963 resultados para Sensitivity and Specificity
Resumo:
Active surveillance for dengue (DEN) virus infected mosquitoes can be an effective way to predict the risk of dengue infection in a given area. However, doing so may pose logistical problems if mosquitoes must be kept alive or frozen fresh to detect DEN virus. In an attempt to simplify mosquito processing, we evaluated the usefulness of a sticky lure and a seminested reverse-transcriptase polymerase chain reaction assay (RT-PCR) for detecting DEN virus RNA under laboratory conditions using experimentally infected Aedes aegypti (L.) mosquitoes. In the first experiment, 40 male mosquitoes were inoculated with 0.13 mul of a 10(4) pfu/ml DEN-2 stock solution. After a 7-d incubation period, the mosquitoes were applied to the sticky lure and kept at room temperatures of 23-30 degreesC. Following 7,10,14, and 28 d application, 10 mosquitoes each were removed from the lure pooled and assayed for virus. DEN virus nucleic acid was clearly detectable in all pools up to 28 d after death. A second study evaluated sensitivity and specificity using one, two, and five DEN-infected mosquitoes removed after 7, 10, 14, 21 and 30 d application and tested by RT-PCR. All four DEN serotypes were individually inoculated in mosquitoes and evaluated using the same procedures as experiment 1. The four serotypes were detectable in as few as one mosquito 30 d after application to the lure with no evidence of cross-reactivity. The combination of sticky lures and RT-PCR show promise for mosquito and dengue virus surveillance and warrant further evaluation.
Resumo:
Quantification of stress echocardiography may overcome the training requirements and subjective nature of visual wall motion score (WMS) assessment, but quantitative approaches may be difficult to apply and require significant time for image processing. The integral of long-axis myocardial velocity is displacement, which may be represented as a color map over the left ventricular myocardium. This study was designed to explore the feasibility and accuracy of measuring long-axis myocardial displacement, derived from tissue Doppler, for the detection of coronary artery disease (CAD) during dobutamine stress echocardiography (DBE). One hundred thirty patients underwent standard DBE, including 30 patients at low risk of CAD, 30 patients with normal coronary angiography (both groups studied to define normal ranges of displacement), and 70 patients who underwent coronary angiography in whom the accuracy of normal ranges was tested. Regional myocardial displacement was obtained by analysis of color tissue Doppler apical images acquired at peak stress. Displacement was compared with WMS, and with the presence of CAD by angiography. The analysis time was 3.2 +/- 1.5 minutes per patient. Segmental displacement was correlated with wall motion (normal 7.4 +/- 3.2 mm, ischemia 5.8 +/- 4.2 mm, viability 4.6 +/- 3.0 mm, scar 4.5 +/- 3.5 mm, p <0.001). Reversal of normal base-apex displacement was an insensitive (19%) but specific (90%) marker of CAD. The sum of displacements within each vascular territory had a sensitivity and specificity of 89% and 79%, respectively, for prediction of significant CAD, compared with 86% and 78%, respectively, for WMS (p = NS). The displacements in the basal segments had a sensitivity and specificity of 83% and 78%, respectively (p = NS). Regional myocardial displacement during DBE is feasible and offers a fast and accurate method for the diagnosis of CAD. (C),2002 by Excerpta Medica, Inc.
Resumo:
Indicators are valuable tools used to measure progress towards a desired health outcome. Increased awareness of the public health burden due to injury has lead to a concomitant interest in monitoring the impact of national initiatives that aim to reduce the size of the burden. Several injury indicators have now been proposed. This study examines the ability of each of the suggested indicators to reflect the nature and extent of the burden of non-fatal injury. A criterion validity, population-based, prospective cohort study was conducted in Brisbane, a sub-tropical Metropolitan City on the eastern seaboard of Australia, over a 12-month period between 1 January and 31 December 1998. Neither the presence of a long bone fracture nor the need for hospitalisation for 4 or more days were sensitive or specific indicators for 'serious' or major injury as defined by the 'Gold Standard' Injury Severity Score (ISS). Subsequent analysis, using other public health outcome measures demonstrated that the major component of the illness burden of injury was in fact due to 'minor' not serious injury. However, the suggested indicators demonstrated low sensitivity and specificity for these outcomes as well. The results of the study support the need to include at least all hospitalisations in any population-based measure of injury and not attempt to simplify the indicator to a more convenient measure aimed at identifying just those cases of,serious' injury.
