968 resultados para steady state analysis
Resumo:
The impact of radial k-space sampling and water-selective excitation on a novel navigator-gated cardiac-triggered slab-selective inversion prepared 3D steady-state free-precession (SSFP) renal MR angiography (MRA) sequence was investigated. Renal MRA was performed on a 1.5-T MR system using three inversion prepared SSFP approaches: Cartesian (TR/TE: 5.7/2.8 ms, FA: 85 degrees), radial (TR/TE: 5.5/2.7 ms, FA: 85 degrees) SSFP, and radial SSFP combined with water-selective excitation (TR/TE: 9.9/4.9 ms, FA: 85 degrees). Radial data acquisition lead to significantly reduced motion artifacts (P < 0.05). SNR and CNR were best using Cartesian SSFP (P < 0.05). Vessel sharpness and vessel length were comparable in all sequences. The addition of a water-selective excitation could not improve image quality. In conclusion, radial k-space sampling reduces motion artifacts significantly in slab-selective inversion prepared renal MRA, while SNR and CNR are decreased. The addition of water-selective excitation could not improve the lower CNR in radial scanning.
Resumo:
PURPOSE: To investigate the potential of free-breathing 3D steady-state free precession (SSFP) imaging with radial k-space sampling for coronary MR-angiography (MRA), coronary projection MR-angiography and coronary vessel wall imaging. MATERIALS AND METHODS: A navigator-gated free-breathing T2-prepared 3D SSFP sequence (TR = 6.1 ms, TE = 3.0 ms, flip angle = 120 degrees, field-of-view = 360 mm(2)) with radial k-space sampling (384 radials) was implemented for coronary MRA. For projection coronary MRA, this sequence was combined with a 2D selective aortic spin tagging pulse. Coronary vessel wall imaging was performed using a high-resolution inversion-recovery black-blood 3D radial SSFP sequence (384 radials, TR = 5.3 ms, TE = 2.7 ms, flip angle = 55 degrees, reconstructed resolution 0.35 x 0.35 x 1.2 mm(3)) and a local re-inversion pulse. Six healthy volunteers (two for each sequence) were investigated. Motion artifact level was assessed by two radiologists. Results: In coronary MRA, the coronary lumen was displayed with a high signal and high contrast to the surrounding lumen. Projection coronary MRA demonstrated selective visualization of the coronary lumen while surrounding tissue was almost completely suppressed. In coronary vessel wall imaging, the vessel wall was displayed with a high signal when compared to the blood pool and the surrounding tissue. No visible motion artifacts were seen. Conclusion: 3D radial SSFP imaging enables coronary MRA, coronary projection MRA and coronary vessel wall imaging with a low motion artifact level.
Resumo:
Steady state plasma concentrations of the (L)- and (D)-enantiomers of trimipramine (TRI), desmethyltrimipramine (DTRI), 2-hydroxytrimipramine (TRIOH) and 2-hydroxydesmethyl-trimipramine (DTRIOH) were measured in 27 patients receiving between 300 and 400 mg/day racemic TRI. The patients were phenotyped with dextromethorphan and mephenytoin, and the 8-hour urinary ratios of dextromethorphan/dextrorphan, dextromethorphan/3-methoxymorphinan, and (S)-mephenytoin/(R)mephenytoin were used as markers of cytochrome P-450IID6 (CYP2D6), CYP3A4/5 and CYP2C19 activities, respectively. One patient was a CYP2D6 and one was a CYP2C19 poor metabolizer. A stereoselectivity in the metabolism of TRI has been found, with a preferential N-demethylation of (D)-TRI and a preferential hydroxylation of (L)-TRI. CYP2D6 appears to be involved in the 2-hydroxylation of (L)-TRI, (L)DTRI and (D)-DTRI, but not of (D)-TRI, as significant correlations were measured between the dextromethorphan/dextrorphan ratios and the (L)-TRI/(L)-TRIOH (r = 0.45, p = 0.019), the (L)-DTRI/(L)-DTRIOH (r = 0.47, p = 0.014), and the (D)-DTRI/(D)-DTRIOH (r = 0.51, p = 0.006), but not with the (D)-TRI/(D)-TRIOH ratios (r = 0.29, NS). CYP2C19, but not CYP2D6, appears to be involved in the demethylation pathway, with a stereoselectivity toward the (D)-enantiomer of TRI, as a significant positive correlation was calculated between the mephenytoin (S)/(R) ratios and the concentrations to dose-to-weight ratios of (D)-TRI (r = 0.69, p = 0.00006). CYP3A4/5 appears to be involved in the metabolism of (L)-TRI to a presently not determined metabolite. The CYP2D6 poor metabolizer had the highest (L)-DTRI and (D)-DTRI concentrations to dose-to-weight ratios, and the CYP2C19 poor metabolizer had the highest (L)-TRI and (D)-TRI concentrations to dose-to-weight ratios of the group.
