974 resultados para Abdominal Aortic Aneurism
Resumo:
Aims To evaluate thoracic aortic dilation in patients with Fabry disease (FD). Methods and results A cohort of 106 patients with FD (52 males; 54 females) from three European centres were studied. The diameter of the thoracic aorta was assessed at three levels (sinus of Valsalva, ascending aorta, and descending aorta) using echocardiograms and cardiovascular magnetic resonance imaging. Aortic dilation at the sinus of Valsalva was found in 32.7% of males and 5.6% of females; aneurysms were present in 9.6% of males and 1.9% of females. No aortic dilation was observed in the descending aorta. There was no correlation between aortic diameter at the sinus of Valsalva and cardiovascular risk factors. Conclusion Fabry disease should be considered as a cardiovascular disease that affects the heart and arterial vasculature, including the thoracic aorta. Thus, patients with FD should be closely monitored for the presence, and possible progression and complications of aortic dilation. Clinical Trial Registration: Protocol 101/01. Ethics committee, Faculty of Medicine, Lausanne.
Resumo:
BACKGROUND: Aortoplasty has been advocated for moderate dilatation of the ascending aorta associated with aortic valve disease. We report our results with this conservative approach. METHODS: Seventeen consecutive patients with unsupported aortoplasty were reviewed. Twelve patients had aortic valve regurgitation and 5 had stenosis. The aortic wall was analyzed histologically in 14 patients. Follow-up was complete, with a mean time of 6 years (range, 2.3 to 10.5 years). RESULTS: Two patients among the 15 hospital survivors died during follow-up of causes unrelated to aortic pathology. Survival at 7 years was 86.7% (+/- 8.8%). Recurring aortic aneurysms developed in 4 patients after a mean time of 63 months, with an event-free survival at 7 years of 41% (+/- 21%). All of these 4 patients had aortic valve regurgitation and cystic medial necrosis. CONCLUSIONS: The recurrence rate of aneurysms after unsupported aortoplasty and aortic valve replacement is high in patients with aortic regurgitation. This strongly suggests that in these patients, the aortic dilatation is related to an underlying wall deficiency, associated with the aortic valve pathology, rather than to the hemodynamic stress imposed by the aortic valve disease.
Resumo:
PURPOSE OF REVIEW: The safety and efficiency of trans catheter aortic valve implantation (TAVI) has been clearly demonstrated. In high-risk patients, the number of procedures is constantly increasing and in western European countries this procedure is employed in more than 30% of isolated aortic valve replacements. The literature, however, focusing on perioperative aortic root (AoR) rupture is rather limited to just a few reports. The aim of this review is to analyze the pathophysiology of AoR rupture during TAVI, stressing the implications of the morphology of the AoR for this devastating complication. RECENT FINDINGS: Currently, perioperative AoR rupture ranges between 0.5 and 1.5% during TAVI, with almost 100% mortality. Recently, valve oversizing and balloon dilatation in a calcified and small AoR were considered as the most important predictive factors for this complication. SUMMARY: The most fragile unit of the AoR is its anchoring substrate to the ostium of the left ventricle. This membranous structure is not involved in the degenerative process leading to aortic valve stenosis. Due to the TAVI and/or balloon dilatation of the calcium stationed on the three leaflets and their attachment, a lesion may result on this structure. And, as a consequence, there is rupture of the AoR.
Resumo:
Lambert-Eaton myasthenic syndrome is a paraneoplastic syndrome that may reveal a primitive tumor. Neuroblastoma in children and small cell lung carcinoma in adults are the leading tumors revealed or expressed by paraneoplastic phenomena. The clinical neurologic manifestations of Lambert-Eaton myasthenic syndrome are muscular weakness, sleepiness, absence of reflexes, and dysautonomia. Neurologic manifestations are explained by the induction of an autoimmune response because of the presence of antigens that are expressed by the tumor. Neurologic paraneoplastic disorders may also be the result of toxicity of drugs, coagulopathy, infection, or metabolic diseases. We describe the case of a 13-month-old child with unusual neurologic symptoms because of the presence of an abdominal neuroblastoma.
Resumo:
We report a case of abdominal eventration associated with cystic fibrosis, diagnosed by mid-trimester ultrasonography. The defect concerned the abdominal muscles and their aponevrotic sheath, but respected the skin. There was no associated malformation. The outcome was favorable after surgery, and the infant is well at the age of 6 months.
