618 resultados para Tanque séptico


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The purpose of this systematic review was to compare the effectiveness of topical treatments to minimize post-radiotherapy xerostomia. PubMed, Cochrane Library (CENTRAL) and LILACS databases were searched without restriction on date or language until the 6thAugust, 2015. Key-wordsused for searching were radiotherapy, xerostomia and saliva. Two independent reviewers screened titles and abstracts, carried out data extraction and assessed risk of bias. The first search identified 429 articles. From these, 117 studies were selected for full-text reading, from which 18 were included in the qualitative synthesis. From the eighteen articles included, seven were non- controlled clinical trial, one article was controlled clinical trial and ten studies were randomized clinical trials (three clinical trials were placebo controlled and seven were crossover). By the assessment of the quality of the studies included, ten showed high risk of bias, four showed moderate risk of bias and four presented low risk of bias. All interventions were considered effective in treating xerostomia (mucin, polysaccharides, aloe vera, rape oil, linseed oil, carboxymethylcellulose, polyethylene oxide, pilocarpine and systems of care for xerostomia - gel, paste and mouthwash). Meta-analysis could not be performed due to heterogeneity between thestudiesand interventions. This systematic review showed that a single and general protocol for topical treatment of xerostomia post-radiotherapy does not exist and that follow-up visits should be performed to validate the individualized treatment plan.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Este estágio foi desenvolvido na Águas do Oeste, no período compreendido entre outubro de 2013 e julho de 2014, tendo como objetivo a otimização energética dos sistemas de arejamento e agitação. A importância deste tema deve-se ao fato de estes sistemas serem responsáveis por cerca de 70% do consumo de uma ETAR. Identificaram-se possíveis equipamentos a intervencionar e através de pesquisa bibliográfica e consulta de experts possíveis soluções em termos de eficiência energética, sendo apresentado neste relatório um resumo das soluções identificadas. Neste estudo foram avaliados vários casos de estudo em ETAR que servem como base para muitas outras da concessão da Águas do Oeste. Nestas ETAR foram testadas algumas das soluções identificadas. Desta análise conclui-se que tanto a agitação como o arejamento efetuado na maioria das ETAR é inflexível a variações de carga e/ou excessivo existindo assim oportunidades de otimização tanto na diminuição de equipamentos por tanque como no corte de potência de arejamento e de agitação e na limpeza dos difusores, é muito importante para repor a eficiência de transferência dos mesmos em condições muito semelhantes às de origem (deve ser efetuada regularmente num período que dependerá de ETAR para ETAR). A etapa de desidratação na ETAR da Atouguia da Baleia pode com pequenas alterações ser efetuada sem acompanhamento, ou seja em períodos noturnos, podendo-se assim reduzir o tempo de funcionamento do agitador e arejador do tanque de lamas que atualmente funcionam em contínuo. Concluiu-se ainda que a otimização dos sistemas de arejamento e agitação é uma área onde existe um longo caminho a percorrer, onde há muito por testar e aplicar e que muitas vezes também passa por mudança de perceções da realidade e comportamentos.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Três grupos constituídos por indivíduos de tilápia da espécie Oreochromis mossambicus foram observados por um período de 6 meses e registado os seus comportamentos reprodutivos, número de fêmeas em incubação e o número de fry que nasceram durante este tempo. Cada grupo apresentava proporções sexuais distintas (macho:fêmea), nomeadamente, 1:3, 1:4 e 2:2. Após a evolução do estágio das fry a alevins, foram testados nestes indivíduos 3 dietas experimentais: a dieta RT (ração para tilápia), a dieta RD (dieta para douradas) e a Mix (uma mistura de 50% de cada uma das rações anteriormente referidas). Os alevins foram distribuídos em 9 tanques, 20 indivíduos/tanque, existindo três réplicas por dieta e todos se encontravam a uma temperatura de 28 ± 1ºC. Foram alimentados 3 vezes por dia durante 11 semanas, fazendo jejum 1 dia por semana. A cada 2 semanas, os indivíduos eram pesados e medidos e a quantidade de ração era ajustada de acordo com o seu crescimento. Como forma de se reduzir o stress neste procedimento de medição e pesagem, utilizaram-se três anestésicos a diferentes concentrações: MS-222 (0,15, 0,25 