776 resultados para Electric capacity.
Resumo:
The main objective of this thesis is to develop a compact chipless RFID tag with high data encoding capacity. The design and development of chipless RFID tag based on multiresonator and multiscatterer methods are presented first. An RFID tag using using SIR capable of 79bits is proposed. The thesis also deals with some of the properties of SIR like harmonic separation, independent control on resonant modes and the capability to change the electrical length. A chipless RFID reader working in a frequency band of 2.36GHz to 2.54GHz has been designed to show the feasibility of the RFID system. For a practical system, a new approach based on UWB Impulse Radar (UWB IR) technology is employed and the decoding methods from noisy backscattered signal are successfully demonstrated. The thesis also proposes a simple calibration procedure, which is able to decode the backscattered signal up to a distance of 80cm with 1mW output power.
Resumo:
Transport of live aquatic organisms which is more than a century old, perhaps started in the 1870's (Norris et al, 1960). Live fish transportation is an essential practice in aquaculture particularly in rural areas of developing countries representing the only means of supplying fry to small scale aqua culturists (Taylor and Ross, 1988). Very often, large numbers of fry, fingerlings, juveniles and adult fish are being transported from the hatchery to fish farms, fish farms to market, processors and consumers. Live fish command large economic importance in the fresh fish market than dead and iced fish. Medina Pizzali (2001) observed that live fish in the Kolkata market was usually sold at higher prices than dead fish and most consumers were prepared to pay premium prices for live fish, which is considered as the best guarantee of freshness, quality, and intrinsic characteristics of its flesh (better texture and delicate flavour) in comparison with fresh/chilled seafood. Various government and private agencies undertake transport of live fish for commercial live fish market or for artificial propagation of game
Resumo:
Singularities of elastic and electric fields are investigated at the tip of a crack on the interface of two anisotropic piezo-electric media under various boundary conditions on the crack surfaces. The Griffith formulae are obtained for increments of energy functionals due to growth of the crack and the notion of the energy release matrix is introduced. Normalization conditions for bases of singular solution are proposed to adapt them to the energy, stress, and deformation fracture criteria. Connections between these bases are determined and additional properties of the deformation basis related to the notion of electric surface enthalpy are established.
Resumo:
Eurocode 8 representing a new generation of structural design codes in Europe defines requirements for the design of buildings against earthquake action. In Central and Western Europe, the newly defined earthquake zones and corresponding design ground acceleration values, will lead in many cases to earthquake actions which are remarkably higher than those defined so far by the design codes used until now in Central Europe. In many cases, the weak points of masonry structures during an earthquake are the corner regions of the walls. Loading of masonry walls by earthquake action leads in most cases to high shear forces. The corresponding bending moment in such a wall typically causes a significant increase of the eccentricity of the normal force in the critical wall cross section. This in turn leads ultimately to a reduction of the size of the compression zone in unreinforced walls and a high concentration of normal stresses and shear stresses in the corner regions. Corner-Gap-Elements, consisting of a bearing beam located underneath the wall and made of a sufficiently strong material (such as reinforced concrete), reduce the effect of the eccentricity of the normal force and thus restricts the pinching effect of the compression zone. In fact, the deformation can be concentrated in the joint below the bearing beam. According to the principles of the Capacity Design philosophy, the masonry itself is protected from high stresses as a potential cause of brittle failure. Shaking table tests at the NTU Athens Earthquake Engineering Laboratory have proven the effectiveness of the Corner-Gap-Element. The following presentation will cover the evaluation of various experimental results as well as a numerical modeling of the observed phenomena.
Resumo:
It is found that the electric dipole polarizabilities of neutral atoms correlate very strongly with their first ionization potential within the groups of elements with the same angular momenta of the outermost electrons. As the latter values are known very accurately, this allows a very good (<30%) prediction of various atomic polarizabilities.
