846 resultados para barium ferrite
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The purpose of this study was to evaluate the color stability of a maxillofacial elastomer with the addition of a nanoparticle pigment and/or an opacifier submitted to chemical disinfection and artificial aging. Specimens were divided into four groups (n = 30): group I: silicone without pigment or opacifier, group II: ceramic powder pigment, group III: Barium sulfate (BaSO(4)) opacifier, and group IV: ceramic powder and BaSO(4) opacifier. Specimens of each group (n = 10) were disinfected with effervescent tablets, neutral soap, or 4% chlorhexidine gluconate. Disinfection was done three times a week during two months. Afterward, specimens were submitted to different periods of artificial aging. Color evaluation was initially done, after 60 days (disinfection period) and after 252, 504, and 1008 h of artificial aging with aid of a reflection spectrophotometer. Data were analyzed by three-way ANOVA and Tukey test (alpha = 0.05). The isolated factor disinfection did not statistically influence the values of color stability among groups. The association between pigment and BaSO(4) opacifier (GIV) was more stable in relationship to color change (Delta E). All values of Delta E obtained, independent of the disinfectant and the period of artificial aging, were considered acceptable in agreement with the norms presented in literature. (C) 2011 Society of Photo-Optical Instrumentation Engineers (SPIE). [DOI: 10.1117/1.3625401]
Resumo:
Objective. The objective of this study was to evaluate the radiopacity of white Portland cement (PC) associated with bismuth oxide (Bi(2)O(3)), barium sulfate (BaSO(4)), iodoform (CHI(3)), and zirconium oxide (ZrO(2)). White mineral trioxide aggregate (WMTA) and PC without radiopacifier were used as positive and negative controls, respectively.Study design. Following International Organization for Standardization (ISO) 6876/2001, 5 circular specimens (10 x 1 mm) were made from each material. After the materials set, radiographs were taken using occlusal film and a graduated aluminum step-wedge varying in thickness from 2 to 16 mm. The dental X-ray unit (GE1000) was set at 50 Kvp, 10 mA, 18 pulses/s, and distance of 33.5 cm. The radiographs were digitized, and radiopacity was compared with the aluminum step-wedge, using Wixwin-2000 software (Gendex). Data (mm Al) were analyzed using analysis of variance and Tukey tests.Results. The PC + Bi(2)O(3) and WMTA samples presented greater radiopacity (5.88 and 5.72 mm Al, respectively), followed by PC + ZrO(2) (3.87 mm Al) and PC + CHI(3) (3.50 mm Al). The PC + BaSO(4) and PC samples presented the lowest radiopacity values (2.35 and 1.69 mm Al, respectively), which were below the minimum value recommended by the ISO.Conclusion. Analysis of the present results led to the conclusion that all of the materials tested presented acceptable radiopacity, except PC + BaSO(4) and pure PC. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2009; 108: 628-632)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
The present work reports the effects caused by barium on phase formation, morphology and sintering of lead magnesium niobate-lead titanate (PMN-50PT). Ab initio study of 0.5PbMg(1/3)Nb(2/3)O(3)-0.5Ba(x)Pb((1-x))TiO(3) ceramic powders, with x = 0, 0.20, and 0.40 was proposed, considering that the partial substitution of lead by barium can reestablish the equilibrium of monoclinic-tetragonal phases in the system. It was verified that even for 40 mol% of barium, it was possible to obtain pyrochlore-free PMN-PT powders. The increase of the lattice parameters of PMN-PT doped-powders confirmed dopant incorporation into the perovskite phase. The presence of barium improved the reactivity of the powders, with an average particle size of 120 nm for 40 mol% of barium against 167 mn for the pure sample. Although high barium content (40 mol%) was deleterious for a dense ceramic, contents up to 20 mol% allowed 95% density when sintered at 1100 degrees C for 4 h. (c) 2007 Elsevier Ltd. All rights reserved.
