911 resultados para IRRADIATED GROUND-BEEF


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work illustrates the advantages of using p-polarized radiation at an incidence angle of 70 degrees in contrast to the conventional unpolarized beam at normal (or near-normal) incidence for the infrared spectroscopic study of polycarbosilane, polysilazane and polysiloxane thin films synthesized by plasma enhanced chemical vapor deposition (PECVD) and subsequently irradiated with 170 keV He+ ions at fluences from 1 x 10(14) to 1 x 10(16) cm(-2). Several bands not seen using the conventional mode could be observed in the polarized mode. (c) 2006 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Twenty eight Mediterranean buffaloes bulls were scanned with real-time ultrasound (RTU), slaughtered, and fabricated into retail cuts to determine the potential for ultrasound measures to predict carcass retail yield. Ultrasound measures of fat thickness, ribeye area and rump fat thickness were recorded three to five days prior to slaughter. Carcass measurements were taken, and one side of each carcass was fabricated into retail cuts. Stepwise regression analysis was used to compare possible models for prediction of either kilograms or percent retail product from carcass mesaurements and ultrasound measures. Results indicate that possible prediction models for percent or kilograms of retail products using RTU measures were similar in their predictive power and accuracy when compared to models derived from carcass measurements. Both fat thickness and ribeye area were over-predicted when measured ultrasonically compared to measurements taken on the carcass in the cooler. The mean absolute differences for both traits are larger than the mean differences, indicating that some images were interpreted to be larger and some smaller than actual carcass measurements. Ultrasound measurements of REA and FT had positive correlations with carcass measures of the same traits (r=.96 for REA and r=.99 for FT). Standard errors of prediction currently are being used as the standard to certify ultrasound technicians for accuracy. Regression equations using live weight (LW), rib eye area (REAU) and subcutaneous fat thickness (FTU) between 12(th) and 13 (th) ribs and also over the biceps femoris muscle (FTP8) by ultrasound explained 95% of the variation in the hot carcass weight when measure immediately before slaughter.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Initially this paper shows the ground wire reduction process for generic multiphase transmission lines and after, the ground wire reduction process for a specilic 440-kV three-phase overhead transmission line. Following this, the influence of the ground wire reduction process considering two situations is shown: first, considering frequency independence and second, when these parameters are considered as frequency dependent. This paper presents analytical results for generic multiphase transmission lines. For a specific 440-kV three-phase overhead transmission line, analytical and graphic results are shown considering real data for every frequency between 10 Hz and 1 MHz.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fast transient current decay was recorded on POMA samples during current pulses (in the order of milliseconds) provided by a low energy electron beam under an applied field. The characteristic time decay depends on the electron beam energy and on the bias polarity. The results were explained taking into account the effect of space charge, the intrinsic conductivity of the non-irradiated region of the sample and the radiation-induced conductivity of the thin irradiated region. Fitting parameters may provide the value of both intrinsic and radiation-induced conductivities and the average electron range.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

It is shown that for singular potentials of the form lambda/r(alpha),the asymptotic form of the wave function both at r --> infinity and r --> 0 plays an important role. Using a wave function having the correct asymptotic behavior for the potential lambda/r(4), it is, shown that it gives the exact ground-state energy for this potential when lambda --> 0, as given earlier by Harrell [Ann. Phys. (NY) 105, 379 (1977)]. For other values of the coupling parameter X, a trial basis;set of wave functions which also satisfy the correct boundary conditions at r --> infinity and r --> 0 are used to find the ground-state energy of the singular potential lambda/r(4) It is shown that the obtained eigenvalues are in excellent agreement with their exact ones for a very large range of lambda values.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The identification of ground control on photographs or images is usually carried out by a human operator, who uses his natural skills to make interpretations. In Digital Photogrammetry, which uses techniques of digital image processing extraction of ground control can be automated by using an approach based on relational matching and a heuristic that uses the analytical relation between straight features of object space and its homologous in the image space. A build-in self-diagnosis is also used in this method. It is based on implementation of data snooping statistic test in the process of spatial resection using the Iterated Extended Kalman Filtering (IEKF). The aim of this paper is to present the basic principles of the proposed approach and results based on real data.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

When the carious tissue is eliminated either by conventional methods (with burs) or with lasers, the risk of accidentally damage the surface of adjacent teeth may occur, which hypothetically could lead to a more susceptible surface for canes formation. This in vitro study aims to evaluate the caries resistance of the dental enamel surface irradiated by the Nd:YAG laser applied in conditions simulating accidental exposition. Thirteen third molars were used in this study. The experimental groups were: G1: sound control and control + carious; G2: contact Nd:YAG laser at 0.75, 1, 2, or 3 W; 10 Hz; 3 sec (27, 35, 71, and 106 J/cm(2)); G3: same parameters from G2 + caries artificial induction through the demineralization and demineralization (DES/RE) dynamic model. The caries resistance analysis was evaluated by the superficial morphological aspect through SEM images and also by Ca/P proportion through energy dispersive X-ray spectroscopy (EDX). The micrograph images showed that the Nd:YAG laser changed the normalmorphology of the enamel prisms resulting in a melted and re-solidified surface intensified with the power increase. Significant statistical differences were observed applying the Kruskal-Wallis statistical test (p <= 0.01) among the Nd:YAG laser irradiated groups and the control with caries regarding the Ca/P proportion. As an exception, this was not observed when 3 W; 10 Hz; 3 sec; 106 J/cm(2) was applied and posteriously submitted to a cariogenic challenge. The results indicate that the Nd:YAG laser accidental irradiation at low power settings did not represent risks to the enamel caries resistance.