978 resultados para Cosine coefficient


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective To investigate whether standardization of the multiplanar view (SMV) when evaluating the uterus using three-dimensional ultrasonography (3D-US) improves intra-and interobserver reliability and agreement with regard to endometrial measurement. Methods Two-dimensional (2D) and 3D-US was used to measure endometrial thickness by two observers in 30 women undergoing assisted reproduction treatment. Endometrial volume was measured with Virtual Organ Computer-aided AnaLysis (VOCAL (TM)) in the longitudinal (A) and coronal (C) planes using an unmodified multiplanar view (UMV) and a standardized multiplanar view (SMV). Measurement reliability was evaluated by intraclass correlation coefficient (ICC) and agreement was examined using Bland-Altman plots with limits of agreement (LoA). The ease of outlining the endometrial-myometrial interface was compared between the A-and C-planes using subjective assessment. Results Endometrial volume measurements using the SMV and A-plane were more reliable (intra-and interobserver ICCs, 0.979 and 0.975, respectively) than were measurements of endometrial thickness using 2D-US (intra-and interobserver ICCs, 0.742 and 0.702, respectively) or 3D-US (intra-and interobserver ICCs, 0.890 and 0.784, respectively). The LoAs were narrower for SMV than for UMV. Reliability and agreement were not much different between the A- and C-planes. However the observers agreed that delineating the endometrial-myometrial interface using the A-plane was easier (first and second observer, 50.0 and 46.7%, respectively) or `comparable` (50 and 53.3%, respectively), but never more difficult than using the C-plane. Conclusions Endometrial volume measurements are more reliable than endometrial thickness measurements and are best performed using SMV and the A-plane. Copyright (C) 2011 ISUOG. Published by John Wiley & Sons, Ltd.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective. Endothelial impairment evaluation by sonographic measurement of flow-mediated dilatation (FMD) has become broadly used. However, this method has 2 main caveats: the dilatation depends on the baseline arterial diameter, and a high precision level is required. Vasodilatation leads to an amplified fall in impedance. We hypothesized that assessment of the pulsatility index change (PI-C) 1 minute after 5-minute forearm compression might evaluate that fall in impedance. The aim of this study was to compare the PI-C with FMD. Methods. Flow-mediated dilatation and the PI-C were assessed in 51 healthy women aged between 35.1 and 67.1 years. We correlated both FMD and the PI-C with age, body mass index, waist circumference, cholesterol level, high-density lipoprotein level, glucose level, systolic and diastolic blood pressure, pulse pressure, brachial artery diameter, simplified Framingham score, intima-media thickness, and carotid stiffness index. Intraclass correlation coefficients between 2 FMD and PI-C measurements were also examined. Results. Only FMD correlated with baseline brachial diameter (r=-0.53). The PI-C had a high correlation with age, body mass index, waist circumference, cholesterol level, systolic blood pressure, pulse pressure, simplified Framingham score, and intima-media thickness. The correlation between FMD and the PI-C was high (r=-0.66). The PI-C had a higher intraclass correlation coefficient (0.991) than FMD (0.836) but not brachial artery diameter (0.989). Conclusions. The PI-C had a large correlation with various markers of cardiovascular risk. Additionally, PI-C measurement does not require offline analysis, extra software, or electrocardiography We think that the PI-C could be considered a marker of endothelial function. However, more studies are required before further conclusions.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives The methods currently available for the measurement of energy expenditure in patients, such as indirect calorimetry and double-labelled water, are expensive and are limited in Brazil to research projects. Thus, equations for the prediction of resting metabolic rate appear to be a viable alternative for clinical practice. However, there are no specific equations for the Brazilian population and few studies have been conducted on Brazilian women in the climacteric period using existing and commonly applied equations. On this basis, the objective of the present study was to investigate the concordance between the predictive equations most frequently used and indirect calorimetry for the measurement of resting metabolic rate. Methods We calculated the St. Laurent concordance correlation coefficient between the equations and resting metabolic rate calculated by indirect calorimetry in 46 climacteric women. Results The equation showing the best concordance was that of the FAO/WHO/UNU formula (0.63), which proved to be better than the Harris & Benedict equation (0.55) for the sample studied. Conclusions On the basis of the results of the present study, we conclude that the FAO/WHO/UNU formula can be used to predict better the resting metabolic rate of climacteric women. Further studies using more homogeneous and larger samples are needed to permit the use of the FAO/WHO/UNU formula for this population group with greater accuracy.