997 resultados para Optical magnetic twisting cytometry


Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report the findings of abdominal ultrasound and magnetic resonance imaging observed in a patient with advanced schistosomiasis mansoni. A 25-year-old man with hepatosplenic schistosomiasis and variceal bleeding confirmed by upper endoscopy was submitted to abdominal ultrasound and magnetic resonance imaging. During surgery for portal hypertension, a liver biopsy was taken and the diagnosis of Symmers' fibrosis was confirmed. magnetic resonance imaging scans gave more precise information about the gallbladder, periportal thickening and abdominal venous system than did the ultrasound.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: There is no study relating magnetic resonance imaging (MRI) to ultrasound (US) findings in patients with Schistosomiasis mansoni. Our aim was to describe MRI findings inpatients with schistosomal liver disease identified by US. METHODS: Fifty-four patients (mean age 41.6±13.5years) from an area endemic for Schistosomiasis mansoni were selected for this study.All had US indicating liver schistosomal fibrosis and were evaluated with MRI performed witha 1.5-T superconducting magnet unit (Sigma). RESULTS: Forty-seven (87%) of the 54 patientsshowing signs of periportal fibrosis identified through US investigation had confirmed diagnosesby MRI. In the seven discordant cases (13%), MRI revealed fat tissue filling in the hilar periportalspace where US indicated isolated thickening around the main portal vein at its point of entryto the liver. We named this the fatty hilum sign. One of the 47 patients with MRI evidence ofperiportal fibrosis had had his gallbladder removed previously. Thirty-five (76.1%) of the other46 patients had an expanded gallbladder fossa filled with fat tissue, whereas MRI of the remainingeleven showed pericholecystic signs of fibrosis. CONCLUSIONS: Echogenic thickening of thegallbladder wall and of the main portal vein wall heretofore attributed to fibrosis were frequentlyidentified as fat tissue in MRI. However, the gallbladder wall thickening shown in US (expandedgallbladder fossa in MRI) is probably secondary to combined hepatic morphologic changes inschistosomiasis, representing severe liver involvement.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Although cryptococcal infections begin in the lungs, meningoencephalitis is the most frequently encountered manifestation of cryptococcosis among individuals with advanced immunosuppression. As the infection progresses along the Virchow-Robin spaces, these structures may become dilated with mucoid material produced by the capsule of the organism. We report a case of a 24-year-old man with cryptococcal meningoencephalitis in which magnetic resonance imaging showed clusters of gelatinous pseudocysts in the periventricular white matter, basal ganglia, mammillary bodies, midbrain peduncles and nucleus dentatus with a soap bubble appearance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The authors report the magnetic resonance imaging diagnostic features in two cases with respectively lumbar epidural hematoma and cavernous hemangioma of the lumbar epidural space. Enhanced MRI T1-weighted scans show a hyperintense signal rim surrounding the vascular lesion. Non-enhanced T2-weighted scans showed hyperintense signal.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To determine the consequences of the chronic use of systemic corticosteroids in children with juvenile rheumatoid arthritis by means of evaluating osteochondral effects depicted by magnetic resonance imaging. PATIENTS AND METHODS: We reviewed clinical and magnetic resonance imaging findings in 69 children (72 knees) with juvenile rheumatoid arthritis. Two groups were studied. Group I: 34 (49.3%) children had previous or current use of systemic corticotherapy (22 girls; 12 boys; mean age: 11.3 years; mean disease duration: 5.9 years; mean corticotherapy duration: 2.9 years; mean cumulative dose of previous corticosteroids: 5000 mg); Group II: 35 (50.7%) children had no previous use of corticosteroids (27 girls; 8 boys; mean age: 11.7 years; mean disease duration: 5.3 years). The groups were compared statistically. RESULTS: In the group that had received corticotherapy (Group I), osteochondral abnormalities were significantly correlated to long-standing disease (>3.5 years; p<0.001). This correlation was not found in the group that had no previous history of corticotherapy (Group II). No correlations were established between median dose of corticosteroids and magnetic resonance imaging findings. CONCLUSION: It is important to further investigate the long-term intra-articular effects of systemic corticotherapy to ensure that the side effects of the aggressive therapy will not be more harmful for the joints than the symptoms suffered over the natural course of the disease.