985 resultados para Composite Measurement Scales
Resumo:
Enzymatic polymerization of aniline was first performed in lignosulfonate (LGS) template system. High-redox-potential catalyst laccase, isolated from Aspergillus, was used as a biocatalyst in the synthesis of conducting polyaniline/lignosulfonate (PANI-ES-LGS) complex using atmospheric oxygen as the oxidizing agent. The linear templates (LGS), also serving as the dopants, could facilitate the directional alignment of the monomer and improve the solubility of the conducting polymer. The process of the polymerization was monitored using UV-Vis spectroscopy, by which the conditions for laccase-catalyzed synthesis of PANI-ES-LGS complex were also optimized. The structure characterizations and solubility of the complex were carried out using corresponding characterization techniques respectively. The PANI-ES-LGS suspensions obtained was used as coating for cotton with a conventional padder to explore the applications of the complex. The variable optoelectronic properties of the coated cotton were confirmed by cyclic voltammetry and color strength test. The molecular weight changes of LGS treated by laccase were also studied to discuss the mechanism of laccase catalyzed aniline polymerization in LGS template system.
Resumo:
Tese de Doutoramento em Engenharia Civil
Resumo:
Introduction: Endometriosis Health Profile Questionnaire-30 is currently the most used questionnaire for quality of life measurement in women with endometriosis. The aim of this study is to evaluate the psychometric properties and to validate the Portuguese Endometriosis Health Profile Questionnaire-30 version. MATERIAL AND METHODS A sequential sample of 152 patients with endometriosis, followed in a Portugal reference center, were asked to complete a questionnaire on social and demographic features, the Portuguese version of the Endometriosis Health Profile Questionnaire-30 and of the Short Form Health Survey 36 Item â version 2. Appropriate statistical analysis was performed using descriptive statistics, factor analysis, internal consistency, item-total correlation and convergent validity. RESULTS Factorial analysis confirmed the validity of the five-dimension structure of the Endometriosis Health Profile Questionnaire-30 core questionnaire, which explained 83.2% of the total variance. All item-total correlations presented acceptable results and high internal consistency, with Cronbach's alpha ranging between 0.876 and 0.981 for the core questionnaire and between 0.863 and 0.951 for the modular questionnaire. Significant negative associations between similar scales of Endometriosis Health Profile Questionnaire-30 and Short Form Health Survey 36 Item â version 2 were demonstrated. Data completeness achieved was high for all dimensions. The emotional well-being scale in the core questionnaire and the infertility scale in the modular section had the highest median scores, and therefore the most negative impact on the quality of life of participating women. DISCUSSION The test-retest reliability and responsiveness of the questionnaire should be evaluated in future studies. CONCLUSION The present study demonstrates that the Portuguese version of the Endometriosis Health Profile Questionnaire-30 is a valid, reliable and acceptable tool for evaluating the health-related quality of life of Portuguese women with endometriosis.
Resumo:
OBJECTIVE - The aim of our study was to assess the profile of a wrist monitor, the Omron Model HEM-608, compared with the indirect method for blood pressure measurement. METHODS - Our study population consisted of 100 subjects, 29 being normotensive and 71 being hypertensive. Participants had their blood pressure checked 8 times with alternate techniques, 4 by the indirect method and 4 with the Omron wrist monitor. The validation criteria used to test this device were based on the internationally recognized protocols. RESULTS - Our data showed that the Omron HEM-608 reached a classification B for systolic and A for diastolic blood pressure, according to the one protocol. The mean differences between blood pressure values obtained with each of the methods were -2.3 +7.9mmHg for systolic and 0.97+5.5mmHg for diastolic blood pressure. Therefore, we considered this type of device approved according to the criteria selected. CONCLUSION - Our study leads us to conclude that this wrist monitor is not only easy to use, but also produces results very similar to those obtained by the standard indirect method.
Resumo:
This study is intended to analyze (1) differences in infant temperament at 3 and 12 months according to infants' psychophysiological profiles: "withdrawn" "extroverted", and "underaroused" and (2) changes in infant temperament from 3 to 12 months, namely according to the infant psychophysiological profile and the quality of mother-infant interaction. Ninety-four 8-week-old infants were assessed using the Neonatal Behavioral Assessment Scale (NBAS, Brazelton & Nugent, 1995) and the Alarm Distress Baby Scale (ADBB, Guedeney & Fermanian, 2001). Saliva samples were collected at 8-12 weeks old, both before and after a routine inoculation for cortisol reactivity measurement. Mother-infant interaction was evaluated at 12-16 weeks, using the Global Rating Scales (GRS, Murray, Fiori-Cowley, Hooper, & Cooper, 1996). Mothers' reports on infant temperament at 3 and 12 months were collected using the Infant Behavior Questionnaire (IBQ, Rothbart, 1981). Significant differences in mothers' perception of infant temperament were found at both 3 and 12 months in infants with distinct psychophysiological profiles. Stability was observed in most of the temperament's dimensions from 3 to 12 months old; still, there were changes in mothers' perception of infant temperament in terms of level of distress, cuddliness, sadness and approach. Infant psychophysiological profile and mother-infant interaction both influence with the pattern of those changes. The results corroborate that infant's characteristics early in life as well as contextual factors influence with mothers' perception of infant temperament and with changes across the 1st year of life.
