939 resultados para Ultrasonic inspections
Resumo:
Obtaining as much particulate material as possible from questioned items is desirable in forensic science as this allows a range of analyses to be undertaken and the retention of material for others to check. A method of maximising particulate recovery is described using a kidnap case, where minimal staining on clothing (socks) remained as possible indications of where the victim had been held captive. Police intelligence led to a hostage scene that was sampled. Brushing of the socks recovered about 50 sand grains with some silt: ultrasonic agitation and centrifuging recovered over 300 grains of sand, silt and clay. These were visually compared to scene and control samples, allowing exclusion of 52 samples and the retention of one comparison sample as well as other possibles, saving time and money, but maximising sample quantity and quality. © 2011 Elsevier Ireland Ltd.
Resumo:
The cure of polydicyclopentadiene conducted by ring-opening metathesis polymerisation in the presence of a Grubbs catalyst was studied using non-invasive Raman spectroscopy. The spectra of the monomer precursor and polymerised product were fully characterised and all stages of polymerisation monitored. Because of the monomer's high reactivity, the cure process is adaptable to reaction injection moulding and reactive rotational moulding. The viscosity of the dicyclopentadiene undergoes a rapid change at the beginning of the polymerisation process and it is critical that the induction time of the viscosity increase is determined and controlled for successful manufacturing. The results from this work show non-invasive Raman spectroscopic monitoring to be an effective method for monitoring the degree of cure, paving the way for possible implementation of the technique as a method of real-time analysis for control and optimisation during reactive processing. Agreement is shown between Raman measurements and ultrasonic time of flight data acquired during the initial induction period of the curing process. (c) 2004 Elsevier B.V. All rights reserved.
Resumo:
Decreasing the constriction size and residence time in hydrodynamic cavitation is predicted to give increased hot spot temperatures at bubble collapse and increased radical formation rate. Cavitation in a 100 x 100 mu m(2) rectangular micro channel and in a circular 750 mu m diameter milli channel has been investigated with computational fluid dynamics software and with imaging and radical production experiments. No radical production has been measured in the micro channel. This is probably because there is no spherically symmetrical collapse of the gas pockets in the channel which yield high hot spot temperatures. The potassium iodide oxidation yield in the presence of chlorohydrocarbons in the milli channel of up to 60 nM min(-1) is comparable to values reported on hydrodynamic cavitation in literature, but lower than values for ultrasonic cavitation. These small constrictions can create high apparent cavitation collapse frequencies.
Resumo:
The initial rate of oxidation of octan-2-ol and other secondary alcohols to their ketones with NaBrO3, mediated by RuO4 in an aqueous-CCl4 biphasic system, is greater with ultrasonic irradiation than by stirring alone. Under ultrasonic irradiation the initial rate of oxidation of octan-2-ol increases with increasing % duty cycle, [RuO4] and [NaBrO3]. The kinetics of alcohol oxidation appear to be closely linked with the oxidative dissolution of RuO2 to RuO4 by NaBrO3. The observed enhancement in rate with ultrasonic irradiation appear to be association, at least in part, with the increase in interfacial surface area via the formation of an emulsion of aqueous microdroplets containing NaBrO3 in the CCl4 layer containing the non-water-soluble secondary alcohol.
Resumo:
Ultrasound promotes the reduction of hexacyanoferrate(III) by thiosulfate ions mediated by RuO2 . xH(2)O under diffusion-controlled conditions. There is a strong correlation between the measured first-order rate constant and the absorbance of the dispersion, which, in turn, is closely related to the specific surface area of the catalyst. The enhancement in rate with ultrasonic irradiation appears to be largely associated with the dispersive action of the ultrasound on the aggregated particles of RuO2 . xH(2)O. The rate of reaction increases with increasing %duty cycle and ultrasonic intensity. The measured overall activation energies for the reaction with and without ultrasound, i.e. 18 +/- 1 and 20 +/- 1 kJ mol(-1), respectively, are very similar to those expected for a diffusion-controlled reaction. The homogeneous reaction is not promoted by ultrasound.
Resumo:
The cidal activities of aqueous taurolidine (2.0% w/v containing 5.0% wlv polyvinylpyrrolidone as a solubilising agent) and alcoholic taurolidine (2.0% w/v dissolved in Isopropyl alcohol 50% v/v) against spores of Bacillus subtilis NCTC 10073 were evaluated at 20 degrees C, 37 degrees C, 45 degrees C and 55 degrees C. Increased temperature increased both the rate and extent of sporicidal activity of both solutions. Total spore kill was not observed in either solution type over the range of temperatures and contact times examined. There were no observed differences between the sporicidal activities of aqueous and alcoholic taurolidine solutions at all temperatures examined. Ultrasonic energy (50 Hz operating frequency in a 150 W ultrasonic bath in conjunction with increasing temperature allowed to rise naturally from ambient temperature to 41 degrees C over 4 h) enhanced the sporicidal activities of both solution types. However, the difference in activity between the two solution types was not significant. Compared to normal spores, alteration of spore coat layers (hydrogen-form spores) did not alter spore susceptibility to aqueous taurolidine at elevated temperatures of 37 degrees C and 55 degrees C.