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives. To compare pelvic floor muscle (PFM) strength between women undergoing vaginal delivery, cesarean section, and nulliparae, investigating the factors associated with PFM strength, and observing the correlation between vaginal digital palpation and use of a perineometer. Methods. A cross-sectional study was conducted, including 31 women following vaginal delivery, 30 women following cesarean section, and 30 nulliparous women. PFM strength was measured by vaginal digital palpation and use of a perineometer. Multiple linear regression analysis with adjustment for covariables was used to compare the mean PFM strength and identify its associated factors. Results. The mean PFM strength of women undergoing vaginal delivery and cesarean section was 25.6 +/- 14.5 cmH(2)O and 39.6 +/- 22.0 cmH(2)O (p < 0.01, adjusted for covariables), respectively. A correlation was observed between measurements of PFM strength obtained by vaginal digital palpation and use of a perineometer (tau = 0.82; p < 0.01). The non-white race/ethnicity was negatively associated with PFM strength (coefficient: -10.2424; p = 0.02). Conclusions. A lower PFM strength was observed in women with a history of vaginal delivery compared to those undergoing cesarean section. Non-white race/ethnicity negatively affected PFM strength. Our data suggest that vaginal digital palpation may be used in clinical practice because of its expressive correlation with use of a perineometer.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: This study was aimed at assessing the psychometric qualities of the abbreviated versions of the Alcohol Use Disorders Identification Test (AUDIT-3, AUDIT-4, AUDIT-C, AUDIT-PC, AUDIT-QF, FAST, and Five-Shot) and at comparing them to the 10-item AUDIT and the CAGE in 2 samples of Brazilian adults. Methods: The validity and internal consistency of the scales were assessed in a sample of 530 subjects attended at an emergency department and at a Psychosocial Care Center for Alcohol and Drugs. The Structured Clinical Interview for DSM-IV was used as the diagnostic comparative measure for the predictive validity assessment. The concurrent validity between the scales was analyzed by means of Pearson`s correlation coefficient. Results: The assessment of the predictive validity of the abbreviated versions showed high sensitivity (of 0.78 to 0.96) and specificity (of 0.74 to 0.94) indices, with areas under the curve as elevated as those of the AUDIT (0.89 and 0.92 to screen for abuse and 0.93 and 0.95 in the screening of dependence). The CAGE presented lower indices: 0.81 for abuse and 0.87 for dependence. The analysis of the internal consistency of the AUDIT and its versions exhibited Cronbach`s alpha coefficients between 0.83 and 0.94, while the coefficient for the CAGE was 0.78. Significant correlations were found between the 10-item AUDIT and its versions, ranging from 0.91 to 0.99. Again, the results for the CAGE were satisfactory (0.77), although inferior to the other instruments. Conclusions: The results obtained in this study confirm the validity of the abbreviated versions of the AUDIT for the screening of alcohol use disorders and show that their psychometric properties are as satisfactory as those of the 10-item AUDIT and the CAGE.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to create an adaptation of the Revised Knox Preschool Play Scale (RKPPS) for the Brazilian population, as well as to apply the instrument with statistical analysis to verify the preliminary intra-rater and inter-rater reliability and repeatability of the instrument. The instructions presented by Beaton et al. regarding adaptation of instruments were followed to perform a cross-cultural adaptation of the RKPPS. A preliminary test of the Portuguese version was performed on 18 children with no motor, cognitive or sensory impairment. The video recordings of this administration were analysed on two separate occasions by two examiners within a 5-month interval, using the scores suggested by Pfeifer. The Spearman`s test was used in the statistical analysis of the obtained data. The author of the RKPPS agreed with the small necessary cultural adaptations. The Spearman test revealed a high correlation coefficient and good significance levels for both intra- and inter-raters values. This study demonstrated the reliability and repeatability of the Brazilian version of the RKPPS. This is a preliminary study and further studies are needed in order to validate the scale to be administered in the Brazilian population. Copyright (C) 2010 John Wiley & Sons, Ltd.