161 resultados para thermography
Resumo:
Photovoltaic (PV) solar power generation is proven to be effective and sustainable but is currently hampered by relatively high costs and low conversion efficiency. This paper addresses both issues by presenting a low-cost and efficient temperature distribution analysis for identifying PV module mismatch faults by thermography. Mismatch faults reduce the power output and cause potential damage to PV cells. This paper first defines three fault categories in terms of fault levels, which lead to different terminal characteristics of the PV modules. The investigation of three faults is also conducted analytically and experimentally, and maintenance suggestions are also provided for different fault types. The proposed methodology is developed to combine the electrical and thermal characteristics of PV cells subjected to different fault mechanisms through simulation and experimental tests. Furthermore, the fault diagnosis method can be incorporated into the maximum power point tracking schemes to shift the operating point of the PV string. The developed technology has improved over the existing ones in locating the faulty cell by a thermal camera, providing a remedial measure, and maximizing the power output under faulty conditions.
Resumo:
The purpose of this project was to evaluate the location and quantities of debonding in selected portland cement concrete (PCC) overlays. The project entailed an infrared thermographic survey and a ground penetrating radar survey of the PCC overlays to locate areas of debonding between the overlays and the original pavement. An infrared scanner is capable of locating these areas because of the temperature differential which is established between bonded and debonded areas under certain environmental conditions. A conventional video inspection of the top surface of the pavement was also completed in conjunction with the infrared thermographic survey to record the visual condition of the pavement surface. The ground penetrating radar system is capable of locating areas of debonding by detecting return wave forms generated by changes in the dielectric properties at the PCC overlay original pavement interface. This report consists of two parts; a text and a set of plan sheets. The text summarizes the procedures, analyses and conclusions of the investigation. The plan sheets locate specific areas of debonding, as identified through field observations.
Resumo:
With the increasing importance given to building rehabilitation comes the need to create simple, fast and non-destructive testing methods (NDT) to identify problems and for anomaly diagnosis. Ceramic tiles are one of the most typical kinds of exterior wall cladding in several countries; the earliest known examples are Egyptian dating from 4000 BC. This type of building facade coating, though being quite often used in due to its aesthetic and architectural characteristics, is one of the most complex that can be applied given the several parts from which it is composed; hence, it is also one of the most difficult to correctly diagnose with expeditious methods. The detachment of ceramic wall tiles is probably the most common and difficult to identify anomaly associated with this kind of cladding and it is also definitely the one that can compromise security the most. Thus, it is necessary to study a process of inspection more efficient and economic than the currently used which often consist in semi-destructive methods (the most common is the pull off test), that can only be used in a small part of the building at a time, allowing some assumptions of what can the rest of the cladding be like. Infrared thermography (IRT) is a NDT with a wide variety of applications in building inspection that is becoming commonly used to identify anomalies related with thermal variations in the inspected surfaces. Few authors have studied the application of IRT in anomalies associated with ceramic claddings claiming that the presence of air or water beneath the superficial layer will influence the heat transfer in a way that can be detected in both a qualitative and a quantitative way by the thermal camera, providing information about the state of the wall in a much broad area per trial than other methods commonly used nowadays. This article intends to present a review of the state of art of this NDT and its potentiality in becoming a more efficient way to diagnose anomalies in ceramic wall claddings.
Resumo:
O presente trabalho visou avaliar as temperaturas superficiais de diferentes regiões anatômicas de búfalos ao longo do tempo, por meio da termografia infravermelha, e correlacioná-las a índices bioclimatológicos de conforto térmico. O ensaio foi realizado em região de clima tropical úmido (Afi de Köppen), de abril a agosto. Dez touros (n=10) foram avaliados a cada 25 dias (manhã: seis-nove horas; tarde: 12-15h), quanto à frequência respiratória (FR), temperatura retal (TR) e imagens termográficas da órbita ocular (ORB), flanco direito (FLd), flanco esquerdo (FLe) e escroto (ESC). Os dados climatológicos foram ininterruptamente monitorados, e calculados o índice de temperatura e umidade (ITU) e o índice de conforto de Benezra (ICB). O ITU foi ?78, com diferença entre turnos (P<0,05). Já o ICB variou de 1,96 a 2,25 e apresentou diferenças ao longo dos meses e entre turnos (P<0,05). As temperaturas observadas foram de TR=38,2±0,5ºC, ORB=36,1±0,8ºC, FLd=33,5±2,5ºC, FLe=35,4±1,7ºC e ESC=33,3±1,1ºC, as quais variaram significativamente ao longo dos meses e entre turnos (P<0,05). O ITU apresentou correlações positivas com ORB (0,72), FLd (0,77), FLe (0,75) e ESC (0,41) (P<0,0001). A temperatura máxima de ORB apresentou a maior correlação com a TR (0,58; P<0,0001). Portanto, as temperaturas superficiais dos animais sofrem interferências das variações climáticas e se elevam ao longo do dia, devido à variação nos índices de conforto térmico; a temperatura máxima de ORB foi o parâmetro mais condicionado à temperatura retal. Também, as oscilações de temperatura de superfície de ORB, FLd, FLe e ESC podem ser aferidas em bubalinos com o uso da termografia infravermelha, de modo preciso e não invasivo.