e 0,35ml L-1), óleo de cravo (0,10, 0,15 e 1,2ml L-1) e 2-fenoxietanol (0,40, 0,60, 0,80 e 1,00ml L-1). Registaram-se os tempos de indução e recuperação e avaliou-se qual o anestésico mais eficaz. No final do ensaio, os indivíduos foram mortos por choque térmico, filetados e sujeitados a estudos para avaliação do teor de proteína, lípidos, humidade e cinzas. No final de todo este trabalho experimental verificou-se que existiu reprodução nos Grupos 1 e 2 durante os 6 meses e que a melhor proporção sexual é 1:3 (macho:fêmea). Observou-se que as fêmeas que produzem mais posturas seguidas têm um menor número de fry por postura e as que fazem um maior intervalo de tempo entre cada postura, produzem posturas com um maior número de fry. Para qualquer uma destas opções das fêmeas, a taxa de mortalidade das fry é muito reduzida. No ensaio das dietas, os alevins aceitaram com boa aceitabilidade as três dietas mas com o decorrer do tempo, os indivíduos da dieta RD começaram a ganhar hemorragias em algumas partes do corpo. Não existiram diferenças significativas entre as dietas. A dieta Mix foi a que mostrou melhores resultados finais com um peso e comprimento máximos de 4,51 ± 3,39g e 3,36 ± 1,81cm, respetivamente. Para os valores de WG, SGR e FCR também não existiram diferenças significativas para as três iv dietas, sendo a dieta Mix a obter os valores máximos para WG (4,71g) e SGR (2,97% dia-1) mas com o FCR baixo (12,45 g/g). Para os resultados da composição química obtiveram-se diferenças estatisticamente significativas (P < 0,05) nos dados da proteína e humidade. A dieta RT foi a que apresentou um maior teor de proteína (18,53%) e os valores máximos para a humidade foram nas dietas RT (80.54%) e Mix (80,57%). Os lípidos e as cinzas não tiveram diferenças significativas e os valores máximos para estes dois parâmetros foram 1,38% e 1,50% na RT, respetivamente. Para os anestésicos estudados existiram diferenças significativas (P < 0,05) para os tempos de anestesia e recuperação pertencentes ao MS-222 e 2-fenoxietanol; o óleo de cravo apenas apresentou diferenças significativas no tempo de indução. As concentrações que mais eficazes se mostraram para anestesiar Tilápias Moçambicanas foram: 0,25ml L-1 para o MS-222, 0,10ml L-1 para o óleo de cravo e 0,80ml L-1 e 1,00ml L-1 para o 2-fenoxietanol. Os resultados deste trabalho sugerem que a reprodução de Tilápia Moçambicana se consegue com bastante sucesso quando se proporcionam condições ótimas, principalmente, a temperatura que é um dos fatores mais importantes; é uma espécie que aceita com facilidade variados tipos de rações; e os anestésicos utilizados mostraram-se eficazes a anestesiar os juvenis desta espécie apesar de ser necessário continuar o estudo com mais concentrações.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Procedimiento y dispositivo para el tratamiento integrado de residuos vegetales procedentes de explotaciones agrícolas y de las aguas residuales originadas. Procedimiento y dispositivo para el tratamiento de residuos vegetales en el que un volumen de residuos se somete a un proceso que integra las siguientes operaciones: (i) cortado mediante cizalla, (ii) homogeneizado mediante vibración, (iii) lavado con surfactantes en cilindro rotatorio, (iv) secado en cinta continua mediante chorro de aire caliente, y (v) secado opcional en tanque giratorio provisto de chorro de aire caliente, en caso de ser necesario reducir la humedad, originándose finalmente un residuo estable, de menor volumen que el inicial apto para uso industrial, y una corriente de aguas de lavado con una elevada concentración de pesticidas, microorganismos, surfactantes y partículas. La corriente de aguas de lavado se filtran y se llevan a un tanque-reactor que por tratamiento oxidativo con ozono y agua oxigenada mineraliza loscontaminantes presentes permitiendo su reutilización.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Se basa en el control del pH de la suspensión coloidal, modificándolo de tal manera que se alcance el punto isoeléctrico que es característico de cada tipo de partícula en presencia de un determinado electrolito. Una vez terminado el tratamiento de fotocatálisis se almacena la suspensión coloidal en un tanque y tras homogeneizar la misma mediante agitadores convencionales se toma una muestra representativa del volumen total y se añade una base o un ácido a la misma hasta conseguir el punto de carga eléctrica nula de la muestra. A continuación se añade al tanque de almacenamiento la cantidad adecuada de base o de ácido, extrapolada de la etapa anterior, con lo que se conseguirá el punto de carga eléctrica nula del volumen almacenado en el tanque. Finalmente se retira el sobrenadante limpio, una vez que se ha producido la sedimentación del catalizador en el fondo del tanque de almacenamiento.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Abastecimiento de Agua Potable para la parroquia Checa información general; lugar geográfico, geología, crecimiento de la comunidad, levantamiento topográfico, análisis de aguas y tratamiento de la misma, análisis poblacional, consumo y demanda de agua en la zona, obras de captación, aducción, conducción, distribución y el cálculo de la red por el Método de Hardy Cross, finalmente tenemos desinfección, tanque de reserva y el diseño del acueducto sobre la Quebrada Dispan