Resumo:
Barbiturates are regularly used as an anesthetic for animal experimentation and clinical procedures and are frequently provided with solubilizing compounds, such as ethanol and propylene glycol, which have been reported to affect brain function and, in the case of (1)H NMR experiments, originate undesired resonances in spectra affecting the quantification. As an alternative, thiopental can be administrated without any solubilizing agents. The aim of the study was to investigate the effect of deep thiopental anesthesia on the neurochemical profile consisting of 19 metabolites and on glucose transport kinetics in vivo in rat cortex compared with alpha-chloralose using localized (1)H NMR spectroscopy. Thiopental was devoid of effects on the neurochemical profile, except for the elevated glucose at a given plasma glucose level resulting from thiopental-induced depression of glucose consumption at isoelectrical condition. Over the entire range of plasma glucose levels, steady-state glucose concentrations were increased on average by 48% +/- 8%, implying that an effect of deep thiopental anesthesia on the transport rate relative to cerebral glucose consumption ratio was increased by 47% +/- 8% compared with light alpha-chloralose-anesthetized rats. We conclude that the thiopental-induced isoelectrical condition in rat cortex significantly affected glucose contents by depressing brain metabolism, which remained substantial at isoelectricity.
Resumo:
Barbiturates are regularly used as an anesthetic for animal experimentation and clinical procedures and are frequently provided with solubilizing compounds, such as ethanol and propylene glycol, which have been reported to affect brain function and, in the case of (1)H NMR experiments, originate undesired resonances in spectra affecting the quantification. As an alternative, thiopental can be administrated without any solubilizing agents. The aim of the study was to investigate the effect of deep thiopental anesthesia on the neurochemical profile consisting of 19 metabolites and on glucose transport kinetics in vivo in rat cortex compared with alpha-chloralose using localized (1)H NMR spectroscopy. Thiopental was devoid of effects on the neurochemical profile, except for the elevated glucose at a given plasma glucose level resulting from thiopental-induced depression of glucose consumption at isoelectrical condition. Over the entire range of plasma glucose levels, steady-state glucose concentrations were increased on average by 48% +/- 8%, implying that an effect of deep thiopental anesthesia on the transport rate relative to cerebral glucose consumption ratio was increased by 47% +/- 8% compared with light alpha-chloralose-anesthetized rats. We conclude that the thiopental-induced isoelectrical condition in rat cortex significantly affected glucose contents by depressing brain metabolism, which remained substantial at isoelectricity.
Resumo:
PURPOSE: To investigate the ability of inversion recovery ON-resonant water suppression (IRON) in conjunction with P904 (superparamagnetic nanoparticles which consisting of a maghemite core coated with a low-molecular-weight amino-alcohol derivative of glucose) to perform steady-state equilibrium phase MR angiography (MRA) over a wide dose range. MATERIALS AND METHODS: Experiments were approved by the institutional animal care committee. Rabbits (n = 12) were imaged at baseline and serially after the administration of 10 incremental dosages of 0.57-5.7 mgFe/Kg P904. Conventional T1-weighted and IRON MRA were obtained on a clinical 1.5 Tesla (T) scanner to image the thoracic and abdominal aorta, and peripheral vessels. Contrast-to-noise ratios (CNR) and vessel sharpness were quantified. RESULTS: Using IRON MRA, CNR and vessel sharpness progressively increased with incremental dosages of the contrast agent P904, exhibiting constantly higher contrast values than T1 -weighted MRA over a very wide range of contrast agent doses (CNR of 18.8 ± 5.6 for IRON versus 11.1 ± 2.8 for T1 -weighted MRA at 1.71 mgFe/kg, P = 0.02 and 19.8 ± 5.9 for IRON versus -0.8 ± 1.4 for T1-weighted MRA at 3.99 mgFe/kg, P = 0.0002). Similar results were obtained for vessel sharpness in peripheral vessels, (Vessel sharpness of 46.76 ± 6.48% for IRON versus 33.20 ± 3.53% for T1-weighted MRA at 1.71 mgFe/Kg, P = 0.002, and of 48.66 ± 5.50% for IRON versus 19.00 ± 7.41% for T1-weighted MRA at 3.99 mgFe/Kg, P = 0.003). CONCLUSION: Our study suggests that quantitative CNR and vessel sharpness after the injection of P904 are consistently higher for IRON MRA when compared with conventional T1-weighted MRA. These findings apply for a wide range of contrast agent dosages.
