986 resultados para Alveolar proteinosis


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: This study evaluated the influence of distal extension removable partial denture associated with implant in cases of different bone level of abutment tooth, using 2D finite element analysis.Materials and Methods: Eight hemiarch models were simulated: model A-presenting tooth 33 and distal extension removable partial denture replacing others teeth, using distal rest connection and no bone lost; model B-similar to model A but presenting distal guide plate connection; model C-similar to model A but presenting osseointegrated implant with ERA retention system associated under prosthetic base; model D-similar to model B but presenting osseointegrated implant as described in model C; models E, F, G, and H were similar to models A, B, C, and D but presenting reduced periodontal support around tooth 33. Using ANSYS 9.0 software, the models were loaded vertically with 50 N on each cusp tip. For results, von Mises Stress Maps were plotted.Results: Maximum stress value was encountered in model G (201.023 MPa). Stress distribution was concentrated on implant and retention system. The implant/removable partial denture association decreases stress levels on alveolar mucosa for all models.Conclusions: Use of implant and ERA system decreased stress concentrations on supporting structures in all models. Use of distal guide plate decreased stress levels on abutment tooth and cortical and trabecular bone. Tooth apex of models with reduced periodontal support presented increased stress when using distal rest. (Implant Dent 2011;20:192-201)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: The purpose of this study was to compare the dental movement that occurs during the processing of maxillary complete dentures with 3 different base thicknesses, using 2 investment methods, and microwave polymerization.Methods: A sample of 42 denture models was randomly divided into 6 groups (n = 7), with base thicknesses of 1.25, 2.50, and 3.75 mm and gypsum or silicone flask investment. Points were demarcated on the distal surface of the second molars and on the back of the gypsum cast at the alveolar ridge level to allow linear and angular measurement using AutoCAD software. The data were subjected to analysis of variance with double factor, Tukey test and Fisher (post hoc).Results: Angular analysis of the varying methods and their interactions generated a statistical difference (P = 0.023) when the magnitudes of molar inclination were compared. Tooth movement was greater for thin-based prostheses, 1.25 mm (-0.234), versus thick 3.75 mm (0.2395), with antagonistic behavior. Prosthesis investment with silicone (0.053) showed greater vertical change compared with the gypsum investment (0.032). There was a difference between the point of analysis, demonstrating that the changes were not symmetric.Conclusions: All groups evaluated showed change in the position of artificial teeth after processing. The complete denture with a thin base (1.25 mm) and silicone investment showed the worst results, whereas intermediate thickness (2.50 mm) was demonstrated to be ideal for the denture base.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: The aim of this research was to assess, by means of, the bi-dimensional finite element method, the best implant location in the alveolar edge, through stress distribution and support structure displacement of a distal extension removable partial denture associated with an osseointegrated implant of 10.0 x .75 mm, acting as abutment for the denture base.Methods and Materials: Five models in sagittal cut were used to represent: model A-hemi arch containing natural tooth 33 and the distal alveolar edge; model B-similar to model A, but with a conventional removable partial denture to replace the absent teeth; model C (MC)-similar to the previous one, with an implant in the distal region of the edge under the denture base; model D-similar to MC, with the implant in the central region of the edge; model E-similar to MC, with an implant in the mesial region of the edge. With the aid of the finite element program ANSYS 8.0, the models were loaded with strictly vertical forces of 50 N on each cusp tip. Displacement and von Mises Maps were plotted for visualization of results.Results: The introduction of implant diminished the tendency of intrusion of the removable partial denture in all situations. The maximum stress was observed on implant in all situations. Approximating implant in direction of support teeth was benefit for stress distribution.Conclusion: Model D presented the lowest value for maximum tendency to displacement when compared with those found in the other models; model E demonstrated better relief with regard to demand from the abutment tooth; locating the implant near of the abutment tooth influenced positively the distribution of stresses on the analyzed structures.