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The mechanical alterations related to the excessive use of accessory respiratory muscles and the mouth breathing observed in children with asthma may lead to the development of alterations in head posture, shoulders, thoracic region and, consequently, in alterations of body posture. The purpose of this study was to assess body posture changes of children with asthma compared to a non-asthmatic control group matched for gender, age, weight, and height. Thirty children with asthma and 30 non-asthmatic children aged 7 to 12 years were enrolled in this study. Digital photographic records were obtained for analysis of the body posture of the children by computed photogrammetry. The intraclass correlation coefficient and Student`s t test (p < 0.05) were used for statistical analysis. There were no significant differences between groups for the angles analyzed, except for the knee flexor angle. These results demonstrate that children with asthma did not present postural alterations compared to non-asthmatic controls since the only angle for which there was a significant difference between groups showed weak reproducibility. The findings of this study do not support the notion that children with asthma present alterations in body posture.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study examined the psychometric properties of the Brazilian versions of the Fagerstrom Test for Nicotine Dependence (FTND) and the Heaviness of Smoking Index (HSI). The test-retest reliability of the FTND was assessed in a sample of 61 smoking university students, with a 15-day interval between assessments. The interrater reliability was examined in 30 smoking patients of a psychosocial care center for alcohol and drug users (PCC-AD). The reliability coefficient was estimated by the kappa and intraclass correlation coefficients. The predictive validity, internal consistency, and factor structure of the FTND and the HSI were evaluated by factor analysis in 271 smokers treated at an emergency unit and at the PCC-AD. The gold standard was the nicotine dependence criteria of DSM-IV, as assessed by the Structured Clinical Interview for DSM-IV. The FTND showed high reliability, with correlation coefficients of .92 for test-retest reliability and .99 for interrater reliability. Both the FTND and the HSI presented high levels of sensitivity and specificity. The internal consistency evaluation yielded a Cronbach`s alpha coefficient of .83 for the FTND and of .56 for the HSI. An exploratory factor analysis found 2 factors in the FTND, which were validated by a confirmatory factor analysis. The results obtained in this study confirm the validity and reliability of the Brazilian versions of the FTND and the HSI.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: We aimed to validate three widely used scales in stroke research in a multiethnic Brazilian population. Methods: The National Institutes of Health Stroke Scale (NIHSS), modified Rankin Scale (mRS) and Barthel Index (BI) were translated, culturally adapted and applied by two independent investigators. The mRS was applied with or without a previously validated structured interview. Interobserver agreement (kappa statistics) and intraclass correlation coefficients were calculated. Results: 84 patients underwent mRS (56 with and 28 without a structured interview), 57 BI and 62 NIHSS scoring. Intraclass correlation coefficient was 0.902 for NIHSS and 0.967 for BI. For BI, interobserver agreement was good (kappa = 0.70). For mRS, the structured interview improved interobserver agreement (kappa = 0.34 without a structured interview; 0.75 with a structured interview). Conclusion: The NIHSS, BI and mRS show good validity when translated and culturally adapted. Using a structured interview for the mRS improves interobserver concordance rates. Copyright (C) 2008 S. Karger AG, Basel

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: Contact lens electrodes (CLEs) are frequently used to register electroretinograms (ERGs) in small animals such as mice or rats. CLEs are expensive to buy or difficult to be produced individually. In addition, CLE`s have been noticed to elicit inconstant results and they carry potential to injure the cornea. Therefore, a new electrode holder was constructed based on the clinically used DTL-electrode and compared to CLEs. Material and methods: ERGs were recorded with both electrode types in nine healthy Brown-Norway rats under scotopic conditions. For low intensity responses a Naka-Rushton function was fitted and the parameters V(max), k and n were analyzed. The a-wave, b-wave and oscillatory potentials were analyzed for brighter flash intensities (1-60 scot cd s/m(2)). Repeatability was assessed for both electrode types in consecutive measurements. Results: The new electrode holder was faster in setting up than the CLE and showed lower standard deviations. No corneal alterations were observed. Slightly higher amplitudes were recorded in most of the measurements with the new electrode holder (except amplitudes induced by 60 cd s/m(2)). A Bland-Altman test showed good agreement between the DTL holder and the CLE (mean difference 35.2 mu V (Holder-CLE)). Pearson`s correlation coefficient for test-retest-reliability was r = 0.783. Conclusions: The DTL holder was superior in handling and caused far less corneal problems than the CLE and produced comparable or better electrophysiological results. The minimal production costs and the possibility of adapting the DTL holder to bigger eyes, such as for dogs or rabbits, offers with broader application prospects. (C) 2010 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: Clinical evaluation of the stomatognathic system is indispensable for the diagnosis of orofacial myofunctional disorders. In order to obtain a more precise diagnosis, the protocol of orofacial myofunctional evaluation with scores (OMES protocol) (Int. J. Pediatr. Otorhinolaryngol. 