Resumo:
We study the interfacial modes of a driven diffusive model under suitable nonequilibrium conditions leading to possible instability. The external field parallel to the interface, which sets up a steady-state parallel flux, enhances the growth or decay rates of the interfacial modes. More dramatically, asymmetry in the model can introduce an oscillatory component into the interfacial dispersion relation. In certain circumstances, the applied field behaves as a singular perturbation.
Resumo:
We derive a simple closed analytical expression for the total entropy production along a single stochastic trajectory of a Brownian particle diffusing on a periodic potential under an external constant force. By numerical simulations we compute the probability distribution functions of the entropy and satisfactorily test many of the predictions based on Seiferts integral fluctuation theorem. The results presented for this simple model clearly illustrate the practical features and implications derived from such a result of nonequilibrium statistical mechanics.
Resumo:
Steady-state blood concentrations of (R)- methadone (i.e., the active form), (S)-methadone, and (R,S)-methadone were measured before and after introduction of paroxetine 20 mg/day during a mean period of 12 days in 10 addict patients in methadone maintenance treatment. Eight patients were genotyped as CYP2D6 homozygous extensive metabolizers (EMs) and two patients as poor metabolizers (PMs). Paroxetine significantly increased concentrations of both enantiomers of methadone in the whole group (mean increase for (R)-methadone +/- SD, 26 +/- 32%; range, -14% to +83%, p = 0.032; for (S)-methadone, 49 +/- 51%; range, -29% to +137%, p = 0.028; for (R,S)-methadone, 35 +/- 41%; range, -20% to +112%, p = 0.032) and in the group of eight EMs (mean increase, 32%, p = 0.036; 53%, p = 0.028; and 42%, p = 0.036, for (R)-methadone, (S)-methadone, and (R,S)-methadone, respectively). On the other hand, in the two PMs, (S)-methadone but not (R)-methadone concentrations were increased by paroxetine (mean increases of 36% and 3%, respectively). Paroxetine is a strong CYP2D6 inhibitor, and these results confirm previous studies showing an involvement of CYP2D6 in methadone metabolism with a stereoselectivity toward the (R)-enantiomer. Because paroxetine is a mild inhibitor of CYP1A2, CYP2C9, CYP2C19, and CYP3A4, increase of (S)-methadone concentrations in both EMs and PMs could be mediated by inhibition of any of these isozymes.
Resumo:
The effect of aging on steady-state plasma concentrations of citalopram (CIT) and desmethylcitalopram (DCIT) was investigated in 128 depressive patients treated with 10-80 mg/day CIT. They were separated into three groups, with age up to 64 years (mean age+/-S.D.: 47+/-12 years; n=48), between 65 and 79 years (72+/-1 years; n=57), and from 80 years or older (84+/-1 years; n=23). Body mass index (BMI), renal and hepatic functions were similar in the three groups. A large interindividual variability of plasma levels of CIT (16-fold) and DCIT (12-fold) was measured for a given dose. The mean plasma levels of CIT corrected for a 20 mg daily dose were 55% higher in the very elderly (>=80 years) patients (65+/-30 ng/ml; p<0.001) and 38% higher in the elderly (65-79 years) patients (58+/-24 ng/ml; p<0.001) when compared to the adult patients (42+/-17 ng/ml). DCIT mean plasma level was 38% higher (p<0.05) in the group of very elderly patients (22+/-10 ng/ml) when compared to the adult patients (16+/-9 ng/ml). As a consequence, the mean plasma concentration of CIT+DCIT was 48% higher in the very elderly patients (86+/-36 ng/ml; p<0.001) and 33% higher in the elderly patients (77+/-28 ng/ml; p<0.001) when compared to the adult patients (58+/-21 ng/ml). Age correlated significantly with CIT (r=0.43, p<0.001), DCIT (r=0.28, p<0.01), and CIT+DCIT plasma levels (r=0.44, p<0.001), and thus accounts for 18% of the variability of CIT plasma levels, with no influence of gender. The recommended dose reduction of CIT in elderly patients seems therefore justified.