Resumo:
As Escalas de Avaliação da Interação Mãe-Bebé constituem a versão portuguesa das Interaction Rating Scales, propostas por Field (1980), e têm por objetivo avaliar a interação mãe-bebé, aos 3 meses de idade do bebé. As Escalas de Avaliação da Interação Mãe-Bebé foram administradas a 51 díades mãe-bebé aos 3, 6 e 12 meses pós-parto. A versão portuguesa das escalas mostrou elevados índices de consistência interna – Alfa de Cronbach 0,85 (IRSff bebé), 0,91 (IRSff mãe), 0,87 (IRSal bebé), 0,82 (IRSal mãe), assim como elevada fidelidade e validade concorrente e preditiva. As Escalas de Avaliação da Interação Mãe-Bebé assume-se, assim, como um instrumento robusto na avaliação da interação mãe-bebé, na situação de interação face-a-face e na situação de interação alimentar, podendo ser utilizadas em diferentes amostras e contextos, clínicos e de investigação.
Resumo:
Tese de Doutoramento em Engenharia Têxtil
Resumo:
OBJECTIVE: To determine technical procedures and criteria used by Brazilian physicians for measuring blood pressure and diagnosing hypertension. METHODS: A questionnaire with 5 questions about practices and behaviors regarding blood pressure measurement and the diagnosis of hypertension was sent to 25,606 physicians in all Brazilian regions through a mailing list. The responses were compared with the recommendations of a specific consensus and descriptive analysis. RESULTS: Of the 3,621 (14.1%) responses obtained, 57% were from the southeastern region of Brazil. The following items were reported: use of an aneroid device by 67.8%; use of a mercury column device by 14.6%; 11.9% of the participants never calibrated the devices; 35.7% calibrated the devices at intervals < 1 year; 85.8% measured blood pressure in 100% of the medical visits; 86.9% measured blood pressure more than once and on more than one occasion. For hypertension diagnosis, 55.7% considered the patient's age, and only 1/3 relied on consensus statements. CONCLUSION: Despite the adequate frequency of both practices, it was far from that expected, and some contradictions between the diagnostic criterion for hypertension and the number of blood pressure measurements were found. The results suggest that, to include the great majority of the medical professionals, disclosure of consensus statements and techniques for blood pressure measurement should go beyond the boundaries of medical events and specialized journals.
Resumo:
OBJECTIVE: To assess the Dixtal DX2710 automated oscillometric device used for blood pressure measurement according to the protocols of the BHS and the AAMI. METHODS: Three blood pressure measurements were taken in 94 patients (53 females 15 to 80 years). The measurements were taken randomly by 2 observers trained to measure blood pressure with a mercury column device connected with an automated device. The device was classified according to the protocols of the BHS and AAMI. RESULT: The mean of blood pressure levels obtained by the observers was 148±38/93±25 mmHg and that obtained with the device was 148±37/89±26 mmHg. Considering the differences between the measurements obtained by the observer and those obtained with the automated device according to the criteria of the BHS, the following classification was adopted: "A" for systolic pressure (69% of the differences < 5; 90% < 10; and 97% < 15 mmHg); and "B" for diastolic pressure (63% of the differences < 5; 83% < 10; and 93% < 15 mmHg). The mean and standard deviation of the differences were 0±6.27 mmHg for systolic pressure and 3.82±6.21 mmHg for diastolic pressure. CONCLUSION: The Dixtal DX2710 device was approved according to the international recommendations.
Resumo:
OBJECTIVE: To assess blood pressure measurement by health professionals of a public hospital in São Paulo State. METHODS: Semi-structured interviews and direct observation were performed with a verification list according to the criteria reported by Perloff et al. One hundred and five health professionals took part in the study. After measuring blood pressure, the level of concordance between the way the procedure was performed and the recommended one was assessed. RESULTS: Nurses and nurse's aides abided by 40% of the recommended procedures for adequate blood pressure measurement. The other categories of health professionals (nursing and medicine teachers, physicians, residents, and nursing students) abided by approximately 70%. CONCLUSION: Permanent educational activities aiming at standardizing blood pressure measurement should be implemented among the different categories of health professionals.
Resumo:
East Germany, men, fertility, first births, event history analysis, problem-centered interviews, methodical integration, triangulation, social psychology, gender
Resumo:
Software engineering, software measurement, software process engineering, capability, maturity
Resumo:
Social intelligence
Resumo:
Magdeburg, Univ., Fak. für Informatik, Diss., 2009
Resumo:
Magdeburg, Univ., Fak. für Informatik, Diss., 2010