72 (2008) 367-375) was expanded in terms of number of items and scale amplitude. The proposal of this study is to describe the expanded OMES protocol (OMES-E) for the evaluation of children. Validity of the protocol, reliability of the examiners and agreement between them were analyzed, as also were the sensitivity, specificity and predictive values of the instrument. Methods: The sample consisted of videorecorded images of 50 children, 25 boys (mean age = 8.4 years, SD = 1.8) and 25 girls (mean age = 8.2 years, SD = 1.7) selected at random from 200 samples. Three speech therapists prepared for orofacial myofunctional evaluation participated as examiners (E). The OMES and OMES-E protocols were used for evaluation on different days. E1 evaluated all images, E2 analyzed children with recordings from 1 to 25 and E3 analyzed children with recordings from 26 to 50. The validity of OMES-E was analyzed by comparing the instrument to the OMES protocol using the Pearson correlation test complemented with the split-half reliability test (p < 0.05). The linear weighted Kappa coefficient of agreement (Kw`), the sensitivity, specificity and predictive values and the prevalence of OMD were calculated. Results: There was a statistically significant correlation between the OMES and OMES-E protocols (0.79 > r < 0.94, p < 0.01) and a significant test-retest correlation with the OMES-E (0.75 > r < 0.86, p < 0.01), with a reliability range of 0.86-0.93. The correlation and reliability coefficients between examiners were: E1 x E2 (r = 0.74, 0.84), E1 x E3 (r = 0.70, 0.83) (p < 0.01). Kw` coefficients with moderate and good strength predominated. The OMES-E protocol presented mean sensitivity = 0.91, specificity = 0.77, positive predictive value = 0.87 and negative predictive value = 0.85. The mean prevalence of OMD was 0.58. Conclusion: The OMES-E protocol is valid and reliable for orofacial myofunctional evaluation. (C) 2010 Elsevier Ireland Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

To test a mathematical model for measuring blinking kinematics. Spontaneous and reflex blinks of 23 healthy subjects were recorded with two different temporal resolutions. A magnetic search coil was used to record 77 blinks sampled at 200 Hz and 2 kHz in 13 subjects. A video system with low temporal resolution (30 Hz) was employed to register 60 blinks of 10 other subjects. The experimental data points were fitted with a model that assumes that the upper eyelid movement can be divided into two parts: an impulsive accelerated motion followed by a damped harmonic oscillation. All spontaneous and reflex blinks, including those recorded with low resolution, were well fitted by the model with a median coefficient of determination of 0.990. No significant difference was observed when the parameters of the blinks were estimated with the under-damped or critically damped solutions of the harmonic oscillator. On the other hand, the over-damped solution was not applicable to fit any movement. There was good agreement between the model and numerical estimation of the amplitude but not of maximum velocity. Spontaneous and reflex blinks can be mathematically described as consisting of two different phases. The down-phase is mainly an accelerated movement followed by a short time that represents the initial part of the damped harmonic oscillation. The latter is entirely responsible for the up-phase of the movement. Depending on the instantaneous characteristics of each movement, the under-damped or critically damped oscillation is better suited to describe the second phase of the blink. (C) 2010 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

