853 resultados para 24 hour measurement


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The fracture toughness and interfacial adhesion properties of a coating on its substrate are considered to be crucial intrinsic parameters determining performance and reliability of coating-substrate system. In this work, the fracture toughness and interfacial shear strength of a hard and brittle Cr coating on a normal medium carbon steel substrate were investigated by means of a tensile test. The normal medium carbon steel substrate electroplated with a hard and brittle Cr coating was quasi-statically stretched to induce an array of parallel cracks in the coating. An optical microscope was used to observe the cracking of the coating and the interfacial decohesion between the coating and the substrate during the loading. It was found that the cracking of the coating initiated at critical strain, and then the number of the cracks of the coating per unit axial distance increased with the increase in the tensile strain. At another critical strain, the number of the cracks of the coating became saturated, i.e. the number of cracks per unit axial distance became a constant after this critical strain. Based on the experiment result, the fracture toughness of the brittle coating can be determined using a mechanical model. Interestingly, even when the whole specimen fractured completely under an extreme strain of the substrate, the interfacial decohesion or buckling of the coating on its substrate was completely absent. The test result is different from that appeared in the literature though the identical test method and the brittle coating/ductile metal substrate system are taken. It was found that this difference can be attributed to an important mechanism that the Cr coating on the steel substrate has a good adhesion, and the ultimate interfacial shear strength between the Cr coating and the steel substrate has exceeded the maximum shear flow strength level of the steel substrate. This result also indicates that the maximum shear flow strength level of the ductile steel substrate can be only taken as a lower bound estimate on the ultimate shear strength of the interface. This estimation of the ultimate interfacial shear strength is consistent with the theoretical analysis and prediction presented in the literature.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fish muscle as food is to be seen as highly perishable. In unfrozen fish, freshness is considered the most important quality attribute. It is well known that there are several biochemical changes that can affect dramatically the texture of fish muscle. Immediately after death the fish texture is soft and elastic. In connection with rigor mortis the fish texture changes markedly. It becomes harder during rigor and after its resolution it becomes softer. This softness increases due to proteolysis during further storage at refrigerated conditions. Texture is a very important indicator for evaluating the quality of fish. Barroso et al. (1997) have recently reviewed mechanical methods in use for texture measurements on fresh fish. Further reviews on texture measurement performed on fish muscle were recently published underlining the importance of texture as quality attribute (Hyldig et al 2001, Coppes et al. 2002). The position along the fish can influence the results and was investigated by several authors (Sigurgis-ladottir et. al. 1999). Different methods have been compared for their ability to differentiate between recently killed salmon and salmon stored on ice for up to 24 days (Veland et al. 1999).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

