963 resultados para Sensitivity and Specificity
Resumo:
In the early postoperative period of Cushing`s disease patients, desmopressin may stimulate ACTH secretion in the remnant corticotrophic tumour, but not in nontumour suppressed cells. Objective The aim of this study is to evaluate the serum cortisol responses to desmopressin after pituitary surgery, establishing an optimal cut-off for absolute increment (Delta) of serum cortisol (F) suitable to predict recurrence risk. Design Retrospective case record study. Patients Fifty-seven Cushing`s disease patients submitted to pituitary surgery and desmopressin stimulation in the early postoperative with a long-term follow-up (20-161 months) were studied. Methods and measurements Serum cortisol levels after desmopressin test (10 mu g IV) 15-30 days after adenomectomy were used to determine Delta F (absolute increment of F: F peak - F baseline). Sensitivity and specificity of Delta F were calculated and a ROC curve was performed to establish an optimal cut-off for Delta F to predict recurrence risk. Results Fifteen patients had immediate postoperative failure (basal F > 165 nmol/l; 6 mu g/dl) and one patient was lost during the follow-up. Forty-one patients achieved initial remission and were followed-up. Five of 11 patients who recurred had Delta F > 193 nmol/l (7 mu g/dl), but none of 30 patients who remained in prolonged remission showed Delta F > 193 nmol/l after postoperative desmopressin stimulation. Conclusions Persistence of cortisol response (Delta F > 193 nmol/l) to desmopressin in the early postoperative period can help to identify Cushing`s disease patients with initial remission who present risk for later recurrence.
Resumo:
Background. Lymphocyte proliferation testing (LPT) has some advantages over patch testing to diagnose allergic contact dermatitis. It is harmless, objective and can be used in clinical situations where patch testing is not recommended. Unfortunately, significant success has only been achieved with nickel. There are few studies on chromium LPT and they were performed with different methods, leading to inconsistent results. Methods. To determine the best parameters for chromium LPT, we tested 20 patients with allergic contact dermatitis to the metal and 20 controls, using various protocols. Results. The best sensitivity and specificity ratios were achieved with 6-day cultures stimulated with a range from 7.5 x 10(-4) to 5 x 10(-3) mol/L of nonfiltered chromium chloride solutions. The sensitivity, specificity and accuracy values found within this range were 65%, 95% and 80%, respectively. Conclusion. Further investigation is necessary to achieve better sensitivity values.
Resumo:
This study vas aimed to validate the American Speech-Language-Hearing Association Functional Assessment Of Communication Skills (ASHA FACS) for a Brazilian population. The scale was translated and adapted into Portuguese. Thirty-two patients with mild Alzheimer disease (AD). 25 patients with moderate AD. and 51 elderly without dementia were examined with Mini Mental State Examination, Geriatric Depression Scale. and Alzheimer Disease Assessment Scale-Cognitive subscale (ADAS-cog). The ASHA FACS was answered by their relative/caregiver. The scale`s internal consistency. its inter-examiner and intra-examiner`s reproducibility. and scale`s criterion validity were researched by correlation with ADAS-cog,. The sensitivity and specificity Were also researched. Statistical analyses indicated that the ASHA FACS has excellent internal consistency (Cronbach alpha = 0.955), test-retest reliability (interclass correlation coefficient = 0.995; P < 0.001). and inter-examiners (interclass correlation coefficient = 0.998: P < 0.001). It showed excellent criterion validity when correlated with ADAS-cog,. The ASHA FACS scale showed good sensitivity (75.0%) and specificity (82.4%) values once it is an ecologic and broad evaluation. The ASHA FACS Portuguese version is a valid and reliable instrument to verify communication alterations in AD patients and fills an important gap of efficiency indicators for speech language therapy in our country.
