821 resultados para Knee Arthroplasty
Resumo:
Aims: Develop and validate tools to estimate residual noise covariance in Planck frequency maps. Quantify signal error effects and compare different techniques to produce low-resolution maps. Methods: We derive analytical estimates of covariance of the residual noise contained in low-resolution maps produced using a number of map-making approaches. We test these analytical predictions using Monte Carlo simulations and their impact on angular power spectrum estimation. We use simulations to quantify the level of signal errors incurred in different resolution downgrading schemes considered in this work. Results: We find an excellent agreement between the optimal residual noise covariance matrices and Monte Carlo noise maps. For destriping map-makers, the extent of agreement is dictated by the knee frequency of the correlated noise component and the chosen baseline offset length. The significance of signal striping is shown to be insignificant when properly dealt with. In map resolution downgrading, we find that a carefully selected window function is required to reduce aliasing to the sub-percent level at multipoles, ell > 2Nside, where Nside is the HEALPix resolution parameter. We show that sufficient characterization of the residual noise is unavoidable if one is to draw reliable contraints on large scale anisotropy. Conclusions: We have described how to compute the low-resolution maps, with a controlled sky signal level, and a reliable estimate of covariance of the residual noise. We have also presented a method to smooth the residual noise covariance matrices to describe the noise correlations in smoothed, bandwidth limited maps.
Resumo:
Symptomatic hypertrophic breasts cause a health burden with physical and psychosocial morbidity. The value of reduction mammaplasty in the treatment of symptomatic breast hypertrophy has been consistently reported by patients and has been well recognised by plastic surgeons for a long time. However, the scientific evidence of the effects of reduction mammaplasty has been weak or lacking. During the design of this study most of the previous studies were retrospective and the few prospective studies had methodological limitations. Therefore, an obvious need for prospective randomised studies was present. Nevertheless, practical and ethical considerations seemed to make this study design impossible, because the waiting time for the operation was several years. The legislation and subsequent introduction of the uniform criteria for access to non-emergency treatment in Finland removed these obstacles, as all patients received their treatment within a reasonable time. As a result, a randomised controlled trial with a six-month follow-up time was designed and conducted. In addition, a follow-up study with two to five years follow-up was also carried out later. The effects of reduction mammaplasty on the patients breast-related symptoms, psychological symptoms, pain and quality of life was assessed. In addition, factors affecting the outcome were investigated. This study was carried out in the Hospital District of Helsinki and Uusimaa, Finland. Eighty-two out of the approximately 300 patients on the waiting list in 2004 agreed to participate in the study. Patients were randomised either to be operated (40 patients) on or to be followed up (42 patients). The follow-up time for both groups was six months. The patients were operated on by plastic surgeons or trainees at the Department of Plastic Surgery at Helsinki University Central Hospital or at the Department of Surgery at Hyvinkää Hospital. The patients completed five questionnaires: the SF-36 and the 15D quality of life questionnaires, the Finnish Breast-Associated Symptoms questionnaire (FBAS), a mood questionnaire (Raitasalo s modification of the short form of the Beck Depression Inventory, RBDI), and a pain questionnaire (The Finnish Pain Questionnaire, FPQ). Sixty-two out of the original 82 patients agreed to participate in the prospective follow-up study. In this study, patients completed the 15D quality of life questionnaire, the Finnish Breast-Associated Symptoms questionnaire, and the RBDI mood questionnaire. After six months follow-up, patients who had undergone reduction mammaplasty had a significantly better quality of life, fewer breast-associated symptoms and less pain, and they were less depressed or anxious when compared to patients who had not undergone surgery. The change in quality of life was more than two times the minimal clinically important difference. The patients preoperative quality of life was significantly inferior when compared to the age-standardised general population. This health burden was removed with reduction mammaplasty. The health loss related to symptomatic breast hypertrophy was comparable to that of patients with major joint arthrosis. In terms of change in quality of life, the intervention effect of reduction mammaplasty was comparable to that of hip joint replacement and more pronounced than that of knee joint replacement surgery. The outcome of reduction mammaplasty was affected more by preoperative psychosocial factors than by changes in breast dimensions. The effects of reduction mammaplasty remained stable at two to five years follow-up. In terms of quality of life, symptomatic breast hypertrophy causes a considerable health loss comparable to that of major joint arthrosis. Patients who undergo surgery have fewer breast-associated symptoms and less pain, and they are less depressed or anxious and have an improved quality of life. The intervention effect is comparable to that of major joint replacement surgery, and it remains stable at two to five years follow-up. The outcome of reduction mammaplasty is affected by preoperative psychosocial factors.
