976 resultados para Carnegie institution of Washington
Resumo:
With the liberalisation of electricity market it has become very important to determine the participants making use of the transmission network.Transmission line usage computation requires information of generator to load contributions and the path used by various generators to meet loads and losses. In this study relative electrical distance (RED) concept is used to compute reactive power contributions from various sources like generators, switchable volt-amperes reactive(VAR) sources and line charging susceptances that are scattered throughout the network, to meet the system demands. The transmission line charge susceptances contribution to the system reactive flows and its aid extended in reducing the reactive generation at the generator buses are discussed in this paper. Reactive power transmission cost evaluation is carried out in this study. The proposed approach is also compared with other approaches viz.,proportional sharing and modified Y-bus.Detailed case studies with base case and optimised results are carried out on a sample 8-bus system. IEEE 39-bus system and a practical 72-bus system, an equivalent of Indian Southern grid are also considered for illustration and results are discussed.
Resumo:
A vibration isolator is described which incorporates a near-zero-spring-rate device within its operating range. The device is an assembly of a vertical spring in parallel with two inclined springs. A low spring rate is achieved by combining the equivalent stiffness in the vertical direction of the inclined springs with the stiffness of the vertical central spring. It is shown that there is a relation between the geometry and the stiffness of the individual springs that results in a low spring rate. Computer simulation studies of a single-degree-of-freedom model for harmonic base input show that the performance of the proposed scheme is superior to that of the passive schemes with linear springs and skyhook damping configuration. The response curves show that, for small to large amplitudes of base disturbance, the system goes into resonance at low frequencies of excitation. Thus, it is possible to achieve very good isolation over a wide low-frequency band. Also, the damper force requirements for the proposed scheme are much lower than for the damper force of a skyhook configuration or a conventional linear spring with a semi-active damper.
Resumo:
This article deals with a simulation-based Study of the impact of projectiles on thin aluminium plates using LS-DYNA by modelling plates with shell elements and projectiles with solid elements. In order to establish the required modelling criterion in terms of element size for aluminium plates, a convergence Study of residual velocity has been carried Out by varying mesh density in the impact zone. Using the preferred material and meshing criteria arrived at here, extremely good prediction of test residual velocities and ballistic limits given by Gupta et al. (2001) for thin aluminium plates has been obtained. The simulation-based pattern of failure with localized bulging and jagged edge of perforation is similar to the perforation with petalling seen in tests. A number Of simulation-based parametric studies have been carried out and results consistent with published test data have been obtained. Despite the robust correlation achieved against published experimental results, it would be prudent to conduct one's own experiments, for a final correlation via the present modelling procedure and analysis with the explicit LS-DYNTA 970 solver. Hence, a sophisticated ballistic impact testing facility and a high-speed camera have been used to conduct additional tests on grade 1100 aluminium plates of 1 mm thickness with projectiles Of four different nose shapes. Finally, using the developed numerical simulation procedure, an excellent correlation of residual velocity and failure modes with the corresponding test results has been obtained.
