997 resultados para nondestructive testing


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel design of 100GHz-spaced 16channel arrayed-waveguide grating (AWG) based on silica-on-silicon chip is reported.AWG is achieved by adding a Y-branch to the AWG and arranging the input/output channel in a neat row,so the whole configuration can be aligned and packaged using only one fiber-array.This configuration can decrease the device's size,enlarge the minimum radius of curvature,save time on polishing and alignment,and reduce the chip's fabrication cost.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The effect of thermal annealing on the Raman spectrum of Si0.33Ge0.67 alloy grown on Si (100) by molecular beam epitaxy is investigated in the temperature range of 550-800 degrees C. For annealing below 700 degrees C, interdiffusion at the interface is negligible and the residual strain plays the dominant role in the Raman shift. The strain-shift coefficients for Si-Ge and Ge-Ge phonon modes are determined to be 915 +/- 215 cm(-1) and 732 +/- 117 cm(-1), respectively. For higher temperature annealing, interdiffusion is significant and strongly affects the Raman shift and the spectral shape.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A semi-insulating (SI) GaAs single crystal ingot was successfully grown in a recoverable satellite. The two-dimensional distribution of stoichiometry in space-grown SI-GaAs single crystal wafer was studied nondestructively based upon x-ray Band diffraction. The avenge stoichiometry in the space-grown crystal is 0.50007 with mean square deviation of 6 x 10(-6), and shows a better stoichiametric property than the ground-grown SI-GaAs. The average etch pit density (EPD) of dislocations in the crystal revealed by molten KOH is 2.0 x 10(4) cm(-2), and the highest EPD is 3.1 x 10(4) cm(-2). This result indicates that the structural properly of the crystal is quite good.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Large area (25 mm(2)) silicon drift detectors and detector arrays (5x5) have been designed, simulated, and fabricated for X-ray spectroscopy. On the anode side, the hexagonal drift detector was designed with self-biasing spiral cathode rings (p(+)) of fixed resistance between rings and with a grounded guard anode to separate surface current from the anode current. Two designs have been used for the P-side: symmetric self-biasing spiral cathode rings (p(+)) and a uniform backside p(+) implant. Only 3 to 5 electrodes are needed to bias the detector plus an anode for signal collection. With graded electrical potential, a sub-nanoamper anode current, and a very small anode capacitance, an initial FWHM of 1.3 keV, without optimization of all parameters, has been obtained for 5.9 keV Fe-55 X-ray at RT using a uniform backside detector.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

IEECAS SKLLQG

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Charpy impact fracture behaviour of unnotched specimens of phenolphthalein polyether ketone (PEK-C) was studied over a temperature range from room temperature to 220 degrees C by using an instrumented impact tester. The load-time and energy-time curves of PEK-C at different temperatures were recorded. From these curves, some important parameters, such as the maximum impact load, the maximum stress, the total impact energy, the crack initiation energy, the crack propagation energy etc., were obtained and their temperature dependences of PEK-C were investigated. The point of 100 percent maximum load on the load-time trace was shown to be the yield point. Two parameters, the ductile ratio (D.R.) and the ductility index (D.I.) were applied to characterize the ductility of PEK-C and their relationships to the relaxation processes were discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A supported lanthanum gallate (LSGM) electrolyte thin-film solid oxide fuel cell with Ni-YSZ cermet anode and strontium-doped lanthanum manganite (LSM)-yttria stabilized zirconia (YSZ) composite cathode was, for the first time, fabricated and tested. The cell was prepared by an unconventional approach, in which an LSGM thin film (about 15 mum thick) was first deposited on a porous substrate such as a porous YSZ disk by a wet process and sintered at a high temperature (above 1400degrees C). NiO was then incorporated into the porous substrate by a carefully controlled impregnation process and fired at a much lower temperature. In this way, the severe reaction between LSGM and NiO at a high temperature, which is required for the full densification of LSGM film, can be avoided. A strontium-doped LaMnO3 (LSM)-YSZ composite cathode was screen printed on the surface of the LSGM film and then fired at 1250degrees C. The electrolyte resistances of the SOFC single cells fabricated by this approach are much lower compared to those of thick LSGM film supported cells. A maximum output power density of over 0.85 W/cm(2) at 800degreesC with H-2 as fuel and air as oxidant for a fabricated cell was achieved. (C) 2002 The Electrochemical Society.