Resumo:
DDR-SDRAM based data lookup techniques are evolving into a core technology for packet lookup applications for data network, benefitting from the features of high density, high bandwidth and low price of DDR memory products in the market. Our proposed DDR-SDRAM based lookup circuit is capable of achieving IP header lookup for network line-rates of up to 10Gbps, providing a solution on high-performance and economic packet header inspections. ©2008 IEEE.
Resumo:
The haemagglutinating and enzymic activities of the obligately anaerobic pathogenic bacterium Bacteroides fragilis were examined. Outer membrane vesicles are released from the surface of B. fragilis. They can be detected by electron microscopy in ultrathin sections and bacterial suspensions after negative staining. Electron microscopy and immunogold labelling with a MAb specific for surface polysaccharide of B. fragilis confirmed that the vesicles carried outer membrane associated epitopes. The haemagglutinating activity of whole cells from populations of B. fragilis strains NCTC9343, BE3 and LS66 enriched by Percoll density gradient centrifugation for a large capsule (LC), electron dense layer (EDL); non-capsulate by light microscopy) and outer membrane vesicles (OMV) which had been purified by centrifugation from EDL-enriched populations were compared using human and horse erythrocytes. The enzymic activity of OMV, LC- and EDL-enriched populations, as detected by the API ZYM kit, was compared for strains NCTC 9343 and BE3. Purified OMV from the strains examined exhibited both haemagglutinating and enzymatic activity. Haemagglutination by the EDL-enriched population was sensitive to treatment with sodium periodate. The LC-enriched population haemagglutinated only after ultrasonic removal of the capsule. This indicates that the LC masks a haemagglutinin. The results suggest a potential role for OMV in the virulence of B. fragilis.
Resumo:
We develop a theoretical model of enforcement and compliance under HACCP regulation and use the FDA's seafood inspection records to examine: (1) if the FDA has targeted its inspections under HACCP regulation; (2) the effects of inspections on compliance with HACCP and plant sanitation standards; and (3) the relationship between compliance with HACCP and preexisting sanitation standards. There is some evidence of targeting based on product risk, but not on past compliance performance. The threat of an inspection increases the likelihood of compliance, but only for sanitation inspections, not for HACCP. HACCP compliance does not improve compliance with sanitation standards. © 2008 American Agricultural Economics Association.
Resumo:
PURPOSE: To assess the correlation between central corneal thickness (CCT) and anterior scleral thickness (ST) in patients of primary open-angle glaucoma (POAG), normal tension glaucoma (NTG), and ocular hypertension (OHT). PATIENTS AND METHODS: Consecutive patients with OHT, POAG, NTG, and normal individuals were recruited. CCT was measured by ultrasonic pachymetry, whereas ST was measured using ultrasonic biomicroscopy at the temporal quadrant, 2'mm posterior to the scleral spur. Investigators were masked to the diagnosis and CCT/ ultrasonic biomicroscopy data. Correlation between mean CCT and ST was analyzed. RESULTS: One hundred and twenty-four subjects (31 with OHT, 31 with POAG, 31 with NTG, and 31 normal individuals) were enrolled. The CCT (OHT 548.06±30.45'µm; POAG 519.39±42.95'µm; NTG 505.81±27.23'µm; controls 529.90±43.40'µm) was found to be thicker in patients with OHT than POAG (P=0.004) or NTG (P
Resumo:
Experiments were undertaken to determine if nitric oxide (NO) plays a role in regulation of basal blood flow in the oral cavity of pentobarbital anesthetized cats and, if so, to quantify this effect using dose-response relationships. Blood flow was continuously measured from the surface of the tongue and mandibular gingiva (laser-Doppler flowmetry) and from the lingual artery (ultrasonic flowmetry). Cardiovascular parameters also were recorded. Administration of the nonselective inhibitor of nitric oxide synthase (NOS), L-NAME (0.08-20 mg/kg i.v.), produced a dose-related increase of blood pressure associated with decreases of blood flow at all three measurement sites. Maximal blood flow depression of 50-60% was seen 30-60 min after administration of 1.25 mg/kg of L-NAME. D-NAME (1.25 mg/kg i.v.) was inactive at all sites. Subsequent administration of L-arginine partially reversed effects of L-NAME in the lingual artery and tongue, but not in the gingival circulation. The neuronally selective NOS inhibitor, 7-nitroindazole (7-NI, 30 mg/kg i.p.), was devoid of effect on any of the measured parameters. These results suggest that endothelial (but not neuronally derived) NO plays an important role in control of basal blood flow in oral tissues of the cat.
