988 resultados para FLUORESCENCE SPECTROMETRY
Resumo:
Two new Ru(phen)(3)(2+)-based surfactants, Ru(phen)(2)(phenNHCO-C-11)(PF6)(2) and Ru(phen)(2)(phenNHCO-C-17)(PF6)(2), have been designed and synthesized, whose chemical structures were characterized by means of IR, H-1 NMR and MS. Also, electrochemistry and fluorescence of them are reported.
Resumo:
A method for the determination of impurity elements in high purity cadmium by inductively coupled plasma mass spectrometry was developed. The spectral interference arising from Cd was discussed and the magnitude of interference by the polyatomic ion of Cd was compared. The effect of the high concentration Cd on the analyte signal was studied. The results showed that Cd possessed both significant suppression effects on the light mass elements signal and enhancement effects on the heavy mass elements signal,and the effects can be corrected by the use of internal standard elements. In this paper, Y and Bi was employed for the light mass elements and the heavy mass elements,respectively. As, Be, Co, Cu, Ga, Ge, Mn, Mo, Pb, Ni, Sr, Au, Tl, Th, V and U in high purity cadmium were determined. Detection limits are 0.005-0.052 mu g L-1,and the recoveries of standard addition are 82%-108%.
Resumo:
Hemorrhagin III (AaH III) was separated and purified from the crude snake venom of Agkistrodon acutus, and its molecule weight was determined accurately to be 23; 284.4 +/- 0.1 by LDI1700-MALDI-TOF-MS. Emission spectra of AaH III showed that Trp residues were located by a great degree in the hydrophobic area. Addition of SDS and guanidine-HCl led to change of the molecular conformation of AaH III, and caused the fluorescence quenching of Trp residues. The red-shifted emission band of AaH III after adding guanidine-HCl showed that Trp residues exposed in polar solvents. The effects of pH, EDTA and metal ions on the fluorescence spectra of AaH III were also investigated.
Resumo:
Four typical LB monolayer film materials, Ru(phen)(3)(2+) complexes with one ligand attached to different long chain alkyl amides, were designed and synthesized. Their chemical structures were identified by the techniques of FT-IR, H-1 NMR and ESI-MS. Also, UV-Vis, electrochemistry and fluorescence of these complexes are reported.
Resumo:
Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS) was used to study a series of synthetic cationic porphyrins as the perchlorate and bromide salts. This work presents the analytical results for the porphyrins obtained using 2,5-dihydroxybenzoic acid (DHB) and 1,8,9-anthratriol as matrices. The selective use of matrix affects ion formation from these porphyrins. By using DHB as the matrix, we not only observed [M - nCIO(4)](+) (n = 1-4) ions, but also obtained [2M - nCIO(4)](+) (n = 2-7) ions from the synthetic cationic porphyrins. The space volume of the side chains (R groups) and the nature of the anions (Br- or CIO4-) affected the relative importance of monomeric and dimeric ions of the porphyrin. The possible mechanisms of desorption and ionization of these cationic porphyrins were also considered in this study. MALDI-TOFMS proved to be a very useful method for obtaining structural information on these synthetic cationic porphyrins. Copyright (C) 1999 John Whey & Sons, Ltd.
Resumo:
Ephedrine and isoephedrine were first distingshed by electrospy ionization mass spectrometry and in-sourice collision-induced dissociation technique. Based on this observation, a unkown sample was identified for ephedrine.
Resumo:
A new series of Ru(II) polypyridine surfactants, Ru(bpy)(2)[phenNH CO(CH2)(n)CH3](PF6)(2), where n is 10, 12, 14 or 16, has been prepared and characterized. The H-1-NMR spectra of these new Ru(II) complexes were attributed and discussed by the H-1-H-1 COSY method. The comparative analysis of IR spectra of these complexes and their responding free ligands has shown that there are intensive d --> pi* feedback interactions between central Ru(II) and their ligands. Their fluorescent, electrochemical and electrochemiluminescent behaviours are also reported.
Resumo:
An experimental setup and the procedure for the laser resonant ionization mass spectrometry (RIMS) have been described. Both an optical spectrum and a mass spectum have been shown. The detection limit that can be reached by using this procedure has been estimated.
