873 resultados para visual surveillance system


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Sparse representation based visual tracking approaches have attracted increasing interests in the community in recent years. The main idea is to linearly represent each target candidate using a set of target and trivial templates while imposing a sparsity constraint onto the representation coefficients. After we obtain the coefficients using L1-norm minimization methods, the candidate with the lowest error, when it is reconstructed using only the target templates and the associated coefficients, is considered as the tracking result. In spite of promising system performance widely reported, it is unclear if the performance of these trackers can be maximised. In addition, computational complexity caused by the dimensionality of the feature space limits these algorithms in real-time applications. In this paper, we propose a real-time visual tracking method based on structurally random projection and weighted least squares techniques. In particular, to enhance the discriminative capability of the tracker, we introduce background templates to the linear representation framework. To handle appearance variations over time, we relax the sparsity constraint using a weighed least squares (WLS) method to obtain the representation coefficients. To further reduce the computational complexity, structurally random projection is used to reduce the dimensionality of the feature space while preserving the pairwise distances between the data points in the feature space. Experimental results show that the proposed approach outperforms several state-of-the-art tracking methods.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Burial grounds are commonly surveyed and searched by both police/humanitarian search teams and archaeologists.
One aspect of an efficient search is to establish areas free of recent internments to allow the concentration of assets in suspect
terrain. While 100% surety in locating remains can never be achieved, the deployment of a red, amber green (RAG) system for
assessment has proven invaluable to our surveys. The RAG system is based on a desktop study (including burial ground
records), visual inspection (mounding, collapses) and use of geophysics (in this case, ground penetrating radar or GPR) for a
multi-proxy assessment that provides search authorities an assessment of the state of inhumations and a level of legal backup
for decisions they make on excavation or not (‘exit strategy’). The system is flexible and will be built upon as research
continues.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective
Based on the theory of incentive sensitization, the aim of this study was to investigate differences in attentional processing of food-related visual cues between normal-weight and overweight/obese males and females.

Methods
Twenty-six normal-weight (14M, 12F) and 26 overweight/obese (14M, 12F) adults completed a visual probe task and an eye-tracking paradigm. Reaction times and eye movements to food and control images were collected during both a fasted and fed condition in a counterbalanced design.

Results
Participants had greater visual attention towards high-energy-density food images compared to low-energy-density food images regardless of hunger condition. This was most pronounced in overweight/obese males who had significantly greater maintained attention towards high-energy-density food images when compared with their normal-weight counterparts however no between weight group differences were observed for female participants.