Resumo:
O presente trabalho visou avaliar as temperaturas superficiais de diferentes regiões anatômicas de búfalos ao longo do tempo, por meio da termografia infravermelha, e correlacioná-las a índices bioclimatológicos de conforto térmico. O ensaio foi realizado em região de clima tropical úmido (Afi de Köppen), de abril a agosto. Dez touros (n=10) foram avaliados a cada 25 dias (manhã: seis-nove horas; tarde: 12-15h), quanto à frequência respiratória (FR), temperatura retal (TR) e imagens termográficas da órbita ocular (ORB), flanco direito (FLd), flanco esquerdo (FLe) e escroto (ESC). Os dados climatológicos foram ininterruptamente monitorados, e calculados o índice de temperatura e umidade (ITU) e o índice de conforto de Benezra (ICB). O ITU foi ?78, com diferença entre turnos (P<0,05). Já o ICB variou de 1,96 a 2,25 e apresentou diferenças ao longo dos meses e entre turnos (P<0,05). As temperaturas observadas foram de TR=38,2±0,5ºC, ORB=36,1±0,8ºC, FLd=33,5±2,5ºC, FLe=35,4±1,7ºC e ESC=33,3±1,1ºC, as quais variaram significativamente ao longo dos meses e entre turnos (P<0,05). O ITU apresentou correlações positivas com ORB (0,72), FLd (0,77), FLe (0,75) e ESC (0,41) (P<0,0001). A temperatura máxima de ORB apresentou a maior correlação com a TR (0,58; P<0,0001). Portanto, as temperaturas superficiais dos animais sofrem interferências das variações climáticas e se elevam ao longo do dia, devido à variação nos índices de conforto térmico; a temperatura máxima de ORB foi o parâmetro mais condicionado à temperatura retal. Também, as oscilações de temperatura de superfície de ORB, FLd, FLe e ESC podem ser aferidas em bubalinos com o uso da termografia infravermelha, de modo preciso e não invasivo.
Resumo:
In this work, we describe the growth of NaCl crystals by evaporating droplets of aqueous solution while monitoring them with infrared thermography. Over the course of the evaporation experiments, variations in the recorded signal were observed and interpreted as being the result of evaporation and crystallisation. In particular, we observed sharp and transient decreases in the thermosignal during the later stages of high-concentration drop evaporation. The number of such events per experiment, referred to as “pop-cold events”, varied from 1 to over 100 and had durations from 1 to 15 s. These events are interpreted as a consequence from the top-supplied creeping (TSC) of the solution feeding the growth of efflorescence-like crystals. This phenomenon occurred when the solution was no longer macroscopically visible. In this case, efflorescence-like crystals with a spherulite shape grew around previously formed cubic crystals. Other crystal morphologies were also observed but were likely fed by mass diffusion or bottom-supplied creeping (BSC) and were not associated with “pop-cold events”; these morphologies included the cubic crystals at the centre, ring-shaped at the edge of droplets and fan-shaped crystals. After complete evaporation, an analysis of the numbers and sizes of the different types of crystals was performed using image processing. Clear differences in their sizes and distribution were observed in relation to the salt concentration. Infrared thermography permitted a level of quantification that previously was only possible using other techniques. As example, the intermittent efflorescence growth process was clearly observed and measured for the first time using infrared thermography.
Resumo:
To examine the reliability of infrared thermography (IRT) in wheelchair users (WCUs), as a noninvasive and risk-free technique to detect the natural thermal radiation emitted by human skin and to allow subsequent interpretations of temperature distributions.