Resumo:
Thermal oxidative polymerization of alpha-methylstyrene (AMS) has been studied at various temperatures(45-70 degrees C) and pressures (50-400 psi). Due to its high electron dense double bond, it undergoes thermal oxidative polymerization even at low temperatures fairly easily. The major products are poly(alpha-methylstyrene peroxide) (PMSP), and its decomposition products are acetophenone and formaldehyde. Above 45 degrees C the rate of polymerization increases sharply at a particular instant showing an ''autoacceleration'' with the formation of a knee point. The ''autoacceleration'' is supported from the fact that the plot, of R-p vs T shows a rapid rise, and the plot of ln R-p vs 1/T is non-Arrhenius. The occurrence of autoacceleration is explained on the basis of acetophenone-induced cleavage of PMSP during polymerization, generating more initiating alkoxy radicals, which subsequently leads to the rapid rise in the rate of polymerization. The mechanism of autoacceleration is supported by the change in. order, activation energy, and activation volume before and after the knee point.
Resumo:
A novel (main-chain)-(side-chain) vinyl polyperoxide, poly(dipentene peroxide)(PDP), an alternating copolymer of dipentene (DP) and oxygen, has been synthesized by thermal oxidative polymerization of DP. The PDP was characterized by 1H NMR, 13C NMR, FTIR, DSC, TGA, and EI-MS studies. The overall activation energies of the degradation from Kissinger’s method were 28 and 33 kcal/mol, respectively, for the endocyclic and acyclic peroxide units. The side-chain peroxy groups were found to be thermally more stable than the main chain. Above 45°C the rate of polymerization increases sharply at a particular instant showing an “autoacceleration” with the formation of knee point. The kinetics of autoacceleration has been studied at various temperatures (45–70°C) and pressures (50–250 psi). © 2000 John Wiley&Sons, Inc. J Appl Polym Sci 79: 1549–1555, 2001
Resumo:
Ultrahigh-molecular-weight polyethylene (UHMWPE) is used as an articulating surface in total hip and knee joint replacement. In order to enhance long-term durability/wear resistance properties, UHMWPE-based polymer-ceramic hybrid composites are being developed. Surface properties such as wettability and protein adsorption alter with reinforcement or with change in surface chemistry. From this perspective, the wettability and protein adsorption behavior of compression-molded UHMWPE-hydroxyapatite (HA)-aluminum oxide (Al2O3)-carbon nanotube (CNT) composites were analyzed in conjunction with surface roughness. The combined effect of Al2O3 and CNT shows enhancement of the contact angle by similar to 37A degrees compared with the surface of the UHMWPE matrix reinforced with HA. In reference to unreinforced UHMWPE, protein adsorption density also increased by similar to 230% for 2 wt.%HA-5 wt.%Al2O3-2 wt.%CNT addition to UHMWPE. An important conclusion is that the polar and dispersion components of the surface free energy play a significant role in wetting and protein adsorption than do the total free energy or chemistry of the surface. The results of this study have major implications for the biocompatibility of these newly developed biocomposites.
Resumo:
One of the existing issues in implant failure of orthopedic biomaterials is the toxicity induced by the fine particles released during long term use in vivo, leading to acute inflammatory response. In developing a new class of piezobiocomposite to mimic the integrated electrical and mechanical properties of bone, bone-mimicking physical properties as well as in vitro cytocompatibility properties have been achieved with spark plasma sintered hydroxyapatite (HA)-barium titanate (BaTiO3) composites. However, the presence of BaTiO3 remains a concern towards the potential toxicity effect. To address this issue, present work reports the first result to conclusively confirm the non-toxic effect of HA-BaTiO3 piezobiocomposite nanoparticulates, in vivo. Twenty BALB/c mice were intraarticularly injected at their right knee joints with different concentrations of HA-BaTiO3 composite of up to 25 mg/ml. The histopathological examination confirmed the absence of any trace of injected particles or any sign of inflammatory reaction in the vital organs, such as heart, spleen, kidney and liver at 7 days post-exposure period. Rather, the injected nanoparticulates were found to be agglomerated in the vicinity of the knee joint, surrounded by macrophages. Importantly, the absence of any systemic toxicity response in any of the vital organs in the treated mouse model, other than a mild local response at the site of delivery, was recorded. The serum biochemical analyses using proinflammatory cytokines (TNF-alpha and IL-1 beta) also complimented to the non-immunogenic response to injected particulates. Altogether, the absence of any inflammatory/ adverse reaction will open up myriad of opportunities for BaTiO3 based piezoelectric implantable devices in biomedical applications.