Resumo:
Follistatin is an activin-binding protein produced by several tissues, including endometrium and endometriotic implants. We aimed to quantify follistatin in patients with ovarian endometriosis and investigate its value as a diagnostic marker. Women undergoing laparoscopic excision of ovarian endometrioma (n = 52) or other benign ovarian cysts (n = 52) were studied, plus women with non-ovarian endometriosis (n = 11) and healthy controls (n = 27). Serum was collected from all subjects, and peritoneal and cystic fluid from a subset with endometrioma. Follistatin was measured by enzyme-linked immunosorbent assay. The diagnostic accuracy of follistatin to detect endometrioma was evaluated by receiver operating characteristic (ROC) curve and compared with cancer antigen (CA)-125. Serum follistatin was increased in women with ovarian endometrioma (2080 +/- 94 pg/ml) compared with controls (545 +/- 49 pg/ml, P < 0.001), other benign ovarian cysts (795 +/- 60 pg/ml, P < 0.001) or non-ovarian endometriosis (1271 +/- 115 pg/ml, P < 0.001). Cystic fluid showed a higher concentration of follistatin (9850 +/- 4461 pg/ml) than peritoneal fluid (1885 +/- 261 pg/ml, P < 0.001) and serum (P < 0.001). Follistatin levels detected 48/52 cases of endometrioma (92% sensitivity) at 1433 pg/ml cut-off, corresponding to 92% specificity. CA-125 detected only 44% of endometriomas with 90% specificity. ROC curve comparison showed follistatin was more accurate than CA-125 to discriminate women with endometrioma either from controls or women with other benign ovarian cysts (P < 0.0001). Serum follistatin is increased in women with endometriosis and allows clear distinction between endometrioma and other benign ovarian cysts. Follistatin has the sensitivity and specificity to become a useful clinical marker of ovarian endometrioma.
Resumo:
One of the challenges in screening for dementia in developing countries is related to performance differences due to educational and cultural factors. This study evaluated the accuracy of single screening tests as well as combined protocols including the Mini-Mental State Examination (MMSE), Verbal Fluency animal category (VF), Clock Drawing test (CDT), and Pfeffer Functional Activities Questionnaire (PFAQ) to discriminate illiterate elderly with and without Alzheimer`s disease (AD) in a clinical sample. Cross-sectional study with 66 illiterate outpatients diagnosed with mild and moderate AD and 40 illiterate normal controls. Diagnosis of AD was based on NINCDS-ADRDA. All patients were submitted to a diagnostic protocol including a clinical interview based on the CAMDEX sections. ROC curves area analyses were carried out to compare sensitivity and specificity for the cognitive tests to differentiate the two groups (each test separately and in two by two combinations). Scores for all cognitive (MMSE, CDT, VF) and functional assessments (PFAQ) were significantly different between the two groups (p < 0.001). The best screening instruments for this sample of illiterate elderly were the MMSE and the PFAQ. The cut-off scores for the MMSE, VF, CDT, and PFAQ were 17.5, 7.5, 2.5, and 11.5, respectively. The most sensitive combination came from the MMSE and PFAQ (94.1%), and the best specificity was observed with the combination of the MMSE and CDT (89%). Illiterate patients can be successfully screened for AD using well-known screening instruments, especially in combined protocols.
Resumo:
Objectives/Hypothesis: Polysomnography (PSG) is the gold-standard method for diagnosing obstructive sleep apnea (OSA). However, the gap between demand and capacity in performing PSG is a major health-care problem. We sought to validate a short day-time induced sleep for the diagnosis of OSA. Study Design: Prospective diagnostic method validation. Methods: We studied 25 consecutive patients referred to the sleep laboratory and 15 healthy volunteers. All subjects were evaluated by means of full overnight PSG (Full-PSG) and short day-time induced-sleep PSG (Induced-PSG). Sleep was monitored during both procedures (Embla, 16 channels). Sleep was induced by slow intravenous drip infusion of midazolam. Results: The population studied (N = 40) was 60% male (mean age, 42 +/- 10 years; body mass index, 29 +/- 6.5 kg/m(2)). Sleep was successfully induced in all subjects, and no complications were observed (midazolam doses, 6.2 +/- 3.8 mg; time of induced sleep 41.5 +/- 18.9 minutes). The apnea-hypopnea index (AHI) and minimal oxygen saturation during Full-PSG versus Induced-PSG were similar: median AHI (with 25%-75% interquartile range) was 13 (3-35) events per hour versus 17 (4-36) events per hour, and median oxygen saturation was 84% (75-90) versus 85% (76-92); P = .89 and P = .53, respectively. The majority of the respiratory events during induced sleep were obstructive and similar to those observed during Full-PSG. AHI and lowest oxygen saturation during Induced-PSG correlated significantly with Full-PSG (r = 0.67 and r = 0.77, respectively). Sensitivity and specificity for the diagnosis of OSA (AHI > 15 events per hour) by Induced-PSG were 0.83 and 0.72, respectively. Conclusions: Induced-PSG by midazolam during the day is safe and correlates with Full-PSG; it therefore is a promising alternative method in the diagnosis of OSA.