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Os oceanos representam um dos maiores recursos naturais, possuindo expressivo potencial energético, podendo suprir parte da demanda energética mundial. Nas últimas décadas, alguns dispositivos destinados à conversão da energia das ondas dos oceanos em energia elétrica têm sido estudados. No presente trabalho, o princípio de funcionamento do conversor do tipo Coluna de Água Oscilante, do inglês Oscillating Water Colum, (OWC) foi analisado numericamente. As ondas incidentes na câmara hidro-pneumática da OWC, causam um movimento alternado da coluna de água no interior da câmara, o qual produz um fluxo alternado de ar que passa pela chaminé. O ar passa e aciona uma turbina a qual transmite energia para um gerador elétrico. O objetivo do presente estudo foi investigar a influência de diferentes formas geométricas da câmara sobre o fluxo resultante de ar que passa pela turbina, que influencia no desempenho do dispositivo. Para isso, geometrias diferentes para o conversor foram analisadas empregando modelos computacionais 2D e 3D. Um modelo computacional desenvolvido nos softwares GAMBIT e FLUENT foi utilizado, em que o conversor OWC foi acoplado a um tanque de ondas. O método Volume of Fluid (VOF) e a teoria de 2ª ordem Stokes foram utilizados para gerar ondas regulares, permitindo uma interação mais realista entre o conversor, água, ar e OWC. O Método dos Volumes Finitos (MVF) foi utilizado para a discretização das equações governantes. Neste trabalho o Contructal Design (baseado na Teoria Constructal) foi aplicado pela primeira vez em estudos numéricos tridimensionais de OWC para fim de encontrar uma geometria que mais favorece o desempenho do dispositivo. A função objetivo foi a maximização da vazão mássica de ar que passa através da chaminé do dispositivo OWC, analisado através do método mínimos quadrados, do inglês Root Mean Square (RMS). Os resultados indicaram que a forma geométrica da câmara influencia na transformação da energia das ondas em energia elétrica. As geometrias das câmaras analisadas que apresentaram maior área da face de incidência das ondas (sendo altura constante), apresentaram também maior desempenho do conversor OWC. A melhor geometria, entre os casos desse estudo, ofereceu um ganho no desempenho do dispositivo em torno de 30% maior.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The PhD project addresses the potential of using concentrating solar power (CSP) plants as a viable alternative energy producing system in Libya. Exergetic, energetic, economic and environmental analyses are carried out for a particular type of CSP plants. The study, although it aims a particular type of CSP plant – 50 MW parabolic trough-CSP plant, it is sufficiently general to be applied to other configurations. The novelty of the study, in addition to modeling and analyzing the selected configuration, lies in the use of a state-of-the-art exergetic analysis combined with the Life Cycle Assessment (LCA). The modeling and simulation of the plant is carried out in chapter three and they are conducted into two parts, namely: power cycle and solar field. The computer model developed for the analysis of the plant is based on algebraic equations describing the power cycle and the solar field. The model was solved using the Engineering Equation Solver (EES) software; and is designed to define the properties at each state point of the plant and then, sequentially, to determine energy, efficiency and irreversibility for each component. The developed model has the potential of using in the preliminary design of CSPs and, in particular, for the configuration of the solar field based on existing commercial plants. Moreover, it has the ability of analyzing the energetic, economic and environmental feasibility of using CSPs in different regions of the world, which is illustrated for the Libyan region in this study. The overall feasibility scenario is completed through an hourly analysis on