980 resultados para thermal management
Resumo:
Li-ion batteries have been widely used in the EVs, and the battery thermal management is a key but challenging part of the battery management system. For EV batteries, only the battery surface temperature can be measured in real-time. However, it is the battery internal temperature that directly affects the battery performance, and large temperature difference may exist between surface and internal temperatures, especially in high power demand applications. In this paper, an online battery internal temperature estimation method is proposed based on a novel simplified thermoelectric model. The battery thermal behaviour is first described by a simplified thermal model, and battery electrical behaviour by an electric model. Then, these two models are interrelated to capture the interactions between battery thermal and electrical behaviours, thus offer a comprehensive description of the battery behaviour that is useful for battery management. Finally, based on the developed model, the battery internal temperature is estimated using an extended Kalman filter. The experimental results confirm the efficacy of the proposed method, and it can be used for online internal temperature estimation which is a key indicator for better real-time battery thermal management.
Resumo:
The main purpose of this PhD thesis was to provide convincing demonstration for a breakthrough concept of pyroelectrolysis at laboratory scale. One attempted to identify fundamental objections and/or the most critical constraints, to propose workable concepts for the overall process and for feasible electrodes, and to establish the main requirements on a clearer basis. The main effort was dedicated to studying suitable anode materials to be developed for large scale industrial units with molten silicate electrolyte. This concept relies on consumable anodes based on iron oxides, and a liquid Fe cathode, separated from the refractory materials by a freeze lining (solid) layer. In addition, one assessed an alternative concept of pyroelectrolysis with electron blocking membranes, and developed a prototype at small laboratory scale. The main composition of the molten electrolyte was based on a magnesium aluminosilicate composition, with minimum liquidus temperature, and with different additions of iron oxide. One studied the dynamics of devitrification of these melts, crystallization of iron oxides or other phases, and Fe2+/Fe3+ redox changes under laser zone melting, at different pulling rates. These studies were intended to provide guidelines for dissolution of raw materials (iron oxides) in the molten electrolyte, to assess compatibility with magnetite based consumable anodes, and to account for thermal gradients or insufficient thermal management in large scale cells. Several laboratory scale prototype cells were used to demonstrate the concept of pyroelectrolysis with electron blocking, and to identify the most critical issues and challenges. Operation with and without electron blocking provided useful information on transport properties of the molten electrolyte (i.e., ionic and electronic conductivities), their expected dependence on anodic and cathodic overpotentials, limitations in faradaic efficiency, and onset of side electrochemical reactions. The concept of consumable anodes was based on magnetite and derived spinel compositions, for their expected redox stability at high temperatures, even under oxidising conditions. Spinel compositions were designed for prospective gains in refractoriness and redox stability in wider ranges of conditions (T, pO2 and anodic overpotentials), without excessive penalty for electrical conductivity, thermomechanical stability or other requirements. Composition changes were also mainly based on components of the molten aluminosilicate melt, to avoid undue contamination and to minimize the dissolution rate of consumable anodes. Additional changes in composition were intended for prospective pyroelectrolysis of Fe alloys, with additions of different elements (Cr, Mn, Ni, Ti).
Resumo:
Many-core platforms are an emerging technology in the real-time embedded domain. These devices offer various options for power savings, cost reductions and contribute to the overall system flexibility, however, issues such as unpredictability, scalability and analysis pessimism are serious challenges to their integration into the aforementioned area. The focus of this work is on many-core platforms using a limited migrative model (LMM). LMM is an approach based on the fundamental concepts of the multi-kernel paradigm, which is a promising step towards scalable and predictable many-cores. In this work, we formulate the problem of real-time application mapping on a many-core platform using LMM, and propose a three-stage method to solve it. An extended version of the existing analysis is used to assure that derived mappings (i) guarantee the fulfilment of timing constraints posed on worst-case communication delays of individual applications, and (ii) provide an environment to perform load balancing for e.g. energy/thermal management, fault tolerance and/or performance reasons.
Resumo:
Data centre is a centralized repository,either physical or virtual,for the storage,management and dissemination of data and information organized around a particular body and nerve centre of the present IT revolution.Data centre are expected to serve uniinterruptedly round the year enabling them to perform their functions,it consumes enormous energy in the present scenario.Tremendous growth in the demand from IT Industry made it customary to develop newer technologies for the better operation of data centre.Energy conservation activities in data centre mainly concentrate on the air conditioning system since it is the major mechanical sub-system which consumes considerable share of the total power consumption of the data centre.The data centre energy matrix is best represented by power utilization efficiency(PUE),which is defined as the ratio of the total facility power to the IT equipment power.Its value will be greater than one and a large value of PUE indicates that the sub-systems draw more power from the facility and the performance of the data will be poor from the stand point of energy conservation. PUE values of 1.4 to 1.6 are acievable by proper design and management techniques.Optimizing the air conditioning systems brings enormous opportunity in bringing down the PUE value.The air conditioning system can be optimized by two approaches namely,thermal management and air flow management.thermal management systems are now introduced by some companies but they are highly sophisticated and costly and do not catch much attention in the thumb rules.