Resumo:
PURPOSE: To compare 3 different flow targeted magnetization preparation strategies for coronary MR angiography (cMRA), which allow selective visualization of the vessel lumen. MATERIAL AND METHODS: The right coronary artery of 10 healthy subjects was investigated on a 1.5 Tesla MR system (Gyroscan ACS-NT, Philips Healthcare, Best, NL). A navigator-gated and ECG-triggered 3D radial steady-state free-precession (SSFP) cMRA sequence with 3 different magnetization preparation schemes was performed referred to as projection SSFP (selective labeling of the aorta, subtraction of 2 data sets), LoReIn SSFP (double-inversion preparation, selective labeling of the aorta, 1 data set), and inflow SSFP (inversion preparation, selective labeling of the coronary artery, 1 data set). Signal-to-noise ratio (SNR) of the coronary artery and aorta, contrast-to-noise ratio (CNR) between the coronary artery and epicardial fat, vessel length and vessel sharpness were analyzed. RESULTS: All cMRA sequences were successfully obtained in all subjects. Both projection SSFP and LoReIn SSFP allowed for selective visualization of the coronary arteries with excellent background suppression. Scan time was doubled in projection SSFP because of the need for subtraction of 2 data sets. In inflow SSFP, background suppression was limited to the tissue included in the inversion volume. Projection SSFP (SNR(coro): 25.6 +/- 12.1; SNR(ao): 26.1 +/- 16.8; CNR(coro-fat): 22.0 +/- 11.7) and inflow SSFP (SNR(coro): 27.9 +/- 5.4; SNR(ao): 37.4 +/- 9.2; CNR(coro-fat): 24.9 +/- 4.8) yielded significantly increased SNR and CNR compared with LoReIn SSFP (SNR(coro): 12.3 +/- 5.4; SNR(ao): 11.8 +/- 5.8; CNR(coro-fat): 9.8 +/- 5.5; P < 0.05 for both). Longest visible vessel length was found with projection SSFP (79.5 mm +/- 18.9; P < 0.05 vs. LoReIn) whereas vessel sharpness was best in inflow SSFP (68.2% +/- 4.5%; P < 0.05 vs. LoReIn). Consistently good image quality was achieved using inflow SSFP likely because of the simple planning procedure and short scanning time. CONCLUSION: Three flow targeted cMRA approaches are presented, which provide selective visualization of the coronary vessel lumen and in addition blood flow information without the need of contrast agent administration. Inflow SSFP yielded highest SNR, CNR and vessel sharpness and may prove useful as a fast and efficient approach for assessing proximal and mid vessel coronary blood flow, whereas requiring less planning skills than projection SSFP or LoReIn SSFP.
Resumo:
BACKGROUND: The aim of our study was the investigation of a novel navigator-gated three-dimensional (3D) steady-state free-precession (SSFP) sequence for free-breathing renal magnetic resonance angiography (MRA) without contrast medium, and to examine the advantage of an additional inversion prepulse for improved contrast. METHODS: Eight healthy volunteers (mean age 29 years) and eight patients (mean age 53 years) were investigated on a 1.5 Tesla MR system (ACS-NT, Philips, Best, The Netherlands). Renal MRA was performed using three navigator-gated free-breathing cardiac-triggered 3D SSFP sequences [repetition time (TR) = 4.4 ms, echo time (TE) = 2.2 ms, flip angle 85 degrees, spatial resolution 1.25 x 1.25 x 4.0 mm(3), scanning time approximately 1 minute 30 seconds]. The same sequence was performed without magnetization preparation, with a non-slab selective and a slab-selective inversion prepulse. Signal-to-noise ratio (SNR), contrast-to-noise (CNR) vessel length, and subjective image quality were compared. RESULTS: Three-dimensional SSFP imaging combined with a slab-selective inversion prepulse enabled selective and high contrast visualization of the renal arteries, including the more distal branches. Standard SSFP imaging without magnetization preparation demonstrated overlay by veins and renal parenchyma. A non-slab-selective prepulse abolished vessel visualization. CNR in SSFP with slab-selective inversion was 43.6 versus 10.6 (SSFP without magnetization preparation) and 0.4 (SSFP with non-slab-selective inversion), P < 0.008. CONCLUSION: Navigator-gated free-breathing cardiac-triggered 3D SSFP imaging combined with a slab-selective inversion prepulse is a novel, fast renal MRA technique without the need for contrast media.