an annual basis in chapter Four. This analysis allows the comparison of different systems and, eventually, a particular selection, and it includes both the economic and energetic components using the “greenius” software. The analysis also examined the impact of project financing and incentives on the cost of energy. The main technological finding of this analysis is higher performance and lower levelized cost of electricity (LCE) for Libya as compared to Southern Europe (Spain). Therefore, Libya has the potential of becoming attractive for the establishment of CSPs in its territory and, in this way, to facilitate the target of several European initiatives that aim to import electricity generated by renewable sources from North African and Middle East countries. The analysis is presented a brief review of the current cost of energy and the potential of reducing the cost from parabolic trough- CSP plant. Exergetic and environmental life cycle assessment analyses are conducted for the selected plant in chapter Five; the objectives are 1) to assess the environmental impact and cost, in terms of exergy of the life cycle of the plant; 2) to find out the points of weakness in terms of irreversibility of the process; and 3) to verify whether solar power plants can reduce environmental impact and the cost of electricity generation by comparing them with fossil fuel plants, in particular, Natural Gas Combined Cycle (NGCC) plant and oil thermal power plant. The analysis also targets a thermoeconomic analysis using the specific exergy costing (SPECO) method to evaluate the level of the cost caused by exergy destruction. The main technological findings are that the most important contribution impact lies with the solar field, which reports a value of 79%; and the materials with the vi highest impact are: steel (47%), molten salt (25%) and synthetic oil (21%). The “Human Health” damage category presents the highest impact (69%) followed by the “Resource” damage category (24%). In addition, the highest exergy demand is linked to the steel (47%); and there is a considerable exergetic demand related to the molten salt and synthetic oil with values of 25% and 19%, respectively. Finally, in the comparison with fossil fuel power plants (NGCC and Oil), the CSP plant presents the lowest environmental impact, while the worst environmental performance is reported to the oil power plant followed by NGCC plant. The solar field presents the largest value of cost rate, where the boiler is a component with the highest cost rate among the power cycle components. The thermal storage allows the CSP plants to overcome solar irradiation transients, to respond to electricity demand independent of weather conditions, and to extend electricity production beyond the availability of daylight. Numerical analysis of the thermal transient response of a thermocline storage tank is carried out for the charging phase. The system of equations describing the numerical model is solved by using time-implicit and space-backward finite differences and which encoded within the Matlab environment. The analysis presented the following findings: the predictions agree well with the experiments for the time evolution of the thermocline region, particularly for the regions away from the top-inlet. The deviations observed in the near-region of the inlet are most likely due to the high-level of turbulence in this region due to the localized level of mixing resulting; a simple analytical model to take into consideration this increased turbulence level was developed and it leads to some improvement of the predictions; this approach requires practically no additional computational effort and it relates the effective thermal diffusivity to the mean effective velocity of the fluid at each particular height of the system. Altogether the study indicates that the selected parabolic trough-CSP plant has the edge over alternative competing technologies for locations where DNI is high and where land usage is not an issue, such as the shoreline of Libya.