Resumo:
Oxide free stable metallic nanofluids have the potential for various applications such as in thermal management and inkjet printing apart from being a candidate system for fundamental studies. A stable suspension of nickel nanoparticles of ∼5 nm size has been realized by a modified two-step synthesis route. Structural characterization by x-ray diffraction and transmission electron microscopy shows that the nanoparticles are metallic and are phase pure. The nanoparticles exhibited superparamagnetic properties. The magneto-optical transmission properties of the nickel nanofluid (Ni-F) were investigated by linear optical dichroism measurements. The magnetic field dependent light transmission studies exhibited a polarization dependent optical absorption, known as optical dichroism, indicating that the nanoparticles suspended in the fluid are non-interacting and superparamagnetic in nature. The nonlinear optical limiting properties of Ni-F under high input optical fluence were then analyzed by an open aperture z-scan technique. The Ni-F exhibits a saturable absorption at moderate laser intensities while effective two-photon absorption is evident at higher intensities. The Ni-F appears to be a unique material for various optical devices such as field modulated gratings and optical switches which can be controlled by an external magnetic field
Resumo:
Introducción: La hipotermia perioperatoria se ha documentado como factor de riesgo para el aumento de la morbimortalidad de los pacientes aumentando morbilidad miocárdica, riesgo de infección, pérdidas sanguíneas y tiempo de hospitalización. La aplicación de anestésicos toma relevancia ya que causa la pérdida de control central de la temperatura. Nuestro objetivo con este estudio fue describir la proporción de casos de hipotermia en la población sometida a un reemplazo articular durante un periodo de cuatro meses. Materiales y métodos: Se realizó un estudio de cohorte prospectivo. La población a estudio fueron los pacientes que fueron sometidos a un reemplazo total de cadera, rodilla u hombro. Se registró la temperatura central en el momento previo a la inducción anestésica, 30, 60 y 90 minutos después, al finalizar el procedimiento y al ingresar a recuperación. Se reportó el porcentaje de pacientes con hipotermia en cada tiempo. Resultados: Se analizaron en total 88 pacientes, el 55,7% fue llevado a cirugía de cadera, 39,7% de rodilla y 4,5% de hombro. El tipo de anestesia más utilizado fue general y la duración promedio de anestesia fue 164 minutos. La medición de la temperatura central se realizó en nasofaringe, esófago o tímpano. La proporción de pacientes que presentaron hipotermia en la inducción fue 21,6%, a 30 minutos 83%, a 60 minutos 73,9%, a 90 minutos 68,2%, al finalizar 59,1% y en recuperación 58%. Se realizó una prueba Chi cuadrado comparando las proporciones entre la inducción y los cinco periodos posteriores, se encontró que la proporción de pacientes con hipotermia en los cinco tiempos posteriores tuvo una diferencia estadísticamente significativa (p=0,00) comparada con la proporción de pacientes con hipotermia durante la inducción. Conclusión: En los pacientes sometidos a un reemplazo articular la hipotermia fue una condición prevalente posterior a la aplicación de los anestésicos sistémicos. Los dispositivos de calentamiento intraoperatorio usados actualmente son insuficientes para evitar la hipotermia, lo que indica concordancia con la literatura en cuanto a las recomendaciones de calentamiento perioperatorio, con énfasis en el precalentamiento, para prevenir la caída significativa de la temperatura y la morbimortalidad asociada.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
The process of spermatic division and differentiation (spermatogenesis) occurs with intratesticular temperature lower that the corporal temperature and for that is essential that the testicular thermoregulation mechanism occurs properly. For evaluation of the scrotal surface temperature can be used the infrared thermography or testicular sensors, besides that, can be evaluated the blood flux in the spermatic cord through the Doppler ultrasonography. Therefore the objective of this study was the evaluation of the scrotal thermography and Doppler flowmetry of the testicular artery of buffaloes subjected to environmental heat stress. For that were used seven healthy buffaloes, with age of 3 and 4 years, of the Murrah breed. For the surface scrotal temperature measurement (SST, degrees C) and superficial neck temperature (SNT, degrees C) was used the infrared termography (Infra Cam (TM) of the brand FLIR Systems Inc.), then Doppler flowmetry of the testicular artery in the region of the spermatic cord through the ultrasonography (Mylab 5, Esaote (R)) and measurement of the rectal temperature (RT, degrees C). The evaluations were done in two moments: moment 1 (M1) with all the animals in the shade (Temperature=32,2 degrees C) and moment 2 (M2) after 3 hours of exposure of animals to the sun (Temperature=38,7 degrees C To calculate the resistivity index (RI) and pulsatility index (PI), spectra were obtained from pulsed Doppler in three random regions of the testicular artery in the spermatic cord. Data were subjected to analysis of variance (ANOVA) followed by T test, using a significance level of 5%. There was an increase (p<0,05) of RT (37,4 +/- 0,4(a) vs 39,0 +/- 0,3(b); M1 and M2 respectively), SST (30,6 +/- 1,4(a) vs 