922 resultados para CORNEAL ULCERS
Resumo:
Objective: There is little evidence regarding the benefit of stress ulcer prophylaxis (SUP) outside critical care setting. Over-prescription of SUP is not devoid of risks. This prospective study aimed to evaluate the use of proton pump inhibitors (PPIs) for SUP in a general surgery department.Methods: Data collection was performed prospectively during an 8-week period on patients hospitalized in a general surgery department (58 beds) by pharmacists. Patients with a PPI prescription for the treatment of ulcers, gastro-oesophageal reflux disease, oesophagitis or epigastric pain were excluded. Patients admitted twice during the study period were not re-included. The American Society of Health-System Pharmacists guidelines on SUP were used to assess the appropriateness of de novo PPI prescriptions.Results: Among 255 consecutive patients in the study, 138 (54%) received a prophylaxis with PPI, of which 86 (62%) were de novo PPI prescriptions. One-hundred twenty-nine patients (94%) received esomeprazole (according to the hospital drug policy). The most frequent dosage was 40 mg/day. Use of PPI for SUP was evaluated in 67 patients. Fifty-three patients (79%) had no risk factors for SUP. Twelve and 2 patients had one or two risk factors, respectively. At discharge, PPI prophylaxis was continued in 34% of patients with a de novo PPI prescription.Conclusion: This study highlights the overuse of PPIs in non-ICU patients and the inappropriate continuation of PPI prescriptions at discharge.Treatment
Resumo:
Fecal calprotectin (FC) is a valid biomarker to discriminate with a good sensitivity and specificity the presence of mucosal lesions of the gastrointestinal tube (e.g. ulcers in the context of inflammatory bowel disease (IBD)) from functional disorders (e.g. irritable bowel syndrome). FC is not specific for IBD and can be elevated also in gastrointestinal infections, ischemic colitis or neoplasia. An elevated FC should stimulate further investigations, notably an endoscopic workup. The level of FC correlates with the endoscopic score in Crohn's disease and ulcerative colitis. The correlation of FC and the endoscopic severity is better than the one of CRP or blood leukocytes. Thus, FC can also be used in the follow-up of IBD patients.
Resumo:
A 56-year-old female patient displayed an increased volume of her left lacrimal gland with pain and inflammation. On CT scan, a hyperdense lacrimal mass was found in the left lacrimal fossa. Observation was the first course, for no steroid therapy could be applied because of evolving digestive ulcers. After 9 months of observation, the gland was surgically removed en bloc through a wide anterolateral approach. Pathological analysis of the gland showed a pleomorphic adenoma. This case illustrates the advantage of a wide surgical approach in treating lacrimal gland tumors, in order to avoid or limit the risk of recurrence.
Resumo:
Purpose: In vitro studies in porcine eyes have demonstrated a good correlation between induced intraocular pressure variations and corneal curvature changes, using a contact lens with an embedded microfabricated strain gauge. Continuous 24 hour-intraocular pressure (IOP) monitoring to detect large diurnal fluctuation is currently an unmet clinical need. The aims of this study is to evaluate precision of signal transmission and biocompatibility of 24 hour contact lens sensor wear (SENSIMED Triggerfish®) in humans. Methods: After full eye examination in 10 healthy volunteers, a 8.7 mm radius contact lens sensor and an orbital bandage containing a loop antenna were applied and connected to a portable recorder. Best corrected visual acuity and position, lubrication status and mobility of the sensor were assessed after 5 and 30 minutes, 4, 7 and 24 hours. Subjective comfort was scored and activities documented in a logbook. After sensor removal full eye examination was repeated, and the registration signal studied. Results: The comfort score was high and did not fluctuate significantly, except at the 7 hour-visit. The mobility of the contact lens was minimal but its lubrication remained good. Best corrected visual acuity was significantly reduced during the sensor wear and immediately after its removal. Three patients developed mild corneal staining. In all but one participant we obtained a registration IOP curve with visible ocular pulse amplitude. Conclusions: This 24 hour-trial confirmed the functionality and biocompatibility of SENSIMED Triggerfish® wireless contact lens sensor for IOP-fluctuation monitoring in volunteers. Further studies with a range of different contact lens sensor radii are indicated.