Resumo:
Rheumatoid arthritis (RA) and other chronic inflammatory joint diseases already begin to affect patients health-related quality of life (HRQoL) in the earliest phases of these diseases. In treatment of inflammatory joint diseases, the last two decades have seen new strategies and treatment options introduced. Treatment is started at an earlier phase; combinations of disease-modifying anti-rheumatic drugs (DMARDs) and corticosteroids are used; and in refractory cases new drugs such as tumour necrosis factor (TNF) inhibitors or other biologicals can be started. In patients with new referrals to the Department of Rheumatology of the Helsinki University Central Hospital, we evaluated the 15D and the Stanford Health Assessment Questionnaire (HAQ) results at baseline and approximately 8 months after their first visit. Altogether the analysis included 295 patients with various rheumatic diseases. The mean baseline 15D score (0.822, SD 0.114) was significantly lower than for the age-matched general population (0.903, SD 0.098). Patients with osteoarthritis (OA) and spondyloarthropathies (SPA) reported the poorest HRQoL. In patients with RA and reactive arthritis (ReA) the HRQoL improved in a statistically significant manner during the 8-month follow-up. In addition, a clinically important change appeared in patients with systemic rheumatic diseases. HAQ score improved significantly in patients with RA, arthralgia and fibromyalgia, and ReA. In a study of 97 RA patients treated either with etanercept or adalimumab, we assessed their HRQoL with the RAND 36-Item Health Survey 1.0 (RAND-36) questionnaire. We also analysed changes in clinical parameters and the HAQ. With etanercept and adalimumab, the values of all domains in the RAND-36 questionnaire increased during the first 3 months. The efficacy of each in improving HRQoL was statistically significant, and the drug effects were comparable. Compared to Finnish age- and sex-matched general population values, the HRQoL of the RA patients was significantly lower at baseline and, despite the improvement, remained lower also at follow-up. Our RA patients had long-standing and severe disease that can explain the low HRQoL also at follow-up. In a pharmacoeconomic study of patients treated with infliximab we evaluated medical and work disability costs for patients with chronic inflammatory joint disease during one year before and one year after institution of infliximab treatment. Clinical and economic data for 96 patients with different arthritis diagnoses showed, in all patients, significantly improved clinical and laboratory variables. However, the medical costs increased significantly during the second period by 12 015 (95% confidence interval, 6 496 to 18 076). Only a minimal decrease in work disability costs occurred mean decrease 130 (-1 268 to 1 072). In a study involving a switch from infliximab to etanercept, we investigated the clinical outcome in 49 patients with RA. Reasons for switching were in 42% failure to respond by American College of Rheumatology (ACR) 50% criteria; in 12% adverse event; and in 46% non-medical reasons although the patients had responded to infliximab. The Disease Activity Score with 28 joints examined (DAS28) allowed us to measure patients disease activity and compare outcome between groups based on the reason for switching. In the patients in whom infliximab was switched to etanercept for nonmedical reasons, etanercept continued to suppress disease activity effectively, and 1-year drug survival for etanercept was 77% (95% CI, 62 to 97). In patients in the infliximab failure and adverse event groups, DAS28 values improved significantly during etanercept therapy. However, the 1-year drug survival of etanercept was only 43% (95% CI, 26 to 70) and 50% (95% CI, 33 to 100), respectively. Although the HRQoL of patients with inflammatory joint diseases is significantly lower than that of the general population, use of early and aggressive treatment strategies including TNF-inhibitors can improve patients HRQoL effectively. Further research is needed in finding new treatment strategies for those patients who fail to respond or lose their response to TNF-inhibitors.
Resumo:
Pitfalls in the treatment of persons with dementia Persons with dementia require high-quality health care, rehabilitation and sufficient social services to support their autonomy and to postpone permanent institutionalization. This study sought to investigate possible pitfalls in the care of patients with dementia: hip fracture rehabilitation, use of inappropriate or antipsychotic medication, social and medicolegal services offered to dementia caregiving families. Three different Finnish samples were used from years 1999-2005, mean age 78 to 86 years. After hip fracture operation, the weight-bearing restriction especially in group of patients with dementia, was associated with a longer rehabilitation period (73.5 days vs. 45.5 days, p=0.03) and the inability to learn to walk after six weeks (p<0.001). Almost half (44%) of the pre-surgery home-dwellers with dementia in our sample required permanent hospitalization after hip fracture. Potentially inappropriate medication was used among 36.2% of nursing home and hospital patients. The most common PIDs in Finland were temazepam over 15 mg/day, oxybutynin, and dipyridamole. However, PID use failed to predict mortality or the use of health services. Nearly half (48.4%) of the nursing home and hospital patients with dementia used antipsychotic medication. The two-year mortality did not differ among the users of conventional or atypical antipsychotics or the non-users (45.3% vs.32.1% vs.49.6%, p=0.195). The mean number of hospital admissions was highest among non-users (p=0.029). A high number of medications (HR 1.12, p<0.001) and the use of physical restraints (HR 1.72, p=0.034) predicted higher mortality at two years, while the use of atypical antipsychotics (HR 0.49, p=0.047) showed a protective effect, if any. The services most often offered to caregiving families of persons with Alzheimer s disease (AD) included financial support from the community (36%), technical devices (33%), physiotherapy (32%), and respite care in nursing homes (31%). Those services most often needed included physiotherapy for the spouse with dementia (56%), financial support (50%), house cleaning (41%), and home respite (40%). Only a third of the caregivers were satisfied with these services, and 69% felt unable to influence the range of services offered. The use of legal guardians was quite rare (only 4.3%), while the use of financial powers of attorney was 37.8%. Almost half (47.9%) of the couples expressed an unmet need for discussion with their doctor about medico-legal issues, while only 9.9% stated that their doctor had informed them of such matters. Although we already have many practical methods to develop the medical and social care of persons with AD, these patients and their families require better planning and tailoring of such services. In this way, society could offer these elderly persons better quality of life while economizing on its financial resources. This study was supported by Social Insurance Institution of Finland and part of it made in cooperation with the The Central Union of the Welfare for the Aged, Finland.