35,2,0 +/- 1,0(b); M1 and M2 respectively) and SNT (33,1 +/- 2,5(a) vs 38,5,0 +/- 0,3(b); M1 e M2 respectively) e RI (0,67 +/- 0,1(a) vs 0,74 +/- 0,1(b); M1 e M2 respectively) in M2. Increasing trend was observed (0,05>p>0,01) in PI (1,10 +/- 0,4(a) vs 1,23 +/- 0,2(b); M1 and M2 respectively) in M2. The results of the present study allow us to conclude the healthy buffaloes have the scrotal average surface temperature 3 degrees C lower that the body temperature and that the exposure of 3 hours to sun in healthy buffaloes causes thermal stress to the animals and changes in its surface scrotal temperature, and the Doppler flowmetry of the testicular artery demonstrating the importance of thermal management for breeding buffaloes. Besides that, the thermography and the Doppler ultrasonography presented great potential to detect changes of testicular perfusion, being a promising additional test in the buffalo andrological evaluation.
Resumo:
Pós-graduação em Engenharia Elétrica - FEIS
Resumo:
The digital electronic market development is founded on the continuous reduction of the transistors size, to reduce area, power, cost and increase the computational performance of integrated circuits. This trend, known as technology scaling, is approaching the nanometer size. The lithographic process in the manufacturing stage is increasing its uncertainty with the scaling down of the transistors size, resulting in a larger parameter variation in future technology generations. Furthermore, the exponential relationship between the leakage current and the threshold voltage, is limiting the threshold and supply voltages scaling, increasing the power density and creating local thermal issues, such as hot spots, thermal runaway and thermal cycles. In addiction, the introduction of new materials and the smaller devices dimension are reducing transistors robustness, that combined with high temperature and frequently thermal cycles, are speeding up wear out processes. Those effects are no longer addressable only at the process level. Consequently the deep sub-micron devices will require solutions which will imply several design levels, as system and logic, and new approaches called Design For Manufacturability (DFM) and Design For Reliability. The purpose of the above approaches is to bring in the early design stages the awareness of the device reliability and manufacturability, in order to introduce logic and system able to cope with the yield and reliability loss. The ITRS roadmap suggests the following research steps to integrate the design for manufacturability and reliability in the standard CAD automated design flow: i) The implementation of new analysis algorithms able to predict the system thermal behavior with the impact to the power and speed performances. ii) High level wear out models able to predict the mean time to failure of the system (MTTF). iii) Statistical performance analysis able to predict the impact of the process variation, both random and systematic. The new analysis tools have to be developed beside new logic and system strategies to cope with the future challenges, as for instance: i) Thermal management strategy that increase the reliability and life time of the devices acting to some tunable parameter,such as supply voltage or body bias. ii) Error detection logic able to interact with compensation techniques as Adaptive Supply Voltage ASV, Adaptive Body Bias ABB and error recovering, in order to increase yield and reliability. iii) architectures that are fundamentally resistant to variability, including locally asynchronous designs, redundancy, and error correcting signal encodings (ECC). The literature already features works addressing the prediction of the MTTF, papers focusing on thermal management in the general purpose chip, and publications on statistical performance analysis. In my Phd research activity, I investigated the need for thermal management in future embedded low-power Network On Chip (NoC) devices.I developed a thermal analysis library, that has been integrated in a NoC cycle accurate simulator and in a FPGA based NoC simulator. The results have shown that an accurate layout distribution can avoid the onset of hot-spot in a NoC chip. Furthermore the application of thermal management can reduce temperature and number of thermal cycles, increasing the systemreliability. Therefore the thesis advocates the need to integrate a thermal analysis in the first design stages for embedded NoC design. Later on, I focused my research in the development of statistical process variation analysis tool that is able to address both random and systematic variations. The tool was used to analyze the impact of self-timed asynchronous logic stages in an embedded microprocessor. As results we confirmed the capability of self-timed logic to increase the manufacturability and reliability. Furthermore we used the tool to investigate the suitability of low-swing techniques in the NoC system communication under process variations. In this case We discovered the superior robustness to systematic process variation of low-swing links, which shows a good response to compensation technique as ASV and ABB. Hence low-swing is a good alternative to the standard CMOS communication for power, speed, reliability and manufacturability. In summary my work proves the advantage of integrating a statistical process variation analysis tool in the first stages of the design flow.