Resumo:
This article applied [HEH(HEP)] (2-ethyhexyldrogen-2-ethylhexyl phosphonate)extraction chromatography to separate 14 rare earth impurities from ultra-highly pure Er2O3 and Ho2O3, and then the impurities were determined by atomic emission spectrometry. The average percentage recovery for each element is in the range of 70%similar to 140%. The relative standard deviations of the determination are +/-3.3%similar to 2.2%. This method can be applied to the determination of the trace amounts of rare eath impurities in Er2O3 and Ho2O3 with a purity of 99.999 9%-99.999 99%.
Resumo:
Because of the extremely sensitivity to the local environment of the D-5(0) --> F-7(2) transition of Eu3+ ion, the fluorescence of Eu3+ ions was Studied by introducing Eu3+ ions to TiO2 gel by the sol-gel method, from which the structural changes of TiO2 gel were characterized. The results showed that the intensity of D-5(0) --> F-7(2) transition increased with the increasement of heat treatment temperature, which indicated the evaporation of molecular water and the completeness of the condensation reaction. Because of the quenching of the fluorescence induced by the cluster of Eu3+ ions, the addition of Al3+ ions greatly enhanced the emission intensity of Eu3+ ion.
Resumo:
A method was developed for the determination of total mercury in biological samples. The effects of aqueous ammonia, ethylenediamine and triethanolamine on Hg signal intensity by inductively coupled plasma mass spectrometry has been evaluated and the possible mechanisms discussed. It has been proved that the signal intensity of Hg significantly increases with adding, in the presence of small amounts of aqueous ammonia, ethylenediamine or triethanolamine. The normalized intensity (the signal intensity ratio with amine and without amine) of Hg increases as the concentration of aqueous ammonia, ethylenediamine or triethanolamine increases, but the degree of enhancement of aqueous ammonia was smaller than that of ethylenediamine and triethanolamine. The normalized intensity of Hg with aqueous ammonia, ethylenediamine and triethanolamine decreases as the nebulizer flow rate increases, but decreasing degree of aqueous ammonia was smaller than that of ethylenediamine and triethanolamine. The higher the RF powers the higher the normalized intensity of Hg at the same nebulizer flow rate. The addition of aqueous ammonia, ethylenediamine and triethanolamine into analytical solutions significantly improved the transport efficiency of Hg. The detection limit of Hg is improved about ten times by the addition of ethylenediamine or triethanolamine under the optimum experimental parameters. The method has been used to determine mercury in biological standard reference materials (SRM). The analytical results are very close to the certified values and the determined values for similar samples.
Resumo:
Resonance electron capture mass spectrometry, in which an additional information coordinate, the energy of electron capture, is applied, has a high sensitivity and a high specificity. It is extensively used to study the structure elucidation, the mechanism of ion formation and the detection, identification and quantification of organic substances in mixture.
Resumo:
The cyclic aryletherketone( sulfone) oligomers containing hexafluoroisopropylidene unit were characterized by matrix-assisted laser desorption ionization time-of-night mass spectrometry(MALDI-TOF-MS) using Na+ and Ag+ as cationization agents. The affinities of cyclic oligomers to the cation were studied. The analysis result showed that 1,8,9-dithranol, in the presence of silver trifluoroacetate, was very effective for the characterization of cyclic arylether ketone ( sulfone) containing hexafluoroisopropylidene unit.
Resumo:
The purity and molecular weight of calmodulin have been determined by means of matrix-assisted laser desorption/ionization time of flight mass spectrometry, and the results have been discussed. The experimental results demonstrate that this method is high sensitive and rapid as compared with other traditional methods.
Resumo:
Target transformation factor analysis was used to correct spectral interference in inductively coupled plasma atomic emission spectrometry (ICP-BES) for the determination of rare earth impurities in high purity thulium oxide. Data matrix was constructed with pure and mixture vectors and background vector. A method based on an error evaluation function was proposed to optimize the peak position, so the influence of the peak position shift in spectral scans on the determination was eliminated or reduced. Satisfactory results were obtained using factor analysis and the proposed peak position optimization method.