941 resultados para Surface and interfaces
Resumo:
In this paper we report on the synthesis, characterization, and adsorption properties of the first 3-amino-1,2,4-triazole-modified porous silsesquioxane (ATPS). The isotherms of adsorption of MX2 (M = Cu(II), Co(II); X = Cl-, Br-, ClO4-) by ATPS were studied in ethanol and aqueous solutions at 298 K. The results showed that there is a good fit between the experimental data and the Langmuir isotherm. The adsorption capacity in both solvents followed the sequence Cu(II) >> Co(II). The lowest adsorption for Co(II) should be related to the largest hydration volume, which obstructs the adsorption capacity of the surface, and consequently causes a decrease in the number of cations adsorbed. For the salts with different anions the sequence was MCl2 > MBr2 > M(ClO4)2 in both solvents. The low affinity for M(ClO4)(2) toward the solid phase is a consequence of the poorer coordination ability of the ClO4-. Adsorptions from ethanol solutions were higher than those from aqueous solutions due to the higher polarity of water, which can more strongly solvate the solute and the basic sites on the surface. The following adsorption capacities (in mmol g(-1)) were determined: 0.24 (aq) and 0.84 (eth) for CuCl2, 0.09 (aq) and 0.16 (eth) for CuBr2, and 0.08 (aq) and 0.11 (eth) for Cu(ClO4)(2); 0.02 (aq) and 0.07 (eth) for CoCl2, 0.02 (aq) and 0.06 (eth) for CoBr2, and 0.01 (aq) and 0.05 (eth) for Co(ClO4)(2). (c) 2007 Elsevier B.V. All rights reserved.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Mechanisms of testicular thermoregulation, the relationship of scrotal, testicular vascular cone (TVC), and testicular morphology with thermoregulatory capability, and their effects on semen quality and sperm production were studied in 20 Bos indicus, 28 crossbred, and 26 Bos taurus bulls. The ratio of testicular artery length and volume to testicular volume were larger (P < 0.05) in B. indicus and crossbred bulls than in B. taurus bulls (1.03 and 0.94 cm/cm(2). versus 0.48 cm/cm(3); 0.034 and 0.047 ml/cm(3) versus 0.017 ml/cm(3), respectively). Testicular artery wall thickness (average 192.5, 229.0, and 290.0 mum, respectively) and arterial-venous blood distance in the TVC (average 330.5, 373.7, and 609.4 pm, respectively) were smallest in B. indicus, intermediary in crossbred, and greatest in B. taurus bulls (P < 0.05); the proximity between arterial and venous blood was consistent with the estimated decrease in arterial blood temperature after passage through the TVC (5.9, 5.0, and 2.9 degreesC, in B. indicus, crossbred, and B. taurus bulls, respectively). In crossbred and B. taurus bulls, there was a positive top-to-bottom scrotal temperature gradient and a negative testicular subtunic temperature gradient. However, in B. indicus bulls, both scrotal and testicular subtunic temperatures gradients were positive. Differences in the vascular arrangement, characteristics of the artery (e.g. wall thickness) or thickness of the tunica albuginea may have affected the testicular arterial blood and subtunic temperatures in B. indicus bulls. Better testicular thermoregulatory capability was associated with increased scrotal shape (pendulosity), testicular artery length and volume, and top-to-bottom gradient of the distance between the artery wall and the veins in the TVC. Increased semen quality was associated with increased testicular volume and scrotal subcutaneous (SQT) temperature gradient, and with decreased scrotal surface and testicular temperatures. Increased sperm production was associated with increased testicular artery volume, testicular volume, and SQT temperature gradient, and with decreased testicular artery wall thickness, scrotal circumference (SC), and scrotal surface, testicular subtunic, and epididymal temperatures. In conclusion, morphology of the TVC may contribute to the greater resistance of B. indicus bulls to high ambient temperatures by conferring a better testicular blood supply and by facilitating heat transfer between the testicular artery and veins. Testicular thermoregulation was associated with opposing scrotal and testicular subtunic temperatures gradients only in crossbred and B. taurus bulls. Scrotal, TVC, and testicular morphology influence testicular thermoregulatory capability and were associated with differences in semen quality and sperm production. (C) 2003 Elsevier B.V. All rights reserved.