Resumo:
The development of new implantable biomaterials requires bone-mimicking physical properties together with desired biocompatible property. In continuation to our earlier published research to establish compositional dependent multifunctional bone-like properties and cytocompatibility response of hydroxyapatite (HA)-BaTiO3 composites, the toxicological property evaluation, both invitro and invivo, were conducted on HA-40wt% BaTiO3 and reported in this work. In particular, this work reports invitro cytotoxicity of mouse myoblast cells as well as invivo long-term tissue and nanoparticles interaction of intra-articularly injected HA-40wt% BaTiO3 and BaTiO3 up to the concentration of 25mg/mL in physiological saline over 12weeks in mouse model. The careful analysis of flow cytometry results could not reveal any statistically significant difference in terms of early/late apoptotic cells or necrotic cells over 8d in culture. Extensive histological analysis could not record any signature of cellular level toxicity or pronounced inflammatory response in vital organs as well as at knee joints of Balb/c mice after 12weeks. Taken together, this study establishes nontoxic nature of HA-40wt% BaTiO3 and therefore, HA-40wt% BaTiO3 can be used safely for various biomedical applications.
Resumo:
The tribe Iphigenieae (Colchicaceace, Liliales) includes two genera, viz. Camptorrhiza and Iphigenia, which are distributed in Africa, India, and Australasia. Iphigenia is represented by 12 species, of which six occur in India while Camptorrhiza comprises one species each in Africa (C. strumosa) and India (C. indica). The genus Camptorrhiza possesses a knee-shaped tuber attached to the corms, filaments with a thick bulge in the middle and styles with single stigma. Iphigenia on the other hand lacks knee-shaped tuber, bears linear filaments and has styles with three stigmas. Camptorrhiza indica possesses ovoid corms, linear filaments and styles with a single stigma. These characters are intermediate between Iphigenia and Camptorrhiza and hence we studied the cytogenetics and phylogenetic placement of this species to ascertain its generic identity. Somatic chromosome count (2n = 22) and karyotypic features of C. indica are very similar to that of Iphigenia species. Molecular phylogenetic studies based on atpB-rbcL, rps16, trnL, and trnL-F regions showed that C. indica is nested within a lineage of Indian Iphigenia species. Thus, C. indica was reduced to a species of Iphigenia, i.e., I. ratnagirica. Camptorrhiza is now a monotypic genus restricted only to southern Africa. A key to the Indian Iphigenia species is provided. In addition, a new combination Wurmbea novae-zelandiae is proposed for Iphigenia novae-zelandiae.
Resumo:
166 p.
Resumo:
An air filled ionization chamber has been constructed with a volume of 552 liters and a wall consisting of 12.7 mg/cm2 of plastic wrapped over a rigid, lightweight aluminum frame. A calibration in absolute units, independent of previous Caltech ion chamber calibrations, was applied to a sealed Neher electrometer for use in this chamber. The new chamber was flown along with an older, argon filled, balloon type chamber in a C-135 aircraft from 1,000 to 40,000 feet altitude, and other measurements of sea level cosmic ray ionization were made, resulting in the value of 2.60 ± .03 ion pairs/cm3 sec atm) at sea level. The calibrations of the two instruments were found to agree within 1 percent, and the airplane data were consistent with previous balloon measurements in the upper atmosphere. Ionization due to radon gas in the atmosphere was investigated. Absolute ionization data in the lower atmosphere have been compared with results of other observers, and discrepancies have been discussed.
Data from a polar orbiting ion chamber on the OGO-II, IV spacecraft have been analyzed. The problem of radioactivity produced on the spacecraft during passes through high fluxes of trapped protons has been investigated, and some corrections determined. Quiet time ionization averages over the polar regions have been plotted as function of altitude, and an analytical fit is made to the data that gives a value of 10.4 ± 2.3 percent for the fractional part of the ionization at the top of the atmosphere due to splash albedo particles, although this result is shown to depend on an assumed angular distribution for the albedo particles. Comparisons with other albedo measurements are made. The data are shown to be consistent with balloon and interplanetary ionization measurements. The position of the cosmic ray knee is found to exhibit an altitude dependence, a North-South effect, and a small local time variation.