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this study, an in vitro multicellular tumor spheroid model was developed using microencapsulation, and the feasibility of using the microencapsulated. multicellular tumor spheroid (MMTS) to test the effect of chemotherapeutic drugs was investigated. Human MCF-7 breast cancer cells were encapsulated in alginate-poly-L-lysine-alginate (APA) microcapsules, and a single multicellular spheroid 150 mu m in diameter was formed in the microcapsule after 5 days of cultivation. The cell morphology, proliferation, and viability of the MMTS were characterized using phase contrast microscopy, BrdU-Iabeling, MTT stain, calcein AM/ED-2 stain, and H&E stain. It demonstrated that the MMTS was viable and that the proliferating cells were mainly localized to the periphery of the cell spheroid and the apoptotic cells were in the core. The MCF-7 MMTS was treated with mitomycin C (MC) at a concentration of 0.1, 1, or 10 times that of peak plasma concentration (ppc) for up to 72 h. The cytotoxicity was demonstrated. clearly by the reduction in cell spheroid size and the decrease in cell viability. The MMTS was further used to screen the anticancer effect of chemotherapeutic drugs, treated with MC, adriamycin (ADM) and 5-fluorouracil (5-FU) at concentrations of 0.1, 1, and 10 ppc for 24, 48, and 72 h. MCF-7 monolayer culture was used as control. Similar to monolayer culture, the cell viability of MMTS was reduced after treatment with anticancer drugs. However, the inhibition rate of cell viability in MMTS was much lower than that in monolayer culture. The MMTS was more resistant to anticancer drugs than monolayer culture. The inhibition rates of cell viability were 68.1%, 45.1%, and 46.8% in MMTS and 95.1%, 86.8%, and 91.6% in monolayer culture treated with MC, ADM, and 5-FU at 10 ppc for 72 h, respectively. MC showed the strongest cytotoxicity in both MMTS and monolayer, followed by 5-FU and ADM. It demonstrated that the MMTS has the potential to be a rapid and valid in vitro model to screen chemotherapeutic drugs with a feature to mimic in vivo three-dimensional (3-D) cell growth pattern.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BP (89-A-1204); Defense Advanced Research Projects Agency (90-0083); National Science Foundation (IRI-90-00530); Air Force Office of Scientific Research (90-0175, 90-0128); Army Research Office (DAAL-03-88-K0088)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cream liqueurs manufactured by a one-step process, where alcohol was added before homogenisation, were more stable than those processed by a two -step process which involved addition of alcohol after homogenisation. Using the one-step process, it was possible to produce creaming-stable liqueurs by using one pass through a homogeniser (27.6 MPa) equipped with "liquid whirl" valves. Test procedures to characterise cream liqueurs and to predict shelf life were studied in detail. A turbidity test proved simple, rapid and sensitive for characterising particle size and homogenisation efficiency. Prediction of age thickening/gelation in cream liqueurs during incubation at 45 °C depended on the age of the sample when incubated. Samples that gelled at 45 °C may not do so at ambient temperature. Commercial cream liqueurs were similar in gross chemical composition, and unlike experimentally produced liqueurs, these did not exhibit either age-gelation at ambient or elevated temperatures. Solutions of commercial sodium caseinates from different sources varied in their calcium sensitivity. When incorporated into cream liqueurs, caseinates influenced the rate of viscosity increase, coalescence and, possibly, gelation during incubated storage. Mild heat and alcohol treatment modified the properties of caseinate used to stabilise non-alcoholic emulsions, while the presence of alcohol in emulsions was important in preventing clustering of globules. The response to added trisodium citrate varied. In many cases, addition of the recommended level (0.18%) did not prevent gelation. Addition of small amounts of NaOH with 0.18 % trisodium citrate before homogenisation was beneficial. The stage at which citrate was added during processing was