940 resultados para reproducibility of calculated surfaces
Resumo:
This paper presents a validation study on statistical nonsupervised brain tissue classification techniques in magnetic resonance (MR) images. Several image models assuming different hypotheses regarding the intensity distribution model, the spatial model and the number of classes are assessed. The methods are tested on simulated data for which the classification ground truth is known. Different noise and intensity nonuniformities are added to simulate real imaging conditions. No enhancement of the image quality is considered either before or during the classification process. This way, the accuracy of the methods and their robustness against image artifacts are tested. Classification is also performed on real data where a quantitative validation compares the methods' results with an estimated ground truth from manual segmentations by experts. Validity of the various classification methods in the labeling of the image as well as in the tissue volume is estimated with different local and global measures. Results demonstrate that methods relying on both intensity and spatial information are more robust to noise and field inhomogeneities. We also demonstrate that partial volume is not perfectly modeled, even though methods that account for mixture classes outperform methods that only consider pure Gaussian classes. Finally, we show that simulated data results can also be extended to real data.
Resumo:
In sentinel node (SN) biopsy, an interval SN is defined as a lymph node or group of lymph nodes located between the primary melanoma and an anatomically well-defined lymph node group directly draining the skin. As shown in previous reports, these interval SNs seem to be at the same metastatic risk as are SNs in the usual, classic areas. This study aimed to review the incidence, lymphatic anatomy, and metastatic risk of interval SNs. METHODS: SN biopsy was performed at a tertiary center by a single surgical team on a cohort of 402 consecutive patients with primary melanoma. The triple technique of localization was used-that is, lymphoscintigraphy, blue dye, and gamma-probe. Otolaryngologic melanoma and mucosal melanoma were excluded from this analysis. SNs were examined by serial sectioning and immunohistochemistry. All patients with metastatic SNs were recommended to undergo a radical selective lymph node dissection. RESULTS: The primary locations of the melanomas included the trunk (188), an upper limb (67), or a lower limb (147). Overall, 97 (24.1%) of the 402 SNs were metastatic. Interval SNs were observed in 18 patients, in all but 2 of whom classic SNs were also found. The location of the primary was truncal in 11 (61%) of the 18, upper limb in 5, and lower limb in 2. One patient with a dorsal melanoma had drainage exclusively in a cervicoscapular area that was shown on removal to contain not lymph node tissue but only a blue lymph channel without tumor cells. Apart from the interval SN, 13 patients had 1 classic SN area and 3 patients 2 classic SN areas. Of the 18 patients, 2 had at least 1 metastatic interval SN and 2 had a classic SN that was metastatic; overall, 4 (22.2%) of 18 patients were node-positive. CONCLUSION: We found that 2 of 18 interval SNs were metastatic: This study showed that preoperative lymphoscintigraphy must review all known lymphatic areas in order to exclude an interval SN.
Resumo:
Direct MR arthrography has a better diagnostic accuracy than MR imaging alone. However, contrast material is not always homogeneously distributed in the articular space. Lesions of cartilage surfaces or intra-articular soft tissues can thus be misdiagnosed. Concomitant application of axial traction during MR arthrography leads to articular distraction. This enables better distribution of contrast material in the joint and better delineation of intra-articular structures. Therefore, this technique improves detection of cartilage lesions. Moreover, the axial stress applied on articular structures may reveal lesions invisible on MR images without traction. Based on our clinical experience, we believe that this relatively unknown technique is promising and should be further developed.
Resumo:
The semi-structured diagnostic interview for genetic studies (DIGS) was developed to assess major mood and psychotic disorders and their spectrum manifestations in genetic studies. Our research group developed a French version of the DIGS and tested its inter-rater and test-retest reliability in psychiatric patients. In this article, we present estimates of the reliability of substance use and antisocial personality disorders. High kappa coefficients for inter-rater reliability were found for drug and alcohol as well as antisocial personality diagnoses and slightly lower kappas for test-retest reliability. Combined with evidence of the reliability of major mood and psychotic disorders, these findings support the suitability of the DIGS for studies of familial aggregation and comorbidity of psychiatric disorders including substance use and antisocial personality disorders.