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The growing need to patrol and survey large maritime and terrestrial areas increased the need to integrate external sensors on aircraft in order to accomplish those patrols at increasingly higher altitudes, longer range and not depending upon vehicle type. The main focus of this work is to elaborate a practical, simple, effective and efficient methodology for the aircraft modification procedure resulting from the integration of an Elec-tro-Optical/Infra-Red (EO/IR) turret through a support structure. The importance of the devel-opment of a good methodology relies on the correct management of project variables as time, available resources and project complexity. The key is to deliver a proper tool for a project de-sign team that will be used to create a solution that fulfils all technical, non-technical and certi-fication requirements present in this field of transportation. The created methodology is inde-pendent of two main inputs: sensor model and aircraft model definition, and therefore it is in-tended to deliver the results for different projects besides the one that was presented in this work as a case study. This particular case study presents the development of a structure support for FLIR STAR SAPHIRE III turret integration on the front lower fuselage bulkhead (radome) of the LOCKHEED MARTIN C-130 H. Development of the case study focuses on the study of local structural analysis through the use of Finite Element Method (FEM). Development of this Dissertation resulted in a cooperation between Faculty of Science and Technology - Universidade Nova de Lisboa and the company OGMA - Indústria Aeronáutica de Portugal

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cancer is a well-known disease with a significant impact in society not only due to its incidence, more evident in more developed countries, but also due to the expenses related to medical treat-ments. Cancer research is considered an increasingly logical science with great potential for the development of new treatment options. Advances in nanomedicine have resulted in rapid devel-opment of nanomaterials with considerable potential in cancer diagnostics and treatment. The combination of diagnosis and treatment in a single nano-platform is named theranostic. In this PhD thesis a theranostic system for osteosarcoma was proposed, composed by a magnetic core, a polymeric coating, and a chemotherapeutic drug. The presence of a specific targeting agent, in this case a monoclonal antibody, provides high specificity to the proposed theranostic system. For the core of the proposed theranostic system, stable aqueous suspensions of superparamagnetic iron oxide nanoparticles with an average diameter of 9 nm were produced. Chitosan-based poly-meric nanoparticles with a hydrodynamic diameter around 150 nm were successfully produced. Incorporation of iron oxide nanoparticles into the polymeric ones increased their hydrodynamic diameter to at least 250 nm. A monoclonal antibody specific for a transmembranar protein (car-bonic anhydrase IX) present in solid tumors was developed by hybridoma technology. Functional hybridomas producing the desired monoclonal antibodies were obtained. The proposed theranostic system functionality was evaluated in separated parts of its components. Uncoated and coated iron oxide nanoparticles with chitosan-based polymers generated heat under the application of an external alternating magnetic field. Uncoated iron oxide nanoparticles sta-bilized with oleic acid were able to enhance contrast in magnetic resonance imaging. Drug deliv-ery studies were conducted in chitosan-based polymeric nanoparticles without and with the in-corporation of iron oxide nanoparticles, demonstrating to be an effective drug delivery platform for doxorubicin. The theranostic system proposed in this PhD thesis is very promising for cancer theranostic, demonstrating to be applicable in solid tumors such as osteosarcoma.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Schizophrenic patients undergoing proton magnetic resonance spectroscopy show alterations in N-acetyl aspartate levels in several brain regions, indicating neuronal dysfunction. The present review focuses on the main proton magnetic resonance spectroscopy studies in the frontal lobe of schizophrenics. A MEDLINE search, from 1991 to March 2004, was carried out using the key-words spectroscopy and schizophrenia and proton and frontal. In addition, articles cited in the reference list of the studies obtained through MEDLINE were included. As a result, 27 articles were selected. The results were inconsistent, 19 papers reporting changes in the N-acetyl aspartate levels, while 8 reported no change. Methodological analysis led to the conclusion that the discrepancy may be due the following factors: (i) number of participants; (ii) variation in the clinical and demographic characteristics of the groups; (iii) little standardization of the acquisition parameters of spectroscopy. Overall, studies that fulfill strict methodological criteria show N-acetyl aspartate decrease in the frontal lobe of male schizophrenics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To determine the causes of low vision in an elderly population attended by a university visual rehabilitation service and to check for the use of prescribed optical aids. METHOD: A cross-sectional study was carried