Resumo:
In dieser Arbeit wurde ein gemischt-ganzzahliges lineares Einsatzoptimierungsmodell für Kraftwerke und Speicher aufgebaut und für die Untersuchung der Energieversorgung Deutschlands im Jahre 2050 gemäß den Leitstudie-Szenarien 2050 A und 2050 C ([Nitsch und Andere, 2012]) verwendet, in denen erneuerbare Energien einen Anteil von über 85 % an der Stromerzeugung haben und die Wind- und Solarenergie starke Schwankungen der durch steuerbare Kraftwerke und Speicher zu deckenden residualen Stromnachfrage (Residuallast) verursachen. In Szenario 2050 A sind 67 TWh Wasserstoff, die elektrolytisch aus erneuerbarem Strom zu erzeugen sind, für den Verkehr vorgesehen. In Szenario 2050 C ist kein Wasserstoff für den Verkehr vorgesehen und die effizientere Elektromobilität hat einen Anteil von 100% am Individualverkehr. Daher wird weniger erneuerbarer Strom zur Erreichung desselben erneuerbaren Anteils im Verkehrssektor benötigt. Da desweiteren Elektrofahrzeuge Lastmanagementpotentiale bieten, weisen die Residuallasten der Szenarien eine unterschiedliche zeitliche Charakteristik und Jahressumme auf. Der Schwerpunkt der Betrachtung lag auf der Ermittlung der Auslastung und Fahrweise des in den Szenarien unterstellten ’Kraftwerks’-parks bestehend aus Kraftwerken zur reinen Stromerzeugung, Kraft-Wärme-Kopplungskraftwerken, die mit Wärmespeichern, elektrischen Heizstäben und Gas-Backupkesseln ausgestattet sind, Stromspeichern und Wärmepumpen, die durch Wärmespeicher zum Lastmanagment eingesetzt werden können. Der Fahrplan dieser Komponenten wurde auf minimale variable Gesamtkosten der Strom- und Wärmeerzeugung über einen Planungshorizont von jeweils vier Tagen hin optimiert. Das Optimierungsproblem wurde mit dem linearen Branch-and-Cut-Solver der software CPLEX gelöst. Mittels sogenannter rollierender Planung wurde durch Zusammensetzen der Planungsergebnisse für überlappende Planungsperioden der Kraftwerks- und Speichereinsatz für die kompletten Szenariojahre erhalten. Es wurde gezeigt, dass der KWK-Anteil an der Wärmelastdeckung gering ist. Dies wurde begründet durch die zeitliche Struktur der Stromresiduallast, die wärmeseitige Dimensionierung der Anlagen und die Tatsache, dass nur eine kurzfristige Speicherung von Wärme vorgesehen war. Die wärmeseitige Dimensionierung der KWK stellte eine Begrenzung des Deckungsanteils dar, da im Winter bei hoher Stromresiduallast nur wenig freie Leistung zur Beladung der Speicher zur Verfügung stand. In den Berechnungen für das Szenario 2050 A und C lag der mittlere Deckungsanteil der KWK an der Wärmenachfrage von ca. 100 TWh_th bei 40 bzw. 60 %, obwohl die Auslegung der KWK einen theoretischen Anteil von über 97 % an der Wärmelastdeckung erlaubt hätte, gäbe es die Beschränkungen durch die Stromseite nicht. Desweiteren wurde die CO2-Vermeidungswirkung der KWK-Wärmespeicher und des Lastmanagements mit Wärmepumpen untersucht. In Szenario 2050 A ergab sich keine signifikante CO2-Vermeidungswirkung der KWK-Wärmespeicher, in Szenario 2050 C hingegen ergab sich eine geringe aber signifikante CO2-Einsparung in Höhe von 1,6 % der Gesamtemissionen der Stromerzeugung und KWK-gebundenen Wärmeversorgung. Das Lastmanagement mit Wärmepumpen vermied Emissionen von 110 Tausend Tonnen CO2 (0,4 % der Gesamtemissionen) in Szenario A und 213 Tausend Tonnen in Szenario C (0,8 % der Gesamtemissionen). Es wurden darüber hinaus Betrachtungen zur Konkurrenz zwischen solarthermischer Nahwärme und KWK bei Einspeisung in dieselben Wärmenetze vorgenommen. Eine weitere Einschränkung der KWK-Erzeugung durch den Einspeisevorrang der Solarthermie wurde festgestellt. Ferner wurde eine untere Grenze von 6,5 bzw. 8,8 TWh_th für die in den Szenarien mindestens benötigte Wasserstoff-Speicherkapazität ermittelt. Die Ergebnisse dieser Arbeit legen nahe, das technisch-ökonomische Potential von Langzeitwärmespeichern für eine bessere Integration von KWK ins System zu ermitteln bzw. generell nach geeigneteren Wärmesektorszenarien zu suchen, da deutlich wurde, dass für die öffentliche Wärmeversorgung die KWK in Kombination mit Kurzzeitwärmespeicherung, Gaskesseln und elektrischen Heizern keine sehr effektive CO2 -Reduktion in den Szenarien erreicht. Es sollte dabei z.B. untersucht werden, ob ein multivalentes System aus KWK, Wärmespeichern und Wärmepumpen eine ökonomisch darstellbare Alternative sein könnte und im Anschluss eine Betrachtung der optimalen Anteile von KWK, Wärmepumpen und Solarthermie im Wärmemarkt vorgenommen werden.