Resumo:
The cooling process in conventional rotomolding is relatively long due to poor thermal conductivity of plastics. The lack of internal cooling is a major limitation although rapid external cooling is possible. Various internal cooling methodologies have been studied to reduce the cycle time. These include the use of compressed air, cryogenic liquid nitrogen, chilled water coils, and cryogenic liquid carbon dioxide, all of which have limitations. However, this article demonstrates the use of water spray cooling of polymers as a viable and effective method for internal cooling in rotomolding. To this end, hydraulic, pneumatic, and ultrasonic nozzles were applied and evaluated using a specially constructed test rig to assess their efficiency. The effects of nozzle type and different parametric settings on water droplet size, velocity, and mass flow rate were analyzed and their influence on cooling rate, surface quality, and morphology of polymer exposed to spray cooling were characterized. The pneumatic nozzle provided highest average cooling rate while the hydraulic nozzle gave lowest average cooling rate. The ultrasonic nozzle with medium droplet size traveling at low velocity produced satisfactory surface finish. Water spray cooling produced smaller spherulites compared to ambient cooling whilst increasing the cooling rate decreases the percentage crystallinity. © 2011 Society of Plastics Engineers Copyright © 2011 Society of Plastics Engineers.
Resumo:
This study investigates potential causes of a novel blister-like syndrome in the plating coral Echinopora lamellosa. Visual inspections of this novel coral syndrome showed no obvious signs of macroparasites and the blisters themselves manifested as fluid-filled sacs on the surface of the coral, which rose from the coenosarc between the coral polyps. Histological analysis of the blisters showed that there was no associated necrosis with the epidermal or gastrodermal tissues. The only difference between blistered areas and apparently healthy tissues was the presence of proliferated growth (possible mucosal cell hyperplasia) directly at the blister interface (area between where the edge of the blister joined apparently healthy tissue). No bacterial aggregates were identified in any histological samples, nor any sign of tissue necrosis identified. We conclude, that the blister formations are not apparently caused by a specific microbial infection, but instead may be the result of irritation following growth anomalies of the epidermis. However, future work should be conducted to search for other potential casual agents, including viruses. © 2014 Smith et al.
Resumo:
This paper brings together and analyzes recent work based on the interpretation of the electrochemical measurements made on a modified micro-abrasion-corrosion tester used in several research programmes. These programmes investigated the role of abradant size, test solution pH in abrasion-corrosion of biomaterials, the abrasion-corrosion performance of sintered and thermally sprayed tungsten carbide surfaces under downhole drilling environments and the abrasion-corrosion of UNS S32205 duplex stainless steel. Various abrasion tests were conducted under two-body grooving, three-body rolling and mixed grooving-rolling abrasion conditions, with and without abrasives, on cast F75 cobalt-chromium-molybdenum (CoCrMo) alloy in simulated body fluids, 2205 in chloride containing solutions as well as sprayed and sintered tungsten carbide surfaces in simulated downhole fluids. Pre- and post-test inspections based on optical and scanning electron microscopy analysis are used to help interpret the electrochemical response and current noise measurements made in situ during micro-abrasion-corrosion tests. The complex wear and corrosion mechanisms and their dependence on the microstructure and surface composition as a function of the pH, abrasive concentration, size and type are detailed and linked to the electrochemical signals. The electrochemical versus mechanical processes are plotted for different test parameters and this new approach is used to interpret tribo-corrosion test data to give greater insights into different tribo-corrosion systems. Thus new approaches to interpreting in-situ electrochemical responses to surfaces under different abrasive wear rates, different abrasives and liquid environments (pH and NaCl levels) are made. This representation is directly related to the mechano-electrochemical processes on the surface and avoids quantification of numerous synergistic, antagonistic and additive terms associated with repeat experiments. (C) 2010 Elsevier Ltd. All rights reserved.
Resumo:
Melt viscosity is one of the main factors affecting product quality in extrusion processes particularly with regard to recycled polymers. However, due to wide variability in the physical properties of recycled feedstock, it is difficult to maintain the melt viscosity during extrusion of polymer blends and obtain good quality product without generating scrap. This research investigates the application of ultrasound and temperature control in an automatic extruder controller, which has ability to maintain constant melt viscosity from variable recycled polymer feedstock during extrusion processing. An ultrasonic modulation system has been developed and fitted to the extruder prior to the die to convey ultrasonic energy from a high power ultrasonic generator to the polymer melt. Two separate control loops have been developed to run simultaneously in one controller: the first loop controls the ultrasonic energy or temperature to maintain constant die pressure, the second loop is used to control extruder screw speed to maintain constant throughput at the extruder die. Time response and energy consumption of the control methods in real-time experiments are also investigated and reported this paper.