895 resultados para Sensitive sensors
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
This paper presents a non-model based technique to detect, locate, and characterize structural damage by combining the impedance-based structural health monitoring technique with an artificial neural network. The impedance-based structural health monitoring technique, which utilizes the electromechanical coupling property of piezoelectric materials, has shown engineering feasibility in a variety of practical field applications. Relying on high frequency structural excitations (typically>30 kHz), this technique is very sensitive to minor structural changes in the near field of the piezoelectric sensors. In order to quantitatively assess the state of structures, two sets of artificial neural networks, which utilize measured electrical impedance signals for input patterns, were developed. By employing high frequency ranges and by incorporating neural network features, this technique is able to detect the damage in its early stage and to estimate the nature of damage without prior knowledge of the model of structures. The paper concludes with an experimental example, an investigation on a massive quarter scale model of a steel bridge section, in order to verify the performance of this proposed methodology.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The development of more selective and sensitive analytical methods is of great importance in different areas of knowledge, covering, for example, food, biotechnological, environmental and pharmaceutical sectors. The study aimed to employ the technique electroanalytical differential pulse voltammetry (DPV) as an innovative and promising alternative for identification and quantification of organic compounds. The organic compounds were investigated in this study oxalic acid (OA) and folic acid (FA). The electrochemical oxidation of oxalic acid has been extensively studied as a model reaction in the boundary between the organic and inorganic electrochemistry. Since the AF, an essential vitamin for cell multiplication in all tissues, which is essential for DNA synthesis. The AF has been investigated using analytical techniques, liquid chromatography and molecular absorption spectrophotometry. The results obtained during the experimental procedure indicated that the process of electrochemical oxidation of oxalic acid is strongly dependent on the nature of the anode material and the oxidation mechanism, which affects their detection. Efficient removal was observed in Ti/PbO2 anodes, graphite, BDD and Pt 90, 85, 80 and 78% respectively. It was also shown that the DPV employing glassy carbon electrode offers a fast, simple, reliable and economical way to determine the AO during the process of electrochemical oxidation. Furthermore, electroanalytical methods are more expensive than commonly used chromatographic analysis and other instrumental methods involving toxic reagents and higher cost. Compared with the classical method of titration and DPV could be a good fit, confidence intervals and detection limits confirming the applicability of electroanalytical technique for monitoring the degradation of oxalic acid. For the study of AF was investigated the electrocatalytic activity of the carbon paste electrode for identification and quantification in pharmaceutical formulations by applying the DPV. The results obtained during the experimental procedure showed an irreversible oxidation peak at 9.1 V characteristic of FA. The carbon paste sensor showed low detection limit of 5.683×10−8 mol L-1 reducing matrix effects. The spectrophotometric analysis showed lower concentrations of HF compared with those obtained by HPLC and DPV. The levels of AF were obtained according to the methodology proposed by the Brazilian Pharmacopoeia. The electroanalytical method (DPV) proposed is cheaper than GC analysis commonly used by the pharmaceutical industry. The results demonstrated the potential of these electroanalytical techniques for future applications in environmental, chemical and biological sensors
Resumo:
Background: Current classifications of Mental Disorders are centered on Westernized concepts and constructs. Cross-cultural sensitivity emphasizes culturally-appropriate translations of symptoms and questions, assuming that concepts and constructs are applicable.Methods: Groups and individual psychiatrists from various cultures from Asia, Latin America, North Africa and Eastern Europe prepared descriptions of main symptoms and complaints of treatment-seeking women in their cultures, which are interpreted by clinicians as a manifestation of a clinically-relevant dysphoric disorder. They also transliterated the expressions of DSM IV criteria of main dysphoric disorders in their cultures.Results: In many non-western cultures the symptoms and constructs that are interpreted and treated as dysphoric disorders are mostly somatic and are different from the Western-centered DSM or ICD systems. In many cases the DSM and ICD criteria of depression and anxieties are not even acknowledged by patients.Limitations: the descriptive approach reported here is a preliminary step which involved local but Westernized clinicians-investigators following a biomedical thinking. It should be followed by a more systematic-comprehensive surveys in each culture.Conclusions: Westernized concepts and constructs of mental order and disorders are not necessarily universally applicable. Culturallysensitive phenomena, treatments and treatment responses may be diversified. Attempts at their cross-cultural harmonization should take into consideration complex interactional multi-dimensional processes. (c) 2006 Elsevier B.V. All rights reserved.