Resumo:
Objective. The purpose of this study was to evaluate the diagnostic usefulness of ulnar nerve sonography in leprosy neuropathy with electrophysiologic correlation. Methods. Twenty-one consecutive patients with leprosy (12 men and 9 women; mean age +/- SD, 47.7 +/- 17.2 years) and 20 control participants (14 men and 6 women; mean age, 46.5 +/- 16.2 years) were evaluated with sonography. Leprosy diagnosis was established on the basis of clinical, bacteriologic, and histopathologic criteria. The reference standard for ulnar neuropathy in this study was clinical symptoms in patients with proven leprosy The sonographic cross-sectional areas (CSAs) of the ulnar nerve in 3 different regions were obtained. Statistical analyses included Student t tests and receiver operating characteristic curve analysis. Results. The CSAs of the ulnar nerve were significantly larger in the leprosy group than the control group for all regions (P < .01). Sonographic abnormalities in leprosy nerves included focal thickening (90.5%), hypoechoic areas (81%), loss of the fascicular pattern (33.3%), and focal hyperechoic areas (4.7%). Receiver operating characteristic curve analysis showed that a maximum CSA cutoff value of 9.8 mm(2) was the best discriminator (sensitivity, 0.91; specificity, 0.90). Three patients with normal electrophysiologic findings had abnormal sonographic findings. Two patients had normal sonographic findings, of which 1 had abnormal electrophysiologic findings, and the other refused electrophysiologic testing. Conclusions. Sonography and electrophysiology were complementary for identifying ulnar nerve neuropathy in patients with leprosy, with clinical symptoms as the reference standard. This reinforces the role of sonography in the investigation of leprosy ulnar neuropathy.
Resumo:
The fact that the diagnosis of infection with dengue virus is usually made by detecting IgM antibodies during the convalescent phase of the disease interferes with disease management and, consequently, with reducing mortality rates. This study evaluated the sensitivity and specificity of detection of NS1 in samples of patients suspected of acute dengue virus infection in Brazil. The results were used to institute treatment and the sensitivity and specificity of detection of NS1 were compared to the results of detection of IgM, virus isolation, and RT-PCR. Detection of NS1 yielded better results than RTPCR and virus isolation. When considering IgM detection and RT-PCR positive results as ""gold standards,"" the sensitivity and specificity of the NS1 assay were 95.9% and 81.1%, respectively. All patients enrolled in the study were treated promptly and had an uneventful course of the disease. The detection of NS1 provided better results than the diagnostic techniques used currently during the acute phase of disease (RT-PCR and virus isolation). Detection of NS1 is an important tool for the diagnosis of acute dengue infection, particularly in highly endemic areas, allowing for rapid treatment of patients and reduction of disease burden. J. Med. Virol. 82: 1400-1405, 2010. (C) 2010 Wiley-Liss, Inc.
Resumo:
We examined the correlation between results obtained from the in vivo Draize test for ocular irritation and in vitro results obtained from the sheep red blood cell (RBC) haemolytic assay, which assesses haemolysis and protein denaturation in erythrocytes, induced by cosmetic products. We sought to validate the haemolytic assay as a preliminary test for identifying highly-irritative products, and also to evaluate the in vitro test as alternative assay for replacement of the in vivo test. In vitro and in vivo analyses were carried out on 19 cosmetic products, in order to correlate the lesions in the ocular structures with three in vitro parameters: (i) the extent of haemolysis (H50); (ii) the protein denaturation index (131); and (iii) the H50/DI ratio, which reflects the irritation potential (IP). There was significant correlation between maximum average scores (MAS) and the parameters determined in vitro (r = 0.752-0.764). These results indicate that the RBC assay is a useful and rapid test for use as a screening method to assess the IP of cosmetic products, and for predicting the IP value with a high level of concordance (94.7%). The assay showed high sensitivity and specificity rates of 91.6% and 100%, respectively.