out on patients aged 60 years or over attending for the first time a university low vision service in 2001. Ophthalmic reevaluation and interview were performed by means of a structured questionnaire in 2002. RESULTS: The sample comprised 50 subjects aged between 60 and 90 years. Severe low vision (<20/200) was present in 68.0% of patients. The main cause of low vision was age-related macular degeneration (44.0%). Regarding literacy, 16.0% were illiterate and 72.0% had completed fundamental schooling. Thirty-one patients (62.0%) had been prescribed optical aids; 54.8% of these patients stated that they use them. A majority (70.6%) held a favorable opinion of these aids. CONCLUSIONS: The main cause of low vision was age-related macular degeneration. Approximately half of those receiving prescriptions reported actually using the aids in their daily activities. Making best use of residual vision in the elderly population with visual impairment is a priority, given the social context, if the independence necessary for enhanced quality of life is to be achieved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The work presented in this thesis aims at developing a new separation process based on the application of supported magnetic ionic liquid membranes, SMILMs, using magnetic ionic liquids, MILs. MILs have attracted growing interest due to their ability to change their physicochemical characteristics when exposed to variable magnetic field conditions. The magnetic responsive behavior of MILs is thus expected to contribute for the development of more efficient separation processes, such as supported liquid membranes, where MILs may be used as a selective carrier. Driven by the MILs behavior, these membranes are expected to switch reversibly their permeability and selectivity by in situ and non-invasive adjustment of the conditions (e.g. intensity, direction vector and uniformity) of an external applied magnetic field. The development of these magnetic responsive membrane processes were anticipated by studies, performed along the first stage of this PhD work, aiming at getting a deep knowledge on the influence of magnetic field on MILs properties. The influence of the magnetic field on the molecular dynamics and structural rearrangement of MILs ionic network was assessed through a 1H-NMR technique. Through the 1H-NMR relaxometry analysis it was possible to estimate the self-diffusion profiles of two different model MILs, [Aliquat][FeCl4] and [P66614][FeCl4]. A comparative analysis was established between the behavior of magnetic and non-magnetic ionic liquids, MILs and ILs, to facilitate the perception of the magnetic field impact on MILs properties. In contrast to ILs, MILs show a specific relaxation mechanism, characterized by the magnetic dependence of their self-diffusion coefficients. MILs self-diffusion coefficients increased in the presence of magnetic field whereas ILs self-diffusion was not affected. In order to understand the reasons underlying the magnetic dependence of MILs self-diffusion, studies were performed to investigate the influence of the magnetic field on MILs’ viscosity. It was observed that the MIL´s viscosity decreases with the increase of the magnetic field, explaining the increase of MILs self-diffusion according to the modified Stokes- Einstein equation. Different gas and liquid transport studies were therefore performed aiming to determine the influence of the magnetic behavior of MILs on solute transport through SMILMs. Gas permeation studies were performed using pure CO2 andN2 gas streams and air, using a series of phosphonium cation based MILs, containing different paramagnetic anions. Transport studies were conducted in the presence and absence of magnetic field at a maximum intensity of 1.5T. The results revealed that gas permeability increased in the presence of the magnetic field, however, without affecting the membrane selectivity. The increase of gas permeability through SMILMs was related to the decrease of the MILs viscosity under magnetic field conditions.(...)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

RESUMO - Os nanomateriais manufaturados (NMs), isto é, fabricados deliberadamente para fins específicos, apresentam propriedades físico-químicas únicas como a dimensão, área superficial ou funcionalização, que lhes conferem caraterísticas mecânicas, óticas, elétricas e magnéticas muito vantajosas para aplicações industriais e biomédicas. Efetivamente, a tecnologia baseada nos NMs, ou nanotecnologia, foi identificada como uma key enabling technology, impulsionadora do crescimento económico dos países industrializados, devido ao seu potencial para melhorar a qualidade e desempenho de muitos tipos de produtos e de processos. Contudo, a expansão da utilização de NMs contrasta com a insuficiente avaliação de risco para a saúde humana e para o ambiente, sendo considerados como um risco emergente para a saúde pública. As incertezas sobre a segurança dos NMs para a saúde pública advêm sobretudo de estudos epidemiológicos em humanos expostos a nanomateriais produzidos como consequência dos processos e atividades humanas e da poluição. Uma das principais