Conclusions
High-energy-density food images appear to capture visual attention more readily than low-energy-density food images. Results also suggest the possibility of an altered visual food cue-associated reward system in overweight/obese males. Attentional processing of food cues may play a role in eating behaviors thus should be taken into consideration as part of an integrated approach to curbing obesity.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper presents a new framework for multi-subject event inference in surveillance video, where measurements produced by low-level vision analytics usually are noisy, incomplete or incorrect. Our goal is to infer the composite events undertaken by each subject from noise observations. To achieve this, we consider the temporal characteristics of event relations and propose a method to correctly associate the detected events with individual subjects. The Dempster–Shafer (DS) theory of belief functions is used to infer events of interest from the results of our vision analytics and to measure conflicts occurring during the event association. Our system is evaluated against a number of videos that present passenger behaviours on a public transport platform namely buses at different levels of complexity. The experimental results demonstrate that by reasoning with spatio-temporal correlations, the proposed method achieves a satisfying performance when associating atomic events and recognising composite events involving multiple subjects in dynamic environments.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper investigated using lip movements as a behavioural biometric for person authentication. The system was trained, evaluated and tested using the XM2VTS dataset, following the Lausanne Protocol configuration II. Features were selected from the DCT coefficients of the greyscale lip image. This paper investigated the number of DCT coefficients selected, the selection process, and static and dynamic feature combinations. Using a Gaussian Mixture Model - Universal Background Model framework an Equal Error Rate of 2.20% was achieved during evaluation and on an unseen test set a False Acceptance Rate of 1.7% and False Rejection Rate of 3.0% was achieved. This compares favourably with face authentication results on the same dataset whilst not being susceptible to spoofing attacks.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Free-roaming dogs (FRD) represent a potential threat to the quality of life in cities from an ecological, social and public health point of view. One of the most urgent concerns is the role of uncontrolled dogs as reservoirs of infectious diseases transmittable to humans and, above all, rabies. An estimate of the FRD population size and characteristics in a given area is the first step for any relevant intervention programme. Direct count methods are still prominent because of their non-invasive approach, information technologies can support such methods facilitating data collection and allowing for a more efficient data handling. This paper presents a new framework for data collection using a topological algorithm implemented as ArcScript in ESRI® ArcGIS software, which allows for a random selection of the sampling areas. It also supplies a mobile phone application for Android® operating system devices which integrates Global Positioning System (GPS) and Google Maps™. The potential of such a framework was tested in 2 Italian regions. Coupling technological and innovative solutions associated with common counting methods facilitate data collection and transcription. It also paves the way to future applications, which could support dog population management systems.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: To assess the impact of laser peripheral iridotomy (LPI) on forward-scatter of light and subjective visual symptoms and to identify LPI parameters influencing these phenomena. DESIGN: Cohort study derived from a randomized trial, using an external control group. PARTICIPANTS: Chinese subjects initially aged 50 or older and 70 years or younger with bilateral narrow angles undergoing LPI in 1 eye selected at random, and age- and gender-matched controls. METHODS: Eighteen months after laser, LPI-treated subjects underwent digital iris photography and photogrammetry to characterize the size and location of the LPI, Lens Opacity Classification System III cataract grading, and measurement of retinal straylight (C-Quant; OCULUS, Wetzlar, Germany) in the treated and untreated eyes and completed a visual symptoms questionnaire. Controls answered the questionnaire and underwent straylight measurement and (in a random one-sixth sample) cataract grading. MAIN OUTCOME MEASURES: Retinal straylight levels and subjective visual symptoms. RESULTS: Among 230 LPI-treated subjects (121 [58.8%] with LPI totally covered by the lid, 43 [19.8%] with LPI partly covered by the lid, 53 [24.4%] with LPI uncovered by the lid), 217 (94.3%) completed all testing, as did 250 (93.3%) of 268 controls. Age, gender, and prevalence of visual symptoms did not differ between treated subjects and controls, although nuclear (P<0.01) and cortical (P = 0.03) cataract were less common among controls. Neither presenting visual acuity nor straylight score differed between the treated and untreated eyes among all treated persons, nor among those (n = 96) with LPI partially or totally uncovered. Prevalence of subjective glare did not differ significantly between participants with totally covered LPI (6.61%; 95% confidence interval [CI], 3.39%-12.5%), partially covered LPI (11.6%; 95% CI, 5.07%-24.5%), or totally uncovered LPI (9.43%; 95% CI, 4.10%-10.3%). In regression models, only worse cortical cataract grade (P = 0.01) was associated significantly with straylight score, and no predictors were associated with subjective glare. None of the LPI size or location parameters were associated with straylight or subjective symptoms. CONCLUSIONS: These results suggests that LPI is safe regarding measures of straylight and visual symptoms. This randomized design provides strong evidence that treatment programs for narrow angles would be unlikely to result in important medium-term visual disability.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

