968 resultados para Palos Heights


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The scavenging processes of chemical species have been previously studied with numerical modeling, in order to understand the gas and particulate matter intra-reservoir transferences. In this study, the atmospheric (RAMS) and scavenging (B.V.2) models were used, in order to simulate sulfate concentrations in rainwater using scavenging processes as well as the local atmospheric conditions obtained within the LBA Project in the State of Rondonia, during a dry-to-wet transition season. Two case studies were conducted. The RAMS atmospheric simulation of these events presented satisfactory results, showing the detailed microphysical processes of clouds in the Amazonian region. On the other hand, with cloud entrainments, observed values have been overestimated. Modeled sulfate rainwater concentration, using exponential decay and cloud heights of 16 km and no entrainments, presented the best results, reaching 97% of the observed value. The results, using shape parameter 5, are the best, improving the overall result. (C) 2008 Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

An one-dimensional atmospheric second order closure model, coupled to an oceanic mixed layer model, is used to investigate the short term variation of the atmospheric and oceanic boundary layers in the coastal upwelling area of Cabo Frio, Brazil (23 degrees S, 42 degrees 08`W). The numerical simulations were carried out to evaluate the impact caused by the thermal contrast between atmosphere and ocean on the vertical extent and other properties of both atmospheric and oceanic boundary layers. The numerical simulations were designed taking as reference the observations carried out during the passage of a cold front that disrupted the upwelling regime in Cabo Frio in July of 1992. The simulations indicated that in 10 hours the mechanical mixing, sustained by a constant background flow of 10 in s(-1), increases the atmospheric boundary layer in 214 in when the atmosphere is initially 2 K warmer than the ocean (positive thermal contrast observed during upwelling regime). For an atmosphere initially -2 K colder than the ocean (negative thermal contrast observed during passage of the cold front), the incipient thermal convection intensifies the mechanical mixing increasing the vertical extent of the atmospheric boundary layer in 360 in. The vertical evolution of the atmospheric boundary layer is consistent with the observations carried out in Cabo Frio during upwelling condition. When the upwelling is disrupted, the discrepancy between the simulated and observed atmospheric boundary layer heights in Cabo Frio during July of 1992 increases considerably. During the period of 10 hours, the simulated oceanic mixed layer deepens 2 in and 5.4 in for positive and negative thermal contrasts of 2 K and -2 K, respectively. In the latter case, the larger vertical extent of the oceanic mixed layer is due to the presence of thermal convection in the atmospheric boundary layer, which in turn is associated to the absence of upwelling caused by the passage of cold fronts in Cabo Frio.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study investigated the physical processes involved in the development of thunderstorms over southwestern Amazon by hypothesizing causalities for the observed cloud-to-ground lightning variability and the local environmental characteristics. Southwestern Amazon experiences every year a large variety of environmental factors, such as the gradual increase in atmospheric moisture, extremely high pollution due to biomass burning, and intense deforestation, which directly affects cloud development by differential surface energy partition. In the end of the dry period it was observed higher percentages of positive cloud-to-ground (+CG) lightning due to a relative increase in +CG dominated thunderstorms (positive thunderstorms). Positive (negative) thunderstorms initiated preferentially over deforested (forest) areas with higher (lower) cloud base heights, shallower (deeper) warm cloud depths, and higher (lower) convective potential available energy. These features characterized the positive (negative) thunderstorms as deeper (relatively shallower) clouds, stronger (relatively weaker) updrafts with enhanced (decreased) mixed and cold vertically integrated liquid. No significant difference between thunderstorms (negative and positive) and nonthunderstorms were observed in terms of atmospheric pollution, once the atmosphere was overwhelmed by pollution leading to an updraft-limited regime. However, in the wet season both negative and positive thunderstorms occurred during periods of relatively higher aerosol concentration and differentiated size distributions, suggesting an aerosol-limited regime where cloud electrification could be dependent on the aerosol concentration to suppress the warm and enhance the ice phase. The suggested causalities are consistent with the invoked hypotheses, but they are not observed facts; they are just hypotheses based on plausible physical mechanisms.