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to test the sediment preference of L. vannamei shrimp. It was observed shrimp visit frequency, swimming and burying behaviour at different sediment compositions for 24h. Juvenile (0.93 ± 0.29g) and sub-adult shrimps (10.0 ± 1.18g) were obtained from the aquaculture station at Universidade Federal Rural do Semi-Árido UFERSA, and held in a plastic tank (water volume 500 L) supplied with aerated water and kept at constant temperature, pH, and salinity. Shrimp was fed by commercial shrimp dry food. The experimental substrates were composed by A: medium sand + thick sand + very thick sand + gravel; B: very fine sand + fine sand; and C: silt + clay. Thus, six different substrate combinations were tested: A, B, C, A+B, A+C, B+C. To test preference, it was used a cylindrical tank (40 l) divided into six differently substrate compartments. A single shrimp was introduced each tank and the frequency at which this shrimp visited each compartment was recorded over a 24h study period. It was tested 54 shrimp (18 sub-adult males, 18 subadult females and 18 juveniles). For each trial, sediment and water were changed to avoid pheromones and residues influence. Shrimp were weighted and sub-adults were divided by sex: males present petasma and females present thelycum. Data were collected on the experimental day at 19:30; 20:30; 00:30; 1:30; 05:30; 06:30; 13:30 and 14:30 h. At each time point, shrimp were observed for 20-min periods, in which we noted down which compartment the shrimp was occupying at 2-min intervals. Thus, for each period we had eleven observations (88 observations per day). For observations at night, it was used dim red light that did not affect shrimp behaviour. At each 20-min period, it was observed visit frequency in each substrate, if shrimp was burred or not or if it was swimming. There was not significant difference between light and dark burry activity for females. Swimming activity was significantly higher at night, mainly at 00:30 and 01:30 h. All L. vannamei shrimp showed preference for sediment B. This animal presents cyclic activity, spends the day light period buried and swims at night

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A Refinaria de Matosinhos é um dos complexos industriais da Galp Energia. A sua estação de tratamento de águas residuais industriais (ETARI) – designada internamente por Unidade 7000 – é composta por quatro tratamentos: o pré-tratamento, o tratamento físico-químico, o tratamento biológico e o pós-tratamento. Dada a interligação existente, é fundamental a otimização de cada um dos tratamentos. Este trabalho teve como objetivos a identificação dos problemas e/ou possibilidades de melhoria do pré-tratamento, tratamento físico-químico e pós-tratamento e principalmente a otimização do tratamento biológico da ETARI. No pré-tratamento verificou-se que a separação de óleos e lamas não era eficaz uma vez que se formam emulsões destas duas fases. Como solução, sugeriu-se a adição de agentes desemulsionantes, que se revelou economicamente inviável. Assim, sugeriu-se como alternativa o recurso a técnicas de tratamento da emulsão gerada, tais como a extração com solvente, centrifugação, ultrassons e micro-ondas. No tratamento físico-químico constatou-se que o controlo da unidade de saturação de ar na água era feito com base na análise visual dos operadores, o que pode conduzir a condições de operação afastadas das ótimas para este tratamento. Assim, sugeriu-se a realização de um estudo de otimização desta unidade com vista à determinação da razão ar/sólidos ótima para este efluente. Para além disto, constatou-se, ainda, que os consumos de coagulante aumentaram cerca de -- % no último ano, pelo que foi sugerido o estudo da viabilidade do processo de eletrocoagulação como substituto do sistema de coagulação existente. No pós-tratamento identificou-se o processo de lavagem dos filtros como sendo a etapa com possibilidade de ser otimizada. Através de um estudo preliminar concluiu-se que a lavagem contínua de um filtro por cada turno melhorava o desempenho dos mesmos. Constatou-se, ainda, que a introdução de ar comprimido na água de lavagem promove uma maior remoção de detritos do leito de areia, no entanto esta prática parece influenciar negativamente o desempenho dos filtros. No caso do tratamento biológico, identificaram-se problemas ao nível do tempo de retenção hidráulico do tratamento biológico II, que apresentou elevada variabilidade. Apesar de identificado concluiu-se que este problema era de difícil solução. Verificou-se, também, que o oxigénio dissolvido não era monitorizado, pelo que se sugeriu a instalação de uma sonda de oxigénio dissolvido numa zona de baixa turbulência do tanque de arejamento. Concluiu-se que o oxigénio era distribuído de forma homogénea por todo o tanque de arejamento e tentou-se identificar quais os fatores que influenciariam este parâmetro, no entanto, dada a elevada variabilidade do efluente e das condições de tratamento, tal não foi possível. Constatou-se, também, que o doseamento de fosfato para o tratamento biológico II era pouco eficiente já Otimização dos sistemas biológicos e melhorias nos tratamentos da ETARI da Refinaria de Matosinhos que em -- % dos dias se verificaram níveis baixos