Resumo:
BACKGROUND: Epidemiological studies show that up to 10% of individuals aged 65 years and older suffer from dementia, most commonly from dementia of the Alzheimer Type (DAT) (1). Clinicopathological studies are critical to our understanding of this disease and improving the accuracy of clinical diagnoses. OBJECTIVES: Our objectives were to examine the validity of clinical diagnoses of DAT, to determine the prevalence of different forms of dementia in this sample, and to investigate the relationship between age at death and polymorbidity. SUBJECTS AND METHOD: Clinical data were available from 221 patients who had been examined at the Basel Memory Clinic between 1986 and 1996. From this population, 34% (75 patients) were autopsied in the Department of Pathology, University Hospital Basel, and neuropathological examinations were additionally performed on 62 (83%) of these patients. Clinical and neuropathological data were retrospectively compared. RESULTS: 67.8% of the neuropathologically examined patients received a definitive diagnosis of AD (Alzheimer's disease), vascular dementia (VaD) or mixed dementia (AD and VaD). AD alone or with other histopathological hallmarks of dementia was the most prevalent neuropathological diagnosis (63%). VaD was deemed the only cause of dementia in only 4.8% of patients. The sensitivity for DAT was 75.9%, the specificity 60.6%. Increasing age was associated with an increasing number of clinical and neuropathological diagnoses. CONCLUSION: The sensitivity and specificity of the clinical diagnoses of DAT found in our study are similar to previous reports (2-5). Older patients had more etiologies of their dementia than younger patients. This study reaffirms the need for internationally accepted criteria for clinical and neuropathological diagnoses, as well as further clinical-neuropathological investigations to further refine the clinical diagnostic process.
Resumo:
The objective of this study was to assess the efficiency of spiral CT (SCT) aortography for diagnosing acute aortic lesions in blunt thoracic trauma patients. Between October 1992 and June 1997, 487 SCT scans of the chest were performed on blunt thoracic trauma patients. To assess aortic injury, the following SCT criteria were considered: hemomediastinum, peri-aortic hematoma, irregular aspect of the aortic wall, aortic pseudodiverticulum, intimal flap and traumatic dissection. Aortic injury was diagnosed on 14 SCT examinations (2.9 %), five of the patients having had an additional digital aortography that confirmed the aortic trauma. Twelve subjects underwent surgical repair of the thoracic aorta, which in all but one case confirmed the aortic injury. Two patients died before surgery from severe brain lesions. The aortic blunt lesions were confirmed at autopsy. According to the follow-up of the other 473 patients, we are aware of no false-negative SCT examination. Our limited series shows a sensitivity of 100 % and specificity of 99.8 % of SCT aortography in the diagnosis of aortic injury. It is concluded that SCT aortagraphy is an accurate diagnostic method for the assessment of aortic injury in blunt thoracic trauma patients.
Resumo:
Lithium is an efficacious agent for the treatment of bipolar disorder, but it is unclear to what extent its long-term use may result in neuroprotective or toxic consequences. Medline was searched with the combination of the word 'Lithium' plus key words that referred to every possible effect on the central nervous system. The papers were further classified into those supporting a neuroprotective effect, those in favour of a neurotoxic effect and those that were neutral. The papers were classified into research in humans, animal and in-vitro research, case reports, and review/opinion articles. Finally, the Natural Standard evidence-based validated grading rationale was used to validate the data. The Medline search returned 970 papers up to February 2006. Inspection of the abstracts supplied 214 papers for further reviewing. Eighty-nine papers supported the neuroprotective effect (6 human research, 58 animal/in vitro, 0 case reports, 25 review/opinion articles). A total of 116 papers supported the neurotoxic effect (17 human research, 23 animal/in vitro, 60 case reports, 16 review/opinion articles). Nine papers supported no hypothesis (5 human research, 3 animal/in vitro, 0 case reports, 1 review/opinion articles). Overall, the grading suggests that the data concerning the effect of lithium therapy is that of level C, that is 'unclear or conflicting scientific evidence' since there is conflicting evidence from uncontrolled non-randomized studies accompanied by conflicting evidence from animal and basic science studies. Although more papers are in favour of the toxic effect, the great difference in the type of papers that support either hypothesis, along with publication bias and methodological issues make conclusions difficult. Lithium remains the 'gold standard' for the prophylaxis of bipolar illness, however, our review suggests that there is a rare possibility of a neurotoxic effect in real-life clinical practice even in closely monitored patients with 'therapeutic' lithium plasma levels. It is desirable to keep lithium blood levels as low as feasible with prophylaxis.
Resumo:
BACKGROUND: Current bilevel positive-pressure ventilators for home noninvasive ventilation (NIV) provide physicians with software that records items important for patient monitoring, such as compliance, tidal volume (Vt), and leaks. However, to our knowledge, the validity of this information has not yet been independently assessed. METHODS: Testing was done for seven home ventilators on a bench model adapted to simulate NIV and generate unintentional leaks (ie, other than of the mask exhalation valve). Five levels of leaks were simulated using a computer-driven solenoid valve (0-60 L/min) at different levels of inspiratory pressure (15 and 25 cm H(2)O) and at a fixed expiratory pressure (5 cm H(2)O), for a total of 10 conditions. Bench data were compared with results retrieved from ventilator software for leaks and Vt. RESULTS: For assessing leaks, three of the devices tested were highly reliable, with a small bias (0.3-0.9 L/min), narrow limits of agreement (LA), and high correlations (R(2), 0.993-0.997) when comparing ventilator software and bench results; conversely, for four ventilators, bias ranged from -6.0 L/min to -25.9 L/min, exceeding -10 L/min for two devices, with wide LA and lower correlations (R(2), 0.70-0.98). Bias for leaks increased markedly with the importance of leaks in three devices. Vt was underestimated by all devices, and bias (range, 66-236 mL) increased with higher insufflation pressures. Only two devices had a bias < 100 mL, with all testing conditions considered. CONCLUSIONS: Physicians monitoring patients who use home ventilation must be aware of differences in the estimation of leaks and Vt by ventilator software. Also, leaks are reported in different ways according to the device used.