critical to the degree of viscosity increase (as opposed to gelation) in the product during 45 °C incubation. The component responsible for age-gelation was present in the milk-solids non fat portion of the cream and variations in the creams used were important in the age-gelation phenomenon Results indicated that, in addition to possibly Ca++, the micellar casein portion of serum may play a role in gelation. The role of the low molecular weight surfactants, sodium stearoyl lactylate and monodiglycerides in preventing gelation, was influenced by the presence of trisodium citrate. Clustering of fat globules and age-gelation were inhibited when 0.18 % citrate was included. Inclusion of sodium stearoyl lactylate, but not monodiglycerides, reduced the extent of viscosity increase at 45 °C in citrate containing liqueurs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Knowing one's HIV status is particularly important in the setting of recent tuberculosis (TB) exposure. Blood tests for assessment of tuberculosis infection, such as the QuantiFERON Gold in-tube test (QFT; Cellestis Limited, Carnegie, Victoria, Australia), offer the possibility of simultaneous screening for TB and HIV with a single blood draw. We performed a cross-sectional analysis of all contacts to a highly infectious TB case in a large meatpacking factory. Twenty-two percent were foreign-born and 73% were black. Contacts were tested with both tuberculin skin testing (TST) and QFT. HIV testing was offered on an opt-out basis. Persons with TST >or=10 mm, positive QFT, and/or positive HIV test were offered latent TB treatment. Three hundred twenty-six contacts were screened: TST results were available for 266 people and an additional 24 reported a prior positive TST for a total of 290 persons with any TST result (89.0%). Adequate QFT specimens were obtained for 312 (95.7%) of persons. Thirty-two persons had QFT results but did not return for TST reading. Twenty-two percent met the criteria for latent TB infection. Eighty-eight percent accepted HIV testing. Two (0.7%) were HIV seropositive; both individuals were already aware of their HIV status, but one had stopped care a year previously. None of the HIV-seropositive persons had latent TB, but all were offered latent TB treatment per standard guidelines. This demonstrates that opt-out HIV testing combined with QFT in a large TB contact investigation was feasible and useful. HIV testing was also widely accepted. Pairing QFT with opt-out HIV testing should be strongly considered when possible.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Optimally, expanded HIV testing programs should reduce barriers to testing while attracting new and high-risk testers. We assessed barriers to testing and HIV risk among clients participating in mobile voluntary counseling and testing (MVCT) campaigns in four rural villages in the Kilimanjaro Region of Tanzania. METHODS: Between December 2007 and April 2008, 878 MVCT participants and 506 randomly selected community residents who did not access MVCT were surveyed. Gender-specific logistic regression models were used to describe differences in socioeconomic characteristics, HIV exposure risk, testing histories, HIV related stigma, and attitudes toward testing between MVCT participants and community residents who did not access MVCT. Gender-specific logistic regression models were used to describe differences in socioeconomic characteristics, HIV exposure risk, testing histories, HIV related stigma, and attitudes toward testing, between the two groups. RESULTS: MVCT clients reported greater HIV exposure risk (OR 1.20 [1.04 to 1.38] for males; OR 1.11 [1.03 to 1.19] for females). Female MVCT clients were more likely to report low household expenditures (OR 1.47 [1.04 to 2.05]), male clients reported higher rates of unstable income sources (OR 1.99 [1.22 to 3.24]). First-time testers were more likely than non-testers to cite distance to testing sites as a reason for not having previously tested (OR 2.17 [1.05 to 4.48] for males; OR 5.95 [2.85 to 12.45] for females). HIV-related stigma, fears of testing or test disclosure, and not being able to leave work were strongly associated with non-participation in MVCT (ORs from 0.11 to 0.84). CONCLUSIONS: MVCT attracted clients with increased exposure risk and fewer economic resources; HIV related stigma and testing-related fears remained barriers to testing. MVCT did not disproportionately attract either first-time or frequent repeat testers. Educational campaigns to reduce stigma and fears of testing could improve the effectiveness of MVCT in attracting new and high-risk populations.