Resumo:
Objectives Posterior urethral valves (PUV) are the most common cause of renal impairment in boys during early childhood. Although antenatal suspicion of this pathology has become quite common in recent years, prenatal diagnosis remains challenging. The aim of this study was to evaluate the predictive value of different ultrasound criteria currently used to diagnose PUV. Methods We reviewed the antenatal and postnatal files of 54 male patients referred to our center from 2000 to 2006 after detection of fetal bilateral hydronephrosis. The following ultrasound criteria were evaluated in relation to the postnatal diagnosis of P U V: amniotic fluid volume, bladder wall thickness, bladder dilatation and the presence of the `keyhole sign`. Results Forty-two fetuses (77.8%) were suspected to have PUV on prenatal examination. Out of these, 29 (69.0%) had PUV confirmed postnatally. The sensitivity and specificity of the antenatal diagnosis of PUV were 94% and 43%, respectively. Increased bladder wall thickness and bladder dilatation were highly associated with the diagnosis of PUV (P < 0.001). However, a thick-walled bladder was observed in 39.1% and a dilated bladder in 47.8% of the infants with a postnatal diagnosis other than PUV. The presence of the keyhole sign was not found to predict a diagnosis of PUV (P = 0.27). Conclusion In this series the use of classical prenatal ultrasound signs to diagnose PUV showed high sensitivity but low specificity. The best diagnostic indicators were increased bladder wall thickness and dilatation of the bladder. The keyhole sign was not found to be a reliable predictor of PUV. Copyright (C) 2009 ISUOG. Published by John Wiley & Sons, Ltd.
Resumo:
Objectives. To evaluate the diagnostic value of intraoral palpation at the lateral pterygoid (LP) area as part of the physical examination to detect myofascial pain, according to modified research diagnostic criteria for temporomandibular disorders. Study design. Fouty-four women composed the myofascial pain group, and 33 symptom-free age-matched were the control group. One examiner calibrated and blinded to group distribution performed 2 intraoral bilateral palpations of the lateral pterygoid. Results. The LP area palpation showed sensitivity and specificity values of 79.55% and 77.27%, respectively, and positive and negative likelihood ratios of 3.50 and 0.26, respectively. Conclusions. Palpation at the LP area did not reach acceptable values of specificity, and care must be taken when judging positive response to this procedure.
Resumo:
Objective. The diagnostic value of tests for antimyeloperoxidase antibodies (anti-MPO) for systemic vasculitis is less established than that for cytoplasmic antineutrophil cytoplasmic antibody (cANCA)/antiproteinase 3 antibodies (anti-PR3). Controversy exists regarding the optimal utilization of indirect immunofluorescence (IIF) ANCA testing versus antigen-specific ANCA testing. To summarize the pertinent data, we conducted a metaanalysis examining the diagnostic value of ANCA testing systems that include assays for anti-MPO. Methods. We performed a structured Medline search and reference list review. Target articles in the search strategy were those reporting the diagnostic value of immunoassays for anti-MPO for the spectrum of systemic necrotizing vasculitides that includes Wegener's granulomatosis, microscopic polyangiitis, the Churg-Strauss syndrome, and isolated pauci-immune necrotizing or crescentic glomerulonephritis, regardless of other types of ANCA tests. Inclusion criteria required specification of a consecutive or random patient selection method and the use of acceptable criteria for the diagnosis of vasculitis exclusive of ANCA test results. Weighted pooled summary estimates of sensitivity and specificity were calculated for anti-MPO alone, anti-MPO + perinuclear ANCA (pANCA), and anti-MPO/pANCA + anti-PR3/cANCA. Results. Of 457 articles reviewed, only 7 met the selection criteria. Summary estimates of sensitivity and specificity (against disease controls only) of assays for anti-MPO for the diagnosis of systemic necrotizing vasculitides were 37.1% (confidence interval 26.6% to 47.6%) and 96.3% (CI 94.1% to 98.5%), respectively. When the pANCA pattern by IIF was combined with anti-MPO testing, the specificity improved to 99.4%, with a lower sensitivity, 31.5%. The combined ANCA testing system (anti-PR3/cANCA + anti-MPO/pANCA) increased the sensitivity to 85.5% with a specificity of 98.6%. Conclusion. These results suggest that while anti-MPO is relatively specific for the diagnosis of systemic vasculitis, the combination system of immunoassays for anti-MPO and IIF for pANCA is highly specific and both tests should be used together given the high diagnostic precision required for these conditions. Because patients with ANCA associated vasculitis have either anti-MPO with pANCA or anti-PR3 with cANCA, and rarely both, a combined ANCA testing system including anti-PR3/cANCA and anti-MPO/pANCA is recommended to optimize the diagnostic performance of ANCA testing. (J Rheumatol 2001;28:1584-90)
Resumo:
Multiple frequency bioelectrical impedance analysis (MFBIA) has previously been shown to provide accurate relative measures of lymphedema in the upper limb of patients (1). This paper reports the results of a three year prospective study to evaluate the efficacy of MFBIA to predict the early onset of lymphedema in patients following treatment for breast cancer. Bioelectrical impedance measurements and circumferential measurements of each upper limb were recorded in healthy control subjects (n=60) to determine the normal range of the ratio (dominant/non-dominant) of extracellular and total limb volumes respectively. Patients undergoing surgery for the treatment of breast cancer were recruited as the study group; MFBIA and circumferential measurements were recorded pre-surgery, one month post-surgery and then at two month intervals for 24 months. One hundred and two patients were recruited into the study. Twenty patients developed lymphedema in the 24 months follow up period of this study. In each of these 20 cases MFBIA predicted the onset of the condition up to 10 months before the condition could be clinically diagnosed. Estimates of the sensitivity and specificity were both approximately 100%. At the time of detection by MFBIA, only one of the patients returned a positive test result from the total limb volumes determined from the circumferential measures. These results confirmed the suitability of the MFBIA technique as a reliable diagnostic procedure for the early detection of lymphedema.