Resumo:
Using the Roche LightCycler we developed a real-time reverse transcriptase polymerase chain reaction (RT-PCR) assay using the Influenza A LightCycler RT-PCR (FA-LC-RTPCR) for the rapid detection of Influenza A. The assay was used to examine 178 nasopharyngeal aspirate (NPA) samples, from patients with clinically recognised respiratory tract infection, for the presence of Influenza A RNA. The results were then compared to a testing algorithm combining direct immunofluorescent assy (DFA) and a culture augmented DFA (CA-DFA) assay. In total, 76 (43%) specimens were positive and 98 (55%) specimens were negative by both the FA-LC-RTPCR and the DFA and CA-DFA algorithm. In addition, the FA-LC-RTPCR detected a further 4 (2%) positive specimens, which were confirmed by a conventional RT-PCR method. The high level of sensitivity and specificity, combined with the rapid turnaround time for results, makes the LC-RT-PCR assay suitable for the detection of Influenza A in clinical specimens.
Resumo:
The aging of Portuguese population is characterized by an increase of individuals aged older than 65 years. Preventable visual loss in older persons is an important public health problem. Tests used for vision screening should have a high degree of diagnostic validity confirmed by means of clinical trials. The primary aim of a screening program is the early detection of visual diseases. Between 20% and 50% of older people in the UK have undetected reduced vision and in most cases is correctable. Elderly patients do not receive a systematic eye examination unless a problem arises with their glasses or suspicion vision loss. This study aimed to determine and evaluate the diagnostic accuracy of visual screening tests for detecting vision loss in elderly. Furthermore, it pretends to define the ability to find the subjects affected with vision loss as positive and the subjects not affected with the same disease as negative. The ideal vision screening method should have high sensitivity and specificity for early detection of risk factors. It should be also low cost and easy to implement in all geographic and socioeconomic regions. Sensitivity is the ability of an examination to identify the presence of a given disease and specificity is the ability of the examination to identify the absence of a given disease. It was not an aim of this study to detect abnormalities that affect visual acuity. The aim of this study was to find out what´s the best test for the identification of any vision loss.
Resumo:
O cancro da mama e o cancro colorretal constituem duas das principais causas de morte a nível mundial. Entre 5 a 10% destes casos estão associados a variantes germinais/hereditárias em genes de suscetibilidade para cancro. O objetivo deste trabalho consistiu em validar a utilização da sequenciação de nova geração (NGS) para identificar variantes previamente detetadas pelo método de Sanger em diversos genes de suscetibilidade para cancro da mama e colorretal. Foram sequenciadas por NGS 64 amostras de DNA de utentes com suspeita clínica de predisposição hereditária para cancro da mama ou colorretal, utilizando o painel de sequenciação TruSight Cancer e a plataforma MiSeq (Illumina). Estas amostras tinham sido previamente sequenciadas pelo método de Sanger para os genes BRCA1, BRCA2, TP53, APC, MUTYH, MLH1, MSH2 e STK11. A análise bioinformática dos resultados foi realizada com os softwares MiSeq Reporter, VariantStudio, Isaac Enrichment (Illumina) e Integrative Genomics Viewer (Broad Institute). A NGS demonstrou elevada sensibilidade e especificidade analíticas para a deteção de variantes de sequência em 8 genes de suscetibilidade para cancro colorretal e da mama, uma vez que permitiu identificar a totalidade das 412 variantes (93 únicas, incluindo 27 variantes patogénicas) previamente detetadas pelo método de Sanger. A utilização de painéis de sequenciação de genes de predisposição para cancro por NGS vem possibilitar um diagnóstico molecular mais abrangente, rápido e custo-eficiente, relativamente às metodologias convencionais.
Resumo:
OBJECTIVE: To assess the usefulness of corneal esthesiometry for screening diabetic retinopathy. METHODS: A cross-sectional study was carried out comprising 575 patients attending a diabetic retinopathy-screening program in the city of São Paulo. Corneal esthesiometry was assessed with the Cochet-Bonnet esthesiometer. The presence of diabetic retinopathy was detected with indirect fundoscopy. The validity of corneal esthesiometry in identifying diabetic retinopathy was evaluated by the Receiver Operating Characteristic (ROC) curve. RESULTS: Sensitivity and specificity analyses of the corneal esthesiometry for detecting the stages of diabetic retinopathy using different cut-offs showed values less than 80%. The best indices (72.2% sensitivity and 57.4% specificity) were obtained for the identification of patients with proliferative diabetic retinopathy. CONCLUSIONS: In the study series, corneal esthesiometry was not a good indicator of diabetic retinopathy.