Resumo:
[EU]Inpedantzia altuko babes sistema teknika sinplea da non korronte transformadoreak behar dituen babes eskema osatzeko. Korronte transformadore hauek ukondoko tentsio altua, magnetizazio ezaugarri antzekoak eta transformazio erlazio berdina izan behar dute. KT guztiak babestutako objektuaren amaieran jarri behar dira. Fase bakoitzari dagozkion KT guztiak paraleloan konektatu behar dira eta KT guztien juntura puntuan neurri adarra jarri behar da.
Resumo:
[EUS] Aurreko Ligamendu Gurutzatuen (ALG) lesioa gaur egun kirolean gehien ematen den lesioetako bat da. Lesio hau askoz ere ohikoagoa da emakumeengan, eta batez ere kontakturik gabeko egoeretan ematen da. Lesio honen tratamendu eta errekuperazio metodo desberdinak daude gaur egun. Lan honetan bi kasu desberdinen konparaketa egingo da, batez ere, operazio ondorengo errekuperazioan ematen diren desberdintasunetan, eta hauen emaitzetan zentratuz ondorioak atera ahal izateko.
Resumo:
Sabe-se que um estilo de vida sedentário e uma condição aeróbica baixa são associados com uma maior chance de desenvolvimento de doenças cardiovasculares e um maior risco de mortalidade por todas as causas. Contudo, é possível que outros indicadores de aptidão física possam ter significado clínico prognóstico. Originalmente proposto em 1999, o teste de sentar-levantar (TSL) é, simples de executar e possui comprovada reprodutibilidade inter e intra-avaliador. O avaliado inicia o teste com o escore máximo de 5 pontos para cada uma das ações de sentar e levantar, sendo subtraído do mesmo, um ponto para cada apoio extra utilizado (mão, braço e joelho) e meio ponto para cada desequilíbrio corporal perceptível. A pontuação do TSL escore, variando de 0 a 10, é realizada pela soma das ações de sentar e levantar. Considerando o potencial papel da flexibilidade para uma execução mais eficiente de gestos motores, não é surpreendente que o desempenho sobre TSL possa ser influenciado por essa valência. O objetivo desta dissertação foi analisar a relação entre o resultado do TSL e a mortalidade por todas as causas e a flexibilidade. No primeiro estudo, 2002 indivíduos entre 51 e 80 anos (68% homens), realizaram o TSL e os resultados foram estratificados em quatro faixas: 0/3; 3,5/5,5, 6/7,5 and 8/10. Baixos resultados no TSL escore foram associados com um maior risco de mortalidade (p<0,001). Uma tendência contínua de maior sobrevivência se refletiu no ajuste multivariado idade, sexo, índice de massa corporal em um razão de risco de 5,44 [95%IC=3,19,5], 3,44 [95%IC=2,05,9] e 1,84 [95%IC=1,13,0] (p<0,001) dos menores para as maiores faixas de resultados do TSL. Cada aumento de um ponto no escore do TSL significou uma melhora de 21% na sobrevivência. Já o segundo estudo, contou com 3927 indivíduos (67,4% homens) que realizaram o TSL e o Flexiteste. O Flexiteste avalia a amplitude máxima passiva de 20 movimentos corporais. Para cada um dos movimentos, existem cinco escores possíveis, 0 a 4 em uma ordem de mobilidade crescente. A soma dos resultados dos 20 movimentos fornece uma pontuação de flexibilidade global denominada de Flexíndice (FLX). Os resultados do FLX foram estratificados em quartis (626, 2735, 3644 and 4577). Os valores do TSL em cada quartil diferiram entre si (p<0,001). Além disso, o escore do TSL e o FLX foram diretamente associados (r=0,296; p<0,001). Os indivíduos com um TSL escore zero são menos flexíveis para todos os 20 movimentos do Flexiteste do que aqueles com escore 10. Portanto, os dados da presente dissertação, indicam que: o resultado do TSL se mostrou um importante preditor de mortalidade por todas as causas para indivíduos entre 51-80 anos de idade e que indivíduos mais flexíveis tendem a ter maiores escores no TSL.