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We used mixtures of genomic DNA from two genetically distinct isolates from Brazil, 42M and 312M, to investigate how accurately 12-locus microsatellite typing describes the overall genetic diversity and characterizes multilocus haplotypes in multiple-clone Plasmodium vivax infections. We found varying PCR amplification efficiencies of microsatellite alleles; for example, from the same 1:1 mixture of 42M and 312M DNA we amplified predominantly 312M-type alleles at 10 loci and 42M-type alleles at 2 loci. All microsatellite alleles were accurately scored in 1:0.5 and 1:0.25 312M:42M DNA mixtures, even when minor peak heights did not meet previously suggested criteria for minor allele detection in multiple-clone infections. Relative proportions of major and minor alleles were unaffected by multiple displacement amplification of template DNA prior to PCR-based microsatellite typing. Although microsatellite typing may detect minor alleles in clone mixtures, amplification biases may lead to inaccurate assignment of predominant haplotypes in multiple-clone P. vivax infections. (C) 2008 Elsevier Inc. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This work presents a numerical method suitable for the study of the development of internal boundary layers (IBL) and their characteristics for flows over various types of coastal cliffs. The IBL is an important meteorological occurrence for flows with surface roughness and topographical step changes. A two-dimensional flow program was used for this study. The governing equations were written using the vorticity-velocity formulation. The spatial derivatives were discretized by high-order compact finite differences schemes. The time integration was performed with a low storage fourth-order Runge-Kutta scheme. The coastal cliff (step) was specified through an immersed boundary method. The validation of the code was done by comparison of the results with experimental and observational data. The numerical simulations were carried out for different coastal cliff heights and inclinations. The results show that the predominant factors for the height of the IBL and its characteristics are the upstream velocity, and the height and form (inclination) of the coastal cliff. Copyright (C) 2010 John Wiley & Sons, Ltd.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We determined by means of photoluminescence measurements the dependence on temperature of the transition energy of excitons in GaAs/Al(x)Ga(1-x)As quantum wells with different alloy concentrations (with different barrier heights). Using a fitting procedure, we determined the parameters which describe the behavior of the excitonic transition energy as a function of temperature according to three different theoretical models. We verified that the temperature dependence of the excitonic transition energy does not only depend on the GaAs material but also depends on the barrier material, i.e. on the alloy composition. The effect of confinement on the temperature dependence of the excitonic transition is discussed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The traditional reduction methods to represent the fusion cross sections of different systems are flawed when attempting to completely eliminate the geometrical aspects, such as the heights and radii of the barriers, and the static effects associated with the excess neutrons or protons in weakly bound nuclei. We remedy this by introducing a new dimensionless universal function, which allows the separation and disentanglement of the static and dynamic aspects of the breakup coupling effects connected with the excess nucleons. Applying this new reduction procedure to fusion data of several weakly bound systems, we find a systematic suppression of complete fusion above the Coulomb barrier and enhancement below it. Different behaviors are found for the total fusion cross sections. They are appreciably suppressed in collisions of neutron-halo nuclei, while they are practically not affected by the breakup coupling in cases of stable weakly bound nuclei. (C) 2009 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this work, we have studied the surface morphology of photo-irradiated poly(p-phenylene vinylene) (PPV) thin films by using atomic force microscopy (AFM). We have analyzed the first-order statistical parameters, the height distribution and the distance between selected peaks. The second-order statistical analysis was introduced calculating the auto-covariance function to determine the correlation length between heights. We have observed that the photo-irradiation process produces a surface topology more homogeneous and isotropic such as a normal surface. In addition, the polymer surface irradiation can be used as a new methodology to obtain materials optically modified. (C) 2009 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In Sweden solar irradiation and space heating loads are unevenly distributed over the year. Domestic hot water loads may be nearly constant. Test results on solar collector performance are often reported as yearly output of a certain collector at fixed temperatures, e g 25, 50 and 75 C. These data are not suitable for dimensioning of solar systems, because the actual performance of the collector depends heavily on solar fraction and load distribution over the year.At higher latitudes it is difficult to attain high solar fractions for buildings, due to overheating in summer and small marginal output for added collector area. Solar collectors with internal reflectors offer possibilities to evade overheating problems