950 resultados para General Electric Company


Relevância:

30.00% 30.00%

Publicador:

Resumo:

A tanulmány az aukciós villamosenergia-tőzsdéken kialakuló óránkénti árak statisztikai jellemzőivel foglalkozik. Célja, hogy egyes legújabb kutatási eredmények alapján új megvilágításban mutassa be a villamos energia óránkénti árára jellemző főbb megállapításokat, amelyek a későbbiekben az ár modellezésének alapjául szolgálhatnak. A jelenségeket az EEX és Nord Pool áramtőzsdén kereskedett termékek árainak adatain szemlélteti. Látni fogjuk, hogy át kell értékelnünk több, a villamosenergia-árak statisztikai viselkedéséről alkotott meggondolást. / === / The article concerns the statistical features of the hourly prices on auction-based markets for electric power. The purpose is to use the latest research findings to present the main statements about the hourly price for electric power in a new light, so that they can serve later as a basis for price modelling. The phenomena are viewed through the price data of products traded on the EEX and Nord Pool power exchanges. It emerges that several ideas about the statistical behaviour of electric power prices have to be reviewed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

General note: Title and date provided by Bettye Lane.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Les ouvrages de transport d’électricité ont d’abord été pensés un par un, reliant un excédent de production à un besoin de consommation. Ils ont ainsi parfois très naturellement et dès l’origine traversé les frontières des États pour répondre à leur raison d’être. Les secteurs électriques se structurant fortement lorsque le virage électrique fut pris, les interconnexions entre pays furent conçues par les techniciens comme une mesure élémentaire de sûreté et d’équilibre de ce produit atypique qu’est l’électricité. En France plus particulièrement, lorsque la production électronucléaire se développa à partir des années 1970, ces interconnexions devinrent petit à petit sources de revenus pour l’entreprise nationale, et d’équilibre pour la balance commerciale nationale. L’intérêt grandissant porté au secteur électrique par les institutions européennes à la fin des années 1990 vient ébranler les acteurs économiques géographiques verticaux, et rebat les cartes des enjeux à adresser à une maille plus large que l’État nation. Dans ces transformations successives, les interconnexions aux frontières, et particulièrement aux frontières françaises, jouent ainsi un rôle tout à fait spécifique et de plus en plus structurant pour les économies ouvertes des pays européens. Les réseaux de transport électriques continuent ainsi une mutation entamée dans les années 1970 qui les a conduits de la condition de mal nécessaire à celle de vecteurs indispensables de transformation des économies européennes. L’objet de ce mémoire est d’illustrer la très grande capacité d’adaptation de ces organes industriels, économiques, sociétaux et politiques, dont on pourrait faussement penser qu’ils sont immobilisés par leur nature capitalistique, à travers les enjeux portés par les interconnexions aux frontières françaises. Les sources sont à la fois issues de données des opérateurs techniques, de la documentation – encore peu fréquente – sur ces sujets, ainsi que des statistiques officielles du ministère français. Cette capacité d’innovation et de développement de « couches de services » permet aujourd’hui aux grands réseaux de transport de traverser les époques et la variabilité des orientations de leurs environnements, durablement.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Underground hardrock mining can be very energy intensive and in large part this can be attributed to the power consumption of underground ventilation systems. In general, the power consumed by a mine’s ventilation system and its overall scale are closely related to the amount of diesel power in operation. This is because diesel exhaust is a major source of underground air pollution, including diesel particulate matter (DPM), NO2 and heat, and because regulations tie air volumes to diesel engines. Furthermore, assuming the size of airways remains constant, the power consumption of the main system increases exponentially with the volume of air supplied to the mine. Therefore large diesel fleets lead to increased energy consumption and can also necessitate large capital expenditures on ventilation infrastructure in order to manage power requirements. Meeting ventilation requirements for equipment in a heading can result in a similar scenario with the biggest pieces leading to higher energy consumption and potentially necessitating larger ventilation tubing and taller drifts. Depending on the climate where the mine is located, large volumes of air can have a third impact on ventilation costs if heating or cooling the air is necessary. Annual heating and cooling costs, as well as the cost of the associated infrastructure, are directly related to the volume of air sent underground. This thesis considers electric mining equipment as a