Resumo:
Estimulação transcraniana por corrente contínua (ETCC) sobre áreas corticais pré-selecionadas, tem aumentado o desempenho físico de diferentes populações. Porém, lacunas persistem no tocante aos mecanismos subjacentes à estes efeitos. Assim, a presente tese objetivou: a) investigar os efeitos da ETCC anódica (aETCC) e placebo (Sham) no córtex motor (CM) de indivíduos saudáveis sobre o desempenho de força máxima; b) comparar os efeitos da ETCC sobre a produção de força máxima e estabilidadade da força durante exercícios máximo e submáximo em sujeitos hemiparéticos e saudáveis; c) investigar o efeito da ETCC sobre a conectividade funcional inter-hemisférica (coerência eletroencefalográfica cEEG) do córtex pré-frontal (CPF), desempenho aeróbio e dispêndio energético (EE) durante e após exercício máximo e submáximo. No 1 estudo, 14 adultos saudáveis executaram 2 sessões de exercício máximo de força (EMF) dos músculos flexores e extensores do joelho dominante (3 séries de 10 rep máximas), precedidos por aETCC ou Sham (2mA; 20 mim). aETCC não foi capaz de aumentar o trabalho total e pico de torque (PT), resistência à fadiga ou atividade eletromiográfica durante o EMF. No 2 estudo, 10 hemiparéticos e 9 sujeitos saudáveis receberam aETCC e Sham no CM. O PT e a estabilidade da força (coeficiente de variação - CV) foram avaliados durante protocolo máximo e submáximo de extensão e flexão unilateral do joelho (1 série de 3 reps a 100% do PT e 2 séries de 10 reps a 50% do PT). Nenhuma diferença no PT foi observada nos dois grupos. Diminuições no CV foram obervadas durante a extensão (~25-35%, P<0.001) e flexão de joelho (~22-33%, P<0.001) após a aETCC comparada com Sham nos hemiparéticos, entretanto, somente o CV na extensão de joelhos diminuiu (~13-27%, P<0.001) nos saudáveis, o que sugere que aETCC pode melhorar o CV, mas não o PT em sujeitos hemiparéticos. No 3 estudo, 9 adultos saudáveis realizaram 2 testes incrementais máximos precedidos por aETCC ou Sham sobre o CPF com as respostas cardiorrespiratórias, percepção de esforço (PSE) e cEEG do CPF sendo monitoradas. O VO2 de pico (42.64.2 vs. 38.23.3 mL.kg.min-1; P=0,02), potência total (252.776.5 vs. 23773.3 W; P=0,05) e tempo de exaustão (531.1140 vs. 486.7115.3 seg; P=0,04) foram maiores após aETCC do que a Sham. Nenhuma diferença foi encontrada para FC e PSE em função da carga de trabalho (P>0,05). A cEEG do CPF aumentou após aETCC vs. repouso (0.700.40 vs. 0.380.05; P=0,001), mas não após Sham vs. repouso (0.360.49 vs. 0.330.50; P=0,06), sugerindo que a aETCC pode retardar a fadiga aumentando a conectividade funcional entre os hemisférios do CPF e desempenho aeróbio durante exercício exaustivo. No 4 estudo, o VO2 e EE foram avaliados em 11 adultos saudáveis antes, durante a aETCC ou Sham no CPF e 30 min após exercício aeróbio submáximo isocalórico (~200kcal). Diferenças não foram observadas no VO2 vs. repouso durante aETCC e Sham (P=0.95 e P=0.85). Porém, a associação entre exercício e aETCC aumentou em ~19% o EE após ao menos, 30 min de recuperação após exercício quando comparada a Sham (P<0,05).
Resumo:
Vibration is commonly used in civil engineering applications to efficiently compact aggregates. This study examined the effect of vibration and drainage on bone graft compaction and cement penetration in an in vitro femoral impaction bone grafting model with the use of 3-dimensional micro-computed tomographic imaging. Three regions were analyzed. In the middle and proximal femoral regions, there was a significant increase in the proportion of bone grafts with a reciprocal reduction in water and air in the vibration-assisted group (P < .01) as compared with the control group, suggesting tighter graft compaction. Cement volume was also significantly reduced in the middle region in the vibration-assisted group. No difference was observed in the distal region. This study demonstrates the value of vibration and drainage in bone graft compaction, with implications therein for clinical application and outcome.