997 resultados para 7,7,8,8-Tetracyanoquinodimethane
Resumo:
Aim: To characterise clinically the patients with C4d in peritubular capillaries deposits (C4dPTCD) and/or circulating anti-HLA class I/II alloantibodies. To determine the correlation between positive C4dPTCD and circulating anti-HLA class I/II alloantibodies during episodes of graft dysfunction. Subjects and Methods: C4d staining was performed in biopsies with available frozen tissue obtained between January 2004 and December 2006. The study was prospective from March 2005, when a serum sample was obtained at the time of biopsy to detect circulating anti-HLA class I/II alloantibodies. Results: We studied 109 biopsies in 86 cadaver renal transplant patients. Sixteen of these (14.7%) presented diffuse positive C4dPTCD. There was a 13.5% rate of +C4dPTCD incidence within the first six months of transplantation and 16% after six months (p>0.05). Half of the +C4dPTCD in the first six months was associated with acute humoral rejection. After six months, the majority of +C4dPTCD (n=7/8) was present in biopsies with evidence of interstitial fibrosis/tubular atrophy and/or transplant glomerulopathy. The C4dPTCD was more frequent in patients with positive anti-HCV antibodies(p<0.0001), a previous renal transplant (p=0.007), and with a panel reactivity antibody (PRA) ≥ 50%(p=0.0098). The anti-HCV+ patients had longer time on dialysis (p=0.0019) and higher PRA(p=0.005). Circulating anti-HLA I/II alloantibodies were screened in 46 serum samples. They were positive in 10.9% of samples, all obtained after six months post transplant. Circulating alloantibodies were absent in 92.5% of the C4d negative biopsies. Conclusion: We found an association between the presence of C4dPTCD and 2nd transplant recipients,higher PRA and the presence of anti-HCV antibodies. The presence of HCV antibodies is not a risk factor for C4dPTCD per se, but appears to reflect longer time on dialysis and presensitisation. In renal dysfunction a negative alloantibody screening is associated with a reduced risk of C4dPTCD (<10%).
Resumo:
Este documento apresenta uma avaliação sobre o uso dos simuladores fisiológicos como padrão para avaliação metrológica dos esfigmomanómetros automáticos na estimação da pressão sanguínea pelo método não invasivo (PNI). O presente estudo procurou avaliar o enquadramento destes equipamentos com os procedimentos das normas e recomendações usadas para apreciação metrológica dos esfigmomanómetros digitais. No contexto da prática metrológica existente determinou-se a existência de uma oportunidade de melhoria nos processos relacionados. O trabalho procurou obter resposta a diversas questões, relacionando a medição da pressão pelo método não invasivo, com o uso dos simuladores fisiológicos, o contexto em que estes podem ser usados, as formas de simulação, as medições e os resultados, procurando a perspetiva metrológica como enquadramento. As recomendações existentes [1] [2] [3] [4] [5] [6] [7] [8], são muito claras nos procedimentos, validação e nos desvios permitidos para os monitores da tensão arterial (MTA), equipamento que permite a avaliação dos parâmetros fisiológicos do paciente, no entanto, quando se pretende avançar para outro domínio, como o do uso dos simuladores, em particular para a simulação da PNI, não existem recomendações ou normas tão claras, e não existe sobretudo um padrão de referência que imite a natureza dinâmica que caracteriza a pressão sanguínea. O trabalho procurou ainda estabelecer a ligação entre o método clássico de auscultação (o principio de determinação da PS), a técnica digital de medição e os simuladores, para uma melhor compreensão do que é a pressão sanguínea, e como relacionar a problemática da simulação e a de um padrão de referência. Neste trabalho estão ainda presentes abordagens a diversos tópicos, como as validações clínicas, acessórios, ou a metrologia e que influenciam no final os equipamentos e o contexto que se pretende avaliar. Os diversos equipamentos testados procuraram conter amostras diversificadas, quer para os MTA de uso profissional ou doméstico, assim como para os simuladores. A avaliação dos simuladores foi realizada contra um grupo de MTAs. Foi testada a influência na medição, causada pela mudança de acessórios, ou seja, nos resultados, merecendo consideração pela perspetiva metrológica. No resumo dos testes e do estudo sobre este tema, verificou-se que esta tipologia de equipamentos pode contribuir como complemento do processo de calibração típico (estático). Não constitui por si só um método alternativo, mas permitiu estimar possíveis limites de erro e desvio padrão a partir da observação dos resultados práticos, limites esses inferiores aos processos de validação clínica. Atendendo às particularidades, estimou-se como desvio aceitável um erro mais desvio padrão de 5 + 3 mmHg para o processo de simulação. Contudo considera-se ainda importante os testes adicionais em que o simulador permite, ao verificar as medidas de segurança implementadas no equipamento e a condição dos acessórios, que como verificado afetam os resultados. No entanto nem todos os simuladores se mostram adequados a este processo pelo que a qualidade da seleção do equipamento para este fim pode eventualmente reduzir ainda mais os possíveis limites.