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: The non-homogenous aspect of periodontal ligament (PDL) has been examined using finite element analysis (FEA) to better simulate PDL behavior. The aim of this study was to assess, by 2-D FEA, the influence of non-homogenous PDL on the stress distribution when the free-end saddle removable partial denture (RPD) is partially supported by an osseointegrated implant. Material and Methods: Six finite element (FE) models of a partially edentulous mandible were created to represent two types of PDL (non-homogenous and homogenous) and two types of RPD (conventional RPD, supported by tooth and fibromucosa; and modified RPD, supported by tooth and implant [10.00x3.75 mm]). Two additional FE models without RPD were used as control models. The non-homogenous PDL was modeled using beam elements to simulate the crest, horizontal, oblique and apical fibers. The load (50 N) was applied in each cusp simultaneously. Regarding boundary conditions the border of alveolar ridge was fixed along the x axis. The FE software (Ansys 10.0) was used to compute the stress fields, and the von Mises stress criterion (sigma vM) was applied to analyze the results. Results: The peak of sigma vM in non-homogenous PDL was higher than that for the homogenous condition. The benefits of implants were enhanced for the non-homogenous PDL condition, with drastic sigma vM reduction on the posterior half of the alveolar ridge. The implant did not reduce the stress on the support tooth for both PDL conditions. Conclusion: The PDL modeled in the non-homogeneous form increased the benefits of the osseointegrated implant in comparison with the homogeneous condition. Using the non-homogenous PDL, the presence of osseointegrated implant did not reduce the stress on the supporting tooth.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJETIVO: avaliar as diferenças produzidas nas dimensões e forma de arco pelos tratamentos com aparelho expansor fixo tipo Hyrax e aparelho expansor removível tipo Placa de Hawley com parafuso expansor palatino centralizado. MATERIAL E MÉTODOS: foram selecionados modelos de estudo iniciais e finais de 31 crianças portadoras de mordida cruzada posterior, de ambos os gêneros, de origem étnica diversa e na fase da dentadura mista, tratadas nos cursos de Graduação e Pós-Graduação em Ortodontia do Departamento de Clínica Infantil da Faculdade de Odontologia de Araraquara - UNESP. Destas crianças, 15 foram tratadas com uso do aparelho expansor fixo tipo Hyrax e as demais 16 crianças foram tratados com expansão rápida da maxila efetuada com o aparelho expansor fixo. Foram realizadas medidas das distâncias intercaninos e intermolares, da inclinação do processo alveolar e inclinação dentária nas imagens escaneadas do arco superior e do contorno do palato, obtido com auxílio de um template ajustável e do programa de análises Radiocef Studio. RESULTADOS E CONCLUSÕES: os resultados indicam uma mudança significante nas distâncias intercaninos e intermolares em ambos os grupos e uma inclinação dentária e do processo alveolar para vestibular significante no grupo tratado com o aparelho expansor fixo. A expansão conseguida pelo aparelho expansor fixo foi aproximadamente o dobro da promovida pelo aparelho expansor removível.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJETIVO: Apresentar revisão de literatura sobre dentes natais e neonatais, abordando características clínicas, fatores etiológicos, medidas terapêuticas e a importância do conhecimento desta anomalia, por odontopediatras e pediatras. FONTES DE DADOS: Foram selecionados os artigos mais relevantes sobre o tema, desde 1950 até 2006, pesquisados no Medline e na Bibliografia Brasileira em Odontologia (BBO), além de livros de pertinentes. SÍNTESE DOS DADOS: Os dentes natais e neonatais consistem em uma anomalia de erupção, sendo caracterizados por seu irrompimento na cavidade oral durante o período intra-uterino ou no primeiro mês de vida respectivamente, podendo fazer parte da dentição decídua normal ou supranumerária. Esses dentes, em geral, apresentam bordos cortantes e podem estar relacionados ao aparecimento de ulcerações na base da língua do bebê e/ou no seio materno, comprometendo a amamentação. A fraca implantação óssea desses dentes favorece sua grande mobilidade, tornando-se, assim, um fator de risco à sua aspiração ou deglutição pela criança. A abordagem terapêutica depende da dentição à qual pertence o dente e dos possíveis problemas que este pode causar à saúde da criança ou da mãe. CONCLUSÕES: O conhecimento sobre as características clínicas e os possíveis distúrbios aos quais os dentes natais e neonatais estão relacionados por odontopediatras e pediatras possibilita a interação necessária para o diagnóstico precoce e a abordagem integral da criança.