Resumo:
Aortic stenosis mostly occurs among old-old patients. Once symptoms appear, prognosis is guarded, with 2-year mortality as high as 50%. Transcatheter Aortic Valve Implantation (TAVI) is a new therapeutic option in patients at very high surgical risk, who are mostly older persons. However, TAVI is associated with some complications, and patient selection remains a challenge. Comprehensive geriatric assessment (CGA) identifies patients with medical and functional problems likely to affect the TAVI post-operative course. Collaboration between cardiologists and geriatricians will likely become a standard approach to enhance the assessment of these frail patients and identify those most likely to benefit from TAVI.
Resumo:
Dose kernel convolution (DK) methods have been proposed to speed up absorbed dose calculations in molecular radionuclide therapy. Our aim was to evaluate the impact of tissue density heterogeneities (TDH) on dosimetry when using a DK method and to propose a simple density-correction method. METHODS: This study has been conducted on 3 clinical cases: case 1, non-Hodgkin lymphoma treated with (131)I-tositumomab; case 2, a neuroendocrine tumor treatment simulated with (177)Lu-peptides; and case 3, hepatocellular carcinoma treated with (90)Y-microspheres. Absorbed dose calculations were performed using a direct Monte Carlo approach accounting for TDH (3D-RD), and a DK approach (VoxelDose, or VD). For each individual voxel, the VD absorbed dose, D(VD), calculated assuming uniform density, was corrected for density, giving D(VDd). The average 3D-RD absorbed dose values, D(3DRD), were compared with D(VD) and D(VDd), using the relative difference Δ(VD/3DRD). At the voxel level, density-binned Δ(VD/3DRD) and Δ(VDd/3DRD) were plotted against ρ and fitted with a linear regression. RESULTS: The D(VD) calculations showed a good agreement with D(3DRD). Δ(VD/3DRD) was less than 3.5%, except for the tumor of case 1 (5.9%) and the renal cortex of case 2 (5.6%). At the voxel level, the Δ(VD/3DRD) range was 0%-14% for cases 1 and 2, and -3% to 7% for case 3. All 3 cases showed a linear relationship between voxel bin-averaged Δ(VD/3DRD) and density, ρ: case 1 (Δ = -0.56ρ + 0.62, R(2) = 0.93), case 2 (Δ = -0.91ρ + 0.96, R(2) = 0.99), and case 3 (Δ = -0.69ρ + 0.72, R(2) = 0.91). The density correction improved the agreement of the DK method with the Monte Carlo approach (Δ(VDd/3DRD) < 1.1%), but with a lesser extent for the tumor of case 1 (3.1%). At the voxel level, the Δ(VDd/3DRD) range decreased for the 3 clinical cases (case 1, -1% to 4%; case 2, -0.5% to 1.5%, and -1.5% to 2%). No more linear regression existed for cases 2 and 3, contrary to case 1 (Δ = 0.41ρ - 0.38, R(2) = 0.88) although the slope in case 1 was less pronounced. CONCLUSION: This study shows a small influence of TDH in the abdominal region for 3 representative clinical cases. A simple density-correction method was proposed and improved the comparison in the absorbed dose calculations when using our voxel S value implementation.
Resumo:
Between 1995 and 2005, the number of aortic aneurysms treated annually using endovascular techniques (EVAR) increased from 0 to 50, including all aortic stages. Our organization includes a large team of surgeons, a stock of three complete families of endoprostheses (straight, conical and bifurcated), a mobile trolley with accessories (arterial introducer/introducer sheath, guide wire, catheters, balloons, etc.) and an appliance on wheels for intravascular ultrasound examination (IVUS). This appliance, together with a mobile fluoroscopy device (c-arm), allows endovascular aneurysms analysis of every operating room in our institution, usually without angiography or the use of contrast medium. In general, we are therefore not depending on substantial preoperative imaging in order to identify candidates for endovascular aneurysms repair and can treat abdominal and thoracic aortic ruptures without delay. For endovascular aortic aneurysms repair we distinguish between process steps on the one hand (determining indications, imaging of the access vessels, measurement using IVUS and road mapping via fluoroscopy, selection of implant, implant insertion, positioning, setting the implant, determining success, reconstruction of the access vessel and follow-up) and the level of competence on the other (assistant, senior and directing physicians). Our ultrasound supported technique for endovascular aneurysms repair has been successfully brought to other hospitals using an IVUS transporter and telementoring.