Resumo:
Space-based (satellite, scientific probe, space station, etc.) and millimeter – to – microscale (such as are used in high power electronics cooling, weapons cooling in aircraft, etc.) condensers and boilers are shear/pressure driven. They are of increasing interest to system engineers for thermal management because flow boilers and flow condensers offer both high fluid flow-rate-specific heat transfer capacity and very low thermal resistance between the fluid and the heat exchange surface, so large amounts of heat may be removed using reasonably-sized devices without the need for excessive temperature differences. However, flow stability issues and degradation of performance of shear/pressure driven condensers and boilers due to non-desirable flow morphology over large portions of their lengths have mostly prevented their use in these applications. This research is part of an ongoing investigation seeking to close the gap between science and engineering by analyzing two key innovations which could help address these problems. First, it is recommended that the condenser and boiler be operated in an innovative flow configuration which provides a non-participating core vapor stream to stabilize the annular flow regime throughout the device length, accomplished in an energy-efficient manner by means of ducted vapor re-circulation. This is demonstrated experimentally. Second, suitable pulsations applied to the vapor entering the condenser or boiler (from the re-circulating vapor stream) greatly reduce the thermal resistance of the already effective annular flow regime. For experiments reported here, application of pulsations increased time-averaged heat-flux up to 900 % at a location within the flow condenser and up to 200 % at a location within the flow boiler, measured at the heat-exchange surface. Traditional fully condensing flows, reported here for comparison purposes, show similar heat-flux enhancements due to imposed pulsations over a range of frequencies. Shear/pressure driven condensing and boiling flow experiments are carried out in horizontal mm-scale channels with heat exchange through the bottom surface. The sides and top of the flow channel are insulated. The fluid is FC-72 from 3M Corporation.
Resumo:
Phase changing flows are being considered for thermal management in space platforms. The resulting flow patterns are very complicated and extremely sensitive to gravity action. Concerning fluid flow in ducts, the available evidence indicates that although the pressure loss does not depend too much on the fluid flow pattern,the heat transfer (and resulting phase change) does. A simple exercise to illustrate this point is presented in this paper. It deals with condensing flow in straight circular cross-sectional ducts. Two extreme configurations are considered here, one corresponds to a stratified flow and the other to an annular flow. Both types of flow patterns have been extensively considered in the past and from this point of view almost nothing is new in the paper, but past results look conflictive and this could be due to the limitations and computational intricacies of the models used. Thus the problem has been reformulated from the onset and the results are presented as the evolution of the vapor quality (vapor to total mass flow rate) along the duct, in typical cases. The results presented here indicate that within the validity of the present models and the assumed ranges of mass flow rate, duct diameter, thermal conditions and fluid characteristics,the length of the ducts required to achieve complete condensation under zero gravity are an order of magnitude larger than in horizontal tubes under normal terrestrial conditions.
Resumo:
Dynamic thermal management techniques require a collection of on-chip thermal sensors that imply a significant area and power overhead. Finding the optimum number of temperature monitors and their location on the chip surface to optimize accuracy is an NP-hard problem. In this work we improve the modeling of the problem by including area, power and networking constraints along with the consideration of three inaccuracy terms: spatial errors, sampling rate errors and monitor-inherent errors. The problem is solved by the simulated annealing algorithm. We apply the algorithm to a test case employing three different types of monitors to highlight the importance of the different metrics. Finally we present a case study of the Alpha 21364 processor under two different constraint scenarios.
Resumo:
In this paper, implementation and testing of non- commercial GaN HEMT in a simple buck converter for envelope amplifier in ET and EER transmission techn iques has been done. Comparing to the prototypes with commercially available EPC1014 and 1015 GaN HEMTs, experimentally demonstrated power supply provided better thermal management and increased the switching frequency up to 25MHz. 64QAM signal with 1MHz of large signal bandw idth and 10.5dB of Peak to Average Power Ratio was gener ated, using the switching frequency of 20MHz. The obtaine defficiency was 38% including the driving circuit an d the total losses breakdown showed that switching power losses in the HEMT are the dominant ones. In addition to this, some basic physical modeling has been done, in order to provide an insight on the correlation between the electrical characteristics of the GaN HEMT and physical design parameters. This is the first step in the optimization of the HEMT design for this particular application.
Resumo:
This letter presents a temperature-sensing technique on the basis of the temperature dependency of MOSFET leakage currents. To mitigate the effects of process variation, the ratio of two different leakage current measurements is calculated. Simulations show that this ratio is robust to process spread. The resulting sensor is quite small-0.0016 mm2 including an analog-to-digital conversion-and very energy efficient, consuming less than 640 pJ/conversion. After a two-point calibration, the accuracy in a range of 40°C-110°C is less than 1.5°C , which makes the technique suitable for thermal management applications.