Resumo:
This research quantitatively evaluates the water retention capacity and flood control function of the forest catchments by using hydrological data of the large flood events which happened after the serious droughts. The objective sites are the Oodo Dam and the Sameura Dam catchments in Japan. The kinematic wave model, which considers saturated and unsaturated sub-surface soil zones, is used for the rainfall-runoff analysis. The result shows that possible storage volume of the Oodo Dam catchment is 162.26 MCM in 2005, while that of Samerua is 102.83 MCM in 2005 and 102.64 MCM in 2007. Flood control function of the Oodo Dam catchment is 173 mm in water depth in 2005, while the Sameura Dam catchment 114 mm in 2005 and 126 mm in 2007. This indicates that the Oodo Dam catchment has more than twice as big water capacity as its capacity (78.4 mm), while the Sameura Dam catchment has about one-fifth of the its storage capacity (693 mm).
Resumo:
The challenge of reducing carbon emission and achieving emission target until 2050, has become a key development strategy of energy distribution for each country. The automotive industries, as the important portion of implementing energy requirements, are making some related researches to meet energy requirements and customer requirements. For modern energy requirements, it should be clean, green and renewable. For customer requirements, it should be economic, reliable and long life time. Regarding increasing requirements on the market and enlarged customer quantity, EVs and PHEV are more and more important for automotive manufactures. Normally for EVs and PHEV there are two important key parts, which are battery package and power electronics composing of critical components. A rechargeable battery is a quite important element for achieving cost competitiveness, which is mainly used to story energy and provide continue energy to drive an electric motor. In order to recharge battery and drive the electric motor, power electronics group is an essential bridge to convert different energy types for both of them. In modern power electronics there are many different topologies such as non-isolated and isolated power converters which can be used to implement for charging battery. One of most used converter topology is multiphase interleaved power converter, pri- marily due to its prominent advantages, which is frequently employed to obtain optimal dynamic response, high effciency and compact converter size. Concerning its usage, many detailed investigations regarding topology, control strategy and devices have been done. In this thesis, the core research is to investigate some branched contents in term of issues analysis and optimization approaches of building magnetic component. This work starts with an introduction of reasons of developing EVs and PEHV and an overview of different possible topologies regarding specific application requirements. Because of less components, high reliability, high effciency and also no special safety requirement, non-isolated multiphase interleaved converter is selected as the basic research topology of founded W-charge project for investigating its advantages and potential branches on using optimized magnetic components. Following, all those proposed aspects and approaches are investigated and analyzed in details in order to verify constrains and advantages through using integrated coupled inductors. Furthermore, digital controller concept and a novel tapped-inductor topology is proposed for multiphase power converter and electric vehicle application.