Resumo:
OBJECTIVE: Evaluate the hospital impact of diabetes, foot ulcers and amputations linked to diabetic foot in Switzerland. METHODS: Data from the medical statistics of Swiss hospitals between 2003 and 2008. RESULTS: Over 6 years, the annual hospital admission rate of diabetic patients increased by 38%, the number of hospitalised patients and of admissions by 44% and 51%, respectively. For ulcers, these figures were 112% and 194%, and for amputations 26% and 34%, respectively. Amongst patients hospitalised in 2005 with ulcer or for amputation, about 25% were hospitalised 2 years and 33% 1 year before or after. Length of stay decreased by 10%, but hospital mortality remained stable below 10%. CONCLUSION: Hospital admissions with diabetic foot problems are an important public health issue, and are getting worse.
Resumo:
Las úlceras neuropáticas es una de las complicaciones que con más frecuencia presenta el paciente diabético. El principal objetivo en el tratamiento de las úlceras neuropáticas es potenciar los mecanismos fisiológicos de cicatrización, para ello es necesario actuar sobre los factores que retrasan este proceso. Uno de los principales factores que actúan como desencadenante y agravante en la aparición de una úlcera neuropática es el aumento de la presión plantar, condicionada por una alteración en el apoyo ya sea por causa estructural o biomecánica, al mismo tiempo esta hiperpresión continuada actúa retrasando los mecanismos de cicatrización. El método que ha demostrado mayor efectividad es el tratamiento de las úlceras neuropáticas plantares es el tratamiento con descargas. Vamos a exponer en este trabajo las diferentes técnicas de descarga que se pueden utilizar para tratar una ulcera neuropática a nivel ambulatorio.
Resumo:
OBJECTIVES: To review and update the evidence on predictors of poor outcome (death, persistent vegetative state or severe neurological disability) in adult comatose survivors of cardiac arrest, either treated or not treated with controlled temperature, to identify knowledge gaps and to suggest a reliable prognostication strategy. METHODS: GRADE-based systematic review followed by expert consensus achieved using Web-based Delphi methodology, conference calls and face-to-face meetings. Predictors based on clinical examination, electrophysiology, biomarkers and imaging were included. RESULTS AND CONCLUSIONS: Evidence from a total of 73 studies was reviewed. The quality of evidence was low or very low for almost all studies. In patients who are comatose with absent or extensor motor response at ?72h from arrest, either treated or not treated with controlled temperature, bilateral absence of either pupillary and corneal reflexes or N20 wave of short-latency somatosensory evoked potentials were identified as the most robust predictors. Early status myoclonus, elevated values of neuron specific enolase at 48-72h from arrest, unreactive malignant EEG patterns after rewarming, and presence of diffuse signs of postanoxic injury on either computed tomography or magnetic resonance imaging were identified as useful but less robust predictors. Prolonged observation and repeated assessments should be considered when results of initial assessment are inconclusive. Although no specific combination of predictors is sufficiently supported by available evidence, a multimodal prognostication approach is recommended in all patients.
Resumo:
INTRODUCTION: Inhalation injury is an important determinant of outcome in patients with major burns. However the diagnostic criteria remain imprecise, preventing objective comparisons of published data. The aims were to evaluate the utility of an inhalation score based on mucosal injury, while assessing separately the oro-pharyngeal sphere (ENT) and tracheobronchial tree (TB) in patients admitted to the ICU with a suspicion of inhalation injury. METHODS: Prospective observational study in 100 patients admitted with suspicion of inhalation injury among 168 consecutive burn admissions to the ICU of a university hospital. Inclusion criteria, endoscopic airway assessment during the first hours. ENT/TB lesion grading was 1: oedema, hyperemia, hypersecretion, 2: bullous mucosal detachment, erosion, exudates, 3: profound ulcers, necrosis. RESULTS: Of the 100 patients (age 42±17 years, burns 23±19%BSA), 79 presented an ENT inhalation injury ≥ENT1 (soot present in 24%): 36 had a tracheobronchial extension, 33 having a grade ≥TB1. Burned vibrissae: 10 patients "without" suffered ENT injury, while 6 patients "with" had no further lesions. Length of mechanical ventilation was strongly associated with the first 24 hrs' fluid resuscitation volume (p<0.0001) and the presence of inhalation injury (p=0.03), while the ICU length of stay was correlated with the %BSA. Soot was associated with prolonged mechanical ventilation (p=0.0115). There was no extubation failure. CONCLUSIONS: The developed inhalation score was simple to use, providing a unified language, and drawing attention to upper airway involvement. Burned vibrissae and suspected history proved to be insufficient diagnostic criteria. Further studies are required to validate the score in a larger population.