Resumo:
A reliable protection against direct lightning hit is very essential for satellite launch pads. In view of this, suitable protection systems are generally employed. The evaluation of efficacy of the lightning protection schemes among others requires an accurate knowledge of the consequential potential rise at the struck point and the current injected into soil at the earth termination. The present work has made a detailed effort to deduce these quantities for the lightning protection scheme of the Indian satellite launch pad-I. A reduced scale model of the system with a frequency domain approach is employed for the experimental study. For further validation of the experimental approach, numerical simulations using numerical electromagnetic code-2 are also carried out on schemes involving single tower. The study results on the protection system show that the present design is quite safe with regard to top potential rise. It is shown that by connecting ground wires to the tower, its base current and, hence, the soil potential rise can be reduced. An evaluation of an alternate design philosophy involving insulated mast scheme is also made. The potential rise in that design is quantified and the possibility of a flashover to supporting tower is briefly looked into. The supporting tower is shown to have significant induced currents.
Resumo:
Autonomous mission control, unlike automatic mission control which is generally pre-programmed to execute an intended mission, is guided by the philosophy of carrying out a complete mission on its own through online sensing, information processing, and control reconfiguration. A crucial cornerstone of this philosophy is the capability of intelligence and of information sharing between unmanned aerial vehicles (UAVs) or with a central controller through secured communication links. Though several mission control algorithms, for single and multiple UAVs, have been discussed in the literature, they lack a clear definition of the various autonomous mission control levels. In the conventional system, the ground pilot issues the flight and mission control command to a UAV through a command data link and the UAV transmits intelligence information, back to the ground pilot through a communication link. Thus, the success of the mission depends entirely on the information flow through a secured communication link between ground pilot and the UAV In the past, mission success depended on the continuous interaction of ground pilot with a single UAV, while present day applications are attempting to define mission success through efficient interaction of ground pilot with multiple UAVs. However, the current trend in UAV applications is expected to lead to a futuristic scenario where mission success would depend only on interaction among UAV groups with no interaction with any ground entity. However, to reach this capability level, it is necessary to first understand the various levels of autonomy and the crucial role that information and communication plays in making these autonomy levels possible. This article presents a detailed framework of UAV autonomous mission control levels in the context of information flow and communication between UAVs and UAV groups for each level of autonomy.
Resumo:
Fractal Minkowski curves to design a compact dual-frequency microstrip ring antenna are proposed. Sides of a square ring have been selectively replaced with first and second iterations of the generalised fractal geometry to design a smaller antenna with dual-frequency operation. This behaviour has been explained based on current distributions on the antenna structure. Measured results compare well with electromagnetic simulations.
Resumo:
A switched rectifier DC voltage source three-level neutral-point-clamped (NPC) converter topology is proposed here to alleviate the inverter from capacitor voltage balancing in three-level drive systems. The proposed configuration requires only one DC link with a voltage of half of that needed in a conventional NPC inverter. To obtain a rated DC link voltage, the rectifier DC source is alternately connected in parallel to one of the two series capacitors using two switches and two diodes with device voltage ratings of half the total DC bus voltage. The frequency at which the voltage source is switched is independent of the inverter and will not affect its operation since the switched voltage source in this configuration balances the capacitors automatically. The proposed configuration can also be used as a conventional two-level inverter in the lower modulation index range, thereby increasing the reliability of the drivesystem. A space-vector-based PWM scheme is used to verify this proposed topology on a laboratory system.
