646 resultados para Transtibial prostheses
Resumo:
BACKGROUND The Journey bicruciate substituting (BCS) total knee replacement (TKR) is intended to improve knee kinematics by more closely approximating the surfaces of a normal knee. The purpose of this analysis was to address the safety of Journey BCS knees by studying early complication and revision rates in a consecutive case series. METHODS Between December 2006 and May 2011, a single surgeon implanted 226 Journey BCS total knee prostheses in 191 patients (124 women, 67 men) who were eligible for study. Mean age at surgery was 68 years (41-85 years).Outcome measures were early complications and minor and major revision rates. All complications were considered, irrespective of whether conservative treatment or revision was required. RESULTS The average implantation time was 3.5 years (range 1.3-5.8 years). Thirty-three complications (14.6% of 226 knees) required minor or major revision surgery in 25 patients. The remaining eight patients were treated conservatively. Sixteen minor revisions were performed in 12 patients. Thirteen major revisions were required in 13 patients, which results in a rate of 1.65 major revisions per 100 component years. The linear trend of the early complication rate by treatment year was not significant (p = .22).Multivariate logistic regression showed no significant predictors for the occurrence of a complication or for revision surgery. A tendency towards higher complication rates was observed in female patients, although it was not significant (p = .066). CONCLUSIONS The complication and revision rates of the Journey BCS knee implant are high in comparison with those reported for other established total knee systems. Caution is advised when using this implant, particularly for less experienced knee surgeons.
Resumo:
Aortic valve replacement (AVR) is the most frequently performed procedure in valve surgery. The controversy about the optimal choice of the prosthetic valve is as old as the technique itself. Currently there is no perfect valve substitute available. The main challenge is to choose between mechanical and biological prosthetic valves. Biological valves include pericardial (bovine, porcine or equine) and native porcine bioprostheses designed in stented or stentless versions. Homografts and pulmonary autografts are reserved for special indications and will not be discussed in detail in this review. We will focus on the decision making between artificial biological and mechanical prostheses, respectively. The first part of this article reviews guideline recommendations concerning the choice of aortic prostheses in different clinical situations while the second part is focused on novel strategies in the treatment of patients with aortic valve pathology.
Resumo:
Gebiet: Chirurgie Abstract: Objectives This study reports a series of pitfalls, premature failures and explantations of the third generation Freedom SOLO bovine pericardial stentless valve. – – Methods 149 patients underwent aortic valve replacement (AVR) using the FS. Follow-up was 100% complete with an average observation time of 5.5±2.3 years (max. 8.7 years) and a total of 825 patient years. Following intraoperative documentation, all explanted valve prostheses underwent histological examination. – – Results Freedom from structural valve deterioration (SVD) at 5, 6, 7, 8 and 9 years was 92%, 88%, 80% and 70% and 62%, respectively. 14 prostheses required explantation due to valve-independent dysfunction (n=5, i.e. thrombus formation, oversizing, aortic dilatation, endocarditis and suture dehiscence) or valve-dependent failure (acute leaflet tears, n=4, severe stenosis, n=5). Thus freedom from explantation at 5, 6, 7, 8 and 9 years was 95%, 94%, 91% and 81% and 72%, respectively. An acute vertical tear along the non-coronary/right-coronary commissure to the base occurred at a mean of 6.0 years [range 4.3?7.3 years] and affected size 25 and 27 prostheses exclusively. Four FS required explantation after a mean of 7.5 years [range 7.0?8.3 years] due to severe functional stenosis and gross calcification that included the entire aortic root. – – Conclusions The Freedom SOLO stentless valve is safe to implant and shows satisfying mid-term results in our single institution experience. Freedom from SVD and explantation decreased markedly after only 6 ? 7 years, so that patients with FS require close observation and follow-up. Exact sizing, symmetric positioning and observing patient limitations are crucial for optimal outcome.
Resumo:
This paper reviews the methods, benefits and challenges associated with the adoption and translation of computational fluid dynamics (CFD) modelling within cardiovascular medicine. CFD, a specialist area of mathematics and a branch of fluid mechanics, is used routinely in a diverse range of safety-critical engineering systems, which increasingly is being applied to the cardiovascular system. By facilitating rapid, economical, low-risk prototyping, CFD modelling has already revolutionised research and development of devices such as stents, valve prostheses, and ventricular assist devices. Combined with cardiovascular imaging, CFD simulation enables detailed characterisation of complex physiological pressure and flow fields and the computation of metrics which cannot be directly measured, for example, wall shear stress. CFD models are now being translated into clinical tools for physicians to use across the spectrum of coronary, valvular, congenital, myocardial and peripheral vascular diseases. CFD modelling is apposite for minimally-invasive patient assessment. Patient-specific (incorporating data unique to the individual) and multi-scale (combining models of different length- and time-scales) modelling enables individualised risk prediction and virtual treatment planning. This represents a significant departure from traditional dependence upon registry-based, population-averaged data. Model integration is progressively moving towards 'digital patient' or 'virtual physiological human' representations. When combined with population-scale numerical models, these models have the potential to reduce the cost, time and risk associated with clinical trials. The adoption of CFD modelling signals a new era in cardiovascular medicine. While potentially highly beneficial, a number of academic and commercial groups are addressing the associated methodological, regulatory, education- and service-related challenges.