Resumo:
PURPOSE: To describe the use of anterior segment optical coherence tomography (AS-OCT) to clarify the position and patency of aqueous shunt devices in the anterior chamber of eyes where corneal edema or tube position does not permit a satisfactory view. DESIGN: Noncomparative observational case series. METHODS: Four cases are reported in which aqueous shunt malposition or obstruction was suspected but the shunt could not be seen on clinical examination. The patients underwent AS-OCT to identify the position and patency of the shunt tip. RESULTS: In each case, AS-OCT provided data regarding tube position and/or patency that could not be obtained by slit-lamp examination or by gonioscopy that influenced management. CONCLUSIONS: AS-OCT can be used to visualize anterior chamber tubes in the presence of corneal edema that precludes an adequate view or in cases where the tube is retracted into the cornea. In such cases, AS-OCT is useful in identifying shunt patency and position, which helps guide clinical decision making.
Resumo:
Cyclosporine A is a poorly water-soluble, immunosuppressive drug used to treat a variety of ocular diseases. Its limited solubility makes challenging the development of a cyclosporine A-based eye drop for ocular topical application. Based on the prodrug strategy, the practically insoluble cyclosporine A was converted into a freely soluble prodrug. Such a water-soluble prodrug made it possible to develop water-based concentrated eye drops. The prodrug formulations were tested for their ex vivo permeation and in vivo distribution at three concentrations (equivalent to 0.05%, 0.50% and 2.00% w/v cyclosporine A). The ex vivo permeation experiments were performed on corneal and conjunctival epithelia. The in vivo distribution evaluated the total cyclosporine A present in the ocular structures as well as in serum, spleen and cervical lymphatic ganglions. Each prodrug formulation was compared to conventionally used cyclosporine A eye drops at an equivalent concentration. The experimental results showed that the tested eye drops behaved differently. The prodrug formulation was characterized by the following: i) preferential conjunctival penetration, ii) an interesting capacity to create large tissue deposits and iii) a lower risk of systemic complications and immunosuppression. The prodrug aqueous eye drop was demonstrated to be a patient-friendly option for the treatment of ocular diseases requiring high ocular levels of cyclosporine A, pushing the boundaries of the current therapeutic arsenal.
Resumo:
Purpose: To evaluate inter- and intraobserver variability of indices crucial for detection of keratoconus progression derived from the Pentacam HR® (high-resolution) tomographer (OCULUS Optikgeräte GmbH, Wetzlar, Germany) in patients with mild to moderate keratoconus. Methods: Three repeated corneal topography measurements in the 25-picture mode by two independent observers were performed. The extent of variability across a large range of measurement parameters was analyzed including anterior and posterior corneal surface measurements, pachymetry values, corneal volume, anterior chamber volume and depth, and iridocorneal angle. The intraclass correlation coefficient (ICC) between and within each investigator was calculated to assess reproducibility and repeatability, respectively. Results: 31 eyes of 20 patients (mean age 31.6, SD ± 8.6) were included. Overall, the repeatability and reproducibility were excellent. The range of variability was reported by calculating the standard deviation of measurements. The detailed results are shown in Table 1. Conclusions: This study shows that the Pentacam HR® tomographer provides reliable measurements in patients with mild to moderate keratoconus. However, all parameters showed a certain range of variability. This should be taken into account when assessing keratoconus progression in order to distinguish true progression from variability in measurements. In addition, the excellent reproducibility suggests that the measurements can be reliably performed by different individuals from one visit to another.
Resumo:
The development of new drug delivery systems to target the anterior segment of the eye may offer many advantages: to increase the biodisponibility of the drug, to allow the penetration of drug that cannot be formulated as solutions, to obtain constant and sustained drug release, to achieve higher local concentrations without systemic effects, to target more specifically one tissue or cell type, to reduce the frequency of instillation and therefore increase the observance and comfort of the patient while reducing side effects of frequent instillation. Several approaches are developed, aiming to increase the corneal contact time by modified formulation or reservoir systems, or by increasing the tissue permeability using iontophoresis. To date, no ocular drug delivery system is ideal for all purposes. To maximize treatment efficacy, careful evaluation of the specific pathological condition, the targeted Intraocular tissue and the location of the most severe pathology must be made before selecting the method of delivery most suitable for each individual patient.