Resumo:
This paper focus on the problem of locating single-phase faults in mixed distribution electric systems, with overhead lines and underground cables, using voltage and current measurements at the sending-end and sequence model of the network. Since calculating series impedance for underground cables is not as simple as in the case of overhead lines, the paper proposes a methodology to obtain an estimation of zero-sequence impedance of underground cables starting from previous single-faults occurred in the system, in which an electric arc occurred at the fault location. For this reason, the signal is previously pretreated to eliminate its peaks voltage and the analysis can be done working with a signal as close as a sinus wave as possible
Resumo:
En el área de Abastecimiento de CEMEX COLOMBIA SA se encuentra el foco de las negociaciones con proveedores de la empresa. Es en esta área donde se realizan contratos a largo plazo con las empresas que suministran los insumos vitales para la producción de cemento y concreto. Uno de estos insumos es la energía eléctrica. Necesaria en todo proceso productivo, la energía eléctrica se convierte, entonces, en una de las negociaciones más críticas para la empresa teniendo en cuenta el impacto en la operación y en el gasto. De igual forma, toda negociación requiere de un estudio riguroso previo por medio del cual se llegue a una postura informada al momento de negociar. Es así como CEMEX COLOMBIA SA, a través de sus negociadores, se prepara investigando el mercado nacional y regional de energía eléctrica, sus variables influyentes y las proyecciones de desarrollo. Luego de esta investigación y del análisis del sector, CEMEX COLOMBIA SA asume una posición firme en la que sabe que los planes de expansión y el desarrollo esperado del sector plantean un mercado con capacidad instalada suficiente para el suministro de energía hasta 2017. De esta manera, se cierra un contrato a dos años con Emgesa, filial de la multinacional española Endesa.
Resumo:
Aim: Examine the relationship between the functional capacity and the quality of life related to health in university workers. Methodology: Cross-sectional study in 146 subjects, divided in two groups: Low functional Capacity (< 9 METs) and High functional Capacity (> 9.1 METs). We evaluated quality of life related to health (HRQOL-Health Questionnaire SF-12) and functional capacity (Questionnaire PAR/PAF) as indicators of health status. Results: 47.3% (69 men) and 52.7% (78 women). The average age of the groups was 35.0 ± 9.7 years (range 19,0-60,0 years). For HRQOL, the average found in the population assessed was 45.2 ± 4.42 (range 33,0-58,1) and 43.8 ± 6.87 (range 19,8-43,8) in components Physical Component Summary (PCS-12) and Mental Component Summary (MCS-12), respectively p = NS. Significant differences were found when comparing functional ability and sex, p<0,001 in both groups. Similarly, sex and mental component MCS-12 (group of Lower Functional) p = 0,049 as well as women and the physical component PCS-12, p = 0,05 between groups. Finally, a better score in HRQL observed in the group of High Capacity and functional components in both sex OR 0.59 (0.25-1.38). Conclusions: The results of this study demonstrate the relationship between High functional Capacity and a better HRQOL in this population.
Productivity growth in electric energy retail in Colombia. A bootstrapped malmquist indices approach
Resumo:
This paper offers a productivity growth estimate for electric energy commercialization firms in Colombia, using a non-parametric Malmquist bootstrap methodology. The estimation and methodology serve two main purposes. First, in Colombia Commercialization firms are subject to a price-cap regulation scheme, a non-common arrangement in the international experience for this part of the industry. Therefore the paper’s result suggest an estimate of the productivity factor to be used by the regulator, not only in Colombia but in other countries where commercialization is a growing part of the industry (renewable energy, for instance). Second, because of poor data collection from regulators and firms themselves, regulation based on a single estimation of productivity seems inappropriate and error-prone. The nonparametric Malmquist bootstrap estimation allows an assessment of the result in contrast to a single one estimation. This would open an opportunity for the regulator to adopt a narrower and more accurate productivity estimation or override an implausible result and impose a productivity factor in the price-cap to foster the development of the industry.
Resumo:
This paper analyzes some optimal fiscal, pricing, and capacity investment policies for controlling regional monopoly power in the natural gas industry. By letting the set of control instruments available to the social planner vary, we provide a characterization of the technological and demand conditions under which “excess” capacity in the transport network arises in response to the loss of the two other control instruments, namely, transfers and pricing. Hence, the analysis yields some insights on an economy’s incentives to invest in infrastructures for the purpose of integrating geographically isolated markets.
Resumo:
This paper develops a model of the regulator-regulated firm relationship in a regional natural gas commodity market which can be linked to a competitive market by a pipeline. We characterize normative policies under which the regulator, in addition to setting the level of the capacity of the pipeline, regulates the price of gas, under asymmetric information on the firm’s technology, and may (or may not) operate (two-way) transfers between consumers and the firm. We then focus on capacity and investigate how its level responds to the regulator’s taking account of the firm’s incentive compatibility constraints. The analysis yields some insights on the role that transport capacity investments may play as an instrument to improve the efficiency of geographically isolated markets.