and deliver more energy at seasons when the load is higher. There are methods for estimating the yearly angular irradiation distribution, but there is a lack of methods for describing the load and the storage in such a way as to enable optical design of season and load adapted collectors.This report describes two methods for estimation of solar system performance with relevance for season and load adaption. Results regarding attainable solar fractions as a function of collector features, load profiles, load levels and storage characteristics are reported. The first method uses monthly collector output data at fixed temperatures from the simulation program MINSUN for estimating solar fractions for different load profiles and load levels. The load level is defined as estimated yearly collector output at constant collector temperature divided be yearly load. This table may examplify the results:CollectorLoadLoadSolar Improvementtypeprofile levelfractionover flat plateFlat plateDHW 75 %59 %Load adaptedDHW 75 %66 %12 %Flat plateSpace heating 50 %22 %Load adaptedSpace heating 50 %28 %29 %The second method utilises simulations with one-hour timesteps for collectors connected to a simplified storage and a variable load. Collector output, optical and thermal losses, heat overproduction, load level and storage temperature are presented as functions of solar incidence angles. These data are suitable for optical design of load adapted solar collectors. Results for a Stockholm location indicate that a solar combisystem with a solar fraction around 30 % should have collectors that reduce heat production at solar heights above 30 degrees and have optimum efficiency for solar heights between 8 and 30 degrees.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This report describes the work done creating a computer model of a kombi tank from Consolar. The model was created with Presim/Trnsys and Fittrn and DF were used to identify the parameters. Measurements were carried out and were used to identify the values of the parameters in the model. The identifications were first done for every circuit separately. After that, all parameters are normally identified together using all the measurements. Finally the model should be compared with other measurements, preferable realistic ones. The two last steps have not yet been carried out, because of problems finding a good model for the domestic hot water circuit.The model of the domestic hot water circuit give relatively good results for low flows at 5 l/min, but is not good for higher flows. In the report suggestions for improving the model are given. However, there was not enough time to test this within the project as much time was spent trying to solve problems with the model crashing. Suggestions for improving the model for the domestic circuit are given in chapter 4.4. The improved equations that are to be used in the improved model are given by equation 4.18, 4.19 and 4.22.Also for the boiler circuit and the solar circuit there are improvements that can be done. The model presented here has a few shortcomings, but with some extra work, an improved model can be created. In the attachment (Bilaga 1) is a description of the used model and all the identified parameters.A qualitative assessment of the store was also performed based on the measurements and the modelling carried out. The following summary of this can be given: Hot Water PreparationThe principle for controlling the flow on the primary side seems to work well in order to achieve good stratification. Temperatures in the bottom of the store after a short use of hot water, at a coldwater temperature of 12°C, was around 28-30°C. This was almost independent of the temperature in the store and the DHW-flow.The measured UA-values of the heat exchangers are not very reliable, but indicates that the heat transfer rates are much better than for the Conus 500, and in the same range as for other stores tested at SERC.The function of the mixing valve is not perfect (see diagram 4.3, where Tout1 is the outlet hot water temperature, and Tdhwo and Tdhw1 is the inlet temperature to the hot and cold side of the valve respectively). The outlet temperature varies a lot with different temperatures in the storage and is going down from 61°C to 47°C before the cold port is fully closed. This gives a problem to find a suitable temperature setting and gives also a risk that the auxiliary heating is increased instead of the set temperature of the valve, when the hot water temperature is to low.Collector circuitThe UA-value of the collector heat exchanger is much higher than the value for Conus 500, and in the same range as the heat exchangers in other stores tested at SERC.Boiler circuitThe valve in the boiler circuit is used to supply water from the boiler at two different heights, depending on the temperature of the water. At temperatures from the boiler above 58.2°C, all the water is injected to the upper inlet. At temperatures below 53.9°C all the water is injected to the lower inlet. At 56°C the water flow is equally divided between the two inlets. Detailed studies of the behaviour at the upper inlet shows that better accuracy of the model would have been achieved using three double ports in the model instead of two. The shape of the upper inlet makes turbulence, that could be modelled using two different inlets. Heat lossesThe heat losses per m3 are much smaller for the Solus 1050, than for the Conus 500 Storage. However, they are higher than those for some good stores tested at SERC. The pipes that are penetrating the insulation give air leakage and cold bridges, which could be a major part of the losses from the storage. The identified losses from the bottom of the storage are exceptionally high, but have less importance for the heat losses, due to the lower temperatures in the bottom. High losses from the bottom can be caused by air leakage through the insulation at the pipe connections of the storage.