915 resultados para Continuous flow injection system, FIAlab 2600
Resumo:
A new principle of sampling aerosol particles by means of steam injection with the consequent collection of grown droplets has been established. An air stream free of water-soluble gases is rapidly mixed with steam. The resulting supersaturation causes aerosol particles to grow into droplets. The droplets containing dissolved aerosol species are then collected by two cyclones in series. The solution collected in the cyclones is constantly pumped out and can be on- or off-line analysed by means of ion chromatography or flow injection analysis. On the basis of the new sampling principle a prototype of an aerosol sampler was designed which is capable of sampling particles quantitatively down to several nanometres in diameter. The mass sampling efficiency of the instrument was found to be 99\%. The detection limit of the sampler for ammonium, sulphate, nitrate and chloride ions is below 0.7 mu g m(-3). By reduction of an already identified source of contamination, much lower detection limits can be achieved. During measurements the sampler proved to be stable, working without any assistance for extended periods of time. Comparison of the sampler with filter packs during measurements of ambient air aerosols showed that the sampler gives good results.
Resumo:
The long-term impact of dietary carbohydrate type, in particular sucrose, on insulin resistance and the development of diabetes and atherosclerosis is not established. Current guidelines for the healthy population advise restriction of sucrose intake. We investigated the effect of high- versus low-sucrose diet (25 vs. 10%, respectively, of total energy intake) in 13 healthy subjects aged 33 +/- 3 years (mean +/- SE), BMI 26.6 +/- 0.9 kg/m(2), in a randomized crossover design with sequential 6-week dietary interventions separated by a 4-week washout. Weight maintenance, eucaloric diets with identical macronutrient profiles and fiber content were designed. All food was weighed and distributed. Insulin action was assessed using a two-step euglycemic clamp; glycemic profiles were assessed by the continuous glucose monitoring system and vascular compliance by pulse-wave analysis. There was no change in weight across the study. Peripheral glucose uptake and suppression of endogenous glucose production were similar after each diet. Glycemic profiles and measures of vascular compliance did not change. A rise in total and LDL cholesterol was observed. In this study, a high-sucrose intake as part of an eucaloric, weight-maintaining diet had no detrimental effect on insulin sensitivity, glycemic profiles, or measures of vascular compliance in healthy nondiabetic subjects.
Resumo:
Chiral enamides5f-i were found to react with pyrylium ylides to give cycloadducts 6d-i in good yields with an excellent level of stereoselectivity. The chiral auxiliary was successfully removed on hydrogenolysis of compound 6f in continuous flow (H-Cube) resulting in the first asymmetric synthesis of complex amine 8.
Resumo:
RATIONALE Stable isotope values (d13C and d15N) of darted skin and blubber biopsies can shed light on habitat use and diet of cetaceans, which are otherwise difficult to study. Non-dietary factors affect isotopic variability, chiefly the depletion of C due to the presence of C-rich lipids. The efficacy of post hoc lipid-correction models (normalization) must be tested. METHODS For tissues with high natural lipid content (e.g., whale skin and blubber), chemical lipid extraction or normalization is necessary. C:N ratios, d13C values and d15N values were determined for duplicate control and lipid-extracted skin and blubber of fin (Balaenoptera physalus), humpback (Megaptera novaeangliae) and minke whales (B. acutorostrata) by continuous-flow elemental analysis isotope ratio mass spectrometry (CF-EA-IRMS). Six different normalization models were tested to correct d13C values for the presence of lipids. RESULTS Following lipid extraction, significant increases in d13C values were observed for both tissues in the three species. Significant increases were also found for d15N values in minke whale skin and fin whale blubber. In fin whale skin, the d15N values decreased, with no change observed in humpback whale skin. Non-linear models generally out-performed linear models and the suitability of models varied by species and tissue, indicating the need for high model specificity, even among these closely related taxa. CONCLUSIONS Given the poor predictive power of the models to estimate lipid-free d13C values, and the unpredictable changes in d N values due to lipid-extraction, we recommend against arithmetical normalization in accounting for lipid effects on d13C values for balaenopterid skin or blubber samples. Rather, we recommend that duplicate analysis of lipid-extracted (d13C values) and non-treated tissues (d15N values) be used. Copyright © 2012 John Wiley & Sons, Ltd.