Resumo:
CDX2 is a recently cloned homeobox gene that encodes an intestine-specific transcription factor, expressed in the nuclei of epithelial cells throughout the intestine, from duodenum to rectum. While expression of CDX2 protein in primary and metastatic colorectal carcinomas has been previously documented, neither the sensitivity nor the specificity of CDX2 expression, as determined by immunohistochemistry, for colorectal adenocarcinoma has been determined. We performed an immunohistochemical survey of 476 tumors with a monoclonal antibody, CDX2-88, including 89 tumors from the colon and duodenum and 95 tumors from other gastrointestinal sites, including the esophagus, stomach, pancreatobiliary system, gastrointestinal carcinoids, and liver. CDX2 was expressed uniformly (that is, in 76-100% of tumor cells) in all but one of the evaluated colorectal and duodenal tumors. High-level expression of CDX2 was also found, however, in mucinous ovarian carcinomas and adenocarcinomas primary to the urinary bladder of which 64% and 100% were positive, respectively. Gastric, gastroesophageal, and pancreatic adenocarcinomas and cholangiocarcinomas all showed similar, heterogeneous patterns of CDX2 expression. Most tumors in each group showed CDX2 expression by a minority of cells, whereas a substantial minority of cases in each group was completely negative and a smaller minority was uniformly positive. Gastrointestinal carcinoids gave similarly varied results, but the majority (58%) was negative. Hepatocellular carcinomas showed no expression of CDX2. Only very rare examples of carcinomas of the genitourinary and gynecologic tracts, breast, lung, and head and neck showed significant levels of CDX2 expression. In this study of primary and metastatic epithelial tumors, uniform CDX2 expression is demonstrated to be an exquisitely sensitive and highly, but incompletely, specific marker of intestinal adenocarcinomas. Compared with villin, a previously described marker of GI adenocarcinomas, CDX2 demonstrated superior sensitivity and comparable specificity. CDX2 expression can be seen, however, in selected non-GI adenocarcinomas such as mucinous ovarian carcinomas and adenocarcinomas of the urinary bladder.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Anisotropic Magnetoresistive (AMR) sensors shows a new possibility to detect magnetic fields produced by magnetic particles present in the gastrointestinal (GI) tract. A system that uses excitation and detection of magnetic field was developed using AMR sensor. A magnetic flux concentrator was also studied to increase the sensitivity of AMR in this work.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Head and neck cancer remains a morbid and often fatal disease and at the present time few effective molecular markers have been identified. The purpose of the present work was to identify new molecular markers for head and neck squamous cell carcinoma (HNSCC). We applied methylation-sensitive arbitrarily primed PCR (MS/APPCR) to isolate sequences differentially methylated in HNSCC. The most frequently hypermethylated fragment we found maps close to a cytosine guanine dinucleotide (CpG) island on chromosome 9q33.2, and hypermethylation of this CpG island was associated with transcriptional silencing of an alternative transcript of the LHX6 gene. Using combined bisulfite restriction analysis (COBRA), hypermethylation of this fragment was detected in 13 of 14 (92.8%) HNSCC cell lines studied and 21 of 32 (65.6%) primary tumors, whereas little or no methylation was seen in 10 normal oral mucosa samples. We extended this investigation to other cancer cell lines and methylation was found in those derived from colon, breast, leukemia and lung, and methylation was also found in 12/14 primary colon tumors. These findings suggest that differentially methylated (DIME)-6 hypermethylation is a good cancer marker in HNSCC as well as in other kinds of neoplasias and confirm the importance of searching for markers of epigenetic dysregulation in cancer.
Resumo:
A careful analysis of the impedance response of SnO2 thick films under vacuum and air atmosphere is reported in the present work. The AC electrical resistance was analyzed and it was shown that it is highly frequency dependent. Different models and its equivalent circuit representation were proposed and carefully analyzed based on the microstructure features of the device. Basically, an interpretation of the frequency dependent resistance was proposed based on the fact that different grains characteristics and junctions exist. These different grains and junctions are the main source of resistance dependent feature. An equivalent circuit model, considering different grain sizes associated with different grain boundary junctions characteristics, was introduced so that a consistent interpretation of the results was possible.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)