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Este trabalho buscou estudar um sistema de integração lavoura-pecuária com diferentes alturas de pastos, no período de inverno, e seus reflexos sobre a dinâmica da pastagem e o desempenho animal. O experimento foi conduzido em uma pastagem de aveia + azevém manejada sob diferentes intensidades de pastejo. O delineamento experimental foi de blocos ao acaso com quatro tratamentos (10, 20, 30 e 40 cm de altura de manejo) e três repetições. Utilizaramse terneiros de corte de cruzamento industrial com idade e peso médio inicial de 10 meses e 210 kg, respectivamente. O método de pastejo foi contínuo com lotação variável. A adubação de base foi de 400 kg/ha de superfosfato simples e de 90 kg/ha de N em cobertura. As alturas do pasto afetaram a massa de forragem (MF), onde para cada cm de aumento na altura acima de 10 cm, houve incremento na matéria seca da pastagem em cerca de 86 kg/ha de MS. O aumento no ganho médio diário (GMD) foi condicionado pelo incremento na qualidade e/ou na quantidade de forragem disponível, e o modelo de resposta do GMD em relação às alturas do pasto, resultou em valores de 0,73 e 1,14 kg/animal/dia nos tratamentos de maior e menor GMD, respectivamente, que foram de 10 cm e 30 cm de altura. No rendimento de carcaça não houve diferença (P>0,05) entre os tratamentos, uma vez que todos os valores ficaram em torno de 51%. Quanto ao peso de carcaça quente e fria, peso de costilhar, escore de condição corporal e grau de acabamento, observou-se comportamento muito similar à evolução do ganho médio diário dos animais.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O sistema de franquias vem recebendo um destaque cada vez maior nas mídias voltadas para negócios devido ao seu grande desenvolvimento tanto no Brasil quanto no restante do mundo, apresentando um alto índice de crescimento, além de possuir um grande potencial para atingir patamares ainda maiores. Com base nas teorias da agência e de recursos da empresa, foram descritas as principais abordagens sobre este setor, ampliando o conceito de contrato como suporte da relação entre franqueadores e franqueados para uma análise qualitativa sobre o relacionamento entre as partes, identificando ainda suas evoluções ao longo do tempo, vantagens e desvantagens, modelos e desafios de gestão. Um estudo de âmbito nacional realizado por Toledo e Proença (2005) enalteceu que um dos grandes motivos que geram o insucesso de uma rede de franquias é a falta de comprometimento na manutenção do bom relacionamento do franqueador para com seus franqueados. E este é o tema central deste trabalho, com o objetivo de dar a devida importância a este tópico, mostrando como ele é influenciado pelo grau de maturidade da rede e a sua relevância para o sucesso do negócio. Através de um estudo comparativo de casos, de caráter exploratório, tendo como principal forma de coleta de dados as entrevistas presenciais realizadas com franqueadores e franqueados de duas redes no segmento de alimentação brasileiro, foram obtidos resultados quanto a forma com que o relacionamento tem sido gerido por ambas as partes, em diversos âmbitos, e a sua relação com o estágio de maturidade em que a rede se encontra, tornando o estudo relevante para o mercado, com contribuições tanto acadêmicas, como a congruência de pesquisas, quanto corporativas, como a conexão de boas práticas e lições aprendidas com os conceitos abordados.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This research presents a study investigating the correlation between the environmental-physycal charcateristics of cities and the formation of its micro-climates. The study was conducted in the central area of Fortaleza characterized as a stable and consolidated area, where the city originated and currently faces serious problems in its urban dynamics. The points of measurements were determined by the elaboration and analysis of topography maps, height of buildings, land use, type of surface coating and vegetation, following the methodology of Katzschner (1997). A zoning map was then determined, according to common morphological characteristics of the 12 measurement points, which were based on a set of Romero s (2001) bioclimatic criteria. Air measurements, temperature, humidity, intensity and direction of winds were made in transect form in two different circuits in the study area, with six points of data collection in each area, in three different times: 6:00 am, 1:00pm and 7:00pm, during two periods of the year: August 2008 and March 2009. The results verified the influence of different environmental-physical types in the behavior of the climatic variables that were collected. A verticalização tão condenada em algumas situações se bem equilibrada e controlada pode reduzir as temperaturas do ar através do sombreamento dos espaços urbanos e possibilidade de maior permeabilidade a ventilação natural. The highest average air temperature and lower humidity were recorded at the point I at all times. This situation may have been in result of the high density, poor vegetation and extended paving of the ground. According to the results, it s clear the positive influence vegetation has on easing air temperature. Another indicator observed that areas with a greater variation in building heights tend to present decreased average air temperature. High rise structure, planned in accordance to urban air quality parameters, can reduce air temperatures by the shading of urban spaces and the possibility of greater penetration of natural ventilation