Resumo:
The combination of ionic liquids (ILs) and supercritical CO2 (scCO2) allows efficient catalytic processes to be developed. Catalyst separation is generally a major challenge when enzymes or homogeneous organometallic catalysts are utilised for reactions, and IL–scCO2 systems address these separation problems, facilitating the recycling or continual use of the catalyst. Typically these systems involve a catalyst being dissolved in an IL and this is where it remains during the process, with scCO2 extracting the products from the IL (catalyst) phase. ILs and many catalysts are not soluble in scCO2 and this facilitates the clean separation of products from the catalyst and IL. When the pressure is reduced in a collection chamber, the scCO2 returns to CO2 gas and products can be obtained without contamination of catalyst or solvents. It is possible to operate IL–scCO2 systems in a continuous flow manner and this further improves the efficiency and industrial potential of these systems. This chapter will introduce the fundamental properties of these multiphase catalytic systems. It will also highlight key examples of catalytic processes from the academic literature which illustrate the benefits of utilising this combination of solvents for catalysis
Resumo:
The study assessed the effect of heating vermiculites on extractability of phosphorus, iron, zinc and manganese with respect to their potential agricultural use. Of these elements, phosphorus was from apatite and monazite that occur as accessory minerals in vermiculites. Vermiculites were heated at 15-800 degrees C and digested by acetic acid for extracting phosphorus and diethylene triamine pentaacetic acid (DTPA) for extracting zinc, iron and manganese. Phosphorus in the extract was analysed by a flow injection method while zinc, iron and manganese were measured by atomic absorption spectrometry. The results showed that heating vermiculites to 400 C enhanced extractability of phosphorus from apatite and monazite to a level of 335 mg kg(-1). Further heating to 800 degrees C reduced extractable phosphorus to less than 75 mg kg(-1). Maximum extractable zinc, iron and manganese found were 2.7, 19.1 and 22.9 mg kg(-1), respectively, values that are beneficial and tolerable by most plants. Thus, it was concluded that heating vermiculites to
Resumo:
Nontypable Haemophilus influenzae (NTHi) is a major cause of opportunistic respiratory tract disease, and initiates infection by colonizing the nasopharynx. Bacterial surface proteins play determining roles in the NTHi-airways interplay, but their specific and relative contribution to colonization and infection of the respiratory tract has not been addressed comprehensively. In this study, we focused on the ompP5 and hap genes, present in all H. influenzae genome sequenced isolates, and encoding the P5 and Hap surface proteins, respectively. We employed isogenic single and double mutants of the ompP5 and hap genes generated in the pathogenic strain NTHi375 to evaluate P5 and Hap contribution to biofilm growth under continuous flow, to NTHi adhesion, and invasion/phagocytosis on nasal, pharyngeal, bronchial, alveolar cultured epithelial cells and alveolar macrophages, and to NTHi murine pulmonary infection. We show that P5 is not required for bacterial biofilm growth, but it is involved in NTHi interplay with respiratory cells and in mouse lung infection. Mechanistically, P5NTHi375 is not a ligand for CEACAM1 or α5 integrin receptors. Hap involvement in NTHi375-host interaction was shown to be limited, despite promoting bacterial cell adhesion when expressed in H. influenzae RdKW20. We also show that Hap does not contribute to bacterial biofilm growth, and that its absence partially restores the deficiency in lung infection observed for the ΔompP5 mutant. Altogether, this work frames the relative importance of the P5 and Hap surface proteins in NTHi virulence.
Resumo:
Nontypable Haemophilus influenzae (NTHi) has emerged as an important opportunistic pathogen causing infection in adults suffering obstructive lung diseases. Existing evidence associates chronic infection by NTHi to the progression of the chronic respiratory disease, but specific features of NTHi associated with persistence have not been comprehensively addressed. To provide clues about adaptive strategies adopted by NTHi during persistent infection, we compared sequential persistent isolates with newly acquired isolates in sputa from six patients with chronic obstructive lung disease. Pulse field gel electrophoresis (PFGE) identified three patients with consecutive persistent strains and three with new strains. Phenotypic characterisation included infection of respiratory epithelial cells, bacterial self-aggregation, biofilm formation and resistance to antimicrobial peptides (AMP). Persistent isolates differed from new strains in showing low epithelial adhesion and inability to form biofilms when grown under continuous-flow culture conditions in microfermenters. Self-aggregation clustered the strains by patient, not by persistence. Increasing resistance to AMPs was observed for each series of persistent isolates; this was not associated with lipooligosaccharide decoration with phosphorylcholine or with lipid A acylation. Variation was further analyzed for the series of three persistent isolates recovered from patient 1. These isolates displayed comparable growth rate, natural transformation frequency and murine pulmonary infection. Genome sequencing of these three isolates revealed sequential acquisition of single-nucleotide variants in the AMP permease sapC, the heme acquisition systems hgpB, hgpC, hup and hxuC, the 3-deoxy-D-manno-octulosonic acid kinase kdkA, the long-chain fatty acid transporter ompP1, and the phosphoribosylamine glycine ligase purD. Collectively, we frame a range of pathogenic traits and a repertoire of genetic variants in the context of persistent infection by NTHi.