Resumo:
Introduction: Roux-en-Y gastric bypass (RYGBP) is one of the commonest procedure for morbid obesity. It is associated with effective long-term weight loss, but can lead to significant complications, especially at the gastrojejunostomy (GJS) Patients and Methods: All the patients undergoing laparoscopic RYGBP at one of our two institutions were included in this study, in which we compared two different techniques for the construction of the GJS and their effects on the incidence of complications. In group A, anatomosis was performed on the posterior aspect of the gastric pouch. In group B it was performed across the staple line used to form the gastric pouch. A 21-mm circular stapler was used in all patients. Results: A total of 1128 patients were included between June 1999 and September 2009, 639 in group A and 488 in group B. Sixty patients developed a total of 65 complications at the GJS, with 14 (1,2 %) leaks, 42 (3,7 %) stricture, and 9 (0,8 %) marginal ulcers. Leaks (0,2 versus 2 %, p=0,005) and strictures (0,8 versus 5,9%, p<0,0001) were significantly fewer in group B than in group A. Conclusions: Improved surgical technique, with the GJS across the staple line used to form the gastric pouch, significantly reduces the rate of anastomotic complications at the GJS. A circular 21-mm stapler can be used with a low complication rate, and especially a low stricture rate. Additional methods to limit complications at the GJS are probably not routinely warranted.
Resumo:
Given that retroposed copies of genes are presumed to lack the regulatory elements required for their expression, retroposition has long been considered a mechanism without functional relevance. However, through an in silico assay for transcriptional activity, we identify here >1,000 transcribed retrocopies in the human genome, of which at least approximately 120 have evolved into bona fide genes. Among these, approximately 50 retrogenes have evolved functions in testes, more than half of which were recruited as functional autosomal counterparts of X-linked genes during spermatogenesis. Generally, retrogenes emerge "out of the testis," because they are often initially transcribed in testis and later evolve stronger and sometimes more diverse spatial expression patterns. We find a significant excess of transcribed retrocopies close to other genes or within introns, suggesting that retrocopies can exploit the regulatory elements and/or open chromatin of neighboring genes to become transcribed. In direct support of this hypothesis, we identify 36 retrocopy-host gene fusions, including primate-specific chimeric genes. Strikingly, 27 intergenic retrogenes have acquired untranslated exons de novo during evolution to achieve high expression levels. Notably, our screen for highly transcribed retrocopies also uncovered a retrogene linked to a human recessive disorder, gelatinous drop-like corneal dystrophy, a form of blindness. These functional implications for retroposition notwithstanding, we find that the insertion of retrocopies into genes is generally deleterious, because it may interfere with the transcription of host genes. Our results demonstrate that natural selection has been fundamental in shaping the retrocopy repertoire of the human genome.
Resumo:
PURPOSE: The aim of the present study was the in vitro and in vivo evaluation of a novel aqueous formulation based on polymeric micelles for the topical delivery of cyclosporine A for dry eye treatment. METHODS: In vitro experiments were carried out on primary rabbit corneal cells, which were characterized by immunocytochemistry using fluorescein-labeled lectin I/isolectin B4 for the endothelial cells and mouse monoclonal antibody to cytokeratin 3+12 for the epithelial ones. Living cells were incubated for 1 hour or 24 hours with a fluorescently labeled micelle formulation and analyzed by fluorescence microscopy. In vivo evaluations were done by Schirmer test, osmolarity measurement, CyA kinetics in tears, and CyA ocular distribution after topical instillation. A 0.05% CyA micelle formulation was compared to a marketed emulsion (Restasis). RESULTS: The in vitro experiments showed the internalization of micelles in the living cells. The Schirmer test and osmolarity measurements demonstrated that micelles did not alter the ocular surface properties. The evaluation of the tear fluid gave similar CyA kinetics values: AUC = 2339 ± 1032 min*μg/mL and 2321 ± 881.63; Cmax = 478 ± 111 μg/mL and 451 ± 74; half-life = 36 ± 9 min and 28 ± 9 for the micelle formulation and Restasis, respectively. The ocular distribution investigation revealed that the novel formulation delivered 1540 ± 400 ng CyA/g tissue to the cornea. CONCLUSIONS: The micelle formulation delivered active CyA into the cornea without evident negative influence on the ocular surface properties. This formulation could be applied for immune-related ocular surface diseases.