913 resultados para total accruals
Resumo:
This article is a brief introduction to the total solar eclipse Wed 14 November 2012 in north Queensland that will be seen in a narrow strip of land just 140 km wide in the vicinity of Cairns.
Resumo:
Bleeding related wound complications cause significant morbidity in lower limb arthroplasty surgery. Patients who require therapeutic anticoagulation in the peri operative period are potentially at higher risk of these complications. This is a retrospective case control study reviewing all primary total hip replacements performed in a single center over a five year period and comparing outcomes of the patients on warfarin with a double-matched control group of patients not on warfarin. The warfarin group had significantly higher risk of deep joint infection (9% vs 2.2%), haematoma/ wound ooze (28% vs 4%) and superficial infection (13.5% vs 2.2%). Managing the total hip arthroplasty patient with therapeutic anticoagulation is a balance between the risk of thromboembolic disease and bleeding related complications. Improved understanding of this risk will better allow the patient to make an informed decision regarding their elective arthroplasty surgery.
Resumo:
This report discusses the geologic framework and petroleum geology used to assess undiscovered petroleum resources in the Bohaiwan basin province for the 2000 World Energy Assessment Project of the U.S. Geological Survey. The Bohaiwan basin in northeastern China is the largest petroleum-producing region in China. Two total petroleum systems have been identified in the basin. The first, the Shahejie–Shahejie/Guantao/Wumishan Total Petroleum System, involves oil and gas generated from mature pods of lacustrine source rock that are associated with six major rift-controlled subbasins. Two assessment units are defined in this total petroleum system: (1) a Tertiary lacustrine assessment unit consisting of sandstone reservoirs interbedded with lacustrine shale source rocks, and (2) a pre-Tertiary buried hills assessment unit consisting of carbonate reservoirs that are overlain unconformably by Tertiary lacustrine shale source rocks. The second total petroleum system identified in the Bohaiwan basin is the Carboniferous/Permian Coal–Paleozoic Total Petroleum System, a hypothetical total petroleum system involving natural gas generated from multiple pods of thermally mature coal beds. Low-permeability Permian sandstones and possibly Carboniferous coal beds are the reservoir rocks. Most of the natural gas is inferred to be trapped in continuous accumulations near the center of the subbasins. This total petroleum system is largely unexplored and has good potential for undiscovered gas accumulations. One assessment unit, coal-sourced gas, is defined in this total petroleum system.
Resumo:
Total Dik! is a collaborative project between the Queensland University of Technology (QUT) and Queensland Theatre Company (QTC). Total Dik! explores transmedia storytelling in live performance from concept development to delivery and builds on works, By the Way, Meet Vera Stark, (Forrester2012), Hotel Modern’s Kamp (2005) and God’s Beard (2012) that use visual art, puppetry, music and film. The project’s first iteration enabled an interrogation of the integration of media-rich elements with live performers in a theatrical environment. Performative transmedia storytelling draws on the tenets of convergent media theory developed by Jenkins (2007, 2012), Dena (2010) and Philips (2012). This exploratory work, juxtaposing transmedia storytelling techniques with live performance, draws on Samuel Becket’s challenges to theatre orthodoxy, and touches on Brechtian notions of alienation through ‘sleight-of-hand’ or processual unpacking and deconstruction during performance. Total Dik! blends a convergence of technologies, models, green screen capture, and live dimensions of performance in one narrative allowing the work’s creators to test new combinations of transmedia storytelling techniques on a traditional performance platform.
Resumo:
Background: Surgical site infection (SSI) is associated with substantial costs for health services, reduced quality of life, and functional outcomes. The aim of this study was to evaluate the cost-effectiveness of strategies claiming to reduce the risk of SSI in hip arthroplasty in Australia. Methods: Baseline use of antibiotic prophylaxis (AP) was compared with no antibiotic prophylaxis (no AP), antibiotic-impregnated cement (AP þ ABC), and laminar air operating rooms (AP þ LOR). A Markov model was used to simulate long-term health and cost outcomes of a hypothetical cohort of 30,000 total hip arthroplasty patients from a health services perspective. Model parameters were informed by the best available evidence. Uncertainty was explored in probabilistic sensitivity and scenario analyses. Results: Stopping the routine use of AP resulted in over Australian dollars (AUD) $1.5 million extra costs and a loss of 163 quality-adjusted life years (QALYs). Using antibiotic cement in addition to AP (AP þ ABC)generated an extra 32 QALYs while saving over AUD $123,000. The use of laminar air operating rooms combined with routine AP (AP þ LOR) resulted in an AUD $4.59 million cost increase and 127 QALYs lost compared with the baseline comparator. Conclusion: Preventing deep SSI with antibiotic prophylaxis and antibiotic-impregnated cement has shown to improve health outcomes among hospitalized patients, save lives, and enhance resource allocation. Based on this evidence, the use of laminar air operating rooms is not recommended.