preocupações relativamente aos efeitos adversos dos NMs na saúde humana é o seu potencial efeito carcinogénico, que é sugerido por alguns estudos experimentais, como no caso dos nanomateriais de dióxido de titânio ou dos nanotubos de carbono. Para avaliar em curto termo as propriedades carcinogénicas de um composto, utilizam-se frequentemente ensaios de genotoxicidade em linhas celulares de mamífero ou ensaios em modelos animais, em que se analisa uma variedade de lesões genéticas potencialmente relacionados com o processo de carcinogénese. No entanto, a investigação sobre as propriedades genotóxicas dos NMs não foi, até hoje, conclusiva. O presente estudo tem por objectivo principal caracterizar os efeitos genotóxicos associados à exposição a nanomateriais manufaturados, de forma a contribuir para a avaliação da sua segurança. Constituíram objectivos específicos deste estudo: i) avaliar a genotoxicidade dos NMs em três tipos de células humanas expostas in vitro: linfócitos humanos primários, linha celular de epitélio brônquico humano (BEAS-2B) e linha celular de adenocarcinoma epitelial de pulmão humano (A549); ii) avaliar a sua genotoxicidade num modelo de ratinho transgénico; iii) investigar alguns mecanismos de acção que poderão contribuir para a genotoxicidade dos nanomateriais, como a contribuição de lesões oxidativas para a genotoxicidade induzida pelos NMs in vitro, e a investigação da sua bioacumulação e localização celular in vivo. Foram analisados os efeitos genotóxicos associados à exposição a duas classes de NMs, dióxido de titânio e nanotubos de carbono de parede múltipla, bem como a um NM de óxido de zinco, candidato a ser utlilizado como controlo positivo de dimensão nanométrica. Os xx NMs utilizados foram previamente caracterizados com detalhe relativamente às suas características físico-químicas e também relativamente à sua dispersão em meio aquoso e no meio de cultura. A metodologia incluiu ensaios de citotoxicidade e de genotoxicidade in vitro, designadamente, ensaios de quebras no DNA (ensaio do cometa) e nos cromossomas (ensaio do micronúcleo) em células humanas expostas a várias concentrações de NMs, por comparação com células não expostas. Também foram realizados ensaios in vivo de quebras no DNA, quebras cromossómicas e ainda um ensaio de mutações em vários órgãos de grupos de ratinhos transgénicos LacZ, expostos por via intravenosa a duas doses de dióxido de titânio. Foi investigada a existência de uma relação dose-resposta após exposição das células humanas ou dos animais a NMs. A contribuição de lesões oxidativas para a genotoxicidade após exposição das células aos NMs in vitro foi explorada através do ensaio do cometa modificado com enzima. Realizaram-se estudos histológicos e citológicos para deteção e localização celular dos NMs nos órgãos-alvo dos ratinhos expostos in vivo. Os resultados demonstraram efeitos genotóxicos em alguns dos NMs analisados em células humanas. No entanto, os efeitos genotóxicos, quando positivos, foram em níveis reduzidos, ainda que superiores aos valores dos controlos, e a sua reprodutibilidade era dependente do sistema experimental utilizado. Para outros NMs, a evidência de genotoxicidade revelou-se equívoca, conduzindo à necessidade de esclarecimento através de ensaios in vivo. Para esse fim, recorreu-se a uma análise integrada de múltiplos parâmetros num modelo animal, o ratinho transgénico baseado em plasmídeo contendo o gene LacZ exposto a um NM de dióxido de titânio, NM-102. Embora tenha sido demonstrada a exposição e a acumulação do NM no fígado, não se observaram efeitos genotóxicos nem no fígado, nem no baço nem no sangue dos ratinhos expostos a esse NM. Neste estudo concluiu-se que algumas formas de dióxido de titânio e nanotubos de carbono de parede múltipla produzem efeitos genotóxicos em células humanas, contribuindo para o conjunto de evidências sobre o efeito genotóxico desses NMs. As diferenças observadas relativamente à genotoxicidade entre NMs do mesmo tipo, mas distintos em algumas das suas características físico-quimicas, aparentemente não são negligenciáveis, pelo que os resultados obtidos para um NM não devem ser generalizados ao grupo correspondente. Para além disso, a genotoxicidade equívoca verificada para o NM-102 em células humanas expostas in vitro, não foi confirmada no modelo in vivo, pelo que o valor preditivo da utilização dos ensaios in vitro para a identificação de NMs com efeitos genotóxicos (e portanto potencialmente carcinogénicos) ainda tem de ser esclarecido antes de ser possível extrapolar as conclusões para a saúde humana. Por sua vez, como a informação aqui produzida pelas metodologias in vitro e in vivo não reflete os efeitos de exposição continua ou prolongada, que poderá conduzir a efeitos genotóxicos distintos, esta xxi deverá ser complementada com outras linhas de evidência relativamente à segurança dos NMs. Perante a incerteza dos níveis de exposição real do organismo humano e do ambiente, a segurança da utilização dos NMs não pode ser garantida a longo prazo e, tendo em conta a elevada produção e utilização destes NMs, são prementes futuros estudos de monitorização ambiental e humana.