Resumo:
OBJECTIVE: To comparatively detect A. actinomycetemcomitans and F. nucleatum from periodontal and healthy sites. METHODS: Subgingival clinical samples from 50 periodontitis adult patients and 50 healthy subjects were analyzed. Both organisms were isolated using a trypticase soy agar-bacitracin-vancomycin (TSBV) medium and detected by PCR. Conventional biochemical tests were used for bacteria identification. RESULTS: A. actinomycetemcomitans and F. nucleatum were isolated in 18% and 20% of the patients, respectively, and in 2% and 24% of healthy subjects. Among A. actinomycetemcomitans isolates, biotype II was the most prevalent. Primer pair AA was 100% sensitive in the detection of A. actinomycetemcomitans from both subject groups. Primers ASH and FU were also 100% sensitive to detect this organism in healthy subject samples. Primer pair FN5047 was more sensitive to detect F. nucleatum in patients or in healthy samples than primer 5059S. Primers ASH and 5059S were more specific in the detection of A. actinomycetemcomitans and F. nucleatum, respectively, in patients and in healthy subject samples. CONCLUSIONS: PCR is an effective tool for detecting periodontal pathogens in subgingival samples, providing a faster and safer diagnostic tool of periodontal diseases. The method's sensitivity and specificity is conditioned by the choice of the set of primers used.
Resumo:
RESUMO: Objetivos – Determinar a sensibilidade e especificidade das ponderações Difusão (DWI) e T2 Fluid-Attenuated Inversion Recovery (FLAIR) na avaliação de lesões da substância branca (SB) e verificar em que medida se complementam, por forma a criar um conjunto de boas práticas na RM cranioencefálica de rotina. Metodologia – Recorrendo-se a uma metodologia quantitativa, efetuou-se uma análise retrospetiva da qual foram selecionados 30 pacientes, 10 sem patologia e 20 com patologia (2 com EM, 7 com Leucoencefalopatia, 6 com doença microangiopática e 5 com patologia da substância branca indefinida). Obteve-se uma amostra de 60 imagens, nomeadamente: 30 imagens ponderadas em DWI e 30 em T2 FLAIR. Recorrendo ao programa Viewdex®, três observadores avaliaram um conjunto de imagens segundo sete critérios: visibilidade, deteção, homogeneidade, localização, margens e dimensões da lesão e capacidade de diagnóstico. Com os resultados obtidos recorreu-se ao cálculo de sensibilidade e especificidade pelas Curvas ROC, bem como à análise estatística, nomeadamente, Teste-T, Índice de Concordância Kappa e coeficiente de correlação de Pearson entre as variáveis em estudo. Resultados – Os resultados de sensibilidade e de especificidade obtidos para a ponderação T2 FLAIR foram superiores (0,915 e 0,038, respetivamente) aos da ponderação DWI (0,08 e 0,100, respetivamente). Não se verificaram variâncias populacionais significativas. Obteve-se uma elevada correlação linear entre as variáveis com um valor r situado entre 0,8 e 0,99. Verificou-se também uma variabilidade considerável entre os observadores. Conclusões – Dados os baixos valores de sensibilidade e especificidade obtidos para a DWI, sugere-se que esta deva ser incluída no protocolo de rotina de crânio como auxiliar no diagnóstico diferencial com outras patologias.
Resumo:
In this paper, we present the results of mammography quality control tests related to the work with Portuguese mammography equipment, either in conventional or in digital mammography computed radiography, showing the main differences in the tested equipments. Quality control in mammography is a very special area of quality control in radiology, which demands relatively high knowledge on physics. Digital imaging is changing the standards of the radiographic imaging. Regarding mammography, this is yet a controversial issue owing to some limitations of the digital detectors, like the resolution for instance. A complete set of results regarding radiation protection of the patients submitted to mammography diagnosis is presented. A discussion of the quality image parameters and its interpretation in conventional and digital mammography is presented. In conclusion, we present a sample of results that can be considered as characteristics of mammography equipment in Portugal.
Resumo:
Chronic Liver Disease is a progressive, most of the time asymptomatic, and potentially fatal disease. In this paper, a semi-automatic procedure to stage this disease is proposed based on ultrasound liver images, clinical and laboratorial data. In the core of the algorithm two classifiers are used: a k nearest neighbor and a Support Vector Machine, with different kernels. The classifiers were trained with the proposed multi-modal feature set and the results obtained were compared with the laboratorial and clinical feature set. The results showed that using ultrasound based features, in association with laboratorial and clinical features, improve the classification accuracy. The support vector machine, polynomial kernel, outperformed the others classifiers in every class studied. For the Normal class we achieved 100% accuracy, for the chronic hepatitis with cirrhosis 73.08%, for compensated cirrhosis 59.26% and for decompensated cirrhosis 91.67%.