Resumo:
Between 1995 and 2003, 129 cemented primary THRs were performed using full acetabular impaction grafting to reconstruct acetabular deficiencies. These were classified as cavitary in 74 and segmental in 55 hips. Eighty-one patients were reviewed at mean 9.1 (6.2-14.3) years post-operatively. There were seven acetabular component revisions due to aseptic loosening, and a further 11 cases that had migrated >5mm or tilted >5° on radiological review - ten of which reported no symptoms. Kaplan-Meier analysis of revisions for aseptic loosening demonstrates 100% survival at nine years for cavitary defects compared to 82.6% for segmental defects. Our results suggest that the medium-term survival of this technique is excellent when used for purely cavitary defects but less predictable when used with large rim meshes in segmental defects.
Resumo:
La varianza estadística del costo total de un proyecto usualmente se estima por medio de la simulación de Monte Carlo, bajo el supuesto de que los acercamientos analíticos son demasiado complicados. Este artículo analiza este supuesto y muestra que, contrario a lo esperado, la solución analítica es relativamente directa. También se muestra que el coeficiente de variación no se ve afectado por el tamaño (área superficial) del proyecto cuando se usan los costos de los componentes estandarizados. Se provee un caso de estudio en el cual se analizan los costos reales de los componentes para obtener la varianza del costo total requerida. Los resultados confirman trabajos previos al mostrar que la aproximación del segundo momento (varianza) bajo el supuesto de independencia subestima considerablemente el valor exacto. El análisis continua examinando los efectos del juicio profesional y con los datos simulados utilizados, la aproximación resulta razonablemente exacta - el juicio profesional absorbe la mayor parte de las intercorrelaciones involucradas. También se da un ejemplo en el cual las cantidades de los componentes unitarios son valoradas por sus costos unitarios promedios y muestra, una vez más, que la aproximación es cercana al valor real. Finalmente, el trabajo se extiende mostrando cómo obtener, para cada proyecto, las varianzas exactas del costo total.
Resumo:
In Australia and increasingly worldwide, methamphetamine is one of the most commonly seized drugs analysed by forensic chemists. The current well-established GC/MS methods used to identify and quantify methamphetamine are lengthy, expensive processes, but often rapid analysis is requested by undercover police leading to an interest in developing this new analytical technique. Ninety six illicit drug seizures containing methamphetamine (0.1% - 78.6%) were analysed using Fourier Transform Infrared Spectroscopy with an Attenuated Total Reflectance attachment and Chemometrics. Two Partial Least Squares models were developed, one using the principal Infrared Spectroscopy peaks of methamphetamine and the other a Hierarchical Partial Least Squares model. Both of these models were refined to choose the variables that were most closely associated with the methamphetamine % vector. Both of the models were excellent, with the principal peaks in the Partial Least Squares model having Root Mean Square Error of Prediction 3.8, R2 0.9779 and lower limit of quantification 7% methamphetamine. The Hierarchical Partial Least Squares model had lower limit of quantification 0.3% methamphetamine, Root Mean Square Error of Prediction 5.2 and R2 0.9637. Such models offer rapid and effective methods for screening illicit drug samples to determine the percentage of methamphetamine they contain.