Resumo:
BACKGROUND Most European birds of prey find themselves in a poor state of conservation, with electrocution as one of the most frequent causes of unnatural death. Since early detection of electrocution is difficult, treatment is usually implemented late, which reduces its effectiveness. By considering that electrocution reduces tissue temperature, it may be detectable by thermography, which would allow a more rapid identification. Three individuals from three endangered raptor species [Spanish imperial eagle (Aquila adalberti), Lammergeier (Gypaetus barbatus) and Osprey (Pandion haliaetus)] were studied thermographically from the time they were admitted to a rehabilitation centre to the time their clinical cases were resolved. CASES PRESENTATION The three raptors presented lesions lacking thermal bilateral symmetry and were consistent with electrocution of feet, wings and eyes, visible by thermography before than clinically; lesions were well-defined and showed a lower temperature than the surrounding tissue. Some lesions evolved thermally and clinically until the appearance of normal tissue recovered, while others evolved and became necrotic. A histopathological analysis of a damaged finger amputated off a Lammergeier, and the necropsy and histopathology examination of an osprey, confirmed the electrocution diagnosis. CONCLUSIONS These results suggest that thermography is effective and useful for the objective and early detection and monitoring of electrocuted birds, and that it may prove especially useful for examining live animals that require no amputation or cannot be subjected to invasive histopathology.
Resumo:
The aim of this study was to correlate the testicular surface temperature with rectal temperature and semen quality in rams of different genotypic groups.
Resumo:
The building sector is the dominant consumer of energy and therefore a major contributor to anthropomorphic climate change. The rapid generation of photorealistic, 3D environment models with incorporated surface temperature data has the potential to improve thermographic monitoring of building energy efficiency. In pursuit of this goal, we propose a system which combines a range sensor with a thermal-infrared camera. Our proposed system can generate dense 3D models of environments with both appearance and temperature information, and is the first such system to be developed using a low-cost RGB-D camera. The proposed pipeline processes depth maps successively, forming an ongoing pose estimate of the depth camera and optimizing a voxel occupancy map. Voxels are assigned 4 channels representing estimates of their true RGB and thermal-infrared intensity values. Poses corresponding to each RGB and thermal-infrared image are estimated through a combination of timestamp-based interpolation and a pre-determined knowledge of the extrinsic calibration of the system. Raycasting is then used to color the voxels to represent both visual appearance using RGB, and an estimate of the surface temperature. The output of the system is a dense 3D model which can simultaneously represent both RGB and thermal-infrared data using one of two alternative representation schemes. Experimental results demonstrate that the system is capable of accurately mapping difficult environments, even in complete darkness.
Resumo:
This thesis is a comparative investigation of the methodology applied to human skin temperature measurement. The findings of this thesis suggest that clinical and significant differences exist between conductive and infrared devices which are commonly employed in the assessment of human skin temperature. These significant differences could potentially influence the interpretation of results, diagnosis and therefore treatment outcomes for health, clinical and exercise science applications.
Resumo:
The dynamic nature of tissue temperature and the subcutaneous properties, such as blood flow, fatness, and metabolic rate, leads to variation in local skin temperature. Therefore, we investigated the effects of using multiple regions of interest when calculating weighted mean skin temperature from four local sites. Twenty-six healthy males completed a single trial in a thermonetural laboratory (mean ± SD): 24.0 (1.2) °C; 56 (8%) relative humidity; < 0.1 m/s air speed). Mean skin temperature was calculated from four local sites (neck, scapula, hand and shin) in accordance with International Standards using digital infrared thermography. A 50 x 50 mm square, defined by strips of aluminium tape, created six unique regions of interest, top left quadrant, top right quadrant, bottom left quadrant, bottom right quadrant, centre quadrant and the entire region of interest, at each of the local sites. The largest potential error in weighted mean skin temperature was calculated using a combination of a) the coolest and b) the warmest regions of interest at each of the local sites. Significant differences between the six regions interest were observed at the neck (P < 0.01), scapula (P < 0.001) and shin (P < 0.05); but not at the hand (P = 0.482). The largest difference (± SEM) at each site was as follows: neck 0.2 (0.1) °C; scapula 0.2 (0.0) °C; shin 0.1 (0.0) °C and hand 0.1 (0.1) °C. The largest potential error (mean ± SD) in weighted mean skin temperature was 0.4 (0.1) °C (P < 0.001) and the associated 95% limits of agreement for these differences was 0.2 to 0.5 °C. Although we observed differences in local and mean skin temperature based on the region of interest employed, these differences were minimal and are not considered physiologically meaningful.
