distinct points. Colony-forming units (CFU) of FF fungi were determined with 0.45 µm filtration membranes using peptone glucose rose Bengal agar (PGRBA). From the 30 samples analysed a total of 1136 CFU were obtained. The water biofilms were collected from samplers consisting of polyethylene coupons, previously installed in the reservoirs. These coupons were transferred to PGRBA plates and incubated using with the same conditions described for free FF. For the in situ detection of FF in biofilms the Calcofluor White staining technique was used. This procedure demonstrated FF forming biofilms on the surfaces of the coupons. Brazilian legislation does not define limits for FF in drinking water. However considering the potential risk of fungal contamination, the data obtained in this study will contribute to developing future quantitative and qualitative parameters for the presence of fungi in drinking water distribution systems in Brazil. [1] HageskaL, G, Lima, N, Skaar, I. The study of fungi in drinking water. Mycological Research, 113, 2009, 165-172. [2] Skaar I, Hageskal G. Fungi in Drinking Water. In.: Paterson RRM, Lima N. (Eds.) Molecular Biology of Food and Water Borne Mycotoxigenic and Mycotic Fungi. CRC Press, Taylor & Francis Group, Boca Raton, 2015, 597-606.
Resumo:
High levels of marine salt deposition present in coastal areas have a relevant effect on road runoff characteristics. This study assesses this effect with the purpose of identifying the relationships between monitored water quality parameters and intrinsic site variables. To achieve this objective, an extensive monitoring program was conducted on a Portuguese coastal highway. The study included 30 rainfall events, in different weather, traffic, and salt deposition conditions. The evaluations of various water quality parameters were carried out in over 200 samples. In addition, the meteorological, hydrological, and traffic parameters were continuously measured. The salt deposition rates were determined by means of a wet candle device, which is an innovative feature of the monitoring program. The relation between road runoff pollutants and independent variables associated with weather, traffic, and salt deposition conditions was assessed. Significant correlations among pollutants were observed. A high salinity concentration and its influence on the road runoff were confirmed. Furthermore, the concentrations of the most relevant pollutants seemed to be very dependent on some meteorological variables, particularly the duration of the antecedent dry period prior to each rainfall event and the average wind speed.
Resumo:
In some regions of Brazil, especially where the water is scarce, drinking water is stored in water storage tanks. This practice gives the consumer the guarantee of available water. The water storage conditions such as the exposure to hot weather when the tanks are on rooftops allow the development of microorganisms and microbial biofilms which can deteriorate the water quality and increase the risk to human health [1,2]. This study describes the filamentous fungi (FF) detected in free water and biofilms in drinking water storage tanks in Recife - Pernambuco, Brazil. Five sampling times in triplicate were performed at two distinct points. Colony-forming units (CFU) of FF fungi were determined with 0.45 μm filtration membranes using peptone glucose rose Bengal agar (PGRBA). From the 30 samples analysed a total of 1136 CFU were obtained. The water biofilms were collected from samplers consisting of polyethylene coupons, previously installed in the reservoirs. These coupons were transferred to PGRBA plates and incubated using with the same conditions described for free FF. For the in situ detection of FF in biofilms the Calcofluor White staining technique was used. This procedure demonstrated FF forming biofilms on the surfaces of the coupons. Brazilian legislation does not define limits for FF in drinking water. However considering the potential risk of fungal contamination, the data obtained in this study will contribute to developing future quantitative and qualitative parameters for the presence of fungi in drinking water distribution systems in Brazil.
Resumo:
This paper examines the results of spatial (microgeographical) water contact/schistosomiasis studies in two African (Egyptian and Kenyan) and one Brazilian communities. All three studies used traditional cartographic and statistical methods but one of them emploeyd also GIS (geographical information systems) tools. The advantage of GIS and their potential role in schistosomiasis control are briefly described. The three cases revealed considerable variation in the spatial distribution of water contact, transmission parameters and infection levels at the household and individual levels. All studies showed considerable variation in the prevalence and intensity of infection between households. They also show a variable influence of distance on water contact behavior associated with type of activity, age, sex, socioeconomic level, perception of water quality, season and availability of water in the home. Water contact behavior and schistosomiasis were evaluated in the Brazilian village of Nova União within the context of water sharing between household and age/sex groups. Recommendations are made for further spatial studies on the transmission and control of schistosomiasis.
Resumo:
Human adenoviruses (HAdV) and hepatitis A virus (HAV) are shed in the faeces and consequently may be present in environmental waters, resulting in an increase in pathogen concentration that can affect water quality and human health. The aim of this study was to evaluate an adsorption-elution method which utilizes negatively charged membrane HA to determine the efficient recovery of HAdV and HAV from different water matrices and to combine this procedure with a qualitative molecular method (nested RT-PCR and nested PCR). The best efficiency recovery was achieved in distilled water and treated wastewater effluent (100%) for both viruses and in recreational lagoon water for HAV (100%). The efficiency recovery was 10% for HAdV and HAV in seawater and 10% for HAdV in lagoon water. The viral detection limit by nested PCR for HAV in water samples ranged between 20-0.2 FFU/mL and 250 and 25 TCID50/mL for HAdV. In conclusion, these results suggest that the HA negatively charged membranes vary their efficiency for recovery of viral concentration depending upon the types of both enteric viruses and water matrices.
Resumo:
During the second half of the nineteenth century a major mineral water bottling industry appeared in Catalonia which vigorously lasted until the first third of the 20th century. The fact that the industry appeared in Catalonia and in other parts of Europe and the United States almost at the same time and had not existed before can be explained by a series of factors which coincided in time. This situation encouraged producers to pack, transport and sell bottled water from their respective sources. Among these factors there is the rise of hygienism, very influential in Catalonia, the declining water quality due to industrialization, the increase in population density, the improvement in transport, the emergence of thermal tourism or the invention of better containers used to store water. This project aims to explain thoroughly all the mentioned factors, and to give some light to why, when and how the Catalan bottled water industry appeared.
Resumo:
The Iowa Department of Natural Resources has produced an 4 page article about how to assess Iowa's streams and rivers. How to use ambient monitoring of streams and river in Iowa.
Resumo:
The Iowa Department of Natural Resources has produced an 4 page article about how to assess Iowa's streams and rivers. How to use ambient monitoring of streams and river in Iowa.
Resumo:
A report on Iowa Water Monitoring produced by Iowa Department of Natural Resources.
Resumo:
Water fact sheet for Iowa Department of Natural Resources and the Geological Bureau.
Resumo:
This fact sheet answers questions such as, is it safe to swim in the water and who is monitoring the beaches in Iowa
Resumo:
This monthly report from the Iowa Department of Natural Resources is about the water quality management of Iowa's rivers, streams and lakes.
Resumo:
This monthly report from the Iowa Department of Natural Resources is about the water quality management of Iowa's rivers, streams and lakes.
Resumo:
This monthly report from the Iowa Department of Natural Resources is about the water quality management of Iowa's rivers, streams and lakes.