Resumo:
There has been much discussion and controversy in the media recently regarding metal toxicity following large head metal on metal (MoM) total hip replacement (THR). Patients have been reported as having hugely elevated levels of metal ions with, at times, devastating systemic, neurolgical and/or orthopaedic sequelae. However, no direct correlation between metal ion level and severity of metallosis has yet been defined. Normative levels of metal ions in well functioning, non Cobalt-Chrome hips have also not been defined to date. The Exeter total hip replacement contains no Cobalt-Chrome (Co-Cr) as it is made entirely from stainless steel. However, small levels of these metals may be present in the modular head of the prosthesis, and their effect on metal ion levels in the well functioning patient has not been investigated. We proposed to define the “normal” levels of metal ions detected by blood test in 20 well functioning patients at a minimum 1 year post primary Exeter total hip replacement, where the patient had had only one joint replaced. Presently, accepted normal levels of blood Chromium are 10–100 nmol/L and plasma Cobalt are 0–20 nmol/L. The UK Modern Humanities Research Association (MHRA) has suggested that levels of either Cobalt or Chromium above 7 ppb (equivalent to 135 nmol/L for Chromium and 120 nmol/L for Cobalt) may be significant. Below this level it is indicated that significant soft tissue reaction and tissue damage is less likely and the risk of implant failure is reduced. Hips were a mixture of cemented and hybrid procedures performed by two experienced orthopaedic consultants. Seventy percent were female, with a mixture of head sizes used. In our cohort, there were no cases where the blood Chromium levels were above the normal range, and in more than 70% of cases, levels were below recordable levels. There were also no cases of elevated plasma Cobalt levels, and in 35% of cases, levels were negligible. We conclude that the implantation with an Exeter total hip replacement does not lead to elevation of blood metal ion levels.
Resumo:
BACKGROUND: Numerous strategies are available to prevent surgical site infections in hip arthroplasty, but there is no consensus on which might be the best. This study examined infection prevention strategies currently recommended for patients undergoing hip arthroplasty. METHODS: Four clinical guidelines on infection prevention/orthopedics were reviewed. Infection control practitioners, infectious disease physicians, and orthopedic surgeons were consulted through structured interviews and an online survey. Strategies were classified as "highly important" if they were recommended by at least one guideline and ranked as significantly or critically important by >/=75% of the experts. RESULTS: The guideline review yielded 28 infection prevention measures, with 7 identified by experts as being highly important in this context: antibiotic prophylaxis, antiseptic skin preparation of patients, hand/forearm antisepsis by surgical staff, sterile gowns/surgical attire, ultraclean/laminar air operating theatres, antibiotic-impregnated cement, and surveillance. Controversial measures included antibiotic-impregnated cement and, considering recent literature, laminar air operating theatres. CONCLUSIONS: Some of these measures may already be accepted as routine clinical practice, whereas others are controversial. Whether these practices should be continued for this patient group will be informed by modeling the cost-effectiveness of infection prevention strategies. This will allow predictions of long-term health and cost outcomes and thus inform decisions on how to best use scarce health care resources for infection control.
Resumo:
Background: Achieving soft tissue balance is an operative goal in total knee arthroplasty. This randomised, prospective study compared computer navigation to conventional techniques in achieving soft tissue balance. Methods: Forty one consecutive knee arthroplasties were randomised to either a non-navigated or navigated group. In the non-navigated group, balancing was carried out using surgeon judgement. In the navigated group, balancing was carried out using navigation software. In both groups, the navigation software was used as a measuring tool. Results: Balancing of the mediolateral extension gap was superior in the navigation group (p=0.001). No significant difference was found between the two groups in balancing the mediolateral flexion gap or in achieving equal flexion and extension gaps. Conclusions: Computer navigation offered little advantage over experienced surgeon judgement in achieving soft tissue balance in knee replacement. However, the method employed in the navigated group did provide a reproducible and objective assessment of flexion and extension gaps and may therefore benefit surgeons in training.
Resumo:
The surface area of inhaled particles deposited in the alveolar region, as reported by the TSI nanoparticle surface area monitor (NSAM), was compared with the corresponding value estimated by a TSI scanning mobility particle sizer (SMPS) for a range of environmentally relevant aerosols, including petrol emissions, ETS, laser printer emissions, cooking emissions and ambient aerosols. The SMPS values were based on a mobility size distribution assuming spherical particles using the appropriate size-dependent alveolar-deposition factors provided by the ICRP. In most cases, the two instruments showed good linear agreement. With petrol emissions and ETS, the linearity extended to over 103 μm2 cm-3. With printer emissions, there was good linearity up to about 300 μm2 cm-3 while the NSAM increasingly overestimated the surface area at higher concentrations. The presence of a nucleation event in ambient air caused the NSAM to over-estimate the surface area by a factor of 2. We summarize these results and conclude that the maximum number concentration up to which the NSAM is accurate clearly depends on the type of aerosol being sampled and provide guidance for the use of the instrument.
