999 resultados para Mass Immunization


Relevância:

20.00% 20.00%

Publicador:

Resumo:

D-lactic acid in urine originates mainly from bacterial production in the intestinal tract. Increased D-lactate excretion as observed in patients affected by short bowel syndrome or necrotizing enterocolitis reflects D-lactic overproduction. Therefore, there is a need for a reliable and sensitive method able to detect D-lactic acid even at subclinical elevation levels. A new and highly sensitive method for the simultaneous determination of L- and D-lactic acid by a two-step procedure has been developed. This method is based on the concentration of lactic acid enantiomers from urine by supported liquid extraction followed by high-performance liquid chromatography-tandem mass spectrometry. The separation was achieved by the use of an Astec Chirobiotic? R chiral column under isocratic conditions. The calibration curves were linear over the ranges of 2-400 and 0.5-100 µmol/L respectively for L- and D-lactic acid. The limit of detection of D-lactic acid was 0.125 µmol/L and its limit of quantification was 0.5 µmol/L. The overall accuracy and precision were well within 10% of the nominal values. The developed method is suitable for production of reference values in children and could be applied for accurate routine analysis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To identify common variants influencing body mass index (BMI), we analyzed genome-wide association data from 16,876 individuals of European descent. After previously reported variants in FTO, the strongest association signal (rs17782313, P = 2.9 x 10(-6)) mapped 188 kb downstream of MC4R (melanocortin-4 receptor), mutations of which are the leading cause of monogenic severe childhood-onset obesity. We confirmed the BMI association in 60,352 adults (per-allele effect = 0.05 Z-score units; P = 2.8 x 10(-15)) and 5,988 children aged 7-11 (0.13 Z-score units; P = 1.5 x 10(-8)). In case-control analyses (n = 10,583), the odds for severe childhood obesity reached 1.30 (P = 8.0 x 10(-11)). Furthermore, we observed overtransmission of the risk allele to obese offspring in 660 families (P (pedigree disequilibrium test average; PDT-avg) = 2.4 x 10(-4)). The SNP location and patterns of phenotypic associations are consistent with effects mediated through altered MC4R function. Our findings establish that common variants near MC4R influence fat mass, weight and obesity risk at the population level and reinforce the need for large-scale data integration to identify variants influencing continuous biomedical traits.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Until recently, microbial identification in clinical diagnostic laboratories has mainly relied on conventional phenotypic and gene sequencing identification techniques. The development of matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS) devices has revolutionized the routine identification of microorganisms in clinical microbiology laboratories by introducing an easy, rapid, high throughput, low-cost, and efficient identification technique. This technology has been adapted to the constraint of clinical diagnostic laboratories and has the potential to replace and/or complement conventional identification techniques for both bacterial and fungal strains. Using standardized procedures, the resolution of MALDI-TOF MS allows accurate identification at the species level of most Gram-positive and Gram-negative bacterial strains with the exception of a few difficult strains that require more attention and further development of the method. Similarly, the routine identification by MALDI-TOF MS of yeast isolates is reliable and much quicker than conventional techniques. Recent studies have shown that MALDI-TOF MS has also the potential to accurately identify filamentous fungi and dermatophytes, providing that specific standardized procedures are established for these microorganisms. Moreover, MALDI-TOF MS has been used successfully for microbial typing and identification at the subspecies level, demonstrating that this technology is a potential efficient tool for epidemiological studies and for taxonomical classification.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Agricultural workers are exposed to folpet, but biomonitoring data are limited. Phthalimide (PI), phthalamic acid (PAA), and phthalic acid (PA) are the ring metabolites of this fungicide according to animal studies, but they have not yet been measured in human urine as metabolites of folpet, only PA as a metabolite of phthalates. The objective of this study was thus to develop a reliable gas chromatography-tandem mass spectrometry (GC-MS) method to quantify the sum of PI, PAA, and PA ring-metabolites of folpet in human urine. Briefly, the method consisted of adding p-methylhippuric acid as an internal standard, performing an acid hydrolysis at 100 °C to convert ring-metabolites into PA, purifying samples by ethyl acetate extraction, and derivatizing with N,O-bis(trimethylsilyl)trifluoro acetamide prior to GC-MS analysis. The method had a detection limit of 60.2 nmol/L (10 ng/mL); it was found to be accurate (mean recovery, 97%), precise (inter- and intra-day percentage relative standard deviations <13%), and with a good linearity (R (2) > 0.98). Validation was conducted using unexposed peoples urine spiked at concentrations ranging from 4.0 to 16.1 μmol/L, along with urine samples of volunteers dosed with folpet, and of exposed workers. The method proved to be (1) suitable and accurate to determine the kinetic profile of PA equivalents in the urine of volunteers orally and dermally administered folpet and (2) relevant for the biomonitoring of exposure in workers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This article summarizes the basic principles of mass spectrometry instrumentation with special emphasis in sample introduction methods, ionization techniques and mass analyzers used in the different mass spectrometrytechniques.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this article, selected examples of applications of liquid chromatography coupled to mass spectrometry are given. The examples include the analysis of i) impurities in manufactured, pharmaceutical or synthesis products, ii) polyphenols in natural products, and iii) phytohormones in plant extracts. Finally, examples of applications of molecular characterization via flow injection analysis by electron spray ionization mass spectrometry (ESI-MS) are also given.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This article summarizes the configurations involving isotope ratio mass spectrometry (IRMS) technology available at the CCiTUB and the wide range of possible applications. Some examples of these applications are shown.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This article outlines the basis of the technique and shows some examples of applications in order to exhibit the expectations of this technique invaried scientific fields.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The study of proteins has been a key element in biomedicine and biotechnology because of their important role in cell functions or enzymatic activity. Cells are the basic unit of living organisms, which are governed by a vast range of chemical reactions. These chemical reactions must be highly regulatedin order to achieve homeostasis. Proteins are polymeric molecules that havetaken on the evolutionary process the role, along with other factors, of controlthese chemical reactions. Learning how proteins interact and control their up anddown regulations can teach us how living cells regulate their functions, as well asthe cause of certain anomalies that occur in different diseases where proteins areinvolved. Mass spectrometry (MS) is an analytical widely used technique to studythe protein content inside the cells as a biomarker point, which describesdysfunctions in diseases and increases knowledge of how proteins are working.All the methodologies involved in these descriptions are integrated in the fieldcalled Proteomics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Monthly newsletter for the Iowa Department of Public Health