Resumo:
The objective of this study was to assess the efficiency of spiral CT (SCT) aortography for diagnosing acute aortic lesions in blunt thoracic trauma patients. Between October 1992 and June 1997, 487 SCT scans of the chest were performed on blunt thoracic trauma patients. To assess aortic injury, the following SCT criteria were considered: hemomediastinum, peri-aortic hematoma, irregular aspect of the aortic wall, aortic pseudodiverticulum, intimal flap and traumatic dissection. Aortic injury was diagnosed on 14 SCT examinations (2.9 %), five of the patients having had an additional digital aortography that confirmed the aortic trauma. Twelve subjects underwent surgical repair of the thoracic aorta, which in all but one case confirmed the aortic injury. Two patients died before surgery from severe brain lesions. The aortic blunt lesions were confirmed at autopsy. According to the follow-up of the other 473 patients, we are aware of no false-negative SCT examination. Our limited series shows a sensitivity of 100 % and specificity of 99.8 % of SCT aortography in the diagnosis of aortic injury. It is concluded that SCT aortagraphy is an accurate diagnostic method for the assessment of aortic injury in blunt thoracic trauma patients.
Resumo:
BACKGROUND AND AIM OF THE STUDY: Transapical transcatheter aortic valve replacement (TAVR) is a new minimally invasive technique with a known risk of unexpected intra-procedural complications. Nevertheless, the clinical results are good and the limited amount of procedural adverse events confirms the usefulness of a synergistic surgical/anesthesiological management in case of unexpected emergencies. METHODS: A review was made of the authors' four-year database and other available literature to identify major and minor intra-procedural complications occurring during transapical TAVR procedures. All implants were performed under general anesthesia with a balloon-expandable Edwards Sapien stent-valve, and followed international guidelines on indications and techniques. RESULTS: Procedural success rates ranged between 94% and 100%. Life-threatening apical bleeding occurred very rarely (0-5%), and its incidence decreased after the first series of implants. Stent-valve embolization was also rare, with a global incidence ranging from 0-2%, with evidence of improvement after the learning curve. Rates of valve malpositioning ranged from 0% to < 3%, whereas the risk of coronary obstruction ranged from 0% to 3.5%. Aortic root rupture and dissection were dramatic events reported in 0-2% of transapical cases. Stent-valve malfunction was rarely reported (1-2%), whereas the valve-in-valve bailout procedure for malpositioning, malfunctioning or severe paravalvular leak was reported in about 1.0-3.5% of cases. Sudden hemodynamic management and bailout procedures such as valve-in-valve rescue or cannulation for cardiopulmonary bypass were more effective when planned during the preoperative phase. CONCLUSION: Despite attempts to avoid pitfalls, complications during transapical aortic valve procedures still occur. Preoperative strategic planning, including hemodynamic status management, alternative cannulation sites and bailout procedures, are highly recommended, particularly during the learning curve of this technique.
Resumo:
Tumors in non-Hodgkin lymphoma (NHL) patients are often proximal to the major blood vessels in the abdomen or neck. In external-beam radiotherapy, these tumors present a challenge because imaging resolution prevents the beam from being targeted to the tumor lesion without also irradiating the artery wall. This problem has led to potentially life-threatening delayed toxicity. Because radioimmunotherapy has resulted in long-term survival of NHL patients, we investigated whether the absorbed dose (AD) to the artery wall in radioimmunotherapy of NHL is of potential concern for delayed toxicity. SPECT resolution is not sufficient to enable dosimetric analysis of anatomic features of the thickness of the aortic wall. Therefore, we present a model of aortic wall toxicity based on data from 4 patients treated with (131)I-tositumomab. METHODS: Four NHL patients with periaortic tumors were administered pretherapeutic (131)I-tositumomab. Abdominal SPECT and whole-body planar images were obtained at 48, 72, and 144 h after tracer administration. Blood-pool activity concentrations were obtained from regions of interest drawn on the heart on the planar images. Tumor and blood activity concentrations, scaled to therapeutic administered activities-both standard and myeloablative-were input into a geometry and tracking model (GEANT, version 4) of the aorta. The simulated energy deposited in the arterial walls was collected and fitted, and the AD and biologic effective dose values to the aortic wall and tumors were obtained for standard therapeutic and hypothetical myeloablative administered activities. RESULTS: Arterial wall ADs from standard therapy were lower (0.6-3.7 Gy) than those typical from external-beam therapy, as were the tumor ADs (1.4-10.5 Gy). The ratios of tumor AD to arterial wall AD were greater for radioimmunotherapy by a factor of 1.9-4.0. For myeloablative therapy, artery wall ADs were in general less than those typical for external-beam therapy (9.4-11.4 Gy for 3 of 4 patients) but comparable for 1 patient (32.6 Gy). CONCLUSION: Blood vessel radiation dose can be estimated using the software package 3D-RD combined with GEANT modeling. The dosimetry analysis suggested that arterial wall toxicity is highly unlikely in standard dose radioimmunotherapy but should be considered a potential concern and limiting factor in myeloablative therapy.