Resumo:
BACKGROUND/OBJECTIVES: Recent work suggests that macronutrients are pro-inflammatory and promote oxidative stress. Reports of postprandial regulation of total adiponectin have been mixed, and there is limited information regarding postprandial changes in high molecular weight (HMW) adiponectin. The aim of this study was to assess the effect of a standardised high-fat meal on metabolic variables, adiponectin (total and HMW), and markers of inflammation and oxidative stress in: (i) lean, (ii) obese non-diabetic and (iii) men with type 2 diabetes mellitus (T2DM). SUBJECTS/METHODS: Male subjects: lean (n=10), obese (n=10) and T2DM (n=10) were studied for 6 h following both a high-fat meal and water control. Metabolic variables (glucose, insulin, triglycerides), inflammatory markers (interleukin-6 (IL6), tumour necrosis factor (TNF)α, high-sensitivity C-reactive protein (hsCRP), nuclear factor (NF)κB expression in peripheral blood mononuclear cells (p65)), indicators of oxidative stress (oxidised low density lipoprotein (oxLDL), protein carbonyl) and adiponectin (total and HMW) were measured. RESULTS: No significant changes in TNFα, p65, oxLDL or protein carbonyl concentrations were observed. Overall, postprandial IL6 decreased in subjects with T2DM but increased in lean subjects, whereas hsCRP decreased in the lean cohort and increased in obese subjects. There was no overall postprandial change in total or HMW adiponectin in any group. Total adiponectin concentrations changed over time following the water control, and the response was significantly different in lean subjects compared with subjects with T2DM (P=0.04). CONCLUSIONS: No consistent significant postprandial inflammation, oxidative stress or regulation of adiponectin was observed in this study. Findings from the water control suggest differential basal regulation of total adiponectin in T2DM compared with lean controls.
Resumo:
Patients presenting for knee replacement on warfarin for medical reasons often require higher levels of anticoagulation peri-operatively than primary thromboprophylaxis and may require bridging therapy with heparin. We performed a retrospective case control study on 149 consecutive primary knee arthroplasty patients to investigate whether anti-coagulation affected short-term outcomes. Specific outcome measures indicated significant increases in prolonged wound drainage (26.8% of cases vs 7.3% of controls, p<0.001); superficial infection (16.8% vs 3.3%, p<0.001); deep infection (6.0% vs 0%, p<0.001); return-to-theatre for washout (4.7% vs 0.7%, p=0.004); and revision (4.7% vs 0.3%, p=0.001). Management of patients on long-term warfarin therapy following TKR is particularly challenging, as the surgeon must balance risk of thromboembolism against post-operative complications on an individual patient basis in order to optimise outcomes.
Resumo:
Successful anatomic fitting of a total artificial heart (TAH) is vital to achieve optimal pump hemodynamics after device implantation. Although many anatomic fitting studies have been completed in humans prior to clinical trials, few reports exist that detail the experience in animals for in vivo device evaluation. Optimal hemodynamics are crucial throughout the in vivo phase to direct design iterations and ultimately validate device performance prior to pivotal human trials. In vivo evaluation in a sheep model allows a realistically sized representation of a smaller patient, for which smaller third-generation TAHs have the potential to treat. Our study aimed to assess the anatomic fit of a single device rotary TAH in sheep prior to animal trials and to use the data to develop a threedimensional, computer-aided design (CAD)-operated anatomic fitting tool for future TAH development. Following excision of the native ventricles above the atrio-ventricular groove, a prototype TAH was inserted within the chest cavity of six sheep (28–40 kg).Adjustable rods representing inlet and outlet conduits were oriented toward the center of each atrial chamber and the great vessels, with conduit lengths and angles recorded for future analysis. A threedimensional, CAD-operated anatomic fitting tool was then developed, based on the results of this study, and used to determine the inflow and outflow conduit orientation of the TAH. The mean diameters of the sheep left atrium, right atrium, aorta, and pulmonary artery were 39, 33, 12, and 11 mm, respectively. The center-to-center distance and outer-edge-to-outer-edge distance between the atria, found to be 39 ± 9 mm and 72 ± 17 mm in this study, were identified as the most critical geometries for successful TAH connection. This geometric constraint restricts the maximum separation allowable between left and right inlet ports of a TAH to ensure successful alignment within the available atrial circumference.