Resumo:
The authors compared radial steady-state free precession (SSFP) coronary magnetic resonance (MR) angiography, cartesian k-space sampling SSFP coronary MR angiography, and gradient-echo coronary MR angiography in 16 healthy adults and four pilot study patients. Standard gradient-echo MR imaging with a T2 preparatory pulse and cartesian k-space sampling was the reference technique. Image quality was compared by using subjective motion artifact level and objective contrast-to-noise ratio and vessel sharpness. Radial SSFP, compared with cartesian SSFP and gradient-echo MR angiography, resulted in reduced motion artifacts and superior vessel sharpness. Cartesian SSFP resulted in increased motion artifacts (P <.05). Contrast-to-noise ratio with radial SSFP was lower than that with cartesian SSFP and similar to that with the reference technique. Radial SSFP coronary MR angiography appears preferable because of improved definition of vessel borders.
MRI of coronary vessel walls using radial k-space sampling and steady-state free precession imaging.
Resumo:
OBJECTIVE: The objective of our study was to investigate the impact of radial k-space sampling and steady-state free precession (SSFP) imaging on image quality in MRI of coronary vessel walls. SUBJECTS AND METHODS: Eleven subjects were examined on a 1.5-T MR system using three high-resolution navigator-gated and cardiac-triggered 3D black blood sequences (cartesian gradient-echo [GRE], radial GRE, and radial SSFP) with identical spatial resolution (0.9 x 0.9 x 2.4 mm3). The signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), vessel wall sharpness, and motion artifacts were analyzed. RESULTS: The mean SNR and CNR of the coronary vessel wall were improved using radial imaging and were best using radial k-space sampling combined with SSFP imaging. Vessel border definition was similar for all three sequences. Radial k-space sampling was found to be less sensitive to motion. Consistently good image quality was seen with the radial GRE sequence. CONCLUSION: Radial k-space sampling in MRI of coronary vessel walls resulted in fewer motion artifacts and improved SNR and CNR. The use of SSFP imaging, however, did not result in improved coronary vessel wall visualization.
Resumo:
AB Summary: Steady state concentrations of (S)- and (R)-mianserin and desmethylmianserin were measured in 21 homozygous extensive metabolizers (as determined by genotyping for mutations 3 [or A] and 4 [or B]), in seven heterozygous extensive metabolizers and in one poor metabolizer of debrisoquine, as well as in one patient receiving very high doses of mianserin (360 mg/day) and fluoxetine (160 mg/day), a strong cytochrome P450IID6 inhibitor. The mean dose of mianserin was (mean +/- SD, range: 67 +/- 63, 10 to 360 mg/day). High dispersions of the (S)/(R)-mianserin and desmethylmianserin ratios were observed (mean +/- SD, range: 2.10+/- 1.01, 0.64 to 4.76, and 0.29 +/- 0.14, 0.08 to 0.57, respectively). The highest (S)/(R)-mianserin ratio was calculated for the poor metabolizer (4.76) agreeing with those results of a single-dose study with poor and extensive metabolizers of debrisoquine, in that the cytochrome P450IID6 is probably involved in the metabolism of mianserin with an enantioselectivity for the (S)-enantiomer. Nevertheless, the mean concentration-to-dose ratios for (S)- or (R)-mianserin or desmethylmianserin were not significantly different between homozygous and heterozygous extensive metabolizers, and no particular values were measured in the poor metabolizer nor in the patient receiving fluoxetine. Furthermore, the(S)/(R)-mianserin ratio measured in the PM was only slightly higher than the second highest ratio (3.85) of an homozygous extensive metabolizer, whereas no particular value (2.92) was calculated for the patient taking fluoxetine. Finally, no significant differences in (S)/(R)-mianserin or(S)/(R)-desmethylmianserin were calculated between homozygous and heterozygous extensive metabolizers. Although the number of patients included in this study is too low to allow definite conclusions, the results suggest that the debrisoquine genotype has only a moderate influence on the steady state concentrations of the enantiomers of mianserin and desmethylmianserin. (C) Lippincott-Raven Publishers