de fosfato no licor misto (< - mg/L). Foi, por isso, proposta a alteração do atual sistema de doseamento por gravidade para um sistema de bomba doseadora. Para além disso verificou-se que os consumos deste nutriente aumentaram significativamente no último ano (cerca de --%), situação que se constatou estar relacionada com um aumento da população microbiana para este período. Foi possível relacionar-se o aparecimento frequente de lamas à superfície dos decantadores secundários com incrementos repentinos de condutividade, pelo que se sugeriu o armazenamento do efluente nas bacias de tempestade, nestas situações. Verificou-se que a remoção de azoto era praticamente ineficaz uma vez que a conversão de azoto amoniacal em nitratos foi muito baixa. Assim, sugeriu-se o recurso à técnica de bio-augmentação ou a transformação do sistema de lamas ativadas num sistema bietápico. Por fim, constatou-se que a temperatura do efluente à entrada da ETARI apresenta valores bastante elevados para o tratamento biológico (aproximadamente de --º C) pelo que se sugeriu a instalação de uma sonda de temperatura no tanque de arejamento de modo a controlar de forma mais eficaz a temperatura do licor misto. Ainda no que diz respeito ao tratamento biológico, foi possível desenvolver-se um conjunto de ferramentas que visaram o funcionamento otimizado deste tratamento. Nesse sentido, foram apresentadas várias sugestões de melhoria: a utilização do índice volumétrico de lamas como indicador da qualidade das lamas em alternativa à percentagem de lamas; foi desenvolvido um conjunto de fluxogramas para a orientação dos operadores de exterior na resolução de problemas; foi criada uma “janela de operação” que pretende ser um guia de apoio à operação; foi ainda proposta a monitorização frequente da idade das lamas e da razão alimento/microrganismo.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Un pasajero de un vuelo comercial desde un país del Magreb a otro del norte de Europa fallece durante el vuelo. El avión aterriza en el aeropuerto más próximo en ese momento, que es el de nuestra ciudad. Comunicado el hecho a la autoridad judicial local, esta ordena la práctica de la autopsia médico-legal. En el presente caso no se pudo conseguir ninguna información de los antecedentes patológicos del fallecido antes de la autopsia. Esta reveló la existencia de una colangitis supurada, debida a litiasis residual del colédoco, como causa de la muerte.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

La actividad industrial y el desarrollo material y económico, han traído como consecuencia la contaminación del aire, agua y el suelo; lo que ocasiona modificaciones físicas químicas y biológicas que han producido un deterioro en la calidad del agua, dando como resultado problemas de contaminación que afectan tanto la productividad de los sistemas como la salud humana. A las aguas de composición variada provenientes de uso municipal, industrial, comercial, agrícola, pecuario, o de cualquier otra índole, ya sea privada o pública que han sufrido una degradación o alteración en su calidad original se le conoce como agua residual. Este trabajo tiene como objetivo “Caracterizar las bacterias filamentosas en el funcionamiento de un reactor aerobio de la planta de tratamiento de aguas residuales de origen cervecero” para ello se estudió durante varios meses los parámetros físico-químicos y biológicos para poder así controlar de las bacterias filamentosas y así evitar en un futuro problemas de operación o poder controlar su crecimiento y por ende, ecológicos dentro del sistema de lodos activados. La identificación se realizó tomando muestras en el reactor aerobio y realizándole la tinción de Gram para posteriormente ser vistos en un microscopio de una resolución de 100x; luego se caracterizaron las bacterias juntas con los parámetros de operación del tanque de lodos por muestra y los resultados encontrados fueron la presencia de filamentos Microtrix Parvicella, Tipo 021N, y Sp1 (llamada así por no ser identificada, ni encontrada en la literatura), esta es una nueva especie encontrada, ya que es propia de este reactor aerobio y crecen principalmente en aguas cerveceras y por deficiencia de nutrientes en el sistema. Este trabajo nos permitió conocer la dinámica que existe entre los parámetros fisicoquímicos y los microorganismos que se encuentran en un biorreactor Aerobio. Esto nos llevó a comprender mejor el funcionamiento de estos sistemas dentro de plantas de aguas residuales de tipo industrial. ABSTRACT Industrial activity and the physical and economic development have resulted in contamination of air, water and soil, causing physical chemical