As the feature size decreases, degradation of image quality caused by wavefront aberrations of projection optics in lithographic tools has become a serious problem in the low-k1 process. We propose a novel measurement technique for in situ characterizing aberrations of projection optics in lithographic tools. Considering the impact of the partial coherence illumination, we introduce a novel algorithm that accurately describes the pattern displacement and focus shift induced by aberrations. Employing the algorithm, the measurement condition is extended from three-beam interference to two-, three-, and hybrid-beam interferences. The experiments are performed to measure the aberrations of projection optics in an ArF scanner. (C) 2006 Optical Society of America.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this paper, we propose a novel method for measuring the coma aberrations of lithographic projection optics based on relative image displacements at multiple illumination settings. The measurement accuracy of coma can be improved because the phase-shifting gratings are more sensitive to the aberrations than the binary gratings used in the TAMIS technique, and the impact of distortion on displacements of aerial image can be eliminated when the relative image displacements are measured. The PROLITH simulation results show that, the measurement accuracy of coma increases by more than 25% under conventional illumination, and the measurement accuracy of primary coma increases by more than 20% under annular illumination, compared with the TAMIS technique. (c) 2007 Optical Society of America.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The first aim of this research was to identify fatty acids, amino acids composition of Thunnus tonggol roe and their changes during cold storage (-18'C). The second aim was to determine the changes of moisture, protein, fat and ash contents of the roe during one year cold storage (-18'C). 60 samples of longtail tuna (Thunnus tonggol) ovaries were randomly collected form Bandar-e-Abbas landings. The samples were frozen at-30'C and kept in cold store at -18'C for one year. According to a time table, the samples were examined for identification of fatty acids, amino acids, moisture, protein, fat, ash, peroxide and T.V.N. and their changes were evaluated during this time. The results showed that 26 fatty acids were identified. The unsaturated fatty acids (UFA) and saturated fatty acids (SFA) were 62.33 and 37.6%, respectively, in fresh roe. So that, DHA (C22:6) and oleic acid (C18:1) had high amounts (24.79 and 21.88%) among the UFA and palmitic acid (C16:0) was the most content (22.75%) among the SFA. The PUFA/SFA was 0.91. Also, 17 amino acids were identified that essential amino acids (EAA) and nonessential amino acids (NE) were 10478 and 7562 mg/100g, respectively, and E/NE was 1.38. Among the EAA and NE, lysine (2110mg/100g) and aspartic acid (1924 mg/100g) were the most contents. Also, results showed that moisture, ash, protein and fat contents were 72.74, 1.8, 19.88 and 4.53%, respectively, in fresh roe. The effects of freezing and cold storage on the roes showed that UFA and SFA contents have reached to 49.83 and 48.07%, respectively, at the end of cold storage. It indicated that these compounds change to each other during frozen storage. Also, n-3 and n-6 series of fatty acids were 32.75 and 1.61% in fresh roe. But their contents decreased to 22.96 and 1.25% at the end of period. Among the fatty acids, 22:6 and C16:0 had the most changes. The changes of fatty acids were significantly at 95% level except for C15:1, C18:3(n-3) and C20:4(n-6). All of the amino acids decreased in frozen storage and their changes were significantly (P<0.05). EAA was 7818 mg/100g and E/NE was 1.27 at the end of storage period. Among the amino acids, leucine and lysine had the most changes. Moisture, ash, protein and fat contents were 70.13, 1.82, 19.4 and 6.51%, respectively, at the end of storage period. The peroxide value and T.V.N. increased during storage. So that, their contents have reached to 5.86 mg/kg and 26.37 mg/100 g, respectively, at the end of frozen storage. The best shelf life of Thunnus tonggol roe was 6 or 7 months, because of lipid oxidation and increasing of peroxide.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Mode gain spectrum is measured by the Fourier series expansion method for InAs/GaAs quantum-dot (QD) lasers with seven stacks of QDs at different injection currents. Gain spectra with distinctive peaks are observed at the short and long wavelengths of about 1210 nm and 1300 nm. For a QD laser with the cavity length of 1060 mu m, the peak gain of the long wavelength first increases slowly or even decreases with the injection current as the peak gain of the short wavelength increases quickly, and finally increases quickly before approaching the saturated values as the injection current further increases.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

An accurate technique for measuring the frequency response of semiconductor laser diode chips is proposed and experimentally demonstrated. The effects of test jig parasites can be completely removed in the measurement by a new calibration method. In theory, the measuring range of the measurement system is only determined by the measuring range of the instruments network analyzer and photo detector. Diodes' bandwidth of 7.5GHz and 10GHz is measured. The results reveal that the method is feasible and comparing with other method, it is more precise andeasier to use.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A fitting process is used to measure the cavity loss and the quasi-Fermi-level separation for Fabry- Perot semiconductor lasers. From the amplified spontaneous emission (ASE) spectrum, the gain spectrum and single-pass ASE obtained by the Cassidy method are applied in the fitting process. For a 1550nm quantum well InGaAsP ridge waveguide laser, the cavity loss of about ~24cm~(-1) is obtained.