963 resultados para multi-source noise


Relevância:

40.00% 40.00%

Publicador:

Resumo:

The fast sequential multi-element determination of Ca, Mg, K, Cu, Fe, Mn and Zn in plant tissues by high-resolution continuum source flame atomic absorption spectrometry is proposed. For this, the main lines for Cu (324.754 nm), Fe (248.327 nm), Mn (279.482 nm) and Zn (213.857 nm) were selected, and the secondary lines for Ca (239.856 nm), Mg (202.582 nm) and K (404.414 nm) were evaluated. The side pixel registration approach was studied to reduce sensitivity and extend the linear working range for Mg by measuring at wings (202.576 nm; 202.577 nm; 202.578 nm; 202.580 nm: 202.585 nm; 202.586 nm: 202.587 nm; 202.588 nm) of the secondary line. The interference caused by NO bands on Zn at 213.857 nm was removed using the least-squares background correction. Using the main lines for Cu, Fe, Mn and Zn, secondary lines for Ca and K, and line wing at 202.588 nm for Mg, and 5 mL min(-1) sample flow-rate, calibration curves in the 0.1-0.5 mg L-1 Cu, 0.5-4.0 mg L-1 Fe, 0.5-4.0 mg L-1 Mn, 0.2-1.0 mg L-1 Zn, 10.0-100.0 mg L-1 Ca, 5.0-40.0 mg L-1 Mg and 50.0-250.0 mg L-1 K ranges were consistently obtained. Accuracy and precision were evaluated after analysis of five plant standard reference materials. Results were in agreement at a 95% confidence level (paired t-test) with certified values. The proposed method was applied to digests of sugar-cane leaves and results were close to those obtained by line-source flame atomic absorption spectrometry. Recoveries of Ca, Mg, K, Cu, Fe, Mn and Zn in the 89-103%, 84-107%, 87-103%, 85-105%, 92-106%, 91-114%, 96-114% intervals, respectively, were obtained. The limits of detection were 0.6 mg L-1 Ca, 0.4 mg L-1 Mg, 0.4 mg L-1 K, 7.7 mu g L-1 Cu, 7.7 mu g L-1 Fe, 1.5 mu g L-1 Mn and 5.9 mu g L-1 Zn. (C) 2009 Elsevier B.V. All rights reserved.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The application of multi-wavelength holography for surface shape measurement is presented. In our holographic setup a Bi12TiO 20 (BTO) photorefractive crystal was the holographic recording medium and a multimode diode laser emitting in the red region was the light source in a two-wave mixing scheme. The holographic imaging with multimode lasers results in multiple holograms in the BTO. By employing such lasers the resulting holographic image appears covered of interference fringes corresponding to the object relief and the interferogram spatial frequency is proportional to the diode laser free spectral range (FSR). We used a Fabry-Perot étalon at the laser output for laser mode selection. Thus, larger effective values of the laser FSR were achieved, leading to higher-spatial frequency interferograms and therefore to more sensitive and accurate measurements. The quantitative evaluation of the interferograms was performed through the phase stepping technique (PST) and the phase map unwrapping was carried out through the Cellular-Automata method. For a given surface, shape measurements with different interferogram spatial frequencies were performed and compared, concerning measurement noise and visual inspection.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A new multi-energy CT for small animals is being developed at the Physics Department of the University of Bologna, Italy. The system makes use of a set of quasi-monochromatic X-ray beams, with energy tunable in a range from 26 KeV to 72 KeV. These beams are produced by Bragg diffraction on a Highly Oriented Pyrolytic Graphite crystal. With quasi-monochromatic sources it is possible to perform multi-energy investigation in a more effective way, as compared with conventional X-ray tubes. Multi-energy techniques allow extracting physical information from the materials, such as effective atomic number, mass-thickness, density, that can be used to distinguish and quantitatively characterize the irradiated tissues. The aim of the system is the investigation and the development of new pre-clinic methods for the early detection of the tumors in small animals. An innovative technique, the Triple-Energy Radiography with Contrast Medium (TER), has been successfully implemented on our system. TER consist in combining a set of three quasi-monochromatic images of an object, in order to obtain a corresponding set of three single-tissue images, which are the mass-thickness map of three reference materials. TER can be applied to the quantitative mass-thickness-map reconstruction of a contrast medium, because it is able to remove completely the signal due to other tissues (i.e. the structural background noise). The technique is very sensitive to the contrast medium and is insensitive to the superposition of different materials. The method is a good candidate to the early detection of the tumor angiogenesis in mice. In this work we describe the tomographic system, with a particular focus on the quasi-monochromatic source. Moreover the TER method is presented with some preliminary results about small animal imaging.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

In questo studio ci siamo proposti di investigare i sistemi di modulazione automatica della dose sui sistemi TC Multislice (Automatic Exposure Control – AEC) da tre diversi produttori, aventi differenti indicatori di qualità delle immagini. Il presente lavoro è stato svolto presso il Servizio di Fisica Sanitaria dell’Azienda Ospedaliera Universitaria - Policlinico Sant’Orsola-Malpighi di Bologna e consiste in un’analisi quantitativa della dose impiegata durante esami di Tomografia Computerizzata Multi-Slice (TCMS) e delle rispettive immagini radiologiche. Le immagini sono state acquisite con : GE LightSpeed VCT 64 e GE LightSpeed 16 (AEC AutomA 3D longitudinale e angolare), Siemens Sensation 16 (AEC CARE Dose 4D combinato), Philips Brilliance 16 e iCT 64 (separati in AEC ZDOM longitudinale e AEC DDOM angolare). Le acquisizioni TCMS sono state effettuate a differenti kV e mA di riferimento, al fine di investigarne gli effetti sulla modulazione, impiegando algoritmi di ricostruzione standard presenti su ogni macchina. Due fantocci antropomorfi simulanti la zona del torace e dell’addome sono stati utilizzati per simulare un paziente standard posizionato come in un esame clinico di routine ; a questo proposito, sono stati impiegati protocolli elicoidali standard con e senza modulazione. Sono inoltre stati testati differenti valori di indice di qualità delle immagini. Il profilo dei mA lungo la lunghezza è stato ottenuto utilizzando ImageJ, un programma open source comunemente utilizzato per l’elaborazione di immagini; i mAs sono stati normalizzati ad un fattore che tiene conto delle differenti geometrie e delle filtrazioni dei diversi scanner tomografici analizzati nell’esperienza. Il rumore è stato valutato tramite la scelta di determinate ROI (Region Of Interest) localizzate in aree il più possibili uniformi disponibili lungo i fantocci. Abbiamo registrato che una variazione del Noise Index o dei mAs di riferimento a seconda della tipologia di macchina analizzata risulta in uno shift dei profili di dose; lo stesso si è verificato quando sono stati cambiato kV o mA nella scout di acquisizione. Sistemi AEC longitudinali e combinati hanno mostrato profili di mAs normalizzati simili tra loro, con valori elevati evidenziati nella zona delle spalle e zona pelvi; sono state osservate differenze del 30-40% tra i differenti scanner tomografici. Solo in un caso di macchina analizzata si è verificato un comportamento opposto rispetto alle altre due tipologie di macchina in esame. A dispetto della differente natura dei sistemi AEC, i risultati ottenuti dai protocolli combinati e longitudinali sono simili tra loro. Il rumore presente nelle immagini è aumentato ad un livello accettabile e la sua uniformità lungo la direzione di scan è migliorata.