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Monthly newsletter for the Iowa Department of Public Health

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The end-Permian mass extinction removed more than 80% of marine genera. Ammonoid cephalopods were among the organisms most affected by this crisis. The analysis of a global diversity data set of ammonoid genera covering about 106 million years centered on the Permian-Triassic boundary (PTB) shows that Triassic ammonoids actually reached levels of diversity higher than in the Permian less than 2 million years after the PTB. The data favor a hierarchical rather than logistic model of diversification coupled with a niche incumbency hypothesis. This explosive and nondelayed diversification contrasts with the slow and delayed character of the Triassic biotic recovery as currently illustrated for other, mainly benthic groups such as bivalves and gastropods.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the last two decades, anti-cancer vaccines have yielded disappointing clinical results despite the fact that high numbers of self/tumor-specific T cells can be elicited in immunized patients. Understanding the reasons behind this lack of efficacy is critical in order to design better treatment regimes. Recombinant lentivectors (rLVs) have been successfully used to induce antigen-specific T cells to foreign or mutated tumor antigens. Here, we show that rLV expressing a murine nonmutated self/tumor antigen efficiently primes large numbers of self/tumor-specific CD8(+) T cells. In spite of the large number of tumor-specific T cells, however, no anti-tumor activity could be measured in a therapeutic setting, in mice vaccinated with rLV. Accumulating evidence shows that, in the presence of malignancies, inhibition of T-cell activity may predominate overstimulation. Analysis of tumor-infiltrating lymphocytes revealed that specific anti-tumor CD8(+) T cells fail to produce cytokines and express high levels of inhibitory receptors such as programmed death (PD)-1. Association of active immunization with chemotherapy or antibodies that block inhibitory pathways often leads to better anti-tumor effects. We show here that combining rLV vaccination with either cyclophosphamide or PD-1 and PD-L1 blocking antibodies enhances rLV vaccination efficacy and improves anti-tumor immunity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Immune responses against tumor-associated antigens rely on efficient epitope presentation. The melanoma-associated antigen (Ag) gp100 contains HLA-A*0201 ligands that are characterized by low to medium binding affinity, among which gp100(209-217) is the most prominent (Kawakami et al., J Immunol 154:3961-3968, 1995). While this epitope is a natural T-cell target, it primes with low-efficiency T-cell responses during immunization. A modified gp100 epitope, gp100(209-217T210M), that contains a Thr to Met substitution at position 2 of the antigenic nonamer is characterized by high binding affinity for HLA-A*0201 and elicits strong and clinically effective T-cell responses. This higher affinity is believed to represent the sole reason for enhanced immunogenicity. Contrasting with this observation is the unpredictable relationship between affinity and immunogenicity observed in other antigen systems. In addition, we noted a striking difference between the capability of endogenously processed gp100(209-217) and gp100(209-217T210M) to induce T-cell responses in an in vitro model. Therefore, we questioned whether factors other than HLA-affinity might play a role in determining the immunogenicity of these epitopes. In the present study, we evaluated the in vitro proteasomal cleavages of 23meric precursor peptides encompassing the native sequence (gp100(201-223)) or the modified sequence (gp100(201-223T210M)). Here we show that the standard proteasome liberates the C-termini of both antigenic peptides but not the N-termini. Quantitative analysis of the digestion products revealed that more of the fragments displaying the final C-termini were produced from the wild-type precursor. However, a stronger TCR engagement was observed when fractions of digested gp100(201-223T210M) were used to activate an HLA-A*0201-expressing target T-cell clone. This difference was also found using separately produced, synthetic nonamers. In conclusion, the high binding affinity of gp100(209-217T210M) seems to compensate for possible differences in proteasomal cleavage at the biological level. Since the final antigenic nonamer is not directly produced by the proteasome, additional further factors may influence the antigenic peptide availability, such as post-proteasomal processing and intracellular peptide transport.