Resumo:
Renal drug elimination is determined by glomerular filtration, tubular secretion, and tubular reabsorption. Changes in the integrity of these processes influence renal drug clearance, and these changes may not be detected by conventional measures of renal function such as creatinine clearance. The aim of the current study was to examine the analytic issues needed to develop a cocktail of marker drugs (fluconazole, rac-pindolol, para-aminohippuric acid, sinistrin) to measure simultaneously the mechanisms contributing to renal clearance. High-performance liquid chromatographic methods of analysis for fluconazole, pindolol, para-aminohippuric acid, and creatinine and an enzymatic assay for sinistrin were developed or modified and then validated to allow determination of each of the compounds in both plasma and urine in the presence of all other marker drugs. A pilot clinical study in one volunteer was conducted to ensure that the assays were suitable for quantitating all the marker drugs to the sensitivity and specificity needed to allow accurate determination of individual renal clearances. The performance of all assays (plasma and urine) complied with published validation criteria. All standard curves displayed linearity over the concentration ranges required, with coefficients of correlation greater than 0.99. The precision of the interday and intraday variabilities of quality controls for each marker in plasma and urine were all less than 11.9% for each marker. Recoveries of markers (and internal standards) in plasma and urine were all at least 90%. All markers investigated were shown to be stable when plasma or urine was frozen and thawed. For all the assays developed, there were no interferences from other markers or endogenous substances. In a pilot clinical study, concentrations of all markers could be accurately and reproducibly determined for a sufficient duration of time after administration to calculate accurate renal clearance for each marker. This article presents details of the analytic techniques developed for measuring concentrations of marker drugs for different renal elimination processes administered as a single dose to define the processes contributing to renal drug elimination.
Resumo:
Hereditary nonpolyposis colorectal cancer syndrome (HNPCC) is an autosomal dominant condition accounting for 2–5% of all colorectal carcinomas as well as a small subset of endometrial, upper urinary tract and other gastrointestinal cancers. An assay to detect the underlying defect in HNPCC, inactivation of a DNA mismatch repair enzyme, would be useful in identifying HNPCC probands. Monoclonal antibodies against hMLH1 and hMSH2, two DNA mismatch repair proteins which account for most HNPCC cancers, are commercially available. This study sought to investigate the potential utility of these antibodies in determining the expression status of these proteins in paraffin-embedded formalin-fixed tissue and to identify key technical protocol components associated with successful staining. A set of 20 colorectal carcinoma cases of known hMLH1 and hMSH2 mutation and expression status underwent immunoperoxidase staining at multiple institutions, each of which used their own technical protocol. Staining for hMSH2 was successful in most laboratories while staining for hMLH1 proved problematic in multiple labs. However, a significant minority of laboratories demonstrated excellent results including high discriminatory power with both monoclonal antibodies. These laboratories appropriately identified hMLH1 or hMSH2 inactivation with high sensitivity and specificity. The key protocol point associated with successful staining was an antigen retrieval step involving heat treatment and either EDTA or citrate buffer. This study demonstrates the potential utility of immunohistochemistry in detecting HNPCC probands and identifies key technical components for successful staining.