P>The determination of normal parameters is an important procedure in the evaluation of the stomatognathic system. We used the surface electromyography standardization protocol described by Ferrario et al. (J Oral Rehabil. 2000;27:33-40, 2006;33:341) to determine reference values of the electromyographic standardized indices for the assessment of muscular symmetry (left and right side, percentage overlapping coefficient, POC), potential lateral displacing components (unbalanced contractile activities of contralateral masseter and temporalis muscles, TC), relative activity (most prevalent pair of masticatory muscles, ATTIV) and total activity (integrated areas of the electromyographic potentials over time, IMPACT) in healthy Brazilian young adults, and the relevant data reproducibility. Electromyography of the right and left masseter and temporalis muscles was performed during maximum teeth clenching in 20 healthy subjects (10 women and 10 men, mean age 23 years, s.d. 3), free from periodontal problems, temporomandibular disorders, oro-facial myofunctional disorder, and with full permanent dentition (28 teeth at least). Data reproducibility was computed for 75% of the sample. The values obtained were POC Temporal (88 center dot 11 +/- 1 center dot 45%), POC masseter (87 center dot 11 +/- 1 center dot 60%), TC (8 center dot 79 +/- 1 center dot 20%), ATTIV (-0 center dot 33 +/- 9 center dot 65%) and IMPACT (110 center dot 40 +/- 23 center dot 69 mu V/mu V center dot s %). There were no statistical differences between test and retest values (P > 0 center dot 05). The Technical Errors of Measurement (TEM) for 50% of subjects assessed during the same session were 1 center dot 5, 1 center dot 39, 1 center dot 06, 3 center dot 83 and 10 center dot 04. For 25% of the subjects assessed after a 6-month interval, the TEM were 0 center dot 80, 1 center dot 03, 0 center dot 73, 12 center dot 70 and 19 center dot 10. For all indices, there was good reproducibility. These electromyographic indices could be used in the assessment of patients with stomatognathic dysfunction.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: In the literature there is no validated instrument for the clinical evaluation of the orofacial myofunctional condition of children that will permit the examiner to express numerically his perception of the characteristics and behaviors observed. The proposal of this study is to describe a protocol for the evaluation of children aged 6-12 years in order to establish relations between the orofacial. myofunctional conditions and numerical scales. The protocol validity, reliability of the examiners and agreement between them was analyzed. Methods: Eighty children aged 6-12 years participated in the study. All were evaluated and 30 were selected at random for the analyses (age range: 72-149 months, mean = 103.3, S.D. = 23.57). Individuals with and without orofacial myofunctional. disorders were included. The examiners were two speech therapists property calibrated in orofacial myofunctional evaluation. Two protocols were constructed. One, based on traditional models, was called traditional orofacial. myofunctional. evaluation (TOME), and the other, with the addition of numerical scales, was called orofacial myofunctional. evaluation with scores (OMES). The clinical conditions included were: appearance, posture and mobility of lips, tongue, cheeks and jaws, respiration, mastication and deglutition. Statistical analysis was performed using the split-half reliability method. Means, standard deviations and the Spearman correlation coefficient were also calculated. Results: There was a statistically significant correlation between the evaluations of 30 children assessed with the TOME and OMES protocols (r = 0.85, p < 0.01). The reliability between protocols was 0.92. The test-retest reliability of the OMES instrument was 0.99 and the correlation was 0.98. Reliability between examiners 1 and 2 using the OMES protocol was 0.99, and the correlation was 0.98 (P < 0.01). Conclusion: The OMES protocot proved to be a valid and reliable instrument for orofacial myofunctional evaluation, permitting the grading of orofacial myofunctional conditions within the limits of the selected items. (c) 2007 Elsevier Ireland Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aim: To demonstrate that the evaluation of erythrocyte dysmorphism by light microscopy with lowering of the condenser lens (LMLC) is useful to identify patients with a haematuria of glomerular or non-glomerular origin. Methods: A comparative double-blind study between phase contrast microscopy (PCM) and LMLC is reported to evaluate the efficacy of these techniques. Urine samples of 39 patients followed up for 9 months were analyzed, and classified as glomerular and non-glomerular haematuria. The different microscopic techniques were compared using receiver-operator curve (ROC) analysis and area under curve (AUC). Reproducibility was assessed by coefficient of variation (CV). Results: Specific cut-offs were set for each method according to their best rate of specificity and sensitivity as follows: 30% for phase contrast microscopy and 40% for standard LMLC, reaching in the first method the rate of 95% and 100% of sensitivity and specificity, respectively, and in the second method the rate of 90% and 100% of sensitivity and specificity, respectively. In ROC analysis, AUC for PCM was 0.99 and AUC for LMLC was 0.96. The CV was very similar in glomerular haematuria group for PCM (35%) and LMLC (35.3%). Conclusion: LMLC proved to be effective in contributing to the direction of investigation of haematuria, toward the nephrological or urological side. This method can substitute PCM when this equipment is not available.