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Intrusion of permanent teeth is one of the most severe types of traumatic injuries. Different treatment strategies have been proposed, and the best approach for each case depends on the stage of root development, severity of the intrusive luxation, presence of alveolar fracture and number of intruded teeth. The purpose of this paper is to describe the treatment management of 2 cases of severely intruded immature permanent maxillary central incisors in 71/2- and 8-year-old children. In case 1, the traumatized tooth was treated by surgical repositioning, while in case 2 watchful waiting for spontaneous re-eruption was the treatment of choice. Treatment strategies were successful in both cases, as demonstrated by the continuation of root development, maintenance of pulp vitality, and absence of signs of per/apical pathosis during the follow-up period. Regardless of the treatment strategy, traumatically intruded teeth should undergo periodical clinical and radiographic surveillance on a long-term basis to allow early detection of possible complications. (Pediotr Dent 2009;31:340-5) Received March 11, 2008 vertical bar Last Revision June 25, 2008 vertical bar Revision Accepted July 16, 2008

Relevância:

10.00% 10.00%

Publicador:

Resumo:

INTRODUÇÃO: o problema transversal em Ortodontia pode ser de origem dentária, esquelética ou uma combinação de ambas e pode ser tratado de várias maneiras de acordo com o tipo de tecido envolvido e o arco dentário acometido. em se tratando de um problema esquelético e maxilar, o ortodontista poderá lançar mão da disjunção ortopédica, dependendo da idade óssea, obtendo uma correção da atresia, um alinhamento dentário espontâneo resultante do aumento no perímetro do arco e um sorriso mais amplo, beneficiando esteticamente o paciente. Porém, este tratamento de disjunção mandibular se torna inviável, já que este osso tem sua sutura fusionada precocemente. A expansão neste caso é alveolar e sua estabilidade é questionada. OBJETIVO: relatar um caso clínico, apresentando uma nova alternativa de tratamento para o apinhamento inferior: a Distração Osteogênica da Sínfise Mandibular (DOSM). Neste procedimento, é feita uma osteotomia sagital na sínfise, criando-se uma sutura artificial para que uma separação óssea seja conseguida, utilizando uma mecânica com aparelho disjuntor de Hyrax modificado. RESULTADOS: os resultados do tratamento apresentado mostram uma melhora na forma do arco, diminuição do corredor bucal, correção do apinhamento dentário e também uma estabilidade do tratamento, sem dano aos tecidos adjacentes. Neste caso clínico, a DOSM se mostrou uma excelente opção de tratamento.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: Periodontitis is a well-appreciated example of leukocyte-mediated bone loss and inflammation with pathogenic features similar to those observed in other inflammatory diseases, such as arthritis. Since Tacrolimus, is an immunomodulatory drug used for the treatment of some cases of arthritis, we hypothesized that it may modulate periodontal disease.Design: Using a murine model of ligature-induced periodontal disease, we assessed the effects of daily administrations of Tacrolimus (1 mg/kg body weight) on bone loss, enzymatic (myeloperoxidase) analysis, differential white blood cells counts, airpouch exudate and cytokine expression for 5-30 days.Results: Radiographic, enzymatic (myeloperoxidase) and histological analysis revealed that Tacrolimus reduced the severity of periodontitis. More specifically, Tacrolimus suppressed the expression of serum interleukin (IL-1 beta), tumour necrosis factor (TNF-alpha), IL-6, airpouch exudate PGE(2) and leukocytosis usually observed after the induction of periodontitis. Tacrolimus treatment in periodontitis-induced rats conferred protection against the inflammation-induced tissue and bone loss associated with periodontitis, through a mechanism involving IL-1 beta, TNF-alpha and IL-6.Conclusions: the effects of Tacrolimus on periodontal disease pathogenesis may provide clues to a novel approach to host modulation therapy in destructive periodontal disease. (C) 2007 Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives: (1) To evaluate the intraobserver agreement related to image interpretation and (2) to compare the accuracy of 100%, 200% and 400% zoomed digital images in the detection of simulated periodontal bone defects.Methods: Periodontal bone defects were created in 60 pig hemi-mandibles with slow-speed burs 0.5 mm, 1.0 mm, 1.5 mm, 2.0 mm and 3.0 mm in diameter. 