means for reducing the intensity and cost of energy consumption at underground, hardrock mines. Potentially, electric equipment could greatly reduce the volume of air needed to ventilate an entire mine as well as individual headings because they do not emit many of the contaminants found in diesel exhaust and because regulations do not connect air volumes to electric motors. Because of the exponential relationship between power consumption and air volumes, this could greatly reduce the amount of power required for mine ventilation as well as the capital cost of ventilation infrastructure. As heating and cooling costs are also directly linked to air volumes, the cost and energy intensity of heating and cooling the air would also be significantly reduced. A further incentive is that powering equipment from the grid is substantially cheaper than fuelling them with diesel and can also produce far fewer GHGs. Therefore, by eliminating diesel from the underground workers will enjoy safer working conditions and operators and society at large will gain from a smaller impact on the environment. Despite their significant potential, in order to produce a credible economic assessment of electric mining equipment their impact on underground systems must be understood and considered in their evaluation. Accordingly, a good deal of this thesis reviews technical considerations related to the use of electric mining equipment, especially ones that impact the economics of their implementation. The goal of this thesis will then be to present the economic potential of implementing the equipment, as well as to outline the key inputs which are necessary to support an evaluation and to provide a model and an approach which can be used by others if the relevant information is available and acceptable assumptions can be made.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Les ouvrages de transport d’électricité ont d’abord été pensés un par un, reliant un excédent de production à un besoin de consommation. Ils ont ainsi parfois très naturellement et dès l’origine traversé les frontières des États pour répondre à leur raison d’être. Les secteurs électriques se structurant fortement lorsque le virage électrique fut pris, les interconnexions entre pays furent conçues par les techniciens comme une mesure élémentaire de sûreté et d’équilibre de ce produit atypique qu’est l’électricité. En France plus particulièrement, lorsque la production électronucléaire se développa à partir des années 1970, ces interconnexions devinrent petit à petit sources de revenus pour l’entreprise nationale, et d’équilibre pour la balance commerciale nationale. L’intérêt grandissant porté au secteur électrique par les institutions européennes à la fin des années 1990 vient ébranler les acteurs économiques géographiques verticaux, et rebat les cartes des enjeux à adresser à une maille plus large que l’État nation. Dans ces transformations successives, les interconnexions aux frontières, et particulièrement aux frontières françaises, jouent ainsi un rôle tout à fait spécifique et de plus en plus structurant pour les économies ouvertes des pays européens. Les réseaux de transport électriques continuent ainsi une mutation entamée dans les années 1970 qui les a conduits de la condition de mal nécessaire à celle de vecteurs indispensables de transformation des économies européennes. L’objet de ce mémoire est d’illustrer la très grande capacité d’adaptation de ces organes industriels, économiques, sociétaux et politiques, dont on pourrait faussement penser qu’ils sont immobilisés par leur nature capitalistique, à travers les enjeux portés par les interconnexions aux frontières françaises. Les sources sont à la fois issues de données des opérateurs techniques, de la documentation – encore peu fréquente – sur ces sujets, ainsi que des statistiques officielles du ministère français. Cette capacité d’innovation et de développement de « couches de services » permet aujourd’hui aux grands réseaux de transport de traverser les époques et la variabilité des orientations de leurs environnements, durablement.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Two trends are emerging from modern electric power systems: the growth of renewable (e.g., solar and wind) generation, and the integration of information technologies and advanced power electronics. The former introduces large, rapid, and random fluctuations in power supply, demand, frequency, and voltage, which become a major challenge for real-time operation of power systems. The latter creates a tremendous number of controllable intelligent endpoints such as smart buildings and appliances, electric vehicles, energy storage devices, and power electronic devices that can sense, compute, communicate, and actuate. Most of these endpoints are distributed on the load side of power systems, in contrast to traditional control resources such as centralized bulk generators. This thesis focuses on controlling power systems in real time, using these load side resources. Specifically, it studies two problems.