Resumo:
A maximização do potencial da abordagem cirúrgica conservadora da axila para o cancro da mama, como um método minimamente invasivo para a avaliação de metastização axilar, visando diminuir a morbilidade associada ao esvaziamento axilar completo, requer um método preciso para avaliação patológica intraoperatória. Esse método não foi ainda estabelecido. Imprints e corte de congelação do gânglio sentinela são os procedimentos comummente utilizados, apesar de uma sensibilidade e especificidade inferior à desejada. Actualmente, novas técnicas estão a ser desenvolvidas, que apesar da sua optimização, ainda não ultrapassam os resultados das utilizadas. Um total de 138 mulheres com cancro da mama, submetidas a cirurgia mamária por abordagem conservadora da axila, cuja utilização de imprints e cortes de congelação foram os métodos de avaliação intraoperatória do gânglio sentinela. Os diagnósticos dados pela observação dos cortes dos fragmentos do exame extemporâneo foram comparados com os obtidos nos cortes histológicos definitivos dos fragmentos fixados em formol e incluídos em parafina. Os resultados obtidos da avaliação do exame extemporâneo demonstraram sensibilidade de 79,1%, especificidade de 96,9%, com uma precisão de 91,4%. Não se obteve correlação entre os resultados do extemporâneo e os parâmetros de caracterização do exame extemporâneo e tumores. Os métodos, imprints e cortes de congelação, actualmente utilizados na nossa instituição apresentam bons resultados, mas a adopção de apenas um ou outro necessita de uma análise mais aprofundada dos dados relativos à metodologia utilizada nos extemporâneos, de forma a verificar a especificidade e sensibilidade individualizadas dos imprints e dos cortes de congelação. Se os imprints se revelarem semelhantes aos cortes de congelação, a sua utilização é preferencial uma vez que acarreta menores custos e são menos morosos. A implementação de novas técnicas será uma metodologia adoptar, pelos benefícios acrescidos, porém mais estudos e a optimização
Resumo:
Mestrado em Gestão e Avaliação de Tecnologias em Saúde.
Resumo:
OBJECTIVE: To estimate the validity of three single questions used to assess self-reported hearing loss as compared to pure-tone audiometry in an adult population. METHODS: A validity study was performed with a random sub-sample of 188 subjects aged 30 to 65 years, drawn from the fourth wave of a population-based cohort study carried out in Salvador, Northeastern Brazil. Data were collected in household visits using questionnaires. Three questions were used to separately assess self-reported hearing loss: Q1, "Do you feel you have a hearing loss?"; Q2, "In general, would you say your hearing is 'excellent,' 'very good,' 'good,' 'fair,' 'poor'?"; Q3, "Currently, do you think you can hear 'the same as before', 'less than before only in the right ear', 'less than before only in the left ear', 'less than before in both ears'?". Measures of accuracy were estimated through seven measures including Youden index. Responses to each question were compared to the results of pure-tone audiometry to estimate accuracy measures. RESULTS: The estimated sensitivity and specificity were 79.6%, 77.4% for Q1; 66.9%, 85.1% for Q2; and 81.5%, 76.4% for Q3, respectively. The Youden index ranged from 51.9% (Q2) to 57.0% (Q1) and 57.9% (Q3). CONCLUSIONS: Each of all three questions provides responses accurate enough to support their use to assess self-reported hearing loss in epidemiological studies with adult populations when pure-tone audiometry is not feasible.
Resumo:
OBJECTIVE To assess the increased diagnostic yield for pulmonary tuberculosis using bronchial washing cultures compared with sputum cultures. METHODS Study conducted with 61 adults in Lima, Peru, from January 2006 to December 2007. The yield of sputum cultures was compared with the yield of acid-fast bacilli smears and cultures of bronchial washing for diagnosing pulmonary tuberculosis in suspected cases of clinical tuberculosis with negative acid fast bacilli sputum smears. RESULTS Twenty seven (95%CI 32;58) of the cases were eventually diagnosed with smear-negative pulmonary tuberculosis. Bronchial washing samples detected 23 (95%CI 72;99) of the smear-negative pulmonary tuberculosis cases compared with 15 (95%CI 37;74) for sputum cultures (p = 0.02). The incremental diagnostic yield of acid fast bacilli smear and culture of bronchial washing specimens over sputum culture was 44% (95%CI 25;65). CONCLUSIONS In function of the epidemiological context and the resources available, bronchoscopy should be deployed as part of a comprehensive work up that optimizes smear-negative pulmonary tuberculosis diagnosis and minimizes risk and costs.