Resumo:
OBJECTIVE The aim of this cross-sectional study was to estimate bone loss of implants with platform-switching design and analyze possible risk indicators after 5 years of loading in a multi-centered private practice network. METHOD AND MATERIALS Peri-implant bone loss was measured radiographically as the distance from the implant shoulder to the mesial and distal alveolar crest, respectively. Risk factor analysis for marginal bone loss included type of implant prosthetic treatment concept and dental status of the opposite arch. RESULTS A total of 316 implants in 98 study patients after 5 years of loading were examined. The overall mean value for radiographic bone loss was 1.02 mm (SD ± 1.25 mm, 95% CI 0.90- 1.14). Correlation analyses indicated a strong association of peri-implant bone loss > 2 mm for removable implant-retained prostheses with an odds ratio of 53.8. CONCLUSION The 5-year-results of the study show clinically acceptable values of mean bone loss after 5 years of loading. Implant-supported removable prostheses seem to be a strong co-factor for extensive bone level changes compared to fixed reconstructions. However, these results have to be considered for evaluation of the included special cohort under private dental office conditions.
Resumo:
Nowadays, many people retain their natural teeth until late in life as a result of the large success of preventive strategies. However, there is still a very high prevalence of edentulism especially in elderly patients and many of these patients are provided with inadequate dental prostheses. In addition, many elderly citizens suffer from systemic diseases leading to increased drug prescription with age. This may have direct or indirect negative effects on the health and integrity of oral tissues like teeth, mucosa or muscles. There is growing evidence that a close interaction between the general medical condition and oral health exists. From a dental point of view, the chewing ability and capacity and its interaction with the nutritional status seem to be especially important. For example, complete denture wearers present a significant oral disability, which often leads to a gradual deterioration of their individual dietary habits. The improvement of maximum bite force and chewing efficiency may be an important prerequisite for an adequate nutrition. Those functional parameters can often be improved by providing functional dental prostheses or by stabilizing complete dentures with endosseous implants. Nevertheless, an improvement of the nutritional status can only be achieved through a close collaboration with dieticians or clinical nutritionists.
Resumo:
OBJECTIVE To compare the precision of fit of long-span vs. short-span implant-supported screw-retained fixed dental prostheses (FDPs) made from computer-aided-design/computer-aided-manufactured (CAD/CAM) titanium and veneered with ceramic. The null hypothesis was that there is no difference in the vertical microgap between long-span and short-span FDPs. MATERIALS AND METHODS CAD/CAM titanium frameworks for an implant-supported maxillary FDP on implants with a flat platform were fabricated on one single master cast. Group A consisted of six 10-unit FDPs connected to six implants (FDI positions 15, 13, 11, 21, 23, 25) and group B of six 5-unit FDPs (three implants, FDI positions 21, 23, 25). The CAD/CAM system from Biodenta Swiss AG (Berneck, Switzerland) was used for digitizing (laser scanner) the master cast and anatomical CAD of each framework separately. The frameworks were milled (CAM) from a titanium grade V monobloc and veneered with porcelain. Median vertical distance between implant and FDP platforms from the non-tightened implants (one-screw test on implant 25) was calculated from mesial, buccal, and distal scanning electron microscope measurements. RESULTS All measurements showed values <40 μm. Total median vertical microgaps were 23 μm (range 2-38 μm) for group A and 7 μm (4-24 μm) for group B. The difference between the groups was statistically significant at implant 21 (P = 0.002; 97.5% CI -27.3 to -4.9) and insignificant at implant 23 (P = 0.093; -3.9 to 1.0). CONCLUSIONS CAD/CAM fabrication including laboratory scanning and porcelain firing was highly precise and reproducible for all long- and short-span FDPs. While all FDPs showed clinically acceptable values, the short-span FDPs were statistically more precise at the 5-unit span distance.