Resumo:
Electroanalytical methods based on square-wave adsorptive-stripping voltammetry (SWAdSV) and flow-injection analysis with SWAdSV detection (FIA-SWAdSV) were developed for the determination of paroxetine (PRX). The methods were based on the reduction of PRX at a mercury drop electrode at −1.55V versus Ag/AgCl, in a borate buffer of pH 8.8, and the possibility of accumulating the compound at the electrode surface. Because the presence of dissolved oxygen did not interfere significantly with the analysis, it was also possible to determine PRX using FIASWAdSV. This method enables analysis of up to 120 samples per hour at reduced costs. Both methods developed were validated and successfully applied to the quantification of PRX in pharmaceutical products.
Resumo:
The electrochemical behaviour of the herbicide Asulam was studied by cyclic and square wave voltammetry. Asulam may be irreversibly oxidised at a glassy carbon electrode. Maximum currents were obtained at pH=1.9 in aqueous electrolyte solution. Based on the electrochemical behaviour of Asulam, two analytical methodologies were developed for its determination in water samples, using square wave voltammetry (SWV) and flow injection analysis (FIA) coupled with an amperometric detector. Limits of detection of 7.1x10-6 mol L-1 and 1.2x10-8 mol L-1 for SWV and FIA respectively, were achieved. Repeatability was calculated by assessing the relative standard deviation (%) for 10 consecutive determinations of one sample. The found values were 2.1% for SWV and 5.0% for FIA. Validation of the results provided by SWV and FIA methodologies was performed by comparison with results from an HPLC-DAD technique. Good relative deviations were found (<5%). Recovery trials were performed to assess the accuracy of the results and the obtained values were between 84% and 107% for both methods.
Resumo:
Aflowinjection squarewave cathodic stripping voltammetric method has been developed for the determination of sertraline in a pharmaceutical preparation. The method shows linearity between peak current intensity and sertraline concentration for the interval between 0.20×10−6 and 1.20×10−6 mol L−1. Limits of detection and quantification were found to be 1.5×10−7 and 5.0×10−7 mol L−1, respectively. Up to 70 samples per hour can be analysed with a good precision (R.S.D. = 2.5%). The proposed method was successfully applied to the determination of sertraline in a commercial product. In the voltammetric determination of sertraline in flow, a high sample rate is obtained at reduced costs, opening the possibility to compete with the chromatographic methods generally used for this analysis.
Resumo:
Dissertação para obtenção do grau de Mestre em Engenharia Electrotécnica Ramo de Energia
Resumo:
We present a new method for lysis of single cells in continuous flow, where cells are sequentially trapped, lysed and released in an automatic process. Using optimized frequencies, dielectrophoretic trapping allows exposing cells in a reproducible way to high electrical fields for long durations, thereby giving good control on the lysis parameters. In situ evaluation of cytosol extraction on single cells has been studied for Chinese hamster ovary (CHO) cells through out-diffusion of fluorescent molecules for different voltage amplitudes. A diffusion model is proposed to correlate this out-diffusion to the total area of the created pores, which is dependent on the potential drop across the cell membrane and enables evaluation of the total pore area in the membrane. The dielectrophoretic trapping is no longer effective after lysis because of the reduced conductivity inside the cells, leading to cell release. The trapping time is linked to the time required for cytosol extraction and can thus provide additional validation of the effective cytosol extraction for non-fluorescent cells. Furthermore, the application of one single voltage for both trapping and lysis provides a fully automatic process including cell trapping, lysis, and release, allowing operating the device in continuous flow without human intervention.