Resumo:
Success of tooth replantation is limited because part of the replanted tooth is lost because of progressive root resorption. This study used histomorphometry and immunohistochemistry to evaluate the effect of low-level laser therapy (LLLT) on the healing process of rat teeth replanted after different extra-oral periods, simulating immediate and delayed replantation. Sixty Wistar rats (Rattus norvegicus albinus) had their maxillary right incisors extracted and randomly assigned to six groups (n = 10): C4, C30 and C45, in which the teeth were replanted 4 min (immediate), 30 min (delayed) and 45 min (delayed) after extraction, respectively, and L4, L30 and L45, in which the teeth were replanted after the same extra-alveolar times, but the root surfaces and the alveolar wounds were irradiated with a gallium-aluminum-arsenate (GaAlAs) diode laser before replantation. The animals were sacrificed after 60 days. The anatomic pieces containing the replanted teeth were obtained and processed for either histomorphometrical analysis under optical microscopy or immunohistochemical expression of receptor activator of nuclear factor Kappa-B (RANK), and its ligand (RANKL), osteoprotegerin (OPG) and tartrate-resistant acid phosphatase (TRAP) proteins. Areas of external replacement and inflammatory root resorption were observed in all groups, without statistically significant differences (P > 0.05). Ankylosis was more frequent in L30 than in C30 (P < 0.05). RANKL immunostaining predominated over RANK and OPG immunostaining in both groups with immediate tooth replantation (P < 0.05). For the 45-min extra-alveolar time, however, there was greater evidence of RANK immunostaining compared to RANKL for both control and laser-treated groups (P < 0.05). Positive TRAP immunostaining predominated in L4 and L30 (P < 0.05). In conclusion, under the tested conditions, the treatment of the root surface and the alveolar wound with LLLT did not improve the healing process after immediate and delayed tooth replantation in rats.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Purpose: The aim of this study was to compare 2 different methods of assessment of implants at different inclinations (90 degrees and 65 degrees)-with a profilometer and AutoCAD software. Materials and Methods: Impressions (n = 5) of a metal matrix containing 2 implants, 1 at 90 degrees to the surface and 1 at 65 degrees to the surface, were obtained with square impression copings joined together with dental floss splinting covered with autopolymerizing acrylic resin, an open custom tray, and vinyl polysiloxane impression material. Measurement of the angles (in degrees) of the implant analogs were assessed by the same blinded operator with a profilometer and through analysis of digitized images by AutoCAD software. For each implant analog, 3 readings were performed with each method. The results were subjected to a nonparametric Kruskal-Wallis test, with P <= .05 considered significant. Results: For implants perpendicular to the horizontal surface of the specimen (90 degrees), there were no significant differences between the mean measurements obtained with the profilometer (90.04 degrees) and AutoCAD (89.95 degrees; P=.9142). In the analyses of the angled implants at 65 degrees in relation to the horizontal surface of the specimen, significant differences were observed (P=.0472) between the mean readings with the profilometer (65.73 degrees) and AutoCAD (66.25 degrees). Conclusions: The degrees of accuracy of implant angulation recording vary among the techniques available and may vary depending on the angle of the implant. Further investigation is needed to determine the best test conditions and the best measuring technique for determination of the angle of the implant in vitro.
Resumo:
Purpose : To evaluate the effect of time of fluoride application gel, acidulated or neutral, on in vitro enamel resistance to demineralization and fluoride uptake. Materials and Methods: One hundred and ninety-two human enamel blocks were used in this study and 144 were treated with fluoride gel, acidulated or neutral, for I or 4 minutes. Ninety-six blocks treated with fluoride and 24 control blocks were submitted to a high cariogenic challenge. After the pH-cycling, enamel demineralization was assessed by surface and cross-sectional microhardness. Fluoride in the enamel blocks was also determined after removing an enamel layer by etching acid. Results: Acidulated fluoride gel formed more fluoride in enamel than neutral gel (P < 0.05), and it was also more efficient in reducing the demineralization of the enamel blocks submitted to a cariogenic challenge than the neutral one (P < 0.05). It was found that the time of application was significant in terms of fluoride uptake, but it did not render the enamel more resistant to dernineralization.
