955 resultados para Nurse–patient ratio
Resumo:
[EN]Octopus vulgaris is a potential candidate to diversify European aquaculture for its rapid growth and high market prices (Vaz Pires et al. 2004). One factor affecting industrial development of octopus culture is sexual maturation under rearing conditions. Octopus females can lose up to 30-60% of their initial body weight during egg-laying (Iglesias et al., 2000) and die after the paralarvae hatch (Guerra,1992), while a correlation between males death and spermatic sac depletion has being recently reported by Estefanell et al. (2010b). The present experiment discusses the effect of three different sex ratios on growth, sexual maturation and survival in O. Vulgaris. Conclusions: Discarded bogue from fish farms could be used as alternative diet for the final stage of O. vulgaris ongrowing ; Male segregation would maximize biomass increment ; Under the conditions described, sex ratios close to 1:1 produced higher biomass increment than 4:1
Resumo:
[EN] Nitrogen (N) is essential for life, but its availability is frequently limited in ocean ecosystems. Among all the compounds which influence the N pool, ammonium (NH4+) represents the major source of N for autotrophs. This NH4+ is provided by bacterial remineralization and heterotrophic grazers, with the mesozooplankton responsible for 12% to 33% of the total NH4+ recycled. Quantifying the excretion physiology of zooplankton is then, necessary to understand the basis of an aquatic ecosystem’s productivity.
The measurement of glutamate dehydrogenase (GDH) activity has been widely used to assess the NH4+ excretion rates in planktonic communities. However, its relationship with the physiology varies with temperature and the nutritional status of the organisms, among other variables. Here we compare the GDH/RNH4+ ratio between oceanic regions with different trophic conditions. Strengthening our knowledge of the relationship between GDH activities and the NH4+ excretion rates will lead to more meaningful interpretations of the mesoscale variations in planktonic NH4+ excretion.
Resumo:
[EN]Nitrogen (N) is essential for life, but its availability is frequently limited in ocean ecosystems. Among all the compounds which influence the N pool, ammonium (NH4+) represents the major source of N for autotrophs. This NH4+ is provided by bacterial remineralization and heterotrophic grazers, with the mesozooplankton responsible for 12% to 33% of the total NH4+ recycled. Quantifying the excretion physiology of zooplankton is then, necessary to understand the basis of an aquatic ecosystem?s productivity. The measurement of glutamate dehydrogenase (GDH) activity has been widely used to assess the NH4+ excretion rates in planktonic communities. However, its relationship with the physiology varies with temperature and the nutritional status of the organisms, among other variables. Here we compare the GDH/RNH4+ ratio between oceanic regions with different trophic conditions. Strengthening our knowledge of the relationship between GDH activities and the NH4+ excretion rates will lead to more meaningful interpretations of the mesoscale variations in planktonic NH4+ excretion.
Resumo:
[EN]This paper presents our research about nucleation and its dependency with external conditions, as well as the internal characteristics of the solution itself. Among the research lines of our group, we has been studying the influence of electric fields over two different but related compounds: Lithium-Potassium Sulfate and Lithium-Amonium Sulfate, which both of them show a variation on the nucleation ratio when an electric field is applied during the crystal growth. Moreover, in this paper will be explained a laboratory protocol to teach universitary Science students the nucleation process itself and how it depends on external applied conditions, e.g. electric fields.
Resumo:
The atmospheric muon charge ratio, defined as the number of positive over negative charged muons, is an interesting quantity for the study of high energy hadronic interactions in atmosphere and the nature of the primary cosmic rays. The measurement of the charge ratio in the TeV muon energy range allows to study the hadronic interactions in kinematic regions not yet explored at accelerators. The OPERA experiment is a hybrid electronic detector/emulsion apparatus, located in the underground Gran Sasso Laboratory, at an average depth of 3800 meters water equivalent (m.w.e.). OPERA is the first large magnetized detector that can measure the muon charge ratio at the LNGS depth, with a wide acceptance for cosmic ray muons coming from above. In this thesis, the muon charge ratio is measured using the spectrometers of the OPERA detector in the highest energy region. The charge ratio was computed separately for single and for multiple muon events, in order to select different primary cosmic ray samples in energy and composition. The measurement as a function of the surface muon energy is used to infer parameters characterizing the particle production in atmosphere, that will be used to constrain Monte Carlo predictions. Finally, the experimental results are interpreted in terms of cosmic ray and particle physics models.
Resumo:
BACKGROUND: Functional magnetic resonance imaging (fMRI) of fluorine-19 allows for the mapping of oxygen partial pressure within perfluorocarbons in the alveolar space (Pao(2)). Theoretically, fMRI-detected Pao(2) can be combined with the Fick principle approach, i.e., a mass balance of oxygen uptake by ventilation and delivery by perfusion, to quantify the ventilation-perfusion ratio (Va/Q) of a lung region: The mixed venous blood and the inspiratory oxygen fraction, which are equal for all lung regions, are measured. In addition, the local expiratory oxygen fraction and the end capillary oxygen content, both of which may differ between the lung regions, are calculated using the fMRI-detected Pao(2). We investigated this approach by numerical simulations and applied it to quantify local Va/Q in the perfluorocarbons during partial liquid ventilation. METHODS: Numerical simulations were performed to analyze the sensitivity of the Va/Q calculation and to compare this approach with another one proposed by Rizi et al. in 2004 (Magn Reson Med 2004;52:65-72). Experimentally, the method was used during partial liquid ventilation in 7 anesthetized pigs. The Pao(2) distribution in intraalveolar perflubron was measured by fluorine-19 MRI. Respiratory gas fractions together with arterial and mixed venous blood samples were taken to quantify oxygen partial pressure and content. Using the Fick principle, the local Va/Q was estimated. The impact of gravity (nondependent versus dependent) of perflubron dose (10 vs 20 mL/kg body weight) and of inspired oxygen fraction (Fio(2)) (0.4-1.0) on Va/Q was examined. RESULTS: In numerical simulations, the Fick principle proved to be appropriate over the Va/Q range from 0.02 to 2.5. Va/Q values were in acceptable agreement with the method published by Rizi et al. In the experimental setting, low mean Va/Q values were found in perflubron (confidence interval [CI] 0.08-0.29 with 20 mL/kg perflubron). At this dose, Va/Q in the nondependent lung was higher (CI 0.18-0.39) than in the dependent lung regions (CI 0.06-0.16; P = 0.006; Student t test). Differences depending on Fio(2) or perflubron dose were, however, small. CONCLUSION: The results show that derivation of Va/Q from local Po(2) measurements using fMRI in perflubron is feasible. The low detected Va/Q suggests that oxygen transport into the perflubron-filled alveolar space is significantly restrained.