Resumo:
A ausência unilateral de uma artéria pulmonar é uma anomalia congénita rara. Os autores descrevem o caso de um rapaz de dois anos, sem antecedentes patológicos prévios e que é referenciado para avaliação após a detecção na telerradiografia de tórax de assimetria dos campos pulmonares com desvio do mediastino para a direita. A tomografia axial computorizada e a cintigrafia de perfusão pulmonar entretanto efectuadas, indicavam para a ausência da artéria pulmonar direita que foi comprovada no cateterismo cardíaco e em ressonância magnética. Esta é uma patologia relevante pois o seu diagnóstico precoce e a sua correcção atempada podem evitar morbilidades no futuro. Dada a idade e o facto de o doente estar de momento assintomático, optou-se por uma atitude conservadora e vigilância em ambulatório.
Resumo:
Os doentes com cardiopatias submetidos a intervenção cirúrgica com implantação de condutos entre o ventrículo direito e a artéria pulmonar (VD-AP) podem desenvolver estenose e/ou insuficiência pulmonares ao longo do tempo. Nestas situações, associadas a arritmias cardíacas, disfunção ventricular direita e morte súbita, a re-intervenção cirúrgica permanece um desafio pela complexidade, mortalidade e morbilidade significativas. A implantação percutânea de válvulas pulmonares (IPVP), recentemente desenvolvida, representa uma abordagem alternativa para estes doentes. Objectivo: Reportar a experiência inicial com a IPVP, analisando o seu impacto no manejo destes doentes. Material e Métodos: Avaliação prospectiva dos dados clínicos, ecocardiográficos, da ressonância magnética, hemodinâmicos e angiográficos dos doentes submetidos a IPVP. Resultados: Seis doentes em classe funcional igual ou superior a II com disfunção do conduto VD-AP foram submetidos a IPVP. Tinham todos evidência de insuficiência e 5/6 de estenose. O procedimento consistiu na implantação de stents não cobertos no conduto para reforçar a sua rigidez e prevenir fracturas dos stents valvulados pulmonares Melody ® (Medtronic), que foram em seguida implantados com sucesso em todos. Obteve-se uma redução da pressão ventricular direita (94±27 para 44±7mmHg), da relação entre a pressão ventricular direita e esquerda (94±27 para 44±7%), do gradiente do conduto (65±28 para 11±4mmHg) e ausência de regurgitação pulmonar. O procedimento teve uma duração mediana de 180 minutos e decorreu sem complicações major. Os doentes tiveram alta em mediana dois dias após o procedimento. Na última avaliação, em mediana 7,8 meses após o procedimento, os doentes encontramse em classe funcional I (5) ou II (1), sem evidência não invasiva de disfunção do conduto. Conclusões: Os nossos resultados acompanham a experiência actual com esta modalidade terapêutica, com excelentes resultados nestes grupo de doentes complexos. A implementação da IPVP em doentes com cardiopatia congénita que requerem re-intervenção no tracto de saída do ventrículo direito tem-se revelado uma técnica promissora, embora complexa, alternativa a mais uma intervenção cirúrgica.
Resumo:
Editorial note
Resumo:
Introduction: Entamoeba histolytica infections were investigated in residents of the Ariquemes and Monte Negro municipalities in Rondônia State, Brazil. Methods: Stool samples of 216 individuals were processed by the spontaneous sedimentation method and analyzed by microscopy for detection of the E. histolytica/E. dispar complex, followed by the immunoassay method using an enzyme-linked immunosorbent assay-based kit for the E. histolytica stool antigen. Results: E. histolytica/E. dispar cysts were present in 61% (50/82) and 44% (59/134) of the samples from Ariquemes and Monte Negro respectively, with a significant difference in the occurrence of infection between the two populations [p < 0.05; χ2 = 5.2; odds ratio = 2.0 (1.1 - 3.6)]. The E. histolytica antigen detection rate was 36.6% (30/82) for stool samples from Ariquemes, and 19.4% (26/134) for stool taken from the residents of Monte Negro. The rate of the occurrence of amoebiasis was significantly higher in the population from Ariquemes [p < 0.05; χ2 = 7.8; odds ratio = 2.4 (1.2 - 4.7)]. Discussion: Due to the high occurrence of E. histolytica infected residents diagnosed in the region and the unavailability in local clinics of a test to distinguish between the two Entamoeba species, physicians should consider treating E. histolytica/E.dispar infections. Conclusion: The results indicate that E. histolytica infection is highly endemic in the studied areas.