180 standardized digital radiographs were made using Schick sensor and evaluated at 100%, 200% and 400% zooming. The intraobserver agreement was estimated by Kappa statistic (kappa). For the evaluation of diagnostic accuracy receiver operating characteristic (ROC) analysis was performed followed by chi-square test to compare the areas under ROC curves according to each level of zooming.Results: For 100%, 200% and 400% zooming the intraobserver agreement was moderate (kappa = 0.48, kappa = 0.54 and kappa = 0.43, respectively) and there were similar performances in the discrimination capacity, with ROC areas of 0.8611 (95% CI: 0.7660-0.9562), 0.8600 (95% CI: 0.7659-0.9540), and 0.8368 (95% CI: 0.7346-0.9390), respectively, with no statistical significant differences (chi(2)-test; P = 0.8440).Conclusions: A moderate intraobserver agreement was observed in the classification of periodontal bone defects and the 100%, 200% and 400% zoomed digital images presented similar performances in the detection of periodontal bone defects.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: the failure of osseointegration in oral rehabilitation has gained importance in current literature and in clinical practice. The integration of titanium dental implants in alveolar bone has been partly ascribed to the biocompatibility of the implant surface oxide layer. The aim of this investigation was to analyze the surface topography and composition of failed titanium dental implants in order to determine possible causes of failure.Methods: Twenty-one commercially pure titanium (cpTi) implants were retrieved from 16 patients (mean age of 50.33 +/- 11.81 years). Fourteen implants were retrieved before loading (early failures), six after loading (late failures), and one because of mandibular canal damage. The failure criterion was lack of osseointegration characterized as dental implant mobility. Two unused implants were used as a control group. All implant surfaces were examined by scanning electron microscopy (SEM) and energy-dispersive spectrometer x-ray (EDS) to element analysis. Evaluations were performed on several locations of the same implant.Results: SEM showed that the surface of all retrieved implants consisted of different degrees of organic residues, appearing mainly as dark stains. The surface topography presented as grooves and ridges along the machined surface similar to control group. Overall, foreign elements such as carbon, oxygen, sodium, calcium, silicon, and aluminum were detected in failed implants. The implants from control group presented no macroscopic contamination and clear signs of titanium.Conclusion: These preliminary results do not suggest any material-related cause for implant failures, although different element composition was assessed between failed implants and control implants.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A proposta do presente estudo foi de analisar, através de análise cefalométrica por telerradiografias de perfil, a altura óssea na região mandibular anterior após a realização de vestibuloplastia pela técnica de inversão de retalhos. Foram avaliados 13 pacientes (8 mulheres e 5 homens), com média igual a 54,3 anos que apresentavam, em média, 25,01 mm de altura mandibular anterior. As medidas foram obtidas utilizando-se traçado cefalométrico e comparando-se o período pré-operatório com os períodos pós-operatórios, que consistiram de 30, 90 e 180 dias. Durante o período analisado, houve uma redução da altura mandibular anterior, estatisticamente não significante, de 0,6 mm.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Osteodistraction is a clinical reality available for the resolution of bone deficiencies before dental implant placement or in cases where the existing implants are at the wrong position. The objective of this study is to suggest a new possibility for bone distraction, based on tooth-implant bone distractors, in areas were there is the need for extensive alveolar bone recovery, with installed dental implants. This technique presented good results associated with its simplicity and low cost, making it a viable clinical solution for bone tissue augmentation. Although its use is recent, the suggested technique shows the potential to become used widely in attempts to achieve bone-height augmentation, primarily when dental implants are installed and osteointegrated already. (C) 2008 American Association of Oral and Maxillofacial Surgeons