Resumo:
Patients with chronic heart failure who are not eligible for heart transplant and whose life expectancy depends mainly on the heart disease may benefit from mechanical circulatory support. Mechanical circulatory support restores adequate cardiac output and organ perfusion and eventually improves patients' clinical condition, quality of life and life expectancy. This treatment is called destination therapy (DT) and we estimate that in Switzerland more than 120 patients per year could benefit from it. In the last 10 years, design of the devices, implantation techniques and prognoses have changed dramatically. The key to successful therapy with a left ventricular assist device is appropriate patient selection, although we are still working on the definition of reliable inclusion and exclusion criteria and optimal timing for surgical implantation. Devices providing best long-term results are continuous flow, rotary or axial blood pumps implanted using minimally invasive techniques on a beating heart. These new devices (Thoratec HeartMate II and HeartWare HVAD) have only a single moving part, and have improved durability with virtually 10 years freedom from mechanical failure. In selected patients, the overall actuarial survival of DT patients is 75% at 1 year and 62% at 2 years, with a clear improvement in quality of life compared with medical management only. Complications include bleeding and infections; their overall incidence is significantly lower than with previous devices and their management is well defined. DT is evolving into an effective and reasonably cost-effective treatment option for a growing population of patients not eligible for heart transplant, showing encouraging survival rates at 2 years and providing clear improvement in quality of life. The future is bright for people suffering from chronic heart failure.
Resumo:
Le diabète de type 1 (DT1) est une maladie complexe qui requiert une implication importante des patients pour contrôler leur glycémie et ainsi prévenir les complications et comorbidités. L’activité physique (AP) régulière et une attention constante pour les glucides ingérés sont des adjuvants essentiels au traitement insulinique. Nous avons démontré que le questionnaire BAPAD-1, spécifiquement développé pour des adultes atteints de DT1, est un outil valide (validité prédictive, fiabilité interne et reproductibilité) pour définir des barrières associées à l’AP. Bien que le niveau de barrières envers l’AP soit faible, la crainte de l’hypoglycémie est la barrière la plus importante chez cette population. L’adoption d’un mode de vie actif est associée à un profil corporel favorable. Les adultes, avec un DT1 et non diabétique, qui maintiennent un bon niveau d’AP, soit un ratio entre la dépense énergétique totale et celle au repos ≥ 1.7, ont une masse grasse, un indice de masse corporelle et un tour de taille significativement inférieurs à ceux d’adultes moins actifs. Le niveau d’AP peut être estimé au moyen d’un moniteur d’AP comme le SenseWear Armband™. Afin de compléter les études de validation de cet outil, nous avons évalué et démontré la reproductibilité des mesures. Toutefois, la dépense énergétique est sous-estimée durant les 10 premières minutes d’une AP d’intensité modérée sur ergocycle. L’utilisation de cet appareil est donc justifiée pour une évaluation de la dépense énergétique sur de longues périodes. Le calcul des glucides est une méthode largement utilisée pour évaluer la quantité d’insuline à injecter lors des repas. Nous avons évalué dans un contexte de vie courante, sans révision de la technique, la précision des patients pour ce calcul. L’erreur moyenne est de 15,4 ± 7,8 g par repas, soit 20,9 ± 9,7 % du contenu glucidique. L’erreur moyenne est positivement associée à de plus grandes fluctuations glycémiques mesurées via un lecteur de glucose en continu. Une révision régulière du calcul des glucides est probablement nécessaire pour permettre un meilleur contrôle glycémique. Nous avons développé et testé lors d’un essai clinique randomisé contrôlé un programme de promotion de l’AP (PEP-1). Ce programme de 12 semaines inclut une séance hebdomadaire en groupe ayant pour but d’initier l’AP, d’établir des objectifs et d’outiller les adultes atteints de DT1 quant à la gestion de la glycémie à l’AP. Bien que n’ayant pas permis d’augmenter la dépense énergétique, le programme a permis un maintien du niveau d’AP et une amélioration de la condition cardio-respiratoire et de la pression artérielle. À la fin du programme, une plus grande proportion de patients connaissait la pharmacocinétique de l’insuline et une plus grande variété de méthodes pour contrer l’hypoglycémie associée à l’AP était utilisée. En conclusion, le diabète de type 1 engendre des défis quotidiens particuliers. D’une part, le calcul des glucides est une tâche complexe et son imprécision est associée aux fluctuations glycémiques quotidiennes. D’autre part, l’adoption d’un mode de vie actif, qui est associée à un meilleur profil de composition corporelle, est limitée par la crainte des hypoglycémies. Le programme PEP-1 offre un support pour intégrer l’AP dans les habitudes de vie des adultes avec un DT1 et ainsi améliorer certains facteurs de risque cardio-vasculaire.