Resumo:
Objectives: This in vitro study assessed the effect of a 4% TiF4 varnish on demineralisation and remineralisation of sound enamel and artificial carious enamel lesions, respectively.Methods: Bovine sound and carious enamel (n = 110) were randomly allocated to each type of varnish: Duraphat (R))-D (NaF, 2.26%F, pH 4.5, Colgate-Brazil, n = 30), Duofluorid (R)-F (NaF, 2.71%F, pH 8.0, FGM-Brazil, n = 30), TiF4-T (2.45%F, pH 1.0, FGM-Brazil, n = 30) and no-fluoride-P (FGM-Brazil, pH 5.0, n = 20). For the formation of artificial enamel caries, half of the blocks were immersed in 32 mL buffer acetate solution (16 h), whereas the other half was maintained sound. The varnishes were applied onto the enamel surfaces. Thus, the samples were subjected to pH cycles (37 degrees C) for 7 days. The response variables tested were surface and cross-sectional hardness. Data were tested using Kruskal-Wallis test (p < 0.05).Results: All F varnishes significantly reduced demineralisation and increased remineralisation in comparison to placebo. The TiF4 did not significantly reduce the surface enamel softening when compared with the other F varnishes, but it decreased the loss of subsurface hardness to the same extent. In enamel blocks with previous artificial carious lesions, the TiF4 significantly improved the rehardening compared to the other varnishes up to 30 mu m depth.Conclusions: The TiF4 varnish was able to decrease the demineralisation and increase the remineralisation of previously sound and carious enamel, respectively. It was equally effective compared to NaF varnishes on reducing the demineralisation at subsurface, but it was more effective on improving the remineralisation at surface and subsurface. (c) 2007 Elsevier Ltd. All rights reserved.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The purpose of this study was to evaluate the effect of lethal photosensitization and guided bone regeneration (GBR) on the treatment of ligature-induced peri-implantitis in different implant surfaces. The treatment outcome was evaluated by clinical and histometric methods. A total of 40 dental implants with four different surface coatings (10 commercially pure titanium surface (cpTi); 10 titanium plasma-sprayed (TPS); 10 acid-etched surface; 10 surface-oxide sandblasted) were inserted into five mongrel dogs. After 3 months, the animals with ligature-induced peri-implantitis were subjected to surgical treatment using a split-mouth design. The controls were treated by debridment and GBR, while the test side received an additional therapy with photosensitization, using a GaAlAs diode laser, with a wavelength of 830 nm and a power output of 50 mW for 80 s (4 J/cm(2)), and sensitized toluidine blue O (100 mu g/ml). The animals were sacrificed 5 months after therapy. The control sites presented an earlier exposition of the membranes on all coating surfaces, while the test group presented a higher bone height gain. Re-osseointegration ranged between 41.9% for the cpTi surface and 31.19% for the TPS surface in the test sites; however differences were not achieved between the surfaces. The lethal photosensitization associated with GBR allowed for better re-osseointegration at the area adjacent to the peri-implant defect regardless of the implant surface.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The aim of this study was to determine the influence of three light-curing units, storage times and colors of the dental composite resin on the fluorescence. The specimens (diameter 10.0 +/- 0.1 mm, thickness 1.0 +/- 0.1 mm) were made using a stainless steel mold. The mold was filled with the microhybrid composite resin and a polyethylene film covered each side of the mold. After this, a glass slide was placed on the top of the mold. To standardize the top surface of the specimens a circular weight (1 kg) with an orifice to pass the light tip of the LCU was placed on the top surface and photo-activated during 40 s. Five specimens were made for each group. The groups were divided into 9 groups following the LCUs (one QTH and two LEDs), storage times (immediately after curing, 24 hours, 7 and 30 days) and colors (shades: A(2)E, A(2)D, and TC) of the composite resin. After photo-activation, the specimens were storage in artificial saliva during the storage times proposed to each group at 37 C and 100% humidity. The analysis of variance (ANOVA) and Tukey's post-hoc tests showed no significant difference between storage times (immediately, 24 hours and 30 days) (P > 0.05). The means of fluorescence had difference significant to color and light-curing unit used to all period of storage (P < 0.05). The colors had difference significant between them (shades: A2D < A2E < TC) (P < 0.05). The Ultraled (LED) and Ultralux (QTH) when used the TC shade showed higher than Radii (LED), however to A2E shade and A2D shade any difference were found (P > 0.05).
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)