Resumo:
Heart valve prostheses are used to replace native heart valves which that are damaged because of congenital diseases or due to ageing. Biological prostheses made of bovine pericardium are similar to native valves and do not require any anticoagulation treatment, but are less durable than mechanical prostheses and usually fail by tearing. Researches are oriented in improving the resistance and durability of biological heart valve prostheses in order to increase their life expectancy. To understand the mechanical behaviour of bovine pericardium and relate it to its microstructure (mainly collagen fibres concentration and orientation) uniaxial tensile tests have been performed on a model material made of collagen fibres. Small Angle Light Scattering (SALS) has been also used to characterize the microstructure without damaging the material. Results with the model material allowed us to obtain the orientation of the fibres, relating the microstructure to mechanical performance
Resumo:
A recent application of computer simulation is its use for the human body, which resembles a mechanism that is complemented by torques in the joints that are caused by the action of muscles and tendons. Among others, the application can be used to provide training in surgical procedures or to learn how the body works. Some of the other applications are to make a biped walk upright, to build robots that are designed on the human body or to make prostheses or robot arms to perform specific tasks. One of the uses of simulation is to optimise the movement of the human body by examining which muscles are activated and which should or should not be activated in order to improve a person?s movements. This work presents a model of the elbow joint, and by analysing the constraint equations using classic methods we go on to model the bones, muscles and tendons as well as the logic linked to the force developed by them when faced with a specific movement. To do this, we analyse the reference bibliography and the software available to perform the validation.
Resumo:
Os implantes mamários de silicone têm sido empregados, tanto nas cirurgias de aumento das mamas, quanto na reconstrução do tecido mamário após mastectomia. A segurança biológica dos implantes de silicone merece estudo relacionado aos processos de esterilização empregados, pois podem constituir-se em fator de comprometimento da estrutura química do polímero e, conseqüentemente, da biocompatibilidade. Este estudo consistiu na avaliação da biocompatibilidade de implantes mamários de silicone após terem sido submetidos aos processos de esterilização por calor seco, radiação gama e óxido de etileno. O parâmetro avaliado foi a viabilidade celular, empregando o método de difusão em agar e de captura do vermelho neutro. As amostras compreenderam implantes de silicone gel lisos, texturizados e revestidos com poliuretano e implantes texturizados pré-cheios com solução salina. Também foi realizado o teste de endotoxinas bacterianas pelo método do LAL e determinação da taxa de migração do gel de silicone (teste de bleed). Os três métodos de esterilização mostraram-se igualmente eficientes pela comprovação da condição de esterilidade dos implantes através de metodologia descrita na Farmacopéia Americana 27 edição. Os níveis de endotoxinas bacterianas dos implantes, também atenderam aos requisitos dos compêndios oficiais. Na avaliação da biocompatibilidade todos os implantes, independente dos processos de esterilização utilizados, apresentaram ausência de citotoxicidade. Os resultados do teste de bleed mostraram uma maior taxa de migração de gel para os implantes de superfície lisa em comparação com os implantes de superfície texturizada e revestida com poliuretano, quando esterilizados por calor seco. Ao comparar a taxa de migração do gel para os implantes de superfície lisa esterilizados por calor seco e óxido de etileno, obteve-se uma maior taxa de migração para aqueles implantes esterilizados por óxido de etileno. As diferentes avaliações realizadas neste estudo abrangeram aspectos biológicos, químicos e físicos relevantes para garantir um produto de boa qualidade e que, por assegurar a manutenção da característica de biocompatibilidade, resulta na segurança biológica deste tipo de implante.