(1) Distributed load-side frequency control: We establish a mathematical framework to design distributed frequency control algorithms for flexible electric loads. In this framework, we formulate a category of optimization problems, called optimal load control (OLC), to incorporate the goals of frequency control, such as balancing power supply and demand, restoring frequency to its nominal value, restoring inter-area power flows, etc., in a way that minimizes total disutility for the loads to participate in frequency control by deviating from their nominal power usage. By exploiting distributed algorithms to solve OLC and analyzing convergence of these algorithms, we design distributed load-side controllers and prove stability of closed-loop power systems governed by these controllers. This general framework is adapted and applied to different types of power systems described by different models, or to achieve different levels of control goals under different operation scenarios. We first consider a dynamically coherent power system which can be equivalently modeled with a single synchronous machine. We then extend our framework to a multi-machine power network, where we consider primary and secondary frequency controls, linear and nonlinear power flow models, and the interactions between generator dynamics and load control.

(2) Two-timescale voltage control: The voltage of a power distribution system must be maintained closely around its nominal value in real time, even in the presence of highly volatile power supply or demand. For this purpose, we jointly control two types of reactive power sources: a capacitor operating at a slow timescale, and a power electronic device, such as a smart inverter or a D-STATCOM, operating at a fast timescale. Their control actions are solved from optimal power flow problems at two timescales. Specifically, the slow-timescale problem is a chance-constrained optimization, which minimizes power loss and regulates the voltage at the current time instant while limiting the probability of future voltage violations due to stochastic changes in power supply or demand. This control framework forms the basis of an optimal sizing problem, which determines the installation capacities of the control devices by minimizing the sum of power loss and capital cost. We develop computationally efficient heuristics to solve the optimal sizing problem and implement real-time control. Numerical experiments show that the proposed sizing and control schemes significantly improve the reliability of voltage control with a moderate increase in cost.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper presents a load frequency control scheme using electric vehicles (EVs) to help thermal turbine units to provide the stability fluctuated by load demands. First, a general framework for deriving a state-space model for general power system topologies is given. Then, a detailed model of a four-area power system incorporating a smart and renewable discharged EVs system is presented. The areas within the system are interconnected via a combination of alternating current/high voltage direct current links and thyristor controlled phase shifters. Based on some recent development on functional observers, novel distributed functional observers are designed, one at each local area, to implement any given global state feedback controller. The designed observers are of reduced order and dynamically decoupled from others in contrast to conventional centralized observer (CO)-based controllers. The proposed scheme can cope better against accidental failures than those CO-based controllers. Extensive simulations and comparisons are given to show the effectiveness of the proposed control scheme.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: To evaluate the impact of a lifestyle intervention in Australian general practice to reduce the risk of vascular disease.

Design, setting and participants: Stratified cluster randomised controlled trial among 30 general practices in New South Wales from July 2008 to January 2010. Patients aged 40–64 years were invited to participate. The subgroup who were 40–55 years of age were included only if they had either hypertension or dyslipidaemia.

Intervention: A general practice-based health-check with brief lifestyle counselling and referral of high-risk patients to a program consisting of one to two individual visits with an exercise physiologist or dietitian, and six group sessions.

Main outcome measures: Outcomes at baseline, 6 and 12 months included the behavioural and physiological risk factors for vascular disease — self-reported diet and physical activity, and measured weight, body mass index, waist circumference, blood lipid and blood sugar levels, and blood pressure.

Results: Of the 3128 patients who were invited, 958 patients (30.6%) responded and 814 were eligible to participate. Of these, 699 commenced the study, and 655 remained in the study at 12 months. Physical activity levels increased to a greater extent in the intervention group than the control group at 6 and 12 months (P = 0.005). There were no other changes in behavioural or physiological outcomes or in estimated absolute risk of cardiovascular disease at 12 months. Of the 384 enrolled in the intervention group, 117 patients (30.5%) attended the minimum number of group program sessions and lost more weight (mean weight loss, 1.06 kg) than those who did not attend the minimum number of sessions (mean weight gain, 0.73 kg).