Resumo:
Pós de titanato zirconato de chumbo (PZT) puros e dopados com bário foram obtidos pelo método de precursores poliméricos, conformados uniaxialmente, na forma de cilindros, utilizando 15 MPa, e prensados isostaticamente à 210MPa. Com o objetivo de estudar o comportamento de sinterização os compactos foram divididos em dois lotes. Sendo um sinterizado em um forno acoplado a um dilatômetro até a temperatura de 1300 °C e o outro sinterizado em forno tipo mufla, em sistema fechado, na temperatura de 1100 °C por 4 horas. Verificou-se que a adição do íon bário influencia na cinética de sinterização, na densificação final, na microestrutura e nas propriedades elétricas da cerâmica. A adição de bário aumenta a concentração da fase tetragonal no PZT, em função da substituição do chumbo por bário na rede perovskita. As amostras dopadas com concentrações maiores que 5,0 mol % em bário apresentaram segregação de PbO no contorno de grão, inibindo seu crescimento.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The austenite decomposition in C-Mn steel containing boron was studied by continuous cooling from 1100 and 845 degreesC using the Jominy test. The results indicate that the different cooling speeds and the presence of boron refine and change the percentage of ferrite microstructure, martensite, and fine pearlite. (C) 2001 Elsevier B.V. B.V. All rights reserved.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
RACIONAL: Fato de observação não rara, é o encontro de refluxo cecoileal durante realização de enema opaco. As causas e conseqüências deste achado têm sido pouco estudadas. OBJETIVOS: Sabendo que a junção ileocecal exerce função de barreira e proteção contra a invasão do delgado pela flora colônica, realizou-se o presente estudo com a finalidade de investigar se existe contaminação ileal em indivíduos com refluxo cecoileal ao enema opaco. MÉTODOS: Investigaram-se 36 indivíduos, 30 mulheres e 6 homens, idade média de 54 anos, 25 com e 11 com ausência refluxo cecoileal. Todos submetidos a pesquisa de contaminação bacteriana do delgado por intermédio de teste respiratório com lactulose-H2 e a determinação do tempo de trânsito orocecal por meio de biossusceptometria de corrente alternada. A caracterização da contaminação do delgado foi baseada no encurtamento do tempo de trânsito orocecal medido pelo teste da lactulose-H2. RESULTADOS: A comparação dos valores basais do H2, do tempo de trânsito orocecal-H2 e tempo de trânsito orocecal-biossusceptometria de corrente alternada não diferiram estatisticamente entre os grupos com e sem refluxo cecoileal. Quando comparados os tempo de trânsito orocecal-H2 e tempo de trânsito orocecal-biossusceptometria, foi observado aumento de tendência de redução do primeiro em relação ao último nos grupos com refluxo cecoileal e correlação significante entre os dois métodos apenas no grupo-controle, inexistindo nos com refluxo cecoileal. CONCLUSÃO: Encurtamento do tempo de trânsito orocecal-H2 e sua perda de correlação com o tempo de trânsito orocecal-biossusceptometria observado em indivíduos com refluxo cecoileal, sugerem comportamento diferenciado deste grupo em relação ao grupo-controle. Possível explicação para as diferenças registradas entre os grupos, seria a presença de flora anômala nos indivíduos com refluxo cecoileal.
Resumo:
Avaliou-se a ação antiarrítmica do isofluorano em cães submetidos a arritmias ventriculares pelo uso de cloreto de bário, utilizando-se de seis cães, machos e fêmeas, que receberam uma dose de 3mg/kg de peso IV de cloreto de bário a 2,5% (G1). O mesmo protocolo foi repetido, nos mesmos animais, sob anestesia geral com isofluorano (G2). Usou-se a eletrocardiografia computadorizada para avaliar o ritmo cardíaco, a duração e/ou amplitude das ondas e os intervalos eletrocardiográficos. Não se verificou alteração no ritmo cardíaco em G2, diferente de G1, que apresentou freqüentes arritmias ventriculares na forma de bigeminismo e taquicardia ventricular multifocal. Houve diferença significativa entre os grupos em relação à freqüência cardíaca nos minutos iniciais de observação, quando ocorreu aumento na freqüência cardíaca em G1. A utilização do isofluorano conferiu ação antiarrítmica em cães com arritmias induzidas pelo cloreto de bário, reforçando suas indicações a pacientes com risco considerável de desenvolvimento de arritmias ventriculares.
Resumo:
Ferroelectric layefed-perovskite BaBi2Ta2O9 (BBT) has been prepared successfully by solid-state reaction. The influence of pressure and temperature/time annealing regime on the BBT phase formation was analyzed. The powders were characterized by thermal analysis and Xray diffraction and the sintered pellets by scanning electron microscopy. The crystalline BBT phase, free of secondary phases was obtained at 950 degreesC for 2 h. For an applied field strength of 380 kV/cm, a remnant polarization of 7.6 muC/cm(2) and an electric coercive field of 45.7 kV/cm were obtained. (C) 2004 Elsevier B.V. All rights reserved.