Resumo:
Skin temperature is an important physiological measure that can reflect the presence of illness and injury as well as provide insight into the localised interactions between the body and the environment. The aim of this systematic review was to analyse the agreement between conductive and infrared means of assessing skin temperature which are commonly employed in in clinical, occupational, sports medicine, public health and research settings. Full-text eligibility was determined independently by two reviewers. Studies meeting the following criteria were included in the review: 1) the literature was written in English, 2) participants were human (in vivo), 3) skin surface temperature was assessed at the same site, 4) with at least two commercially available devices employed—one conductive and one infrared—and 5) had skin temperature data reported in the study. A computerised search of four electronic databases, using a combination of 21 keywords, and citation tracking was performed in January 2015. A total of 8,602 were returned. Methodology quality was assessed by 2 authors independently, using the Cochrane risk of bias tool. A total of 16 articles (n = 245) met the inclusion criteria. Devices are classified to be in agreement if they met the clinically meaningful recommendations of mean differences within ±0.5 °C and limits of agreement of ±1.0 °C. Twelve of the included studies found mean differences greater than ±0.5 °C between conductive and infrared devices. In the presence of external stimulus (e.g. exercise and/or heat) five studies foundexacerbated measurement differences between conductive and infrared devices. This is the first review that has attempted to investigate presence of any systemic bias between infrared and conductive measures by collectively evaluating the current evidence base. There was also a consistently high risk of bias across the studies, in terms of sample size, random sequence generation, allocation concealment, blinding and incomplete outcome data. This systematic review questions the suitability of using infrared cameras in stable, resting, laboratory conditions. Furthermore, both infrared cameras and thermometers in the presence of sweat and environmental heat demonstrate poor agreement when compared to conductive devices. These findings have implications for clinical, occupational, public health, sports science and research fields.
Resumo:
Miniaturization of analytical instrumentation is attracting growing interest in response to the explosive demand for rapid, yet sensitive analytical methods and low-cost, highly automated instruments for pharmaceutical and bioanalyses and environmental monitoring. Microfabrication technology in particular, has enabled fabrication of low-cost microdevices with a high degree of integrated functions, such as sample preparation, chemical reaction, separation, and detection, on a single microchip. These miniaturized total chemical analysis systems (microTAS or lab-on-a-chip) can also be arrayed for parallel analyses in order to accelerate the sample throughput. Other motivations include reduced sample consumption and waste production as well as increased speed of analysis. One of the most promising hyphenated techniques in analytical chemistry is the combination of a microfluidic separation chip and mass spectrometer (MS). In this work, the emerging polymer microfabrication techniques, ultraviolet lithography in particular, were exploited to develop a capillary electrophoresis (CE) separation chip which incorporates a monolithically integrated electrospray ionization (ESI) emitter for efficient coupling with MS. An epoxy photoresist SU-8 was adopted as structural material and characterized with respect to its physicochemical properties relevant to chip-based CE and ESI/MS, namely surface charge, surface interactions, heat transfer, and solvent compatibility. As a result, SU-8 was found to be a favorable material to substitute for the more commonly used glass and silicon in microfluidic applications. In addition, an infrared (IR) thermography was introduced as direct, non-intrusive method to examine the heat transfer and thermal gradients during microchip-CE. The IR data was validated through numerical modeling. The analytical performance of SU-8-based microchips was established for qualitative and quantitative CE-ESI/MS analysis of small drug compounds, peptides, and proteins. The CE separation efficiency was found to be similar to that of commercial glass microchips and conventional CE systems. Typical analysis times were only 30-90 s per sample indicating feasibility for high-throughput analysis. Moreover, a mass detection limit at the low-attomole level, as low as 10E+5 molecules, was achieved utilizing MS detection. The SU-8 microchips developed in this work could also be mass produced at low cost and with nearly identical performance from chip to chip. Until this work, the attempts to combine CE separation with ESI in a chip-based system, amenable to batch fabrication and capable of high, reproducible analytical performance, have not been successful. Thus, the CE-ESI chip developed in this work is a substantial step toward lab-on-a-chip technology.
Resumo:
Wheat is occasionally exposed to freezing temperatures during ear emergence and can suffer severe frost damage. Few studies have attempted to understand the characteristics of freezing and frost damage to wheat during late development stages. It was clearly shown that wheat appears to have an inherent frost resistance to temperatures down to −5 °C but is extensively damaged below this temperature. Acclimation, whilst increasing the frost resistance of winter wheat in a vegetative state was incapable of increasing frost resistance of plants at ear emergence. It is proposed that the ability to upregulate frost resistance is lost once vernalisation requirement is fulfilled. Culms and ears of wheat were able to escape frost damage at temperatures below −5 °C by supercooling even to as low as −15 °C and evidence collected by infrared thermography suggested that individual culms on a plant froze as independent units during freezing with little or no cross ice-nucleation strategies to protect wheat from frost damage in the field appear to revolve around avoiding ice nucleation.