Resumo:
A constant switching frequency current error space vector-based hysteresis controller for two-level voltage source inverter-fed induction motor (IM) drives is proposed in this study. The proposed controller is capable of driving the IM in the entire speed range extending to the six-step mode. The proposed controller uses the parabolic boundary, reported earlier, for vector selection in a sector, but uses simple, fast and self-adaptive sector identification logic for sector change detection in the entire modulation range. This new scheme detects the sector change using the change in direction of current error along the axes jA, jB and jC. Most of the previous schemes use an outer boundary for sector change detection. So the current error goes outside the boundary six times during sector change, in one cycle,, introducing additional fifth and seventh harmonic components in phase current. This may cause sixth harmonic torque pulsations in the motor and spread in the harmonic spectrum of phase voltage. The proposed new scheme detects the sector change fast and accurately eliminating the chance of introducing additional fifth and seventh harmonic components in phase current and provides harmonic spectrum of phase voltage, which exactly matches with that of constant switching frequency voltage-controlled space vector pulse width modulation (VC-SVPWM)-based two-level inverter-fed drives.
Resumo:
A two-stage pulse tube cryocooler (PTC) which produces a no-load temperature of similar to 2.5 K in its second stage at an operating frequency of 1.6 Hz has been designed and fabricated. The second stage of the system provides a refrigeration power of similar to 250 mW at 5.0 K. The system uses stainless steel meshes (mesh size 200) along with lead (Pb) granules and combinations of Pb, Er3Ni, and HoCu2 as the first and second stage regenerator materials, respectively. Experimental studies have been carried out on different pulse tube configurations by varying the dimensions of the pulse tubes and regenerators to arrive at the best one, which leads to the lowest no-load second stage cold head temperature. Using this configuration, detailed experimental studies have been conducted by varying the volume percentage ratios of the second stage regenerator materials such as HoCu2, Er3Ni, and Pb (with an average grain size of similar to 250 mu m). This article presents the results of our experimental studies on cryocoolers with the regenerator material arranged in layered structures. Comparative studies have also been presented for specific cases where the regenerator materials are arranged as a homogeneous mixture in the second stage. The experimental results clearly indicate that the design of PTCs should use only layered structures of regenerator materials and not homogenous mixtures.
Resumo:
Parliaments are political institutions, but they are also places where people work; the MPs and the people who are employed there work, albeit in rather different ways. In this research the focus is on those in a Parliament who work there as employees and managers, and thereby, in some senses, run the organisation. Accordingly, this involves seeing the Parliament as a working environment, for MPs and employees, for men and women. The institution of Parliament is thus here examined by looking at it from a different and new angle. Instead of the usual focus on politicians the focus is on the administration of this institution. The aim is, amongst other things, to increase knowledge and offer different perspectives on democracy and democratic institutions. Unpacking the nearly mythical institution into smaller, more digestible, graspable realities should at the very least help to remind the wider society that although nations, to a certain extent, do need national institutions they should not become mystified or seen as larger than life. Institutions should work on behalf of people and thus be accountable to these same people. The main contribution of this work is to explore and problematise how managing and working is done inside an institution that both largely fulfils the characteristics of a bureaucracy and yet also has added special features that seem to be rather far removed from clear bureaucratic structures. This research offers a new kind of information on working life inside this elite institution. The joys and the struggles of working and managing in this particular public sector organisation are illustrated here and offer a view, a glimpse, into the experiences of managing and working in this House.
Resumo:
A slip line field is proposed for symmetrical single‐cavity closed‐die forging by rough dies. A compatible velocity field is shown to exist. Experiments were conducted using lead workpiece and rough dies. Experimentally observed flow and load were used to validate the proposed slip line field. The slip line field was used to simulate the process in the computer with the objective of studying the influence of flash geometry on cavity filling.