Conclusion: While patients who received counselling by their general practitioner increased self-reported physical activity, only those who attended the group sessions sustained an improvement in weight. However, more research is needed to determine whether group programs offer significant benefits over individual counselling in general practice.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

company is legally incorporated it must be treated like any other independent person with its rightsand liabilities appropriate to itself”.2 A consequence of this is the “proper plaintiff” principleestablished in Foss v Harbottle (1843) 2 Hare 461; 67 ER 189: the proper plaintiff in an action inrespect of a wrong done to a corporation is the corporation itself.3 It is also a “hallowed rule” thatdirectors owe their duties to the company, not the shareholders,4 and so any loss accruing to thecompany as a result of the directors’ breach of their duties is recoverable only by the company.5An obvious problem with this state of affairs is that a company will be unlikely to initiateproceedings against its directors when the company is controlled by those directors.6 While there aregood economic reasons for this division of management and ownership,7 shareholders are left with acritical question: under what circumstances can they initiate proceedings to recover loss suffered as aresult of company directors’ breach of their duties? Although one writer has referred to the“expansive statutory and common law arsenals” available to aggrieved shareholders,8 it seems ratherthe case that there are few effective remedies. For shareholders have no contractual relationship withdirectors,9 and the personal rights conferred on shareholders by statute or general law are largelyprocedural10 and seem a rather ineffective basis for “scrutinising directorial performance”.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The purpose of this research is to examine the role of the mining company office in the management of the copper industry in Michigan’s Keweenaw Peninsula between 1901 and 1946. Two of the largest and most influential companies were examined – the Calumet & Hecla Mining Company and the Quincy Mining Company. Both companies operated for more than forty years under general managers who were arguably the most influential people in the management of each company. James MacNaughton, general manager at Calumet and Hecla, worked from 1901 through 1941; Charles Lawton, general manager at Quincy Mining Company, worked from 1905 through 1946. In this case, both of these managers were college-educated engineers and adopted scientific management techniques to operate their respective companies. This research focused on two main goals. The first goal of this project was to address the managerial changes in Michigan’s copper mining offices of the early twentieth century. This included the work of MacNaughton and Lawton, along with analysis of the office structures themselves and what changes occurred through time. The second goal of the project was to create a prototype virtual exhibit for use at the Quincy Mining Company office. A virtual exhibit will allow visitors the opportunity to visit the office virtually, experiencing the office as an office worker would have in the early twentieth century. To meet both goals, this project used various research materials, including archival sources, oral histories, and material culture to recreate the history of mining company management in the Copper Country.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introducción: El dolor lumbar y los desórdenes músculo esqueléticos comprometen la salud y la calidad de vida de los trabajadores, pueden poner en riesgo el futuro laboral de las personas. bjetivo: Estimar la prevalencia de dolor lumbar y los posibles factores biomecánicos asociados en el personal operativo y administrativo en una empresa manufacturera de jabón en Bogotá, en el año 2016 Metodología: Estudio de corte transversal donde se evaluó el riesgo biomecánico y la prevalencia del dolor lumbar en personal administrativo (138) y operativo (165); se utilizó como instrumento el ERGOPAR validado en España. Se revisó la asociación utilizando la prueba Chi Cuadrado de Pearson, con un nivel de significación α 0.05 Resultados: 303 trabajadores de una empresa manufacturera de jabón en Bogotá, donde predominó el género masculino (51,82%) y la población adulta media entre 30-39 años (57,42%). La prevalencia del dolor lumbar en la población fue de 61,39% (186). La edad no se asoció estadísticamente al dolor lumbar. Se encontró asociación estadística entre el síntoma dolor lumbar y extensión de cuello (p=0,05 OR1.95 IC 1.33-2.88), así como con agarrar o sujetar objetos (p= 0,036. OR 2.3 IC 1.59-3.51) y con las exigencias físicas laborales (p= 0.001 OR 1.99 IC 1.31-3.02). Conclusiones: La población estudiada presentó una alta prevalencia de dolor lumbar, con predominio en personal que realiza labores operativas, y del género femenino. La adopción de posturas de extensión del cuello y la sujeción o agarre de objetos son factores asociados directamente con la aparición de lumbalgia.