Resumo:
To assess religious coping in schizophrenia, we developed and tested a clinical grid, as no validated questionnaire exists for this population. One hundred fifteen outpatients were interviewed. Results obtained by 2 clinicians were compared. Religion was central in the lives of 45% of patients, 60% used religion extensively to cope with their illness. Religion is a multifaceted construct. Principal component analysis elicited 4 factors: subjective dimension, collective dimension, synergy with psychiatric treatment, and ease of talking about religion with psychiatrist. Different associations were found between these factors and psychopathology, substance abuse, and psychosocial adaptation. The high prevalence of spirituality and religious coping clearly indicates the necessity of addressing spirituality in patient care. Our clinical grid is suitable for this purpose. It proved its applicability to a broad diversity of religious beliefs, even pathological ones. Interjudge reliability and construct validity were high and specific training is not required.
Resumo:
PURPOSE: To prospectively evaluate the accuracy and reliability of "freehand" posttraumatic orbital wall reconstruction with AO (Arbeitsgemeinschaft Osteosynthese) titanium mesh plates by using computer-aided volumetric measurement of the bony orbits. METHODS: Bony orbital volume was measured in 12 patients from coronal CT scan slices using OsiriX Medical Image software. After defining the volumetric limits of the orbit, the segmentation of the bony orbital region of interest of each single slice was performed. At the end of the segmentation process, all regions of interest were grouped and the volume was computed. The same procedure was performed on both orbits, and thereafter the volume of the contralateral uninjured orbit was used as a control for comparison. RESULTS: In all patients, the volume data of the reconstructed orbit fitted that of the contralateral uninjured orbit with accuracy to within 1.85 cm3 (7%). CONCLUSIONS: This preliminary study has demonstrated that posttraumatic orbital wall reconstruction using "freehand" bending and placement of AO titanium mesh plates results in a high success rate in re-establishing preoperative bony volume, which closely approximates that of the contralateral uninjured orbit.
Resumo:
Given the low sensitivity of amoebal coculture, we developed a specific real-time PCR for the detection of Parachlamydia. The analytical sensitivity was high, and the inter- and intrarun variabilities were low. When the PCR was applied to nasopharyngeal aspirates, it was positive for six patients with bronchiolitis. Future studies should assess the role of Parachlamydia in bronchiolitis.
Resumo:
AIM: The aim of this cross-sectional study was to provide normative data (ordinal scores and timed performances) for gross and fine motor tasks in typically developing children between 3 and 5 years of age using the Zurich Neuromotor Assessment (ZNA). METHOD: Typically developing children (n=101; 48 males, 53 females) between 3 and 5 years of age were enrolled from day-care centres in the greater Zurich area and tested using a modified version of the ZNA; the tests were recorded digitally on video. Intraobserver reliability was assessed on the videos of 20 children by one examiner. Interobserver reliability was assessed by two examiners. Test-retest reliability was performed on an additional 20 children. The modelling approach summarized the data with a linear age effect and an additive term for sex, while incorporating informative missing data in the normative values. Normative data for adaptive motor tasks, pure motor tasks, and static and dynamic balance were calculated with centile curves (for timed performance) and expected ordinal scores (for ordinal scales). RESULTS: Interobserver, intraobserver, and test-retest reliability of tasks were moderate to good. Nearly all tasks showed significant age effects, whereas sex was significant only for stringing beads and hopping on one leg. INTERPRETATION: These results indicate that timed performance and ordinal scales of neuromotor tasks can be reliably measured in preschool children and are characterized by developmental change and high interindividual variability.
Resumo:
In this article we propose a novel method for calculating cardiac 3-D strain. The method requires the acquisition of myocardial short-axis (SA) slices only and produces the 3-D strain tensor at every point within every pair of slices. Three-dimensional displacement is calculated from SA slices using zHARP which is then used for calculating the local displacement gradient and thus the local strain tensor. There are three main advantages of this method. First, the 3-D strain tensor is calculated for every pixel without interpolation; this is unprecedented in cardiac MR imaging. Second, this method is fast, in part because there is no need to acquire long-axis (LA) slices. Third, the method is accurate because the 3-D displacement components are acquired simultaneously and therefore reduces motion artifacts without the need for registration. This article presents the theory of computing 3-D strain from two slices using zHARP, the imaging protocol, and both phantom and in-vivo validation.