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This research investigates the microclimate and the morphology features of the central campus of the UFRN, in Natal-RN, through the use of bioclimatic tools of analysis in order to assist the implementation of the campus´ Master Plan. It develops a diagnosis of the evolution and growth of the urban space surveyed by analyzing its initial plan and the basic urban conception behind it, as well as the morphology and typologies utilized. The study makes a qualitative analysis of the local microclimate by using Katzschner (1997) methodology, with land-use and topography maps, building heights, vegetation and soil covering. It also makes use of the methodology proposed by Oliveira (1993), which examines, from the bioclimatic standpoint, the human environment as related to the urban form (site and built mass). It identifies zones whose climatic characteristics are representative of the local microclimate and classifies them into areas to be strictly preserved, areas to be protected and areas to be improved. By means of the methodology for spatial and environmental assessment developed by Bustos Romero (2001), the survey selects characteristic points of each area in order to register the environmental data relative to the two basic seasons found in the region where the campus is located, that is, the dry and the rainy season, so that it can evaluate changes in the environment which might have been caused by urban density growth, by arborization or by the influence of the urban form. It then proceeds to a quantitative and statistical survey of the collected data with the purpose of evaluating the degree of influence of the identified features over the environmental variables along the different scales of approach. The study shows the existence of different microclimates and emphasizes the relevance of the bioclimatic analysis of the built environment as a tool for the decision-making process along the development of the Master Plan for UFRN Central Campus

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Nickel alloys are frequently used in applications that require resistance at high temperatures associated with resistance to corrosion. Alloys of Ni-Si-C can be obtained by means of powder metallurgy in which powder mixtures are made of metallic nickel powders with additions of various alloying carriers for such were used in this study SiC, Si3N4 or Si metal with graphite. Carbonyl Ni powder with mean particle size of 11 mM were mixed with 3 wt% of SiC powders with an average particle size of 15, 30 and 50 μm and further samples were obtained containing 4 to 5% by mass of SiC with average particle size of 15 μm. Samples were also obtained by varying the carrier alloy, these being Si3N4 powder with graphite, with average particle size of 1.5 and 5 μm, respectively. As a metallic Si graphite with average particle size of 12.5 and 5 μm, respectively. The reference material used was nickel carbonyl sintered without adding carriers. Microstructural characterization of the alloys was made by optical microscopy and scanning electron microscopy with semi-quantitative chemical analysis. We determined the densities of the samples and measurement of microhardness. We studied the dissociation of carriers alloy after sintering at 1200 ° C for 60 minutes. Was evaluated also in the same sintering conditions, the influence of the variation of average particle size of the SiC carrier to the proportion of 3% by mass. Finally, we studied the influence of variation of the temperatures of sintering at 950, 1080 and 1200 ° C without landing and also with heights of 30, 60, 120 and 240 minutes for sintering where the temperature was 950 °C. Dilatometry curves showed that the SiC sintered Ni favors more effectively than other carriers alloy analyzed. SiC with average particle size of 15 μm active sintering the alloy more effectively than other SiC used. However, with the chemical and morphological analyzes for all leagues, it was observed that there was dissociation of SiC and Si3N4, as well as diffusion of Si in Ni matrix and carbon cluster and dispersed in the matrix, which also occurred for the alloys with Si carriers and metallic graphite. So the league that was presented better results containing Si Ni with graphite metallic alloy as carriers, since this had dispersed graphite best in the league, reaching the microstructural model proposed, which is necessary for material characteristic of solid lubricant, so how we got the best results when the density and hardness of the alloy