and biological changes that have produced deterioration in water quality, resulting in pollution problems affects the productivity of the systems and human health. A varied composition waters from municipal, industrial, commercial, agricultural, livestock, or any other use, whether private or public who have suffered a degradation or alteration in their original quality is known as residual water. This work aims to "characterize filamentous bacteria in the operation of an aerobic reactor plant wastewater treatment brewer origin" for this physicochemical and biological parameters were studied for several months to thereby control bacteria stringy and avoid future problems in operation or to control their growth and thus ecological This work aims to "characterize filamentous bacteria in the operation of an aerobic reactor plant wastewater treatment brewer origin" for this physicochemical and biological parameters were studied for several months to thereby control bacteria stringy and avoid future problems in operation or to control their growth and thus ecological within the activated sludge system. This work allowed us to understand the dynamics between physicochemical parameters and microorganisms found in an aerobic bioreactor. This led us to better understand the operation of these systems within plants industrial wastewater.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objetivo: conocer las características epidemiológicas de pacientes que ingresan por sepsis severa (SS) y shock séptico (ShS); valorar la implementación de recomendaciones de la campaña Sobrevivir a las Sepsis (CSS) y determinar variables asociadas con mal pronóstico vital. Diseño: estudio prospectivo, observacional, cohorte única, multicéntrico, durante un año (setiembre 2011 - agosto 2012). Ámbito: cinco centros de Montevideo, del subsector público y privado con cobertura de 800.000 habitantes. Pacientes y métodos: 153 pacientes que ingresaron con diagnóstico de SS y ShS a las unidades de cuidados intensivos (UCI) de forma consecutiva. Variables de interés principales: aquellas relacionadas con características del paciente y episodio de sepsis, medidas diagnósticas y terapéuticas según la CSS en las primeras 48 horas, y pronósticas en UCI, hospital y a los seis meses. Resultados: se incluyeron 153 pacientes, la mediana de edad fue 68 años, la de Acute Physiology and Chronic Health Evaluation (APACHE II) fue de 24; 73,9% recibieron asistencia respiratoria mecánica (ARM), con una mediana de 8 días. La mediana de estadía en CTI fue de 12 y la de estadía hospitalaria fue de 19 días. De los episodios de SS, ShS, 69,3% de los casos fue comunitario; 77,8% presentó shock, y 37,9% inmunodebilidad-inmunocompromiso. Predominó la sepsis de origen respiratorio en 30,1%, se aisló microorganismos en 64,1%, siendo bacterianas 95,9%. La mortalidad en CTI fue 49,7%, hospitalaria 54,9% y a seis meses 58,8%. Se asociaron a mayor mortalidad hospitalaria: edad, APACHE II, inmunodebilidad-compromiso, demoras de ingreso a UCI e inicio de antimicrobianos y balance positivo. Conclusiones: los pacientes ingresan a UCI con formas severas o estado biológico comprometido. Existen demoras y limitaciones en el diagnóstico y terapéutica inicial, situaciones que se asocian a mayor mortalidad hospitalaria.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introducción El mal sistema de eliminación de aguas grises y negras está asociado con enfermedades infecto-contagiosas, tanto, en el ser humano, los animales y las plantas. Objetivo Determinar los sistemas de manejo de las aguas residuales domésticas en las viviendas e instituciones de la parroquia rural San Pablo de Shaglli del cantón Santa Isabel, durante el 2014. Material y métodos Se realizó un estudio descriptivo en la población de 115 personas. Los datos se obtuvieron por encuesta y se analizaron con el Software SPSS versión 15. La edad fluctuó entre 18-86 años, y la mediana, de 45. El 51.3 % fueron hombres. El 63.5 % tenían instrucción primaria, el 3.5 %, analfabetos, y el 6.1 %, instrucción superior. El 52.2 % eliminan las aguas grises provenientes de la cocina al aire libre; mientras que el 55.7 % de aguas provenientes del aseo personal, también, se eliminan al aire libre, al igual que el 6.26 % de las aguas grises provenientes del lavado de la ropa, y el 47.0 % eliminan las aguas negras en el pozo séptico. Conclusión Más del 50.0 % eliminan las aguas grises provenientes de la cocina, del aseo personal, del lavado de ropa al aire libre, y un porcentaje similar elimina las aguas negras en el pozo séptico.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

22 hojas : ilustraciones, fotografías.