Resumo:
Apresenta-se a distribuição por sexos em 4150 crianças, de idade inferior a 13 anos, com cardiopatias congénitas bem definidas, estudadas num periodo de 17 anos. Globalmente a distribuição foi equilibrada, sendo 2108 do fenotipo masculino (50,8%) e 2042 do fenotipo feminino(49,2%), com um quociente Q = 1,03. Verificou-se um predomínio franco do sexo masculino para as seguintes cardiopatias: estenose aórtica valvular e subvalvular fixa (70%), coarctação da aorta(66%), transposição das grandes artérias (60%), coração univentricular (76%), atrésia da tricúspide (63%), anomalia de Ebstein (76%), sindrome do coração esquerdo hipoplásico (85%), aneis vasculares (77%) e estenose médio-ventricular direita (70%). Verificou-se um predomínio franco do sexo feminino para o canal arterial persistente (72%), os defeitos do septo aurículo-ventricular (62%,), a estenose aórtica supravalvular (71%) e a estenose pulmonar infundibular isolada (80%). Confirmou-se uma distribuição muito mais equilibrada para os casos de canal arterial persistente isolado em síndrome de rubéola congénita (56%). Salienta-se a importância de conhecer a distribuição por sexos, por esta ter valor preditivo quanto ao risco de recorrência familiar das cardiopatias congénitas.
Resumo:
Introduction:American tegumentary leishmaniasis (ATL) can be caused by Leishmania (Viannia) braziliensis complex. The evolution of ATL initially results in lesions and can develop into disseminated or diffuse forms. The genetic diversity of L. (V.) braziliensis in some endemic areas of Brazil has been poorly studied, such as in the state of São Paulo. This study analyzed the genetic diversity of L. (V.) braziliensis isolates collected from patients and dogs with LTA from the state of São Paulo.Methods:Leishmaniasis diagnosis was determined by PCR. The 132 biopsies were collected in different regions of Sao Paulo State, Brazil (36 municipalities). The genetic characterization of L. (V.) braziliensis isolates was tested by RFLP-PCR using DNA extracted from biopsies. The primer set amplified a specific region of Leishmania internal transcribed spacers of the ribosomal DNA locus.Results:Of the 132 samples, 52 (40%) were completely genotyped by RFLP-PCR (44 from human patients and eight from dogs). The results showed nine distinct patterns. The majority of the genotyped samples were from Sorocaba (30), and the others were distributed among 14 other municipalities. The first pattern was more frequent (29 samples), followed by pattern 2 (nine samples) and pattern 3 (three samples). Patterns 4, 6, 7, 8 and 9 were composed of two samples each and pattern 5 of one sample.Conclusion:These results suggest that polymorphic strains of L. (V.) braziliensis circulate in the state of São Paulo. These data agree with studies from other regions of Brazil, showing great variability among the natural populations of endemic foci.
Resumo:
Manipulator systems are rather complex and highly nonlinear which makes difficult their analysis and control. Classic system theory is veil known, however it is inadequate in the presence of strong nonlinear dynamics. Nonlinear controllers produce good results [1] and work has been done e. g. relating the manipulator nonlinear dynamics with frequency response [2–5]. Nevertheless, given the complexity of the problem, systematic methods which permit to draw conclusions about stability, imperfect modelling effects, compensation requirements, etc. are still lacking. In section 2 we start by analysing the variation of the poles and zeros of the descriptive transfer functions of a robot manipulator in order to motivate the development of more robust (and computationally efficient) control algorithms. Based on this analysis a new multirate controller which is an improvement of the well known “computed torque controller” [6] is announced in section 3. Some research in this area was done by Neuman [7,8] showing tbat better robustness is possible if the basic controller structure is modified. The present study stems from those ideas, and attempts to give a systematic treatment, which results in easy to use standard engineering tools. Finally, in section 4 conclusions are presented.