Resumo:
INTRODUÇÃO: A prótese biliar endoscópica é aceita em todo o mundo como a primeira escolha de tratamento paliativo na obstrução biliar maligna. Atualmente ainda persistem dois tipos de materiais utilizados em sua confecção: plástico e metal. Consequentemente, muitas dúvidas surgem quanto a qual deles é o mais benéfico para o paciente. Esta revisão reúne as informações disponíveis da mais alta qualidade sobre estes dois tipos de prótese, fornecendo informações em relação à disfunção, complicação, taxas de reintervenção, custos, sobrevida e tempo de permeabilidade; e pretende ajudar a lidar com a prática clínica nos dias de hoje. OBJETIVO: Analisar, através de metanálise, os benefícios de dois tipos de próteses na obstrução biliar maligna inoperável. MÉTODOS: Uma revisão sistemática de ensaios clínicos randomizados (RCT) foi conduzida, com a última atualização em março de 2015, utilizando EMBASE, CINAHL (EBSCO), Medline, Lilacs / Centro (BVS), Scopus, o CAPES (Brasil), e literatura cinzenta. As informações dos estudos selecionados foram extraídas tendo em vista seis desfechos: primariamente disfunção, taxas de reintervenção e complicações; e, secundariamente, custos, sobrevivência e tempo de permeabilidade. Os dados sobre as características dos participantes do RCT, critérios de inclusão e exclusão e tipos de próteses também foram extraídos. Os vieses foram avaliados principalmente através da escala de Jadad. Esta metanálise foi registrada no banco de dados PROSPERO pelo número CRD42014015078. A análise do risco absoluto dos resultados foi realizada utilizando o software RevMan 5, calculando as diferenças de risco (RD) de variáveis dicotômicas e média das diferenças (MD) de variáveis contínuas. Os dados sobre a RD e MD para cada desfecho primário foram calculados utilizando o teste de Mantel-Haenszel e a inconsistência foi avaliada com o teste Qui-quadrado (Chi2) e o método de Higgins (I2). A análise de sensibilidade foi realizada com a retirada de estudos discrepantes e a utilização do efeito aleatório. O teste t de Student foi utilizado para a comparação das médias aritméticas ponderadas, em relação aos desfechos secundários. RESULTADOS: Inicialmente foram identificados 3660 estudos; 3539 foram excluídos por título ou resumo, enquanto 121 estudos foram totalmente avaliados e foram excluídos, principalmente por não comparar próteses metálicas (SEMS) e próteses plásticas (PS), levando a treze RCT selecionados e 1133 indivíduos metanálise. A média de idade foi de 69,5 anos, e o câncer mais comum foi de via biliar (proximal) e pancreático (distal). O diâmetro de SEMS mais utilizado foi de 10 mm (30 Fr) e o diâmetro de PS mais utilizado foi de 10 Fr. Na metanálise, SEMS tiveram menor disfunção global em comparação com PS (21,6% versus 46,8% p < 0,00001) e menos reintervenções (21,6% versus 56,6% p < 0,00001), sem diferença nas complicações (13,7% versus 15,9% p = 0,16). Na análise secundária, a taxa média de sobrevida foi maior no grupo SEMS (182 contra 150 dias - p < 0,0001), com um período maior de permeabilidade (250 contra 124 dias - p < 0,0001) e um custo semelhante por paciente, embora menor no grupo SEMS (4.193,98 contra 4.728,65 Euros - p < 0,0985). CONCLUSÃO: SEMS estão associados com menor disfunção, menores taxas de reintervenção, melhor sobrevida e maior tempo de permeabilidade. Complicações e custos não apresentaram diferença
Resumo:
Objetivo: Conocer los hábitos higiénicos en el colectivo de pacientes durante su estancia en el Hospital de la Magdalena de Castellón e identificar patologías causadas por posibles hábitos higiénicos bucodentales inadecuados. Metodología: Se trata de un estudio descriptivo transversal observacional basado en datos de registro e información de pacientes y cuidadores principales. Se seleccionó una muestra de 50 pacientes en el Hospital de la Magdalena de Castellón hospitalizados. Se realizó un examen odontológico a partir de datos recogidos en un registro diseñado para tal fin. Se usó el índice de LÖE y SILNESS y el índice VIGILD M. Para evaluar la satisfacción se utiliza el test GOHAI. El análisis de los datos se realiza con el programa estadístico R, en el cual saldrán los porcentajes de las patologías BD y hábitos de higiene diarios de los pacientes hospitalizados. Resultados: La edad media de los pacientes estudiados es de 68 años; la mayoría hombres (70%). Observamos en nuestro estudio que las mujeres no fuman y que sus hábitos higiénicos, patologías encontradas son mejores que en los hombres. Sin embargo un 100% de los pacientes estudiados necesitan atención bucodental. Conclusiones: En este estudio se observan problemas de higiene bucodental en los pacientes hospitalizados en un centro de larga estancia de Castellón.
Resumo:
Este projeto tem o seu enquadramento no âmbito da biomecânica desportiva, aplicada ao ciclismo adaptado. Numa linha de apoio a um ciclista amputado transtibial, atleta da Seleção Nacional de ciclismo adaptado, foi desenvolvido um dispositivo de apoio para a prática da modalidade na classe C2 da União Ciclista Internacional, que consiste em pedalar com uma só perna. O protótipo do dispositivo foi desenvolvido em material compósito, otimizado com vista à redução da sua massa, testado em ambiente laboratorial e experimentado em contexto real. A disponibilização deste dispositivo ao atleta será seguramente uma mais-valia e um passo importante com vista à sua representação de Portugal nos Jogos Para-Olímpicos de 2016.
Resumo:
Mode of access: Internet.
Resumo:
"History of fixed partial prostheses, by Claude Rowe Baker": p. 1-14.