As infraestruturas de televisão interativa atualmente existentes possibilitam a integração de uma grande variedade de recursos e serviços, possibilitando aos utilizadores novas experiências de interação e participação. Para a maioria dos telespetadores, o uso de serviços interativos não acarreta grandes dificuldades; no entanto, para públicos com necessidades especiais, por exemplo para pessoas com défice visual, essa tarefa torna-se complexa, dificultando, ou mesmo impedindo, que estes utilizadores possam beneficiar deste tipo de serviços. Portugal não é uma exceção neste contexto, existindo um número significativo de utilizadores com défice visual (UDV) que não beneficiam totalmente das potencialidades do paradigma televisivo atual. Neste âmbito, o projeto de investigação que suporta esta tese explora a problemática do Design Universal aplicado à Televisão Interativa (iTV) e tem como objetivos a conceptualização, prototipagem e validação de um serviço de iTV adaptado especificamente a UDV, visando promover a sua inclusão digital. Para cumprir estes objetivos, a investigação dividiu-se em três etapas distintas. Na primeira etapa, a partir da Teoria Fundamentada nos Dados, foram identificadas as dificuldades e necessidades dos UDV enquanto consumidores de conteúdos televisivos e serviços de audiodescrição; foi selecionada a plataforma tecnológica mais adequada para o suporte do serviço prototipado; e foi definido um conjunto de princípios orientadores de design (POD’s) de interfaces de televisão interativa específico para este público-alvo. Inicialmente foram efetuadas duas entrevistas a 20 participantes com défice visual, para determinar as suas dificuldades e necessidades enquanto consumidores de conteúdos televisivos e serviços de audiodescrição. De seguida, foi realizada uma entrevista a um perito responsável pelo processo de transição para a TDT em Portugal (inicialmente considerou-se que a TDT seria uma plataforma promissora e poderia suportar o protótipo) e efetuada a revisão da literatura sobre POD’s para o desenvolvimento de interfaces para serviços iTV dirigidos a pessoas com défice visual. A partir dos resultados obtidos nesta etapa foi possível definir os requisitos funcionais e técnicos do sistema, bem como os seus PODs, tanto ao nível da componente gráfica, como de interação. Na segunda etapa foi concetualizado e desenvolvido o protótipo iTV adaptado a UDV ‘meo ad+’, com recurso à plataforma tecnológica IPTV da Portugal Telecom, seguindo os requisitos e os princípios de design definidos. Relativamente à terceira etapa, esta contemplou a avaliação do serviço prototipado, por parte de um grupo de participantes com défice visual. Esta fase do trabalho foi conduzida através do método de Estudo Avaliativo, possibilitando, através de testes de usabilidade e acessibilidade, complementados com entrevistas, compreender se o serviço prototipado ia efetivamente ao encontro das necessidades deste tipo de utilizadores, tendo-se observado que os participantes que estiveram envolvidos nos testes ao protótipo mostraram-se satisfeitos com as funcionalidades oferecidas pelo sistema, bem como com o design da sua interface.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Hintergrund und Fragestellung: Die korrekte intraoperative Positionierung und Einstellung eines mobilen Bildverstärkers (auch C-Bogen) kann zurzeit theoretisch mit Hilfe von Lehrbüchern erlernt, am Gerät selbst aber nur ohne visuelle Rückmeldung, d.h. ohne ein zur Ausrichtung korrespondierendes Röntgenbild, trainiert werden. Hieraus ergibt sich die Fragestellung, inwiefern das Training der Handhabung und richtigen Einstellung des C-Bogens in verschiedenen Operationsszenarien durch ein C-Bogen Simulationssystem als Teil eines CBT-Systems (Computer Based Training) unterstützt werden kann. Methoden: In Kooperation mit Ärzten aus Unfallchirurgie und Radiologie wurde das computer-basierte Trainingssystem virtX entwickelt. virtX kann dem Nutzer verschiedene Aufgaben zur Einstellung eines C-Bogens stellen und die Ausführung und das Ergebnis bewerten. Die Aufgaben können mit Hilfe eines Autorensystems erstellt und vom Trainierenden in verschiedenen Modi erfüllt werden: im rein virtuellen Modus oder im kombinierten virtuell-realen Modus. Im rein virtuellen Modus steuert der Nutzer den virtuellen C-Bogen in einem virtuellen OP-Saal mittels einer grafisch-interaktiven Benutzungsoberfläche. Im virtuell-realen Modus hingegen wird die Ausrichtung eines realen C-Bogens erfasst und auf den virtuellen C-Bogen übertragen. Während der Aufgabenerfüllung kann der Benutzer zu jeder Zeit ein realitätsnahes, virtuelles Röntgenbild erzeugen und dabei alle Parameter wie Blendenstellung, Röntgenintensität, etc. wie bei einem realen C-Bogen steuern. virtX wurde auf einem dreitägigen Kurs für OP-Personal mit 120 Teilnehmern eingesetzt und auf der Basis von Fragebögen evaluiert. Ergebnisse: Von den Teilnehmern gaben 79 einen ausgefüllten Evaluations-Fragebogen ab. Das Durchschnittsalter der 62 weiblichen und 15 männlichen Teilnehmer (zwei o.A.) lag bei 34 ± 9 Jahren, die Berufserfahrung bei 8,3 ± 7,6 Jahren. 18 Personen (23%) gaben an, gelegentlich mit einem C-Bogen zu arbeiten, 61 (77%) arbeiteten regelmäßig damit. Über 83% der befragten Teilnehmer empfanden virtX als eine sinnvolle Ergänzung zur herkömmlichen Ausbildung am C-Bogen. Das virtuelle Röntgen wurde mit einer Zustimmung von 91% der befragten Teilnehmer als besonders wichtig für das Verständnis der Arbeitsweise eines C-Bogens beurteilt. Ebenso erhielt der kombinierte virtuell-reale Modus mit 84% Zustimmung einen vergleichsweise hohen Stellenwert. Schlussfolgerung: Die Befragung zeichnet ein positives Bild der Akzeptanz des virtX-System als substanzielle Ergänzung zur herkömmlichen Ausbildung am C-Bogen.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Tese de doutoramento, Belas-Artes (Educação Artística), Universidade de Lisboa, Faculdade de Belas-Artes, 2014

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Thesis (Ph.D.)--University of Washington, 2016-02

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Rapid developments in display technologies, digital printing, imaging sensors, image processing and image transmission are providing new possibilities for creating and conveying visual content. In an age in which images and video are ubiquitous and where mobile, satellite, and three-dimensional (3-D) imaging have become ordinary experiences, quantification of the performance of modern imaging systems requires appropriate approaches. At the end of the imaging chain, a human observer must decide whether images and video are of a satisfactory visual quality. Hence the measurement and modeling of perceived image quality is of crucial importance, not only in visual arts and commercial applications but also in scientific and entertainment environments. Advances in our understanding of the human visual system offer new possibilities for creating visually superior imaging systems and promise more accurate modeling of image quality. As a result, there is a profusion of new research on imaging performance and perceived quality.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Dissertação apresentada à Escola Superior de Comunicação Social como parte dos requisitos para obtenção de grau de mestre em Publicidade e Marketing.