Resumo:
Despite public health campaigns and epidemiological surveillance activities, Chagas disease remains a major health problem in Latin America. According to data from the World Health Organization, there are approximately 7-8 million people infected with Trypanosoma cruzi worldwide, a large percentage of which in Latin America. This study aims to examine the serological profile of blood donors in blood banks of Hemominas hematology center, in the town of Ituiutaba, Minas Gerais State, Brazil. The study sample consisted of 53,941 blood donors, which were grouped according to gender and age. Sample collections were performed from January 1991 to December 2011, and 277 donors (0.5%) were considered serologically ineligible due to Chagas disease. Analysis of data showed no significant difference between genders. As for age, the highest proportion of ineligible donors was from 40 to 49 years (30%), and there was a positive correlation between increasing age and the percentage of patients seropositive for Chagas disease. Therefore, adopting strategies that allow the safe identification of donors with positive serology for Chagas disease is essential to reduce or eliminate indeterminate serological results.
Resumo:
Neurocardiogenic syncope (NCS) is a common clinical entity resulting from an excessive reflex autonomic response, particularly during orthostatism. Treatment options are controversial and of limited effectiveness. Tilt training (TT) is a promising option to treat these patients. However, its mechanism of action and clinical impact remain unclear. OBJECTIVE: To characterize hemodynamic and autonomic responses during a TT program in patients with NCS refractory to conventional measures. METHODS: We studied 28 patients (50% male, mean age 41±14 years) without structural heart disease, with NCS documented by tilt testing. The TT program included 9 tilt sessions (3 times a week, 30 min) (60° - 6 sessions, 70° - 3 sessions), under ECG and blood pressure monitoring combined with home orthostatic self-training and 10° head-up during sleep. Systolic volume, cardiac output, total peripheral resistance, baroreflex sensitivity and heart-rate variability were computed. Patients were reassessed at 1 month and every 6 months for a maximum of 36 months (24±12 months). RESULTS: Over the course of the TT program there was a significant increase in total peripheral resistance (1485±225 vs. 1591±187 dyn·s·cm(-5), p<0.05), with a decrease in standard deviation (206±60 vs. 150±42, p<0.05). During follow-up, syncope recurred in five patients (19%), with a significant reduction in the number of episodes (4.0±3.2/patient in the 12 months before TT vs. 1.4±0.8/patient post-TT, p<0.05). CONCLUSION: In refractory NCS, TT may be an effective therapeutic option, with long-term benefits. These results appear to be due to an increase in vasoconstrictor reserve combined with a reduction in its variance.
Resumo:
Dissertação para obtenção do Grau de Doutor em Informática
Resumo:
Os autores apresentam resultados da prevalência de enteroparasitoses na população urbana do município de São Tomé, Rio Grande do Norte, obtidos no período de 9 a 27 de julho de 1969, empregando o método de Hoffman, Pons e Janer, através de exames realizados em 550 amostras de fezes e registrando-se 495 positivadas para as diversas parasitoses intestinais, correpondendo a uma prevalência de 90%, relacionada com fatores do meio ambiente. As prevalências foram as seguintes: E. histolytica, 39,2%; E. coli, 59,8%; G. lamblia, 12,9%; A. lumbricoides, 23,8%; T. trichiurus 9,2%; Ancylostomydae, 7,8%; H. nana, 1,2%; E. vermicularis, 2,9%.
Resumo:
Introdução: Os acidentes constituem uma importante causa de morbimortalidade infantil e de recurso ao serviço de urgência pediátrica. A nível nacional conhecem-se apenas alguns dados epidemiológicos. Métodos: Estudo observacional transversal com análise da coorte das crianças observadas no serviço de urgência pediátrica de um hospital nível II por motivo de acidente, durante um período de nove meses, com dados obtidos através de um inquérito e submetidos a análise estatística. Resultados: Das 22502 admissões de crianças até aos 14 anos registadas, 1746 (7,8%) foram por acidentes. A maioria era do sexo masculino e tinha mais de 5 anos. Os acidentes ocorreram maioritariamente no exterior da escola (29,1%) e interior de casa (25%), predominando a queda como tipo de acidente (55,5%) e a contusão como mecanismo de lesão (54,2%). A maioria das crianças (77,3%) foi submetida a exames complementares de diagnóstico destacando-se os radiológicos. Os diagnósticos mais frequentes foram os traumatismos superficiais (47,9%) e os ferimentos (24,8%). Em 6,6% (115) dos casos os acidentes foram considerados graves. Estas admissões por acidentes associaram-se a uma despesa imediata estimada de 124 mil euros. Discussão: A frequência elevada e o local de ocorrência dos acidentes coincidiram com a literatura. Apesar do predomínio das lesões minor superficiais (47,9%) verificou-se um número significativo de crianças com necessidade de cuidados hospitalares. Não foram registados óbitos. Os autores concluem que os acidentes em crianças foram um motivo frequente de ida ao serviço de urgência pediátrica com importante consumo de recursos. A sensibilização dos cuidadores é essencial na prevenção dos acidentes.